Behavior of Triple Langmuir Probes in Non-Equilibrium Plasmas

A model of current collection in Langmuir probes is used to investigate the effect representative non- equilibrium plasmas under various conditions have on the electron temperature and number density that would be calculated through analysis of the probe collection characteristics. The model uses the distribution function to calculate the charged particle flux to a probe and then, for fixed applied voltages, the current values that satisfy continuity in the probes are determined. The triple probe is not scanned in voltage, so there is no practical way using experimental triple probe data to determine if the plasma is in equilibrium. As a consequence, a triple probe analysis typically relies on the assumption that the plasma is in equilibrium. Proceeding from this point, the numerically-generated non-equilibrium triple probe data are analyzed assuming that the plasma is in equilibrium, with the data compared to the initial distribution function inputs of plasma temperature and number density to determine the effect the non-equilibrium distribution has on plasma measurements. The temperature and number density are both significantly affected when a fraction of the particles in the distribution are shifted from the equilibrium configuration into the non-equilibrium part of the distribution function. For all instances studied, the computed electron temperature and number density are extremely sensitive to small deviations from equilibrium ( ≤ 5% of the plasma shifted into the non-equilibrium function). Shifting more of the plasma into the non-equilibrium distribution beyond this initial level does not produce a significant additional shift in the computed plasma properties.

Polzin, Kurt A.↗

Two-dimensional micron-step probe drive for laboratory plasma measurement

Laboratory measurement of small-scale ({approx}1 mm) magnetic phenomena over an extended area is a challenge requiring precise diagnostics. We present a novel two dimensional magnetic probe platform capable of directly measuring the magnetic field over a 36 cm{sup 2} region at spatial resolutions better than 1 mm. The platform is discussed in the context of an experiment at the Large Plasma Device facility at UCLA, designed to measure the magnetic interaction between two counterpropagating laser-produced plasmas. The use of a precise, repeatable positioning platform enables the recovery of information about the interaction using cross-correlation techniques.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Operation of a Langmuir Probe in a Photoelectron Plasma

Dust transport on the lunar surface is likely facilitated by the variable electric fields that are generated by changing plasma conditions. We have developed an experimental apparatus to study lunar photoelectric phenomena and gain a better understanding of the conditions controlling dust transport. As an initial step, Langmuir probe measurements are used to characterize the photoelectron plasma produced above a Zr surface, and these techniques will be extended to CeO{sub 2} and lunar simulant surfaces.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Emissive probe diagnostics in low temperature plasma--effect of the space charge and variations of the electron saturation current

We report on the effect of over{approx}underestimation of the plasma potential by the strongly emitting probe technique in the low temperature plasma due to the effect of the space charge of the emitted electrons; experimental data are compared with theoretical model. Further we studied the electron saturation current variations at varying probe heating and we found them to be closely related to the probe wire contamination. The study was performed in two types of low temeperature argon plasma--weakly magnetized plasma of the cylindrical magnetron and the hollow cathode plasma jet showing different trends.

36 MATERIALS SCIENCE↗

Ion current on a small spherical attractive probe in a weakly ionized plasma with ion-neutral collisions (kinetic approach)

The ion flux on a small attractive sphere (the sphere radius is much less than the Debye length) and the electric potential distribution around the sphere charged in a stationary weakly ionized plasma are calculated by the direct solution of the kinetic equation with the Bhatnagar-Gross-Krook collision term. Only a weak dependence of the ion flux on the electron temperature is found. An analytical approximation of the calculated ion current-voltage characteristics is proposed for intermediate collisionalities, where neither a collisionless theory nor a continuum fluid approach is valid. This approximation was used for calculation of the floating sphere potential. A reasonable agreement of the calculated floating sphere potential with prior numerical calculations is found.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Polarimeter for the General Fusion SPECTOR machine

A polarimeter has been designed to measure Faraday rotation and help to understand the profile of its safety factor, q, on the recently built SPECTOR magnetized target fusion machine at General Fusion. The polarimeter uses two counter-rotating, circularly polarized, 118.8 μm beams to probe the plasma. Grad-Shafranov simulations have been used to investigate the effect of measurement error and chord geometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The co-located arrangement of ECEI and MIR microwave imaging diagnostics on EAST tokamak

The co-located configuration of Passive Electron Cyclotron Emission Imaging (ECEI) and active Microwave Imaging Reflectometry (MIR) diagnostics systems has been successfully implemented on the EAST fusion reactor. These advanced 2D microwave diagnostic tools offer 10–20 mm poloidal spatial resolution through large aperture quasi optics. This arrangement not only optimizes the utilization of limited observation windows but also facilitates concurrent measurements of plasma density and electron temperature at specific toroidal positions. Furthermore, this co-located setup holds great promise for enhancing research into electron heat transport and other pivotal plasma phenomena.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and validation of the ball-pen probe for measurements in a low-temperature magnetized plasma

Ball-pen probes have been used in fusion devices for direct measurements of the plasma potential. Their application in low-temperature magnetized plasma devices is still subject to studies. In this context, a ball-pen probe has been recently implemented on the linear plasma device Mirabelle. Produced by a thermionic discharge, the plasma is characterized by a low electron temperature and a low density. Plasma confinement is provided by an axial magnetic field that goes up to 100 mT. The principle of the ball-pen probe is to adjust the saturation current ratio to 1 by reducing the electron current contribution. In that case, the floating potential of the probe is close to the plasma potential. A thorough study of the ball-pen probe operation is performed for different designs of the probe over a large set of plasma conditions. Comparisons between ball-pen, Langmuir, and emissive probes are conducted in the same plasma conditions. The ball-pen probe is successfully measuring the plasma potential in these specific plasma conditions only if an adapted electronics and an adapted probe size to the plasma characteristic lengths ({lambda}{sub D}, {rho}{sub ce}) are used.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Microwave resonances of a hairpin probe in a magnetized plasma

The effect due to the electron cyclotron frequency on the microwave resonances of a hairpin probe is investigated in a moderate to strongly magnetized plasma. The magnetic field is independently varied over a wide range from 0.01-0.13 T while maintaining the local plasma density constant. At strong magnetic fields the resonance frequency is found to be lower than that measured in vacuum implying that the relative plasma dielectric permittivity, epsilon{sub p}>1. It is proposed that the experiments reported here are consistent with a permittivity model that includes magnetic field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First application of a digital mirror Langmuir probe for real-time plasma diagnosis

For the first time, a digital Mirror Langmuir probe (MLP) has successfully sampled plasma temperature, ion saturation current, and floating potential together on a single probe tip in real time in a radio-frequency driven helicon linear plasma device. This is accomplished by feedback control of the bias sweep to ensure a good fit to I-V characteristics with a high frequency, high power digital amplifier and field-programmable gate array (FPGA) controller. Measurements taken by the MLP were validated by a low speed I-V characteristic manually collected during static plasma conditions. Plasma fluctuations, induced by varying the axial magnetic field (f̃ = 10 Hz), were also successfully monitored with the MLP. Further refinement of the digital MLP pushes it towards a turn-key system that minimizes the time to deployment and lessens the learning curve, positioning the digital MLP as a capable diagnostic for the study of low radio-frequency plasma physics. These demonstrations bolster confidence in fielding such digital MLP diagnostics in magnetic confinement experiments with high spatial and adequate temporal resolution such as edge plasma, scrape-off layer, and divertor probes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Langmuir probe characterization of laser ablation plasmas

For laser ablation plumes that are significantly ionized, Langmuir probes have proved to be a useful tool for measuring the plume shape, ion energy distribution, and electron temperature. Typically in laser ablation plasmas the flow velocity is supersonic, which complicates the interpretation of the current-voltage probe characteristic. In this paper we describe some recent developments on the application of Langmuir probes for laser ablation plume diagnosis. We have investigated the behavior of the probe when it is orientated perpendicular, and parallel, to the plasma flow, and show how an analytical model developed for plasma immersion ion implantation, can quantitatively describe the variation of the ion current with probe bias for the case when the plasma flow is along the probe surface. The ion signal recorded by a probe in the parallel position is proportional to the ion density and the square root of the bias voltage. It is shown that the current varies as m{sub i}{sup -1/2} so that by comparing the ion signals from the parallel and perpendicular positions it is possible to estimate the mass of the ions detected. We have also determined the temporal variation of electron temperature. A planar probe oriented parallel to the plasma flow, where the ion current due to the plasma flow is eliminated, gives a more reliable measurement of T{sub e} (<0.6 eV). The measured T{sub e} is consistent with the measured ion current, which is dependent on T{sub e} when the time taken for an element of plasma to traverse the probe is longer than the time taken for the matrix ion sheath extraction phase.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Single-shot spatiotemporal plasma density measurements with a chirped probe pulse

In this work, we present the development and demonstration of a diagnostic for the measurement of the spatial and temporal evolution of plasma density in a single shot. Single-shot Advanced Plasma Probe HolographIc REconstruction (SAPPHIRE) utilizes a chirped probe pulse, a diffractive optical element, a self-referenced interferometer, and an interference bandpass filter to achieve high-fidelity electron density measurements suitable for underdense plasmas that exhibit cylindrical symmetry. The method overcomes limitations in conventional diagnostics, such as reliance on shot-to-shot reproducibility, while capturing plasma dynamics on picosecond timescales with micron-level spatial resolution. The capabilities of SAPPHIRE are demonstrated through measurements of laser-driven plasma channels in helium–nitrogen gas jets. SAPPHIRE demonstrates the formation and expansion of plasma channels in a single shot and the propagation of supersonic ionization fronts while revealing shot-to-shot variations in the plasma profiles. Experimental results are validated against theoretical models and scaling laws, underscoring the robustness and accuracy of this technique. By enabling ultrafast, high-resolution plasma diagnostics in a single exposure, SAPPHIRE represents a transformative advancement in plasma measurement technology.

Grace, Elizabeth S. [Lawrence Livermore National L↗

Application of Langmuir Probe Method to the Atmospheric Pressure Discharge Plasma

The heat balance model in the probe tip applied to atmospheric pressure plasma is constructed. Considering the natural convective heat loss, the limitation of plasma density for probe application to such a plasma is estimated. The rough limit is about n{sub e} = 10{sup 18} m{sup -3}. Four kind of materials (Cu, SUS, W, Al) are used for probe tips, and are tested in DC atmospheric pressure discharge. Heat conductivity is found to be a more important property than melting point in design of probes in high pressure discharge. DC atmospheric pressure discharge plasma parameters are obtained with our test probes. Obtained density is the order of 10{sup 17} m{sup -3} and does not contradict with the above density limitation. Change of space potential in air/Ar plasma is also confirmed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characteristics of probe current harmonics based on various applied voltage waveforms in low temperature plasmas

The characteristics of probe currents induced by applying various probe voltage waveforms, such as sinusoidal, sawtooth, square, and triangular, were investigated at a floating potential. It was found that the measured probe currents have many harmonics depending on the voltage waveforms. This was mainly due to the nonlinearity of the sheath in the plasma and was analyzed using the fast Fourier transform and a circuit model. By applying a triangular voltage waveform to a probe, plasma parameters such as electron temperature and plasma density could be obtained and compared to those of a single Langmuir probe and a floating harmonic method.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of effective sheath width around cutoff probe in low-pressure plasmas

Previous studies indicated that the measurement results of microwave probes can be improved by applying the adequate sheath width to their measurement models, and consequently the sheath width around the microwave probe tips has become very important information for microwave probe diagnostics. In this paper, we propose a method for measuring the argon plasma sheath width around the cutoff probe tips by applying the circuit model to the cutoff probe phase spectrum. The measured sheath width of the cutoff probe was found to be in good agreement with the floated sheath width calculated from the Child-Langmuir sheath law. The physical reasons for a discrepancy between the two measurements are also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗