Search NASA⌕ Search

SEARCH · Search NASA

Results for “PHOTOMULTIPLIER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Large area double scattering telescope for balloon-borne studies of neutrons and gamma rays

A large area double scattering telescope for balloon-borne research is described. It measures the flux, energy and direction of 2-100 MeV neutrons and 0.5-30 MeV gamma rays. These measurements are made using time-of-flight and pulse height analysis techniques with two large tanks of mineral oil liquid scintillator. Results from Monte Carlo calculations of the efficiency, energy resolution and angular resolution are presented and the electronics implementation for the processing of 80 photomultiplier tubes signals will be discussed. The detector weighs 800 kg with a large part of this weight being the liquid scintillator (320 kg). It will be flown at 3 mbars for flight durations up to 40 hours. The first flight is planned for Spring, 1975.

Zych, A. D.↗

The Apollo gamma-ray spectrometer

A gamma-ray spectrometer has been flown on the Apollo 15 and 16 spacecraft to determine the lunar-surface composition and measure the cosmic gamma-ray flux. The instrument included a NaI(Tl) scintillation crystal coupled to a 7.6-cm photomultiplier tube, a plastic mantle for anti-coincidence rejection of charged particles, and 511 channels of analysis. Boom-mounted operation permitted a significant reduction in the background. The data were transmitted on an event-by-event basis. About 22% of the lunar surface was mapped and spectra of the cosmic gamma-ray flux over an energy range of 0.065-27.5 MeV have been obtained.

Harrington, T. M.↗

Calibration of large area scintillation counters on cosmic rays

Construction and calibration are reported for a 6-sq m scintillation counter consisting of two pieces of clear Lucite optically joined along a common edge, sixteen squares of plastic scintillator optically coupled on top of the Lucite, and eight photomultiplier tubes for light collection. Calibration of this counter using an anticoincidence counter to exclude multiple particle events is described. Theoretical calculations for purely electromagnetic extensive air showers indicate that this counter should detect an average of 2.5 particles per event, while the calibration data yield about 1.8 particles per event. It is shown that the anticoincidence-counter calibration method must be used for counters with areas of more than a few square meters if calibration on the response from a single particle of an extensive air shower is desired.

Saterlie, S. F.↗

An experimental study of ultraviolet radiation behind incident normal shock waves in CO2 at Venusian entry speeds

Radiation intensity profiles behind incident normal shock waves in pure CO2 have been measured spectroscopically in the Langley Arc-Driven Shock Tube. These profiles, which were obtained for shock velocities between 9 and 13 km/sec and ambient densities corresponding to Venus altitudes between 100 and 80 km, were measured in the vacuum ultraviolet regime. Wavelengths of 127.7, 158.0, 177.5, and 195.0 nm were monitored simultaneously using a four-channel vacuum spectrograph equipped with sodium-salicylate-coated photomultipliers, thereby including the CO(4+) band system which is the most prominent radiator. Measured nonequilibrium overshoots are modeled to provide a means of estimating the effect of nonequilibrium radiation heating to the stagnation region of proposed aero-shells for Venusian entry. These results indicate a significant increase in radiative heating due to nonequilibrium effects. The measurements are believed to represent the most accurate data available on the effect of nonequilibrium radiative heat transfer for Venus entry. This accuracy is primarily due to improved spectrographic instrumentation, which is discussed in some detail regarding its application in related studies.

Nealy, J. E.↗

The four- and five-band multispectral scanners for Landsat

The earth resources sensing Multispectral Scanner (MSS) for the Landsat satellite has two versions; one with four spectral bands from 0.5 to 1.1 microns, and one with five bands, the added band being 10.4 to 12.6 microns. This paper describes optical design and performance. The instrument uses a flat, object-space scanning mirror of near-linear motion, with a sensitive optical position monitor to detect mirror angular position. The 22.9-cm aperture telescope images the scene on an array of fiber optics, which dissect and transmit the scene energy to photomultiplier tubes detecting in Bands 1, 2, and 3, and silicon photodiodes detecting Band 4. Band 5 energy passes the fiber optic assembly and is reimaged on a radiatively cooled mercury cadmium telluride (HgCdTe) detector. The orbiting four-band scanner is furnishing data registered to better than 50-m band-to-band and resolving 80-m repetitive pattern over a 185-km swath width from 907-km altitude.

Lansing, J. C., Jr.↗

Simplified deflection-coil linearity testing

Mask placed over face of image-dissecting photomultiplier tube has precision array of pinholes that permit light to impinge on tube at known points. Signals are fed to deflection coil which sweeps beam across each point without complex operator procedures.

Kramer, G. P.↗

Vacuum-ultraviolet reflectometer

Baffle, three-blade chopper, and split spherical mirror transmit alternating dual beam into integrating sphere. Alternating reference and sample beams are detected by high gain photomultiplier and modified logarithmic ratiometer. Device is useful in fusion research, high power laser work, and spectrometer or monochromator construction.

Allen, T. H.↗

Quantitative determination of smoke and toxic product potential of materials with the AMINCO (registered) NBS smoke density chamber

Quantitative measurements of smoke obscuration produced by standard area samples under high energy pyrolysis both with and without an ignition source, using a collimated vertical light beam in conjunction with an ultra-linear photomultiplier microphotometer are obtainable with the smoke density chamber. Results are expressed in dimensionless specific optical density permitting usage calculations in accordance with a geometric relationship.

Greenberg, S.↗

Laser Doppler spectrometer method of particle sizing

A spectrometer for the detection of airborne particulate pollution in the submicron size range is described. In this device, airborne particles are accelerated through a supersonic nozzle, with different sizes achieving different velocities in the gas flow. Information about the velocities of the accelerated particles is obtained with a laser-heterodyne optical system through the Doppler shift of light scattered from the particles. Detection is accomplished by means of a photomultiplier. Nozzle design and signal processing techniques are also discussed.

Weber, F. N.↗

Applications of chemiluminescence to bacterial analysis

Luminol chemiluminescence method for detecting bacteria was based on microbial activation of the oxidation of the luminol monoanion by hydrogen peroxide. Elimination of the prior lysing step, previously used in the chemiluminescence technique, was shown to improve considerably the reproducibility and accuracy of the method in addition to simplifying it. An inexpensive, portable photomultiplier detector was used to measure the maximum light intensity produced when the sample is added to the reagent. Studies of cooling tower water show that the luminol chemiluminescence technique can be used to monitor changes in viable cell population both under normal conditions and during chlorine treatment. Good correlation between chemiluminescence and plate counts was also obtained in the analysis of process water used in paper mills. This method showed good potential for monitoring the viable bacteria populations in activated sludge used in waste treatment plants to digest organic matter.

Searle, N. D.↗

Research on techniques for laser ranging to optical corner reflectors on the moon. Research on laser techniques and single photo-electron detection and timing

Experimental studies using a pulsed LED, Cerenkov source, and a 100 ps laser were made of various photomultipliers and discriminator combinations. In addition, a new type of neodymium-YAG frequency doubled laser was used as the basis for the development of a stable, short pulse, high repetition rate laser system. This laser was then used in conjunction with atomic clocks to study the effect of gravitational potential on elapsed time. Avenues to promote the development of international cooperation in the area of lunar laser ranging were also explored.

Alley, C. O.↗

Short time transient periodicities from Cyg X-1

The temporal behavior of three new events of modulated optical emission from Cyg X1, detected in July 1975, is presented. Short time periodicities in the optical band are investigated. Single photon pulses from the photomultiplier are recorded on magnetic tape together with a very accurate 1 kHz reference frequency. During playback of the tape, the reference signal gives a 1 ms timing to a scaler interfaced with a small processor and the number of photon per millisecond is recorded on a digital tape.

Auriemma, G.↗

Chemiluminescence Study on Thermal Degradation of Aircraft Tire Elastomers

Since the autoxidative process accounts in part for the degradation of rubber, including aircraft tires, it was felt that a study of the chemiluminescence from unsaturated elastomers could contribute significantly to an understanding of the degradation mechanism. The study revealed similarities in chemiluminescence behavior between four elastomers which were investigated, and it shows that similar oxidation mechanisms occur. Oxidative chemiluminescence was observed from purified samples of cis-1,4-polybutadiene, cis-1,4-polyisoprene, trans-polypentenamer, and 1,2-polybutadiene in an oxygen atmosphere at 25-150 C. The elastomer samples were placed in a 600 watt oven which is equipped with gas inlets for introducing any desired atmosphere. Chemiluminescence emission from the samples was focused with a two inch quartz lens onto the detector of a 12" photomultiplier which is connected to a photon counter. A strip-chart recorder, connected to the counter, permitted automatic data collection. Diagrams of the apparatus are included. The chemical reactions which occurred from the thermal decomposition of the polymer samples are described, and results (and tabulated data) are discussed.

Mendenhall, G. D.↗

Computer simulation of a fringe type laser velocimeter

A computer simulation of a fringe type laser velocimeter has been written to determine the theoretical characteristics of the laser velocimeter when applied to a given flow field. The program includes the effect of particle size and composition on particle lag, light scattering characteristics and signal contrast. The model of the laser velocimeter includes the laser, optical system, photomultiplier, and counter type data processing electronics. The LV particle size analyzer is also modeled and incorporated in the program. An example application of the program to a Mach 5 wind tunnel using a backscatter laser velocimeter is presented.

Meyers, J. F.↗

Low-noise extended-frequency response with cooled silicon photodiodes

It is shown that a substantial reduction in internal noise generated by the photodiode and the preamplifier can be produced by a modest cooling of the components and by optimization of preamplifier design. With this reduction the silicon detectors can, in the SNR range of 5 or greater, produce better performance than photon-noise-limited photomultipliers. The circuit noise and frequency response model suggested by Goranson and Skipper (1974) is expanded to include the effects of frequency dependent FET voltage noise and FET load resistance noise. The modeling of the photodiode and preamplifier is described and the noise characteristics of a 0.01 Hz to 100 kHz bandwidth detector/amplifier channel are evaluated.

Neiswander, R. S.↗

Photon-counting detector arrays based on microchannel array plates

The recent development of the channel electron multiplier (CEM) and its miniaturization into the microchannel array plate (MCP) offers the possibility of fully combining the advantages of the photographic and photoelectric detection systems. The MCP has an image-intensifying capability and the potential of being developed to yield signal outputs superior to those of conventional photomultipliers. In particular, the MCP has a photon-counting capability with a negligible dark-count rate. Furthermore, the MCP can operate stably and efficiently at extreme-ultraviolet and soft X-ray wavelengths in a windowless configuration or can be integrated with a photo-cathode in a sealed tube for use at ultraviolet and visible wavelengths. The operation of one- and two-dimensional photon-counting detector arrays based on the MCP at extreme-ultraviolet wavelengths is described, and the design of sealed arrays for use at ultraviolet and visible wavelengths is briefly discussed.

Timothy, J. G.↗

Spectroscopic photoelectric imaging Fabry-Perot interferometer - Its development and preliminary observational results

In order to observe extended astronomical objects at high spatial and spectral resolution, we have constructed a spectroscopic photoelectric imaging Fabry-Perot interferometer (SPIFI). Among the properties chosen for the instrument are an air-spaced, piezoelectrically scanned design allowing an accurately settable free spectral range and employing a single etalon of high finesse. Careful design of the etalon mountings and optical train preserves high light throughput. We either obtain spectra of single spatial elements with a photomultiplier or use an SEC vidicon detector to record a series of images through the interferometer while scanning the wavelength in discrete steps. The latter procedure yields sufficient information to reconstruct spectral features over the entire object. For the conditions assumed, either series of observations requires only a small fraction of a rotational period for Jupiter or Saturn, for example.

Smith, W. H.↗

The energy spectrum of 10-50 BeV/nuc cosmic rays

We have obtained measurements of the energy spectra of cosmic ray nuclei with charge Z equals 5-14 in the 10-50 BeV/nuc energy interval from a gas Cerenkov detector flown aboard a high altitude balloon at Sioux Falls, South Dakota in September, 1974. The gas Cerenkov detector consists of a pressurized light diffusion chamber viewed by two separate banks of photomultiplier tubes. An analysis of the two signals permits a very effective rejection of background events as well as an understanding of the sources of broadening to be removed in the extraction of kinetic energy spectra from the gas Cerenkov detector pulse height distributions. The ratio of secondary to primary nuclei display a decrease with increasing energy as reported by other investigators.

Lezniak, J. A.↗