Search NASA⌕ Search

SEARCH · Search NASA

Results for “POWER SUPPLIES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Modeling and analyzing parasitic parameters in high frequency converters

This research focuses on electromagnetic interference (EMI) / electromagnetic compatibility (EMC) design and analysis in power electronics systems. To limit the EMI under the standards, different methods and strategies are investigated. Parasitic parameters of high frequency (HF) transformer are analyzed using a novel analytical method, finite element method (FEM), and experimental measurements for different structures and windings arrangements. Also, the magnetic field, electric field, electric displacement, and electric potential distribution are simulated and analyzed. Moreover, a high voltage system is considered and analyzed to improve the EMC. The EMI propagation paths are analyzed. The EMI noise level of the system is obtained and compared to the IEC61800-3 standard. To improve the EMC, the parasitic parameters of the transformer, as the main path of EMI circulation, are analyzed and optimized to block the propagation. Furthermore, the geometry structure of the HF transformer is optimized to lower the parasitics in the system. Three pareto-optimal techniques are investigated for the optimization. The models and results are verified by 3D-FEM and experimental results for several given scenarios. Furthermore, the EMC modeling and conducted EMI analysis are developed for a system including an AC-DC-DC power supply (rectifier and dual active bridge (DAB) converter). Moreover, the common mode (CM) EMI noise propagation through the system is discussed and the noise sources and effect of components on the noise are analyzed. Additionally, the CM impedance of different parts of the system and the noise levels are discussed. Finally, EMI attenuation techniques were applied to the system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Developing of Quaternary Pumped Storage Hydropower for Dynamic Studies

Quaternary pumped storage hydropower (Q-PSH) technology, as one of the new advanced-PSH technology, has been developed by taking advantage of Conventional-PSH (C-PSH) and Adjustable Speed-PSH (AS-PSH). By combining adjustable-speed pump unit and conventional hydropower turbine unit in the quaternary configuration, Q-PSH has the more competitive capability of providing fast power support in the future high renewable penetrated power system. Acting as energy storage (ES), Q-PSH provides promising power supply to deal with the uncertainty and variability from renewable energy generation. This paper focuses on the dynamic modeling of Q-PSH technology employing full-converter machine and the impact of Q-PSH on the frequency response in a system. The detailed model of Q-PSH is developed and implemented in the IEEE 14-bus system based on GE Positive Sequence Load Flow (PSLF) platform, which captures the dynamic of multiple operation modes, especially hydraulic short-circuit (HSC) operation mode. Several cases are set up to reveal the advantages of Q-PSH technology when power electronic based renewable energy generation is deployed in the system. Sensitivity studies of the controller in pump governor show the impact of parameters in pump response performance. The comparison case illustrates the impact of frequency response provided by the Q-PSH in the system.

dynamic modeling↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - Simulated Marine Hydrokinetic Tidal Turbine

The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset is part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with other energy technologies. This dataset contains inputs and outputs from simulations of a floating marine hydrokinetic turbine over approximately half a tidal cycle (~6.6 hours). Inflow conditions were derived from field measurements in Alaska’s Cook Inlet and represent a tidal environment in which the current speed ramps from near 0 m/s to a peak of 3 m/s and back. The original acoustic doppler current profiler dataset is publicly available on the Marine and Hydrokinetic Data Repository. In a full tidal cycle, the flow reverses and the rotor would reorient; this reversal was not modeled. In the Cook Inlet campaign , turbulence intensity was similar in both directions. Two inflow cases are included. In the first case, labeled “raw” in the files, the measured current time series was used directly in the InflowWind module of OpenFAST. Speed and direction were applied as a function of time and elevation, uniformly in the horizontal direction. With full spatial coherence, this approach captures high turbulent variability and results in pronounced power fluctuations, so it is considered a conservative, near-worst-case representation of loading. In the second case, labeled “average” in the files, a 30-minute moving average was applied to extract the slowly varying mean speed. The residual fluctuations about this mean were used to generate spatially varying, full-field turbulence inputs with TurbSim, giving a more physically realistic representation of the inflow across the rotor disk. Two random realizations were used to produce distinct inflow conditions for two OpenFAST simulations representing a two-turbine array. The same turbulence intensity is applied across the full time series, producing larger fluctuations at the start and end, where the mean speed is low. The second case is the more appropriate framework for performance and power assessment but overpredicts turbulence at lower flow speeds and underpredicts it at higher speeds. As the floating platform moves and the rotor changes its x-position, Taylor’s frozen turbulence hypothesis used by InflowWind assumes a constant rather than a time-varying mean velocity, introducing some inaccuracy in the velocity plane sampling. The turbine modeled is the 500-kW Reference Model 1, a horizontal-axis two-bladed hydrokinetic turbine on a four-column floating semisubmersible substructure . Simulations were performed using OpenFAST v4.1 with the Reference Open Source Controller (ROSCO) v2.10. All input files required to reproduce the simulations are included. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel . This unit supports up to 2.5 MW, but NLR has only a single 1.25-MW stack. The datasets report hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. The system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operating current of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The simulated tidal turbine time series data was translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz. Each zip file represents a single tidal electrolysis experiment and is named: {technology}_{inflow method}_{number of 500 kW tidal turbines connected} For instance, “tidal-500kW-RM1_average_2.zip” is a 6-hour experiment using the 500-kW tidal reference model, scaled by 2x (1-MW) to better match the electrolyzer maximum of 1.25MW, fed with the 30-minute moving average current case. Each zip folder contains the following files: A .csv file of raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wave power. A .csv file combines all tidal profiles as "combined_tidal_experiments.csv." A separate experiment, “characterization_200.zip,” shows the MC250 electrolyzer steady-state response with 30-minute load steps over 5 hours and is accessible with this entry.

08 HYDROGEN↗

Commissioning of a modulated pulse-power magnetron sputtering system for depositing niobium thin films

A modulated pulse-power magnetron sputtering system (MPPMS) was commissioned and used to deposit niobium on copper. MPPMS utilizes a modulated pulse train with high peak-to-average energy ratios, thereby increasing the energy density leading to the production of the energetic ions. The MPPMS modulator was designed and constructed based on large voltage/current IGBT modules, which can be externally modulated, produce bi-polar waveforms, and are readily available. A high voltage power supply provides moderate current to the IGBT module to create the precise pulse structure. The MPPMS system was used to deposit ~1 mm thick, niobium film on a copper substrate held at ~77 K to minimize Nb atom surface diffusion and maximize intrinsic film energy. Finally, the Nb film had an average grain size of ~8 nm.

42 ENGINEERING↗

Modernizing the Legacy Fission Wire Measurement System for the Advanced Test Reactor-Critical Facility

Operational lifetime extensions of existing research reactors have emphasized the need for refurbishment, replacements, and upgrades to supporting equipment and instrumentation. The Advanced Test Reactor (ATR) at Idaho National Laboratory (INL), which entered service in 1967, has recently completed the sixth core internals change-out and has scheduled operations until at least 2040. Reactor maintenance and operational risk management is critically important in the research reactor community, however supporting measurement systems sometimes get overlooked when maintenance is planned. The Fission Wire Measurement System (FWMS) is a custom measurement system designed in the 1960s to measure the beta-particle activity of irradiated uranium-aluminum fission wires. This measurement is conducted to determine the fission rate profile of the Advanced Reactor Test Critical (ATR-C) facility. The ATR-C is an open-pool, low-power test reactor that was purpose driven to resemble ATR and is used to qualify experiment configurations and verify core models prior to full-power experiment irradiations in ATR. A power distribution measurement in ATR-C uses uranium-aluminum wires that are distributed throughout the ATR-C core to validate simulation and modeling results. These measurements require 340 to 1500 wires to be irradiated and measured within a 12-hour window. The activity of the wires is measured in the required time with the FWMS, which was put into service in 1965 at the Radiation Measurements Laboratory (RML). The system consists of 4 measurement channels and one reference channel, each with a 2-pi proportional gas flow detector and the measurement channels each have an automated sample changer. This legacy system is crucial to the continued operations of ATR and has undergone some minor hardware upgrades since 1965, however the system presently relies on custom control boards, custom gas ion chambers, analog amplifiers/discriminators, and a user interface (UI) for the system written in outdated code. Much of the equipment and software is custom with no commercial replacements or support and limited documentation. The existing control software requires an operating system that is no longer supported, creating more vulnerabilities to continued operations. A project is underway with a third-party vendor to design, build, and document a new control and data acquisition system (CDAS) for the FWMS. The new upgrade will replace the control system, computer, UI, sample changer motors, and main power supply while maintaining the interface with existing detector hardware. The upgraded system will be operated in parallel with the current hardware and software to conduct validation testing. This equipment upgrade demonstrates the commitment at ATR to ensuring successful operations and potential future research reactors at INL.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Final Technical Report Wireless Microsensors System for Monitoring Deep Subsurface Operations

This final technical report describes the main findings of the project Wireless Microsensors System for Monitoring Deep Subsurface Operations (FE0031850). The project was part of the U.S. Department of Energy National Energy Technology Laboratory FOA 1998 program to develop new sensor systems for direct observation of parameters associated with CO2 injection and to provide data collection without being disruptive to operations. The overall DOE program was aimed at developing and validating innovative transformational sensor systems, amenable for integration with autonomous intelligent monitoring systems, that are capable of being deployed within the casing annulus and do not have casing perforation or wires/cables in the annulus for installation, power supply, or data transmission needs. Project accomplishments included 1) design and fabrication of a wireless downhole sensor system to monitor parameters for CO2 storage, 2) field testing of the sensor system in two legacy oil & gas wells, and 3) development of an analysis approach that validates the measurements and demonstrates the application of the technology to depict CO2 movement in the subsurface. The project leveraged new sensor technologies along with specialized wellbore telemetry, deployment, and analysis methods designed to address the challenges and risks related to CO2 storage in the subsurface. Results from field testing were a mixture of successes and challenges. The temperature sensor rings, installation procedures in legacy oil & gas wells, wireless powering demonstration, automated data collection, and material compatibility were successful. The wireless data transfer through cement to the wellhead via the sensor relays was not functional beyond the first relay. Consequently, work in the last year of the project included some additional testing of data transmission through different materials along with modeling and analysis of field data for CO2 monitoring applications. This work suggested there are options like polymer cements and open hole annuli that may allow point-to-point transmission along the borehole. The techno-economic analysis suggests that the sensor system is ~40% less expensive than fiber optic distributed temperature system. Modeling of CO2 storage applications suggests temperature can provide an indicator of CO2 saturation but would be best combined with pressure sensors.

47 OTHER INSTRUMENTATION↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Solar PV

The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) research platform. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence data centers and other variable loads. This dataset entry describes the behavior of a 1.25-MW proton exchange membrane MC250 electrolyzer system, manufactured by Nel Hydrogen , [1] when fed historical data generated by the 430-kW, fixed-axis solar photovoltaic (PV) array located at NLR’s Flatirons Campus. (While the electrolyzer balance of plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack.) Solar PV power output data for the 2020 calendar year were categorized on a daily basis by total energy generation and standard deviation. Each day was then ranked by these metrics, and the 25th, 50th, and 100th percentiles were selected. The 75th percentile day did not exhibit sufficient variability to make for a valuable experiment. A similar process was used for the related historical wind dataset . [2] The historical days in 2020 that represented these percentiles are Dec. 19, March 29, and May 4, respectively. The entire solar day’s power profile was then fed through the MC250 electrolyzer. Due to its length, the 100th percentile day experiment was split into two parts, and the final 3 hours of the solar day were not captured. These final 3 hours contained no spikes or dips of interest and simply represented a slow decay of input solar power. Also, a single timestamp (13:13:47 on Jan. 14, 2026) was lost in the hydrogen system supervisory control and data acquisition. Finally, during the 25th percentile experiment (solar day Dec. 19, 2020) data recording was lost from 11:00:13 to 11:14:45. The roughly 15 minutes of the solar profile were rerun at the end of the experiment and spliced into this time slot during post-processing. The electrolysis system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operation of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical solar profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. For more details on the statistical analysis process, see the slide deck “Public Reference Data for Megawatt-Scale Hydrogen Electrolysis: NLR Historical Solar PV Analysis and Profile Generation” accessible with this data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single solar PV electrolysis experiment and is formatted as: {technology}_{percentile}_{scaling factor} For instance, “solarPV-430kW_25_2x.zip” reports the experiment using the 25th percentile solar data from the historical 2020 solar PV dataset, scaled to 200%. Scaling factors were applied to the generated solar PV power output files to more closely match the 1.25-MW capacity of the electrolyzer. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and solar power input. A PDF file detailing the historical solar data statistical analysis used to generate the solar profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all experiments combined into one dataset labeled "combined_solarPV_experiments.csv". [1] nelhydrogen.com/product/mc-series-electrolyser . [2] data.nlr.gov/submissions/316 .

08 HYDROGEN↗

Enhancing Radionuclide Production Capabilities at the Duke University Medical Center Cyclotron with a Focus on Astatine-211

Radionuclides play an important role in a diverse array of fields including physics, chemistry, agriculture, materials science, national security, medical research and patient care. Establishing a reliable domestic supply of key radionuclides is critical to our national competitiveness in these areas. Regarding medical applications, targeted alpha-particle therapy (TAT) has become of great interest to basic researchers and clinicians alike and is emerging as a valuable and cost-effective approach for cancer treatment. Unfortunately, progress in TAT, particularly with regard to its clinical translation, has been severely hampered by the limited availability of the most promising radionuclides at a reasonable cost, and with appropriate chemical and radiochemical purity. In this project, we have attempted to address this problem by focusing on production of the 7.2-h half-life α-particle emitter, 211 At, which has long been considered to be one of the most promising radionuclides for TAT. We note that he critical importance of improving the supply of 211 At in the United States was noted in the Funding Opportunity Announcement related to this project. At Duke University, we have a CS-30 cyclotron that is one of the few accelerators in the United States that has an alpha-particle beam that has enough energy to make useful quantities of 211 At. With this cyclotron, we have been able to produce more 211 At than anywhere else in the world because of our unique internal cyclotron target system. However, the CS-30 cyclotron is nearly 40 years old and was no longer reliable. In addition, its operation required considerable skill, largely because it had analog control systems, and vital parts including old-fashioned power supplies, were becoming unavailable. For these reasons, the current project was undertaken to evaluate all the subsystems of the CS-30 cyclotron and replace, repair, and update them. With help from our consultant, Ionetix, this has now been accomplished. We believe that because of this work, the CS-30 can reliably supply 211 At for basic research and clinical trials both at Duke and beyond.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TASTI-GRID: An Overview of West Virginia’s Grid Resilience Challenges

West Virginia’s legacy as a top power producer with a legacy of mining and natural gas is well-known across the country. A state with historic underinvestment, vulnerability to natural hazards, and a large rural population – much of West Virginia’s critical energy infrastructure is beyond its recommended lifecycle at 75+ years old. West Virginian’s are feeling the effects of neighboring Virginia’s data center growth, as its grid interconnectedness with neighboring states have impacted energy affordability as power supply has not kept up with demand. The state aims to attract data centers to improve economic development, however, the age of infrastructure, utility reliability, weather-induced major outages, and cost of proposed improvements compound West Virginia’s resilience challenges.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Accelerating nuclear-integrated data center pursuits in the USA: SWOT analysis, power-thermal management strategies and demonstration plan

Here, this study explores the increasing interest in leveraging nuclear power to meet the escalating energy demands of data centers in the United States (U.S.) by focusing on key factors that contribute to accelerated deployment. The study highlights the importance of N+1/N+2 power supplies (where N is the required number of units), outlines research and innovations in nuclear-integrated data center thermal management and demonstration plan. It also provides updates about status and costing of various reactor system designs. A summarized strengths, weaknesses, opportunities, and threats (SWOT) analysis shows the potential options for grid connectivity, reactors, and site selection. Suitable site discussions consider land and water availability, grid access, and optical fiber connectivity, and the study presents graded prospects for Department of Energy (DOE) sites with a specific example. Community engagement and partnerships are emphasized, particularly the roles of local government, federal agencies, utilities, and data center industry partners, which are crucial for accelerating deployment, business outreach, and approvals. The study provides actionable insights for stakeholders to accelerate the deployment of nuclear-powered data centers.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Nanosynthesis by atmospheric arc discharges excited with pulsed-DC power: a review

Plasma technology is actively used for nanoparticle synthesis and modification. All plasma techniques share the ambition of providing high quality, nanostructured materials with full control over their crystalline state and functional properties. Pulsed-DC physical/chemical vapour deposition, high power impulse magnetron sputtering, and pulsed cathodic arc are consolidated low-temperature plasma processes for the synthesis of high-quality nanocomposite films in vacuum environment. However, atmospheric arc discharge stands out thanks to the high throughput, wide variety, and excellent quality of obtained stand-alone nanomaterials, mainly core–shell nanoparticles, transition metal dichalcogenide monolayers, and carbon-based nanostructures, like graphene and carbon nanotubes. Unique capabilities of this arc technique are due to its flexibility and wide range of plasma parameters achievable by modulation of the frequency, duty cycle, and amplitude of pulse waveform. The many possibilities offered by pulsed arc discharges applied on synthesis of low-dimensional materials are reviewed here. Periodical variations in temperature and density of the pulsing arc plasma enable nanosynthesis with a more rational use of the supplied power. Parameters such as plasma composition, consumed power, process stability, material properties, and economical aspects, are discussed. Lastly a brief outlook towards future tendencies of nanomaterial preparation is proposed. Atmospheric pulsed arcs constitute promising, clean processes providing ecological and sustainable development in the production of nanomaterials both in industry and research laboratories.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Protection and Restoration Solutions to Reliable and Resilient Integration of Grid-connected PV Installations and Distributed Energy Resources: Design, Testbed, Proof of Work and Impact Studies (Final Report)

To gain a better understanding of the complex transients in a utility grid with a large number of solar PV installations coupled by PWM inverters during the protection and restoration period of the power grid, in this project a kW-level experimental system with dominating inverter-based resources and a hardware-in-loop simulation system with transmission and distribution models, as well as several SEL protective relays have been built and used. The major research findings of the project are summarized below in two perspectives: Experimental research: A self-organized ultra-high frequency solitary waveform is discovered and demonstrated in the hardware experimental system. Despite the familiarities, such a solitary waveform is distinct from any harmonics, transient, or resonance waves in that, it is 1) non-dispersive over time and space, 2) not associated with any active source or the linear superposition of sources, 3) half-cycle asymmetric, 4) not responding to filters or change of system characteristic resonance frequency, 5) ubiquitous as it occurs simultaneously everywhere in the system from DC supply, power lines, and the utility grid, and 6) explosive through tripping the protection or damaging susceptible devices or circuits. Analytical study: The nature of such a new waveform and an analytical explanation of its formation are studied based on related physics and non-linear science principles, with the following highlights: 1) such a new waveform follows the solutions to the Non-linear Schrödinger equation, so the classic linear perturbation theory is unable to explain or predict such a unique waveform as confirmed with the research team of RTDS; 2) the critical condition of occurrence of such a waveform is derived, which indicates that the breakings of solitary wave is a system synchronous issue between the utility grid in the 60Hz phasor domain and duty-ratio modulation of DC sources in the inverter switching frequency domain; 3) such a waveform carries energy mass so it could be detrimental; 4) such a waveform is deceiving as it is not readily detectable in the energy propagation direction by the primary protection equipment, while it is detrimental in the perpendicular direction of energy propagation, i.e. voltage direction. Thus, it has more likely challenges to the second primary equipment and devices, particularly at the weakest link and point such as aging insulation and inappropriate setting of susceptible devices. Therefore, such a waveform can be easily ignored in the aftermath investigation. The intellectual merits: The experimental discovery reveals certain unfamiliar transient phenomena that could challenge the integration of large-scale grid-connected solar PV installation during the group ride-through period of solar PV installations, commissioning of large-solar farms, or dramatic change of solar radiation conditions. Particularly, the research findings suggest that the occurrence of the unfamiliar transient phenomena is uniquely associated with the inverter-based solar PV installation, which is less likely to happen for rotary energy systems. The physics and non-linear science-based research work laid down an analytical path to the challenging transient stability problems including those that have been observed currently and future calls. Both experimental and analytical research results explain the limitation of many current research effects including some DoE research undertakings as well as possible solutions. The broader impacts: The research outcome of the project advances the understanding of the possible transient problems for the integration of inverter-based solar PV installation. It also highlights the theoretical and technical barriers for applying the conventional theory and technology to design and implement countermeasures against their adverse impacts of the large-scale solar PV installation and operation on grid reliability and security. More broadly, the research outcomes have shed some light on the open, fundamental challenges in the integration of large-scale solar photovoltaic energy into current and next-generation power grids across the country, and worldwide. The advanced physics and non-linear science-based analysis open up a path to harmonization of the renewables for societal energy needs via building a resilient and sustainable electric power infrastructure.

14 SOLAR ENERGY↗

Northwest Combined Heat and Power Technical Assistance Partnership: Final Scientific/Technical Report

During the years of 2018 through 2023, The Washington State University Energy Program (WSU EP) operated the Northwest Combined Heat and Power Technical Assistance Partnership under contract to the US Department of Energy’s Advanced Manufacturing Office (AMO), a part of DOE’s larger Office of Energy Efficiency and Renewable Energy. This contract provided direction and funding for providing technical outreach, information and technical/economic analysis services in support of expanding development of Combined Heat and Power (CHP) over a four state region in the Pacific Northwest. The states served included Alaska, Idaho, Oregon and Washington. During the duration of this contract, the WSU EP delivered performed specific assigned tasks and provided services of various generally prescribed types, with the overall goal of increasing adoption of CHP as an efficient heat and power supply in the region. Indications – though not formally evaluated to our knowledge – are that this goal was achieved. Over many years, the WSU team has provided support for CHP developments in these states under similar previous Department of Energy contracts, and many such projects have been built. While the early-phase outreach, education and techno-economic assessments that the NW CHP TAP provides rarely immediately result in project construction, there is no doubt that the WSU EP team has had substantial influence in the construction of a number of important CHP projects in the region. Examples of projects implemented directly under the current team’s guidance and services during this contract cycle include an 875 kilowatt biomass fueled CHP system installed at the University of Idaho, and 5 megawatt natural gas fueled CHP system at the University of Montana ( UM Breaks Ground on New Power Facility, Slashes Emissions 30% (umt.edu) ). Many other CHP systems recently installed are also either directly or at least partially the result of information and technical services provided by the team. Finally, though much more difficult to quantify and less glamorous, the team has helped countless organizations to understand CHP and determine whether and how CHP may be a fit for them, before they consider paying for engineering services. Whether the ultimate outcome has been to include CHP or not, the expert skills provided by the NW CHP TAP team have provided real value to these organizations considering this relatively complex technology. Over the duration of the contract our team provided 71 Initial Technical Assessments and 17 Advanced Technical Assessments; 53 End-User Engagements and 33 Stakeholder Engagements of various types; 42 Technical Profiles (Project Profiles, Program Profiles and Policy Profiles), and produced 14 technical articles for the Department of Energy. Unfortunately, these quantities provide no measure of the value that the team has provided. Only our clients can judge that, and we are confident that they are pleased with the benefits we have offered them.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Optimal Sizing of Movable Energy Resources for Enhanced Resilience in Distribution Systems: A Techno-Economic Analysis

This article introduces a techno-economic analysis aimed at identifying the optimal total size of movable energy resources (MERs) to enhance the resilience of electric power supply. The core focus of this approach is to determine the total size of MERs required within the distribution network to expedite restoration after extreme events. Leveraging distribution line fragility curves, the proposed methodology generates numerous line outage scenarios, with scenario reduction techniques employed to minimize computational burden. For each reduced multiple line outage scenario, a systematic reconfiguration of the distribution network, represented as a graph, is executed using tie-switches within the system. To evaluate each locational combination of MERs for a specific number of these resources, the expected load curtailment (ELC) is calculated by summing the load curtailment within microgrids formed due to multiple line outages. This process is repeated for all possible locational combinations of MERs to determine minimal ELC for each MER total size. For every MER total size, the minimal ELCs are determined. Finally, a techno-economic analysis is performed using power outage cost and investment cost of MERs to pinpoint an optimal total size of MERs for the distribution system. To demonstrate the effectiveness of the proposed approach, case studies are conducted on the 33-node and the modified IEEE 123-node distribution test systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fluid dynamic simulation and analysis of water-cooling systems for the Electron-Ion Collider

The Electron-Ion Collider is the newest large-scale project at Brookhaven National Laboratory. The collider’s purpose is to provide further advancements in the knowledge of the universe’s origin by accelerating particles near the speed of light. Our project for this 3.8 km ring was to create a thermal hydraulic steady-state simulation design of the water-cooling system to be cost-effective and energy efficient, as envisioned by Charlie Foltz, the EIC Infrastructure Division Director. The system would include a supply and return header, which cools several thousand components of the ring. The water would then be returned and cooled down using a system of cooling towers and plate and frame heat exchangers. Due to the size of the system and the complexity of the network analysis, a fluid dynamic simulation software, AFT Fathom, was used. Since previous methods of maintaining systems relied on building upon smaller real-life models and implementing empirical data, this flow model was unique and first of a kind in the domain of accelerator design, construction and operation. Therefore, our hydraulic team piloted a new method to perform network analysis on a large scale cooling system. We successfully created several test scenarios for system behavior in a shorter time compared to the method of performing hand calculations. Cooling specifications for heat rejection, pressure drop, flow rate, and pipe sizing were changed based on the individual systems of the vacuum, radio frequency (RF), magnet and power supply, and cryogenics sections. Finally, we used DOE guidelines to perform life-cycle cost analysis with net present value and carbon saving analysis on the systems where pipe size could be optimized.

43 PARTICLE ACCELERATORS↗

OPERATING EXPERIENCE AND ITS RELATIONSHIP TO EMBEDDED DIGITAL DEVICES IN SAFETY SYSTEMS

Interest in embedded digital devices (EDDs) for monitoring and providing control of components is increasing and the added functionality digital brings such as diagnostics, displays, control functions is welcomed in both the nuclear and other industries. As a result, pure analog-based components continue to disappear from the industrial I&C marketplace. Equipment with EDDs, also known by related terms such as smart devices, intelligent devices, and digital devices of limited functionality, can include sensors, breakers, priority logic modules, time delay relays, pumps, valve actuators, motor control centers, and uninterruptible power supplies. Not only is equipment consisting of analog and older digital technology being replaced with commercial grade products containing EDDs, but EDDs can also be retrofitted to work with existing components. EDDs may be installed physically within a component, such as in a relay. There are also external devices that some would not consider an EDD, but that operate in almost all technical ways identically to one internal to a component such as in a valve controller. In fact, the digital portions may be located hundreds of feet from the actual component.Due to the potential of being used in an identical manner and without alteration from their application in other industries, operating experience (OpE) for EDDs may be much more applicable than in the case of other more system level devices. Clear separation and independence of functionality provided with EDDs may also allow greater applicability of existing OpE from industry for changes that can be shown not to affect its safety function. However, OpE also demonstrates issues with different conditions between other industries and nuclear power plants, such as issues with undeclared changes or undeclared digital devices and the new failure modes they may introduce, issues with the reporting of OpE in industry, and a lack of transparency into OpE for EDDs.Understanding and addressing these issues will be key in the future use of EDDs in nuclear power plants, but failure rate data is difficult to obtain for EDDs, and lessons learned from the use of EDDs are difficult to collect and identify.Key words: embedded digital device, smart device, operating experience, failure modes

Muhlheim, Michael↗

Hierarchical Distribution System Adaptive Restoration with Diverse Distributed Energy Resources

Distributed energy resources (DERs) can be utilized as alternative power sources for fast service recovery in cases of distribution system outages. However, the diverse characteristics and stochastic nature of DERs impose challenges on the optimal operation of di-verse resources during the restoration phase. Here, we introduce a hierarchical structure to coordinate distribution system entities and propose an adaptive restoration strategy to sustain a reliable power supply to outage loads in an unbalanced distribution system utilizing DERs. An efficient system reconfiguration model is developed to guarantee the radiality of restoration islands. The flexibility of DERs is evaluated by a novel method that focuses on the cumulative energy consumption, the superiority of which is also proven. Model predictive control (MPC) is adopted to enable the adjustment of system topology and DER operation strategies based on up-to-date data. The performance of the proposed restoration model is validated on a modified IEEE 123-bus test system. Moreover, the effectiveness of the proposed novel flexibility assessment and the MPC-based adaptive restoration strategy are verified through comparative studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗