Search NASA⌕ Search

SEARCH · Search NASA

Results for “POLYSTYRENE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

242 records · Page 14

Spacecraft Smoke Detector Characterization with Reference and Smoke Aerosols

Performance testing of consumer smoke detectors requires specific facilities and experiments with smoldering and flaming emissions from different fuels. Smoke detectors for use in spacecraft are tested using similar setups with representative fuel materials. To simplify smoke detector testing, this study explored the use of laboratory-generated reference aerosols as transfer standards to evaluate smoke detector performance. Among the three tested reference aerosols, mineral oil particles were reproducibly generated with a Gemini smoke detector tester, dioctyl sebacate (DOS) particles were generated with a wide concentration range and flexible size distributions using an atomizer, while polystyrene latex(PSL) particles were difficult to produce with the high concentrations needed for smoke detector testing. Reference aerosols generated from 1.5%–100% DOS solutions and mineral oil covered the response range of six types of smoke aerosols generated by oxidative pyrolysis of spacecraft-relevant materials. Although no single reference aerosol can be used to simulate the response of different smoke detection technologies to different smoke aerosols within ±10% error, the relationship between reference and smoke aerosols derived from this study can be used to predict smoke detector responses to combustion aerosols.

Smoke↗

A 3D-printed Broadband Millimeter Wave Absorber

We present the design, manufacturing technique, and characterization of a 3D-printed broadband graded index millimeter wave absorber. The absorber is additively manufactured using a fused filament fabrication (FFF) 3D printer out of a carbon-loaded high impact polystyrene (HIPS) filament and is designed using a space-filling curve to optimize manufacturability using said process. The absorber's reflectivity is measured from 63 GHz to 115 GHz and from 150 GHz to 215 GHz and is compared to electromagnetic simulations. The intended application is for terminating stray light in Cosmic Microwave Background (CMB) telescopes, and the absorber has been shown to survive cryogenic thermal cycling.

Matthew Petroff↗

Machine-Learned Committor Functions for Reactive Molecular Dynamics

Reactive molecular dynamics (MD) is a powerful tool for atomistic-scale modeling of a diverse range of chemical processes. However, scaling these simulations to large systems and long times scales remains a challenge because of the complexity of the potential energy function required. The authors previously developed a heuristic approach, called REACTER, that incorporates reactivity in MD simulations in a less general but much more computationally efficient manner. REACTER uses standard, fixed valence force fields as the underlying potentialenergy surface for describing all interatomic interactions but adds a procedure for enforcing user-defined reactions that occur when certain geometric constraints on relative atomic positions are satisfied. Further, these bonding changes can be accepted or rejected with a probability related tothe local thermal energy. This work seeks to generalize this approach by replacing the set of user defined geometric constraints and energetic criteria with a committor function that specifies the probability of a reaction occurring on the basis of the local atomic configuration. The committor function is a useful mathematical tool for modeling rare events but, unfortunately, is very difficult to compute for realistic systems in a general way. This work describes a method for approximating the committor function using a machine learning approach, specifically a deep neural network trained with data from reactive MD and DFT-based dynamics simulations. This network is coupled to the existing REACTER protocol, as implemented in the LAMMPS MD package, and used to make on-the-fly predictions of reaction probabilities without the more extensive user input previously required. The new method is demonstrated using the polymerization of polystyrene as a case study. Although very dependent on the quality and quantity of training data, machine-learned committor functions show promise as a method for incorporating reaction probability from higher level calculations into highly scalable MD simulations.

polymer simulations↗

rHealth One Demonstration Aboard ISS: A Microfluidic Bioanalyzer Based on Sheath/Hydrodynamic Focusing Flow Cytometry

The Exploration Medical Capability (ExMC) element aims to provide astronauts with the means for their own health monitoring, diagnosis, and treatment during exploration missions. As space flight ventures further from earth, the need for autonomous medical care increases under greater constraints on size, mass, and resources. One pillar for diagnosis that crew would be separated from is laboratory analysis. Even now on ISS, blood samples must be collected and returned to earth for testing. In response, ExMC is assessing how assays for hematology, bone health, radiation exposure etc. could be addressed through commercial-off-the-shelf (COTS) and Small Business Innovation Research (SBIR) funded bioanalyzers that are miniaturizing lab technology. Since missions will reach distances where there are no timely replacements, validation on the International Space Station (ISS) is a necessary part of that assessment. In partnership with NASA Johnson Space Center (JSC) Immunology Lab and the Research Operations and Integration (ROI) element, ExMC conducted a technology demonstration on ISS of the rHEALTH ONE, a flow cytometry based bioanalyzer, to assess future devices based on this design. In flow cytometry, there are predominantly three ways to focus the cells (or particles) into a single file stream: hydrodynamic focusing, microcapillary, and acoustic focusing. The rHEALTH ONE utilizes the commercial standard, sheath-based hydrodynamic focusing. rHEALTH itself represents both a company and a suite of medical tools NASA has funded through SBIR grants towards the development of a promising diagnosis instrument for exploration missions. rHEALTH ONE is the interim version of the technology, functional as a benchtop analyzer and test bed for the next generation of rHEALTH in development. Several modifications were made to the rHEALTH ONE analyzer for operation in microgravity. For function, fluid management was key. A sheath-based analyzer uses sheath fluid to flow the sample, cleaning fluid to prevent biological contamination, and a reservoir to collect the liquid waste. The rHEALTH ONE analyzer uses bottles dependent on gravity to separate the air and liquid pathways and keep the liquids contained. It uses only 1 psig of air pressure to directly push the liquid through the device, requiring little-to-no resistance at inlet and outlet. A microtubing assembly with self-sealing luer connectors was designed – featuring 0.014 mm thick durable medical balloons to hold water inside the supply bottles – to create safe containment and easy access for the crew while maintaining the analyzer’s function. For safety, copper tape was added to the interior of the plastic housing to reduce electromagnetic interference, fluid and electrical connections were secured against vibration and leaks, and gaps were further sealed to ensure containment of the optical block and lasers. Water as the sheath and cleaning fluid and TOX 0 samples were used to reduce the biohazard risk to the crew. In May 2022, European Space Agency astronaut Samantha Cristoforetti demonstrated the rHEALTH ONE aboard ISS for its sample loading, flow cytometry, and data collection capability in microgravity. The JSC Immunology Lab provided flow cytometry expertise, designed the sample test protocol, and manufactured and benchmarked the flight samples on a ‘gold-standard’ flow cytometer. The analyzer was primed with water, purged of air, and four calibration solutions of polystyrene microparticles were tested to characterize its performance. Tightly controlled procedures and excellent execution prevented air bubble interference during air/water separation, fluid transfer, sample mixing and loading. Data showed a slight increase in signal noise on 3 of 5 channels and an anomaly of fluorophores migrating in one sample (confirmed by JSC post-flight). Flight results correctly detected the change in sample, matched the analyzer’s ground performance, and were consistent with the gold-standard’s ground results. Although areas were noted for improvement, these outcomes signified complete mission success.

R. S. Miller↗

3D Printed Materials Characterization for Rapid Prototyping and Plant Growth

Through KSC IRTD funding in 2022, this project brought a list of 18, 3D printed filaments into formal characterization testing to provide a reference for their behaviors under relevant applications. The project format set up a series of tests to expose 3D printed specimens. A total of 1,989 individual 3D printed test specimens were sent across KSC to be scrutinized by three laboratories to fulfill a multidisciplinary assessment of each material TRL. Testing started with 18 materials. Initially, seed germination assays in the PPA, sample materials were enclosed in petri dishes with lettuce seeds on damp germination paper. No significant impacts on lettuce seed germination were observed in this testing. Next, sample coupons were printed and sent for materials testing to the KSC Analysis/Mechanical and Environmental Testing Laboratory, where they were subjected to 14- and 30-day soak periods in solutions used to provide nutrients to plants or to sanitize hardware before and after use. Following a long soak typical of a 30-day plant growout in Hoagland’s solution, 14 materials gained more than 10% of their own mass. This indicated an increased potential for leaching or providing conditions that are not food safe. Materials that exceeded 15% absorption by mass were eliminated from further testing. Based off this result, the team continued with a core list of nine filaments to fulfill Tensile, Flexural, Biofilm formation, and plant growth testing. Those materials were PLA (Raise3D), ABS (Raise3D), PETG (PolyethyleneTerephthalate Glycol) (Raise3D), ASA (Acrylonitrile Styrene Acrylate) (Raise3D), PC (Polycarbonate) (Raise3D), TPU (Thermoplastic polyurethane)-95 (Raise3D), PLA Copper (Gizmodorks), PP (Polypropylene) (Braskem), and HIPS (High Impact Polystyrene) (Gizmodorks). Testing also quantified the spectral impact of using different color 3D printed surfaces in a growth chamber. The material used for spectral testing was PLA. Printing employed a standard surface texture representative of all materials. It was shown through Tensile Testing (ASTM D638-22) that the breaking force of a 3D printed part greatly varied depending on layer orientation. This is common through all materials, and demonstrates that the strength of a 3D printed component can be maximized by layering the material normal to the primary force on the part. Four-point flexural testing (ASTM D790) provided quantities of interest, Flexural modulus, Flexural strength, Flexural stress, and strain at break within a 5% strain limit from each of nine materials. Biofilm formation testing was conducted in the Molecular and Microbiological Laboratory. Testing completed on specimens from each material showed equal formation on the surface. Additional plant growth testing was conducted in the PPA beyond the initial germination testing. The final assessment documents that three materials (PLA, ABS, and PC) have reached TRL 6 through extensive testing, and ultimate end-to-end applied use in experimental or testing conditions (flight and ground). TRL 5 materials (ASA, TPU-95, PLA Copper, PP, PETG, and HIPS) have all been successfully applied in Research and Development for crop growth applications and are ready to be applied in formal testing. TRL 4 materials Nylon910, PLA Carbon Fiber, PPA CF, PPA Glass Fiber (GF), NinjaFlex, and P-filament 721 are materials that were able to be printed and tested, but have yet to show data meeting applied requirements. TRL 3 NylonX, Flex TPE-185, and Nylon were unable to be reliably printed to fulfill testing. These results provide researchers with reference for materials to use during plant growth experimentation, and also set a standard for future characterization work applying 3D printing and materials to testing, research, and experimentation.

Gioia Massa↗

Intact capture of hypervelocity projectiles

The ability to capture projectiles intact at hypervelocities opens new applications in science and technology that would either not be possible or would be very costly by other means. This capability has been demonstrated in the laboratory for aluminum projectiles of 1.6 mm diameter, captured at 6 km/s, in one unmelted piece, and retaining up to 95% of the original mass. Furthermore, capture was accomplished passively using microcellular underdense polymer foam. Another advantage of capturing projectiles in an underdense medium is the ability of such a medium to preserve a record of the projectile's original velocity components of speed and direction. A survey of these experimental results is described in terms of a dozen parameters which characterize the amount of capture and the effect on the projectile due to different capture media.

NASA Discipline Number 52-50↗