Search NASA⌕ Search

SEARCH · Search NASA

Results for “PLASMA FOCUS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Production of fissioning uranium plasma to approximate gas-core reactor conditions

The intense burst of neutrons from the d-d reaction in a plasma-focus apparatus is exploited to produce a fissioning uranium plasma. The plasma-focus apparatus consists of a pair of coaxial electrodes and is energized by a 25 kJ capacitor bank. A 15-g rod of 93% enriched U-235 is placed in the end of the center electrode where an intense electron beam impinges during the plasma-focus formation. The resulting uranium plasma is heated to about 5 eV. Fission reactions are induced in the uranium plasma by neutrons from the d-d reaction which were moderated by the polyethylene walls. The fission yield is determined by evaluating the gamma peaks of I-134, Cs-138, and other fission products, and it is found that more than 1,000,000 fissions are induced in the uranium for each focus formation, with at least 1% of these occurring in the uranium plasma.

Lee, J. H.↗

Measuring alpha eigenvalue of a subcritical system by a intense pulsed neutron source

Intense-Pulsed-Neutron-Source (IPNS) technique is a new approach to measure the subcriticality of a reactor system, which has been theoretically analyzed by us while not been verified in experiment in other reference. In INPS technique the reactivity is derived via the system response to a prompt pulsed neutron source. The method utilizes very intense neutron pulses (about 1010 neutrons/pulse) with the duration ranging from 10 ns to 100 ns, which are generated by the dense plasma focus (DPF) device filled with pure DT mixture as the working gas. The neutron pulse in high intensity provides the opportunity to measure the signal using a scintillator and a photo-multiplier tube (PMT) (the intense pulse radiation measure method) with the flight distance of only twenty centimeters. The attenuation of the dense plasma focus device must be faster than the subcritical system so that the attenuation of the system can be researched. In this paper, after a neutron pulse is injected into the subcritical reactor, the subcriticality is determined by measuring the instantaneous characteristics of the leaking reactor neutron. The Monte Carlo analysis shows that, with the linear arrangement of the dense plasma focus, the subcritical system and the detector, the signal-to-noise ratio at the measure point meets the investigate requirement, in which the 14 MeV neutrons are attenuated by the subcritical system. The detector is close with the subcritical system to reduce the influence of the outer background and the spread of time-of-flight of the neutrons. The measure system utilizing gated detection technology is characterized with fast attenuation time and large linear current, the a value obtained with this method is 2.05 μs{sup -1} while the measurements using the {sup 252}Cf stochastic pulsed source method and the Rossi-a method were 2.18μs{sup -1} and 2.16μs{sup -1}.It showed that the measured result obtained with dense plasma focus instantaneous pulsed source is consistent with those obtained with the other two traditional methods. This new method utilized only a single-shot pulse to determine the a value of the reactor system. Therefore, this quick measure method is recommendable. The influence caused by energy response of the detector should been taken into account since the measured result reflects the time behavior of group particle. The influence is discussed preliminarily in this paper. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Behavior of Langmuir Probes in Non-Equilibrium Plasmas

Langmuir probes are diagnostic tools used to determine electron temperature, number density, and plasma potential. Irving Langmuir first used an electrostatic probe in the 1920s to find these characteristics in ionized gases. Single, double, and triple Langmuir probes are commonly used in plasma diagnostics because of their relative simplicity. In the single probe, a swept voltage is applied between the probe tip and circuit common to acquire a waveform showing the collected current as a function of applied voltage. A double Langmuir probe consists of two tips, both inserted into the plasma, with a voltage applied between them. As this voltage is swept, a current-voltage characteristic is measured. In a triple probe three probe tips are electrically coupled to each other with constant non-swept voltages applied between each of the tips. The voltages are selected to represent three points on the single Langmuir probe I-V curve. Elimination of the voltage sweep makes it possible to measure time-varying plasma properties in transient plasmas. Triple Langmuir probe measurements have been widely employed for various types of plasmas, including pulsed and time-varying plasmas such as those seen in pulsed plasma thrusters (PPTs), dense plasma focus devices, plasma flows, and fusion experiments. The typical Langmuir probe analysis for determining electron temperature and number density of the plasma (for a single, double, or triple Langmuir probe) includes an assumption that the plasma is in thermal equilibrium. While the this assumption may be justified for some applications, it is unlikely that it is fully justifiable for pulsed and time-varying plasmas or for the entire time a plasma device is in use. In the present work, we model the responses of Langmuir probes as they are inserted into a range of simple equilibrium and non-equilibrium plasmas. We return to basic governing equations of probe current collection and compute the current to the probes for a distribution function consisting of two Maxwellian distributions with different temperatures (the two-temperature Maxwellian). A variation of this method is also employed, where one of the Maxwellians is offset from zero (in velocity space) to add a suprathermal beam of electrons to the tail of the main Maxwellian distribution (the bump-on-the-tail distribution function). For a range of parameters in these non-Maxwellian distributions, we compute the current collection to the probes. Comparing the distribution function that was assumed a priori with the plasma density and temperature one would infer when applying standard probe theory to analyze the collected currents serves to illustrate the effect a non- Maxwellian plasma would have on results interpreted using the equilibrium probe current collection theory, allowing us to state the magnitudes of these deviations as a function of the assumed distribution function properties.

Polzin, Kurt A.↗

Development and characterization of a high yield transportable pulsed neutron source with efficient and compact pulsed power system

The results of characterization experiments carried out on a newly developed dense plasma focus device based intense pulsed neutron source with efficient and compact pulsed power system are reported. Its high current sealed pseudospark switch based low inductance capacitor bank with maximum stored energy of ∼10 kJ is segregated into four modules of ∼2.5 kJ each and it cumulatively delivers peak current in the range of 400 kA–600 kA (corresponding to charging voltage range of 14 kV–18 kV) in a quarter time period of ∼2 μs. The neutron yield performance of this device has been optimized by discretely varying deuterium filling gas pressure in the range of 6 mbar–11 mbar at ∼17 kV/550 kA discharge. At ∼7 kJ/8.5 mbar operation, the average neutron yield has been measured to be in the order of ∼4 × 10{sup 9} neutrons/pulse which is the highest ever reported neutron yield from a plasma focus device with the same stored energy. The average forward to radial anisotropy in neutron yield is found to be ∼2. The entire system is contained on a moveable trolley having dimensions 1.5 m × 1 m × 0.7 m and its operation and control (up to the distance of 25 m) are facilitated through optically isolated handheld remote console. The overall compactness of this system provides minimum proximity to small as well as large samples for irradiation. The major intended application objective of this high neutron yield dense plasma focus device development is to explore the feasibility of active neutron interrogation experiments by utilization of intense pulsed neutron sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characteristics of magnetic island formation due to resistive interchange instability in helical plasma

Focusing attention on the magnetic island formation, we investigate the characteristics of the resistive interchange magnetohydrodynamics instabilities, which would limit a high beta operational regime in helical type fusion reactors. An introduction of a new index, i.e., the ratio of the magnetic fluctuation level to the radial displacement, enables us to make a systematic analysis on the magnetic island formation in the large helical device-like plasmas during the linear growth phase; (i) the interchange instability with the second largest growth rate makes the magnetic island larger than that with the largest growth rate when the amplitude of the radial displacement in both cases is almost the same as each other; (ii) applied to a typical tearing instability, the index is smaller than that for the interchange instability with the second largest growth rate.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The role of ambient gas confinement, plasma chemistry, and focusing conditions on emission features of femtosecond laser-produced plasmas

Ultrafast laser ablation coupled with optical emission spectroscopy is currently under development for standoff detection of elements and their isotopes for a wide range of application areas. In this work, we explore the role of ambient air pressure during the interaction of an ultrafast laser beam with two metallic targets (brass and uranium) with significantly different oxygen gas-phase reactivity. Plasma plumes were generated by focusing ~800 nm, ~35 fs pulses from an ultrafast laser system using a long focal length lens with f = 1 m. Two-dimensional spectral imaging was performed over the pressure range of 30 mTorr-700 Torr air to evaluate emission dynamics, plasma chemistry, signal-to-background ratio, and characteristic parameters (i.e. excitation temperature, electron density). An increase in ambient air pressure during ultrafast laser ablation leads to plume confinement and subsequent changes in the emission dynamics due to plasma chemistry as well as changes in plasma generation conditions (i.e. focused fs laser ablation versus filament ablation). Ablation crater morphologies were also investigated via scanning electron microscopy. Results indicate atomic emission intensity and signal-to-background ratios peak at moderate pressure levels (~50-100 Torr air) for both targets studied, although plasma chemistry influences uranium emission signatures. The emission features of the uranium plasma at pressures = 10 Torr showed the presence of atoms and oxide molecules which are co-located within the plume. We also find filament ablation leads to wider, more shallow craters compared to focused laser ablation. Our study provides unique insight into the interplay between plume dynamics, confinement, and oxygen chemistry of fs laser-produced plasmas and how these phenomena evolve with changing ambient air pressure.

Laser-produced plasma↗

Mass- and energy-analyses of ions from plasma by means of a miniature Thomson spectrometer

The paper presents an improved version of a miniature mass-spectrometer of the Thomson-type, which has been adopted for ion analysis near the dense plasma region inside a vacuum chamber. Problems connected with the separation of ions from plasma streams are considered. Input diaphragms and pumping systems, needed to ensure good vacuum inside the analyzing region, are described. The application of the miniature Thomson-type analyzer is illustrated by ion parabolas recorded in plasma-focus facility and rod plasma injector experiment. A quantitative analysis of the recorded ion parabolas is presented. Factors influencing accuracy of the ion analysis are discussed and methods of the spectrometer calibration are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Theory of electron current filamentation instability and ion density filamentation in the early development of a DPF discharge

Two-dimensional simulations of the initial stages of plasma formation in a dense plasma focus show the formation, in a few tens of nanoseconds, of a dense layer of plasma (n{sub e}{approx}10{sup 18} cm{sup -3},T{sub e}{approx}3 eV) in a thin layer surrounding the insulator-covered central anode of the focus device, and carrying axially-directed current at rather high current density.Earlier work on the filamentation of dense cathode plasma in high-power diodes seems to indicate that the anode plasma current layer in a dense plasma focus (DPF) device could be subject to the same instability, creating a growth of axially-directed filaments in the current density. The growth rate for resistive-thermal-driven filamentation, e.g. at 30 torr and {approx}3 eV electron temperature, exceeds the that due to non-thermal current (JxB) driving, and is determined by electron dynamics, so its evolution is quicker than the response-time of the ions.Nonetheless, with such a growing current-density perturbation as a seed and its increasing rippling of the azimuthal magnetic field as a driver, the ions will eventually take part in the azimuthal bunching, forming filaments in the ion density as well. The resistive-thermal-driven filamentation fields thus serve to 'hurry-up' the development of ion density filamentation, as shown approximately in the work presented here. This theory predicts, for light ions, a relatively early ({<=}250 ns) development of visible filaments along the anode, perhaps even before the main rundown phase of the focus plasma motion, and these filaments may persist during the 'liftoff' phase of the current layer to form the rundown phase of the plasma front. This work is supported by Larwenceville Plasma Physics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

X-ray emission from high temperature plasmas

The bremsstrahlung X-rays from a plasma focus device were investigated with emphasis on the emission versus position, time, energy, and angle of emission. It is shown that low energy X-rays come from the plasma focus region, but that the higher energy components come from the anode. The emission is anisotropic, the low energy polar diagram resembling a cardioid, while the high energy emission is a lobe into the anode. The plasma parameters were considered indicating that even in the dense focus, the plasma is collisionless near the axis. By considering the radiation patterns of relativistic electrons a qualitative picture is obtained, which explains the measured polar diagrams, assuming the electrons that produce the X-rays have velocity vectors lying roughly in a cone between the point of focus and the anode. The average electron energy is about 3keV at the focus and about 10 keV on the anode surface. Results are consistent with the converging beam model of neutron production.

Harries, W. L.↗

L-shell spectroscopic diagnostics of radiation from krypton HED plasma sources

X-ray spectroscopy is a useful tool for diagnosing plasma sources due to its non-invasive nature. One such source is the dense plasma focus (DPF). Recent interest has developed to demonstrate its potential application as a soft x-ray source. We present the first spectroscopic studies of krypton high energy density plasmas produced on a 3 kJ DPF device in Singapore. In order to diagnose spectral features, and to obtain a more comprehensive understanding of plasma parameters, a new non-local thermodynamic equilibrium L-shell kinetic model for krypton was developed. It has the capability of incorporating hot electrons, with different electron distribution functions, in order to examine the effects that they have on emission spectra. To further substantiate the validity of this model, it is also benchmarked with data gathered from experiments on the electron beam ion trap (EBIT) at Lawrence Livermore National Laboratory, where data were collected using the high resolution EBIT calorimeter spectrometer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of the plasma parameters in the PF-3 facility by the methods of X-ray spectroscopy

NeIX and NeX spectra emitted by the PF-3 high-current (2 MA) plasma focus facility are measured. A numerical model describing the spectral intensities of the emission of helium- and hydrogen-like neon ions from an optically thick plasma is proposed. The electron temperature T{sub e} and electron density n{sub e} in the plasma of the PF-3 facility are determined by comparing the calculated and measured emission spectra of neon.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Chasing ghosts: characterization of artifact generation in coded aperture decoding due to experimental implementation

Coded aperture imaging is a form of lensless aperture imaging that projects multiple overlapping images of the source onto the detector, enhancing signal strength, which is advantageous for low-flux sources or high-resolution imaging. This technique requires decoding of the detector signal to reconstruct the original source, which involves convolving the detector data with the aperture pattern. When the signal is from a centered point source, the reconstructed source image is known as the point spread function (PSF). A clean PSF without artifacts is a Dirac delta function [Appl. Opt. 20, 1858 (1981)]. This paper examines the robustness of the decoding process against variations in experimental tolerances by analyzing artifact growth in the reconstructed PSF. We illustrate the effects of incorrect magnification, rotation, and detector size and find that aperture–detector rotational misalignment about the imaging axis is the most sensitive parameter, with significant artifact generation occurring with angular offsets of less than one degree. We discuss compensation methods for imperfect aperture placement, finding that small detector sizes produce uncompensatable artifact generation, and compare theoretical predictions with experimental PSF measurements of a rank , 6.8 mm thick (less than one mean free path) coded aperture with a 3.5 mm cell size, conducted at the MegaJOuLe Neutron Imaging Radiography dense plasma focus [IEEE Trans. Plasma Sci. 49, 3299 (2021)] using a 2.45 MeV neutron source. Based on our findings, we recommend using magnified coded apertures in the under-sampled regime, which allows for the inclusion of fiducial markers to characterize aperture–detector rotational offsets and the addition of mechanical coupling, where possible, to constrain rotational and magnification offsets.

Selwood, M. P. [Lawrence Livermore National Labora↗

Characteristics of plasma-puff trigger for a inverse-pinch plasma switch

The plasma-puff triggering mechanism based on a hypocycloidal pinch geometry was investigated to determine the optimal operating conditions for the azimuthally uniform surface flashover which initiates plasma-puff under wide ranges of fill gas pressure of Ar, He and N2. The optimal fill-gas pressure range for the azimuthally uniform plasma-puff was about 120 mTorr less than or equal to P(sub op) less than or equal to 450 Torr for He and N2. For Argon 120 mTorr is less than or equal to P(sub op) is less than or equal to 5 Torr. The inverse-pinch switch was triggered with the plasma-puff and the switching capability under various electrical parameters and working gas pressures of Ar, He and N2 was determined. The azimuthally uniform switching discharges were dependent on the type of fill gas and its fill pressure. A new concept of plasma-focus driven plasma-puff will be discussed in comparison with the current hypocycloidal-pinch plasma-puff triggering.

Choi, Eun H.↗

Investigation Of Plasma Discharges Within Maja-PF Device Operated With Tungsten Inserts In The Central Electrode

The paper presents results of recent experimental studies with a MAJA-PF plasma-focus facility, as carried out for two different configurations of the end-plate of the central electrode. The main aim was to investigate an influence of the shape and material of the electrode end-plate on the formation and structure of the plasma column as well as to record and identify spectral lines of tungsten. The first version of the end-plate was made of Cu, while the second one had an insert made of a Cu-W alloy. Optical spectra were recorded by means of a Mechelle 900 spectrometer, operated with some delay in relation to a current peculiarity and with exposition times varied from 200 ns to 10 {mu}s. For shots with the Cu electrode spectral lines of deuterium (working gas) and carbon ions were recorded, but tungsten lines were not identified. It was estimated that the electron concentration changed from (8 divide 10)x10{sup 17} cm{sup -3} to about 2x10{sup 17} cm{sup -3} in 5 {mu}s after the current dip. In experiments with the second electrode version, among numerous spectral lines there were identified distinct WI and WII lines. Estimates of the tungsten ion concentration were impossible because of close positions of other lines. Diagrams of changes in the electron density are of importance for applications of DPM streams.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Accelerated ions from pulsed-power-driven fast plasma flow in perpendicular magnetic field

To understand the interaction between fast plasma flow and perpendicular magnetic field, we have investigated the behavior of a one-dimensional fast plasma flow in a perpendicular magnetic field by a laboratory-scale experiment using a pulsed-power discharge. The velocity of the plasma flow generated by a tapered cone plasma focus device is about 30 km/s, and the magnetic Reynolds number is estimated to be 8.8. After flow through the perpendicular magnetic field, the accelerated ions are measured by an ion collector. To clarify the behavior of the accelerated ions and the electromagnetic fields, numerical simulations based on an electromagnetic hybrid particle-in-cell method have been carried out. The results show that the behavior of the accelerated ions corresponds qualitatively to the experimental results. Faster ions in the plasma flow are accelerated by the induced electromagnetic fields modulated with the plasma flow.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gallium arsenide/gold nanostructures deposited using plasma method

The fabrication of gallium arsenide (GaAs) nanostructures on gold coated glass, quartz and silicon substrates using the high fluence and highly energetic ions has been reported. The high fluence and highly energetic ions are produced by the hot, dense and extremely non-equilibrium plasma in a modified dense plasma focus device. The nanostructures having mean size about 14 nm, 13 nm and 18 nm are deposited on gold coated glass, quartz and silicon substrates, respectively. The optical properties of nanostructures studied using absorption spectra show surface plasmon resonance peak of gold nanoparticles. In addition, the band-gap of GaAs nanoparticles is more than that of bulk GaAs suggesting potential applications in the field of optoelectronic and sensor systems.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Wide band gap gallium arsenide nanoparticles fabricated using plasma method

In this paper, we have reported the fabrication of gallium arsenide (GaAs) nanoparticles on quartz placed at distance of 4.0 cm, 5.0 cm and 6.0 cm, respectively from top of anode. The fabrication has been carried out by highly energetic and high fluence ions of GaAs produced by hot, dense and extremely non-equilibrium plasma in a modified dense plasma focus device. GaAs nanoparticles have mean size of about 23 nm, 16 nm and 14 nm for deposition at a distance of 4.0 cm, 5.0 cm and 6.0 cm, respectively. The nanoparticles are crystalline in nature as evident from X-ray diffraction patterns. The band gap of nanoparticles is found to increase from 1.425 eV to 5.37 eV at 4.0 cm distance, which further increases as distance increases. The wide band gap observed for fabricated GaAs nanoparticles suggest the possible applications of nanoparticles in laser systems.

77 NANOSCIENCE AND NANOTECHNOLOGY↗