Search NASA⌕ Search

SEARCH · Search NASA

Results for “PHASE IMAGING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Microstructural transformations and kinetics of high-temperature heterogeneous gasless reactions by high-speed x-ray phase-contrast imaging

Heterogeneous gasless reactive systems, including high-energy density metal-nonmetal compositions, have seen increasing study due to their various applications. However, owing to their high reaction temperature, short reaction time, and small scale of heterogeneity, investigation of their reaction mechanisms and kinetics is very difficult. In this study, microstructural changes and the kinetics of product layer growth in the W-Si system was investigated using a high-speed x-ray phase-contrast imaging technique. Using the Advanced Photon Source of Argonne National Laboratory, this method allowed direct imaging of irreversible reactions in the W-Si reactive system at frame rates up to 36 000 frames per second with 4 {mu}s exposure and spatial resolution of 10 {mu}m. Details of the Si melt and reactions between W and Si, that are unable to be viewed with visible-light imaging, were revealed. These include processes such as the initiation of nucleated melting and other physical phenomena that provide insight into the mixing of reactants and subsequent reaction. Through the use of this imaging technique and future optimization in the imaging process, a model for accurately identifying kinetics of chemical reactions, both spatially and temporally, is also proposed.

36 MATERIALS SCIENCE↗

X-Ray Radiography and Phase-Contrast Imaging of the Engine Combustion Network Spray B Sprays and Injection

X-ray measurements of diesel sprays from two of the Engine Combustion Network (ECN) Spray B injectors are described. Measurements in these three-hole nozzles complement both visible light measurements of these sprays and previous x-ray measurements of the axial single-hole ECN Spray A injectors. Both axial and lateral motions of the injector needle valve were measured with x-ray phase contrast imaging. Additionally, the liquid mass distribution in room temperature sprays at elevated ambient pressure was determined with x-ray radiography. Measurements of both needle valve motion and spray distribution were performed at both the standard Spray A/B conditions and with selected variations of injection pressure, ambient density, and injection timing. The needle valve motion for the Spray B injectors is quite similar to that of the Spray A injectors, though little lateral motion is seen in either Spray B injector. Compared to the sprays from the Spray A injectors, the sprays from Spray B penetrate more slowly in the near-nozzle region, demonstrate a broader, more uniform distribution in the transverse direction, and are significantly more variable with respect to time. These differences demonstrate the importance of studies with multi-hole nozzles to provide insight into applied diesel combustion.

42 ENGINEERING↗

Strain-driven oxygen vacancy ordering in LaNiO 3 thin films revealed by integrated differential phase contrast imaging in scanning transmission electron microscopy

Rare-earth nickelates, such as LaNiO 3 (LNO), exhibit complex electronic properties, with ordered oxygen vacancies (OOV) influencing conductivity and magnetic behavior. We investigate the structural stability of strain-induced OOV phases in LNO thin films grown on SrTiO 3 substrates and the impact of Ruddlesden–Popper (RP) faults. Using high-angle annular dark-field scanning transmission electron microscopy (HAADF-STEM) and integrated differential phase contrast (iDPC) STEM imaging, we conducted atomic-scale structural and compositional analyses of OOV. Geometric phase analysis (GPA) was employed to measure the strain in fault-free and RP fault regions, while density functional theory (DFT) calculations explored different OOV arrangements in the LNO phase. Simulated iDPC-STEM imaging of energy-stabilized structures was performed to correlate with experimental results. Here, our findings reveal superstructure modulation in the chemical composition and atomic-scale lattice structure in LNO, primarily due to the formation of the OOV in Ni–O layers of the LaNiO 2.5 phase. The out-of-plane compressive strain of about 2% stabilizes this phase, reducing the strain, diminishing OOV, and transforming them into LNO.

36 MATERIALS SCIENCE↗

Qualification of a Null Lens Using Image-Based Phase Retrieval

In measuring the figure error of an aspheric optic using a null lens, the wavefront contribution from the null lens must be independently and accurately characterized in order to isolate the optical performance of the aspheric optic alone. Various techniques can be used to characterize such a null lens, including interferometry, profilometry and image-based methods. Only image-based methods, such as phase retrieval, can measure the null-lens wavefront in situ - in single-pass, and at the same conjugates and in the same alignment state in which the null lens will ultimately be used - with no additional optical components. Due to the intended purpose of a Dull lens (e.g., to null a large aspheric wavefront with a near-equal-but-opposite spherical wavefront), characterizing a null-lens wavefront presents several challenges to image-based phase retrieval: Large wavefront slopes and high-dynamic-range data decrease the capture range of phase-retrieval algorithms, increase the requirements on the fidelity of the forward model of the optical system, and make it difficult to extract diagnostic information (e.g., the system F/#) from the image data. In this paper, we present a study of these effects on phase-retrieval algorithms in the context of a null lens used in component development for the Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission. Approaches for mitigation are also discussed.

Bolcar, Matthew R.↗

Development of an Ultrahigh-bandwidth Phase Contrast Imaging System for detection of electron scale turbulence and Gigahertz Radio-Frequency Waves

The study of waves and turbulence is vital to the development of future reactor-grade plasma devices developed in the quest for fusion energy. These fluctuations are responsible for moving heat and particles across the magnetic field, and a predictive understanding of them is needed to achieve the density and temperature required to sustain a plasma fusion reaction. While many techniques have been developed for measuring waves and fluctuations, every measurement method has limitations. There are relatively few techniques for measuring very high frequency fluctuations, such as radio frequency waves injected to heat the plasma, unstable waves driven by suprathermal particles, or short wavelength electrostatic waves driven by electron temperature or density gradients. The present project builds upon the proven phase contrast imaging (PCI) technique to extend the response of the diagnostic by orders of magnitude in frequency and almost a factor of ten in spatial resolution. PCI provides a measurement of electron density based on small angle scattering of a CO-2 laser beam by using optical techniques to render a phase shift as an intensity change on a detector. Due to the telecommunications revolution, technological development by manufacturers has focused on components in the near -infrared, so that high- quality lasers and detectors at 1.55 µm are readily available. Shifting PCI design to a new, shorter wavelength has numerous advantages and challenges. Similar detector performance is available with room-temperature arrays with GHz bandwidth, while the detector arrays for 10.6 µm required liquid nitrogen cooling and were therefore limited to a bandwidth of about 1 MHz. Shifting to a shorter wavelength reduces the angle at which the laser beam scatters off of plasma waves, allowing more such scattered components to pass through the aperture of the vacuum vessel port and be collected by the PCI, which increases the spatial resolution. Concomitant with these benefits, various questions of performance arise. At shorter laser wave- length, the sensitivity to mirror and lens quality is increased, the contribution of the laser to the overall system noise is increased, and the sensitivity to vibrations is increased. The custom optical components at the heart of the PCI technique were required to be properly scaled for the shorter wavelength, so fabrication technologies needed to be explored. This project was designed to show that a low noise, high response PCI system at 1.55 µm could be constructed and operated, and then to quantify potential issues to allow extrapolation to a full-size production system providing physics measurements on a large plasma device. The first stage, producing the custom optical component called a Phase Plate, was successfully achieved using two methods. First, an easily reproduced masking and coating technique was able to produce good phase plates with the required parameters. Second, a nanofabrication technique was found to produce extremely high quality phase plates at a competitive price. The PCI constructed with the new phase plates and 1.55 µm laser was found to provide excellent wavelength measurements with the theoretically expected response. The sensitivity to optical surface quality was found to be in line with previous measurements at 10.6 µm. The observed signal-to-noise ratio was similar to the theoretically expected value. The effect of vibrations on PCI was studied with the first measurement of the effect of beam motion on PCI response and comparison to theory, allowing for a quantitative prediction of the effect of vibrations on a production PCI system and the requirements for improved beam stabilization. PCI is an extremely cost-effective method to provide a low noise, absolutely calibrated measurement of plasma fluctuations across a wide spatial scale. This project has shown that a 1.55 µm PCI using modern techniques and components is less expensive than the 10.6 µm PCI of a few years ago, with the largest savings in phase plate fabrication and the infrared detector array.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Integrative Quantitative-Phase and Airy Light-Sheet Imaging

Light-sheet microscopy enables considerable speed and phototoxicity gains, while quantitative-phase imaging confers label-free organelle recognition and metabolic information that are inaccessible by conventional methods. We report the fusion of these two modalities onto a standard inverted microscope that retains compatibility with microfluidics. We describe the utilization of an accelerating Airy-beam light-sheet yielding identical imaging areas with interferometry, and an application in unmasking the effects of cellular noise on metabolic compartmentalization.

Biological sciences, Biological techniques, Micros↗

Phase-contrast imaging method based on fast Kerr optical nonlinearity of air

The visualisation of a transparent phase object (gas jet) and the brightness inversion at the image of a nontransparent amplitude object (metal wire) is implemented using the nonlinear phase-contrast method based on the fast Kerr nonlinearity of the ambient air. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A new fast two-color interferometer at Alcator C-Mod for turbulence measurements and comparison with phase contrast imaging

Accurately predicting the turbulent transport properties of magnetically confined plasmas is a major challenge of fusion energy research. Validation of transport models is typically done by applying so-called “synthetic diagnostics” to the output of nonlinear gyrokinetic simulations, and the results are compared to experimental data. As part of the validation process, comparing two independent turbulence measurements to each other provides the opportunity to test the synthetic diagnostics themselves; a step which is rarely possible due to limited availability of redundant fluctuation measurements on magnetic confinement experiments. At Alcator C-Mod, phase-contrast imaging (PCI) is a commonly used turbulence diagnostic. PCI measures line-integrated electron density fluctuations with high sensitivity and wavenumber resolution (1.6 cm{sup −1}≲|k{sub R}|≲11 cm{sup −1}). A new fast two-color interferometry (FTCI) diagnostic on the Alcator C-Mod tokamak measures long-wavelength (|k{sub R}|≲3.0 cm{sup −1}) line-integrated electron density fluctuations. Measurements of coherent and broadband fluctuations made by PCI and FTCI are compared here for the first time. Good quantitative agreement is found between the two measurements. This provides experimental validation of the low-wavenumber region of the PCI calibration, and also helps validate the low-wavenumber portions of the synthetic PCI diagnostic that has been used in gyrokinetic model validation work in the past. We discuss possibilities to upgrade FTCI, so that a similar comparison could be done at higher wavenumbers in the future.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ICRF Mode Conversion Studies with Phase Contrast Imaging and Comparisons with Full-Wave Simulations

Waves in the ion cyclotron range of frequencies (ICRF) are widely used to heat toka-mak plasmas. In a multi-ion-species plasma, the FW converts to ion cyclotron waves (ICW) and ion Bernstein waves (IBW) around the ion-ion hybrid resonance (mode conversion). The mode converted wave is of interest as an actuator to optimise plasma performance through flow drive and current drive. Numerical simulations are essential to describe these processes accurately, and it is important that these simulation codes be validated. On Alcator C-Mod, direct measurements of the mode converted waves have been performed using Phase Contrast Imaging (PCI), which measures the line-integrated electron density fluctuations. The results were compared to full-wave simulations AORSA and TORIC. AORSA is coupled to a Fokker-Planck code CQL3D for self-consistent simulation of the wave electric field and the minority distribution function. The simulation results are compared to PCI measurements using synthetic diagnostic. The experiments were performed in D-H and D-{sup 3}He plasmas over a wide range of ion species concentrations. The simulations agreed well with the measurements in the strong absorption regime. However, the measured fluctuation intensity was smaller by 1-2 orders of magnitudes in the weakly abosorbing regime, and a realistic description of the plasma edge including dissipation and antenna geometry may be required in these cases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray Phase Contrast Imaging of the Impact of a Single HMX Particle in a Polymeric Matrix

A thorough understanding of the mechanisms by which high explosives (HEs) are shock initiated, especially at the particle scale, is still in demand. One approach to explain shock initiation phenomenon is hot spot theory, which suggests that distributed energy in energetic material is localized due to shock or impact to generate the high temperatures for ignition. Here, we focus on the impact response of a HE polycrystalline particle, specifically HMX, in a polymer matrix. This represents a simplified analog of a traditional polymer-bonded explosive (PBX) formulation. A light gas gun, together with high-speed x-ray phase contrast imaging (PCI), was used to study the impact response of a single particle of production-grade HMX in a Sylgard-184® matrix. The high-speed x-ray PCI allows for real-time visualization of HE particle behavior. The experiments revealed that, at impact velocities of ~ 200 m s -1 , the energetic particle was cracked and crushed. When the impact velocity was increased to 445 m s -1 , a significant volume expansion of the particle was observed. This volume expansion is considered to be the result of chemical reaction within the HE particle.

42 ENGINEERING↗

Measurements of ion cyclotron range of frequencies mode converted wave intensity with phase contrast imaging in Alcator C-Mod and comparison with full-wave simulations

Radio frequency waves in the ion cyclotron range of frequencies (ICRF) are widely used to heat tokamak plasmas. In ICRF heating schemes involving multiple ion species, the launched fast waves convert to ion cyclotron waves or ion Bernstein waves at the two-ion hybrid resonances. Mode converted waves are of interest as actuators to optimise plasma performance through current drive and flow drive. In order to describe these processes accurately in a realistic tokamak geometry, numerical simulations are essential, and it is important that these codes be validated against experiment. In this study, the mode converted waves were measured using a phase contrast imaging technique in D-H and D-{sup 3}He plasmas. The measured mode converted wave intensity in the D-{sup 3}He mode conversion regime was found to be a factor of {approx}50 weaker than the full-wave predictions. The discrepancy was reduced in the hydrogen minority heating regime, where mode conversion is weaker.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High speed X-ray phase contrast imaging of energetic composites under dynamic compression

Fracture of crystals and subsequent frictional heating are associated with formation of hot spots in energetic composites such as polymer bonded explosives (PBXs). Traditional high speed optical imaging methods cannot be used to study the dynamic sub-surface deformation and fracture behavior of such materials due to their opaque nature. In this study, high speed synchrotron X-ray experiments are conducted to visualize the in situ deformation and fracture mechanisms in PBXs manufactured using octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX) crystals and hydroxyl-terminated polybutadiene (HTPB) binder. A modified Kolsky bar apparatus was used to apply controlled dynamic compression on the PBX specimens, and a high speed synchrotron X-ray phase contrast imaging (PCI) setup was used to record the in situ deformation and failure in the specimens. The experiments show that synchrotron X-ray PCI provides a sufficient contrast between the HMX crystals and the doped binder, even at ultrafast recording rates. Under dynamic compression, most of the cracking in the crystals was observed to be due to the tensile stress generated by the diametral compression applied from the contacts between the crystals. Tensile stress driven cracking was also observed for some of the crystals due to the transverse deformation of the binder and superior bonding between the crystal and the binder. In conclusion, the obtained results are vital to develop improved understanding and to validate the macroscopic and mesoscopic numerical models for energetic composites so that eventually hot spot formation can be predicted.

36 MATERIALS SCIENCE↗

X-ray Phase Contrast Imaging of the Impact of Multiple HMX Particles in a Polymeric Matrix

The initiation of high explosives (HEs) under shock loading lacks a comprehensive understanding: particularly at the particle scale. One common explanation is the hot spot theory, which suggests that energy in the material resulting from the impact event is localized in a small area causing an increase in temperature that can lead to ignition. This study focuses on the response of HMX particles (a common HE) within a polymer matrix (Sylgard-184 (R)), a simplified example of a polymer-bound explosive (PBX). These PBXs consist of multiple HMX particles in a single polymer-bound sample. A light gas gun was used to load the samples at impact velocities above 400 m/s. The impact events were visualized using X-ray phase-contrast imaging (PCI) allowing real-time observation of the impact event. The experiment used two different types of samples (multi-particle and two crystals) and found evidence of cracking and debonding in both sample types. Additionally, it was found that the multiple particle samples showed similar evidence of damage at lower velocities than that of single particle samples. This is an expected result as the multiple particles add additional interfaces for stress concentration and frictional heating.

42 ENGINEERING↗

Single-shot X-ray phase-contrast imaging using two-dimensional gratings

We developed a two-dimensional gratings-based X-ray interferometer that requires only a single exposure for clinical radiography. The interferometer consisted of a checkerboard phase grating for {pi} phase modulation and a latticed amplitude grating. Using a synchrotron radiation source, the phase grating modulates the X-rays and generates a self-image, transformed to a moire fringe by the amplitude grating. To allow use of a conventional X-ray tube, the latticed source grating was installed downstream from the X-ray tube. Differential phase-contrast and scattering images in two orthogonal directions were obtained by Fourier analysis of the single moire fringe image and an absorption image. Results show that characteristic features of soft tissue in two orthogonal directions were clearly shown in the differential phase-contrast images.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Region-of-Interest Tomography for Grating-Based X-Ray Differential Phase-Contrast Imaging

We report numerical and experimental results demonstrating accurate region-of-interest computed tomography (CT) reconstruction based on differential phase-contrast projection (DPC) images. The approach removes the constraint of covering the entire sample within the field of view of the image detector. Particularly for biomedical applications, the presented DPC-CT region-of-interest approach will allow for the visualization of previously inaccessible details deep inside an entire animal or organ. We envisage that this development will also be of interest for potential future clinical applications, because grating-based DPC-CT can be implemented with standard x-ray tube sources.

60 APPLIED LIFE SCIENCES↗

Quantitative phase microscopy monitors subcellular dynamics in single cells exposed to nanosecond pulsed electric fields

A substantial body of literature exists to study the dynamics of single cells exposed to short duration (<1 μs), high peak power (~1 MV/m) transient electric fields. Much of this research is limited to traditional fluorescence-based microscopy techniques, which introduce exogenous agents to the culture and are only sensitive to a single molecular target. Quantitative phase imaging (QPI) is a coherent imaging modality which uses optical path length as a label-free contrast mechanism, and has proven highly effective for the study of single-cell dynamics. In this work, we introduce QPI as a useful imaging tool for the study of cells undergoing cytoskeletal remodeling after nanosecond pulsed electric field (nsPEF) exposure. In particular, we use cell swelling, dry mass and disorder strength measurements derived from QPI phase images to monitor the cellular response to nsPEFs. We hope this demonstration of QPI's utility will lead to a further adoption of the technique for the study

59 BASIC BIOLOGICAL SCIENCES↗

STEM Ptychographic Holography of Electric and Magnetic Potentials

The development of fast an efficient direct electron imaging detectors have enabled the advancement of phase-imaging techniques in STEM such as iterative ptychography. As beneficial as these techniques are to imaging phase objects, the information recorded in the raw data is due to phase gradients across the probe, so it can be challenging to reconstruct slowly varying phase at lower spatial frequencies such as those induced by electric or magnetic potentials within the specimen. STEM holography [1,2] is an interferometric 4D-STEM technique where electrons in the beam are coherently divided into a superposition of two or more spatially separated probes which are then scanned over the specimen. For example, in a two-beam superposition, the two probes form overlapping bright field discs at the detector which then interfere (left of Fig. 1). Furthermore, if one probe passes through vacuum while the other transmits through the specimen, the resulting relative phase shift can be measured by recording shifts in the interference pattern. STEM holography is thus directly sensitive to the phase of the probe relative to the reference beam, and this phase can be measured regardless of the convergence angle of the probe, unlike single beam ptychography.

Biological Sciences↗

'Edge illumination' in X-ray Phase Contrast Imaging

In the late '90s, the concept of 'edge illumination' was developed at ELETTRA in Italy as an alternative method to increase the phase sensitivity of an imaging system. The main idea was to be able to reproduce the fine angular selection of 'analyzer' crystals without actually using a crystal, as this would allow employing the method with divergent and polychromatic (i.e. conventional) x-ray sources. It was observed that this could be achieved by illuminating only the edges of the detector pixels, and that the method's sensitivity could be progressively increased by illuminating smaller pixel fractions closer to its physical edge. A few years later the idea was adapted for use with a conventional source by means of two sets of x-ray masks ('coded aperture' masks), which enabled obtaining the same effect for each row (or column) of pixels of an area detector illuminated by a cone beam. This article reviews the method and presents recent examples of application.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗