Search NASA⌕ Search

SEARCH · Search NASA

Results for “PRISM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Laboratory Testing and Performance Verification of the CHARIS Integral Field Spectrograph

The Coronagraphic High Angular Resolution Imaging Spectrograph (CHARIS) is an integral field spectrograph (IFS) that has been built for the Subaru telescope. CHARIS has two imaging modes; the high-resolution mode is R82, R69, and R82 in J, H, and K bands respectively while the low-resolution discovery mode uses a second low-resolution prism with R19 spanning 1.15-2.37 microns (J+H+K bands). The discovery mode is meant to augment the low inner working angle of the Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) adaptive optics system, which feeds CHARIS a coronagraphic image. The goal is to detect and characterize brown dwarfs and hot Jovian planets down to contrasts five orders of magnitude dimmer than their parent star at an inner working angle as low as 80 milliarcseconds. CHARIS constrains spectral crosstalk through several key aspects of the optical design. Additionally, the repeatability of alignment of certain optical components is critical to the calibrations required for the data pipeline. Specifically the relative alignment of the lens let array, prism, and detector must be highly stable and repeatable between imaging modes. We report on the measured repeatability and stability of these mechanisms, measurements of spectral crosstalk in the instrument, and the propagation of these errors through the data pipeline. Another key design feature of CHARIS is the prism, which pairs Barium Fluoride with Ohara L-BBH2 high index glass. The dispersion of the prism is significantly more uniform than other glass choices, and the CHARIS prisms represent the first NIR astronomical instrument that uses L-BBH2as the high index material. This material choice was key to the utility of the discovery mode, so significant efforts were put into cryogenic characterization of the material. The final performance of the prism assemblies in their operating environment is described in detail. The spectrograph is going through final alignment, cryogenic cycling, and is being delivered to the Subaru telescope in April 2016. This paper is a report on the laboratory performance of the spectrograph, and its current status in the commissioning process so that observers will better understand the instrument capabilities. We will also discuss the lessons learned during the testing process and their impact on future high-contrast imaging spectrographs for wavefront control.

Coronagraphic High Angular Resolution Imaging Spec↗

IR Spectrometer Using 90-Degree Off-Axis Parabolic Mirrors

A gated spectrometer has been designed for real-time, pulsed infrared (IR) studies at the National Synchrotron Light Source at the Brookhaven National Laboratory. A pair of 90-degree, off-axis parabolic mirrors are used to relay the light from an entrance slit to an output recording camera. With an initial wavelength range of 1500–4500 nm required, gratings could not be used in the spectrometer because grating orders would overlap. A magnesium oxide prism, placed between these parabolic mirrors, serves as the dispersion element. The spectrometer is doubly telecentric. With proper choice of the air spacing between the prism and the second parabolic mirror, any spectral region of interest within the InSb camera array’s sensitivity region can be recorded. The wavelengths leaving the second parabolic mirror are collimated, thereby relaxing the camera positioning tolerance. To set up the instrument, two different wavelength (visible) lasers are introduced at the entrance slit and made collinear with the optical axis via flip mirrors. After dispersion by the prism, these two laser beams are directed to tick marks located on the outside housing of the gated IR camera. This provides first-order wavelength calibration for the instrument. Light that is reflected off the front prism face is coupled into a high-speed detector to verify steady radiance during the gated spectral imaging. Alignment features include tick marks on the prism and parabolic mirrors. This instrument was designed to complement single-point pyrometry, which provides continuous time histories of a small collection of spots from shock-heated targets.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nano-scale microstructure damage by neutron irradiations in a novel Boron-11 enriched TiB 2 ultra-high temperature ceramic

Ultra-high temperature transition-metal ceramics are potential candidates for fusion reactor structural and plasma-facing components. We reveal the irradiation damage microstructural phenomena in Boron-11 enriched titanium diboride (TiB 2 ) using mixed-spectrum neutron irradiations, combined with state-of-art characterization using transmission electron microscopy (TEM) and high resolution TEM. Irradiations were performed using High Flux Isotope Reactor at ~220 and 620 °C up to 2.4 x 10 25 n.m -2 (E > 0.1 MeV). The calculated dose including contribution from residual Boron-10 ( 10 B) transmutation recoils, was ~4.2 displacements per atom. TiB 2 is susceptible to irradiation damage in terms of dislocation loop formation, cavities and anisotropic swelling induced micro-cracking. At both 220 and 620 °C, TEM revealed dislocation loops on basal and prism planes, with nearly two orders of magnitude higher number density of prism-plane loops. HRTEM, electron diffraction and relrod imaging revealed additional defects on {10$ \overline{1}\ $0} planes, identified as faulted prism-plane dislocation loops. High defect cluster density on prism planes will induce a-lattice parameter swelling of TiB 2 , as reported in literature. This anisotropic lattice parameter swelling induced grain boundary micro-cracking, the extent of which decreased with increasing irradiation temperature. The dominance of irradiation defect clusters on prism planes is different than typical hexagonal ceramics where dislocation loops predominantly form on basal planes, causing c-lattice parameter swelling. Helium generation and temperature rise from the transmutation of residual 10 B resulted in matrix and grain boundary cavities for the irradiation at 620 °C. In conclusion, the study additionally signifies isotopic enrichment as a viable approach to produce transition-metal diborides for potential nuclear structural applications.

36 MATERIALS SCIENCE↗

Phase diagram of SrO-InO{sub 1.5}-CoO{sub x} and a new compound Sr{sub 3}In{sub 0.9}Co{sub 1.1}O{sub 6}

Sr{sub 3}In{sub 0.9}Co{sub 1.1}O{sub 6}, isostructural to Ca{sub 3}Co{sub 2}O{sub 6}, is revealed by the study of the phase relations in the system SrO-InO{sub 1.5}-CoO{sub x} (1000 {sup o}C). The structure of Sr{sub 3}In{sub 0.9}Co{sub 1.1}O{sub 6} is refined by the combination of powder X-ray and neutron diffraction. Sr{sub 3}In{sub 0.9}Co{sub 1.1}O{sub 6} crystallizes in a trigonal lattice with the cell parameters a=b=9.59438(3) A, c=11.02172(4) A with the space group R-3c. Its structure possesses 1D (In/Co)O{sub 3} chains running along the c-axis constructed by alternating face-sharing CoO{sub 6} octahedra and (In{sub 0.9}Co{sub 0.1})O{sub 6} trigonal prisms. The co-occupation of In{sup 3+} and Co{sup 3+} at the trigonal prismatic site is evidenced by elementary analysis and determined by the structure refinement. Sr{sub 3}In{sub 0.9}Co{sub 1.1}O{sub 6} is paramagnetic, and the susceptibility is consistent with the occupation of Co{sup 3+} at 10% of the trigonal prismatic positions in a high spin state (HS, S=2). The HS Co{sup 3+} is well separated by diamagnetic CoO{sub 6} octahedra and InO{sub 6} trigonal prisms and shows a g factor of 2.0 in the magnetic measurements. -- Graphical abstract: Sr{sub 3}In{sub 0.9}Co{sub 1.1}O{sub 6} possesses 1D chains constructed by alternating face-sharing CoO{sub 6} octahedra and (In{sub 0.9}Co{sub 0.1})O{sub 6} trigonal prisms. The high spin Co{sup 3+} (S=2) in trigonal prism shows a g factor of 2.0. Display Omitted Research highlights: {yields} Phase diagram of SrO-InO{sub 1.5-}CoO{sub x} at 1000 {sup o}C in air atmosphere is presented. {yields} A new compound Sr{sub 3}In{sub 0.9}Co{sub 1.1}O{sub 6} that is isostructural to Ca{sub 3}Co{sub 2}O{sub 6} is revealed. {yields} 1D chain is formed by alternating face-sharing CoO{sub 6} octahedra and (In{sub 0.9}Co{sub 0.1})O{sub 6} trigonal prisms.{yields} Co{sup 3+} at trigonal prismatic site is in high spin state (S=2) with a g factor of 2.0.

36 MATERIALS SCIENCE↗

A Fast Algorithm for Scanning Transmission Electron Microscopy Imaging and 4D-STEM Diffraction Simulations

Scanning transmission electron microscopy (STEM) is an extremely versatile method for studying materials on the atomic scale. Many STEM experiments are supported or validated with electron scattering simulations. However, using the conventional multislice algorithm to perform these simulations can require extremely large calculation times, particularly for experiments with millions of probe positions as each probe position must be simulated independently. Recently, the plane-wave reciprocal-space interpolated scattering matrix (PRISM) algorithm was developed to reduce calculation times for large STEM simulations. Here, we introduce a new method for STEM simulation: partitioning of the STEM probe into “beamlets,” given by a natural neighbor interpolation of the parent beams. This idea is compatible with PRISM simulations and can lead to even larger improvements in simulation time, as well requiring significantly less computer random access memory (RAM). We have performed various simulations to demonstrate the advantages and disadvantages of partitioned PRISM STEM simulations. We find that this new algorithm is particularly useful for 4D-STEM simulations of large fields of view. We also provide a reference implementation of the multislice, PRISM, and partitioned PRISM algorithms.

97 MATHEMATICS AND COMPUTING↗

TH-A-BRF-08: Deformable Registration of MRI and CT Images for MRI-Guided Radiation Therapy

Purpose: To evaluate the quality of a commercially available MRI-CT image registration algorithm and then develop a method to improve the performance of this algorithm for MRI-guided prostate radiotherapy. Methods: Prostate contours were delineated on ten pairs of MRI and CT images using Eclipse. Each pair of MRI and CT images was registered with an intensity-based B-spline algorithm implemented in Velocity. A rectangular prism that contains the prostate volume was partitioned into a tetrahedral mesh which was aligned to the CT image. A finite element method (FEM) was developed on the mesh with the boundary constraints assigned from the Velocity generated displacement vector field (DVF). The resultant FEM displacements were used to adjust the Velocity DVF within the prism. Point correspondences between the CT and MR images identified within the prism could be used as additional boundary constraints to enforce the model deformation. The FEM deformation field is smooth in the interior of the prism, and equal to the Velocity displacements at the boundary of the prism. To evaluate the Velocity and FEM registration results, three criteria were used: prostate volume conservation and center consistence under contour mapping, and unbalanced energy of their deformation maps. Results: With the DVFs generated by the Velocity and FEM simulations, the prostate contours were warped from MRI to CT images. With the Velocity DVFs, the prostate volumes changed 10.2% on average, in contrast to 1.8% induced by the FEM DVFs. The average of the center deviations was 0.36 and 0.27 cm, and the unbalance energy was 2.65 and 0.38 mJ/cc3 for the Velocity and FEM registrations, respectively. Conclusion: The adaptive FEM method developed can be used to reduce the error of the MIbased registration algorithm implemented in Velocity in the prostate region, and consequently may help improve the quality of MRI-guided radiation therapy.

60 APPLIED LIFE SCIENCES↗

Analytical platform evaluation for quantification of ERG in prostate cancer using protein and mRNA detection methods

Background: The established methods for detecting prostate cancer (CaP) are based on tests using PSA (blood), PCA3 (urine), and AMACR (tissue) as biomarkers in patient samples. The demonstration of ERG oncoprotein overexpression due to gene fusion in CaP has thus provided ERG as an additional biomarker. Based on this, we hypothesized that ERG protein quantification methods can be of use in the diagnosis of prostate cancer. Methods: Therefore, an antibody-free assay for ERG3 protein detection was developed based on PRISM (high-pressure high-resolution separations with intelligent selection and multiplexing)-SRM (selected reaction monitoring) mass spectrometry. We utilized TMPRSS2-ERG positive VCaP and TMPRSS2-ERG negative LNCaP cells to simulate three different sample types (cells, tissue, and post-DRE urine sediment). Results: Recombinant ERG3 protein spiked into LNCaP cell lysates could be detected at levels as low as 20 pg by PRISM-SRM analysis. The sensitivity of the PRISM-SRM assay was around approximately 10,000 VCaP cells in a mixed cell population model of VCaP and LNCaP cells. Interestingly, ERG protein could be detected in as few as 600 VCaP cells spiked into female urine. The sensitivity of the in-house enzyme-linked immunosorbent assay (ELISA) was similar to the PRISM-SRM assay, with detection of 30 pg of purified recombinant ERG3 protein and 10,000 VCaP cells. On the other hand, qRT-PCR exhibited a higher sensitivity, as TMPRSS2-ERG transcripts were detected in as few as 100 VCaP cells, in comparison to NanoString methodologies which detected ERG from 10,000 cells. Conclusions: Based on this data, we propose that the detection of both ERG transcriptional products with RNA-based assays, as well as protein products of ERG using PRISM-SRM assays, may be of clinical value in developing diagnostics and prognostics assays for prostate cancer given their sensitivity, specificity, and reproducibility.

59 BASIC BIOLOGICAL SCIENCES↗

Development of an Enhanced Radiation Physics Toolset for Modeling Spectral and Imaging Signatures in the Warm Dense Matter Experiments

Radiative and atomic processes in plasmas play a critical role in a wide variety of high energy density laboratory plasma (HEDLP) experiments. The emission, absorption, and transport of radiation can strongly affect the overall energetics and evolution of such plasmas. In addition, radiation-based diagnostics – including imaging, spectroscopy, and absolute flux measurements – are widely used to determine key features of HEDLPs. To advance our understanding of HEDLP science, it is vital to have high-fidelity computational physics tools that have well-tested radiation physics modeling, and that are readily accessible to researchers in the HEDLP community. Simulations play an extremely important role for planning and designing the experiments, as well as for post-experiment data analysis. Prism Computational Sciences develops software that is used by National Laboratories and universities (including five members of LaserNetUS network). Prominent examples of such research efforts include z-pinch and short-pulse laser experiments designed to study the basic physics of photoionized plasmas and photoionization fronts, as well as their application to astrophysical plasmas. The main effort was dedicated to the development of non-equilibrium equation-of-state (EOS) models within the HELIOS-CR code, a hydrodynamics code with inline collisional-radiative atomic kinetics. Gas cell experiments on Z and Omega demonstrated the importance of non-equilibrium effects on atomic kinetics in photoionized plasmas. Recent proof-of-principle experiments on Omega EP confirmed the advantages of using a short-pulse laser to create an intense radiation drive, leading to additional experiments being proposed. Photoionization front experiments at LLE also emphasizes the importance of radiation and atomic physics. In both studies, HELIOS-CR simulations played a crucial role in computing non-equilibrium opacities and ionization distributions. A newly developed non-LTE EOS model will help addressing possible non-equilibrium effects, on for example specific heat, and their influence in plasma evolution. Prism also implemented support for open-source atomic data generated by the Flexible Atomic Code. This allows researchers to generate custom atomic tables and use them within the complex framework of simulation tools developed by Prism. The ability to use open-source atomic data would be extremely valuable for hydrodynamics and spectroscopic simulations that include high-Z materials, e.g., picosecond x-ray pulse generation experiments. Support for new atomic structures was fully implemented, and the data can be used by all simulation tools developed at Prism: radiation-hydrodynamics, imaging and spectroscopy, EOS and opacity. The development resulted in a significant fidelity enhancement to the simulations tools developed by Prism that are currently used in other cutting-edge experiments including: opacity measurement experiments performed to both understand the basic radiative and atomic properties of plasmas as well as provide data for more accurately modeling the internal structure of the Sun and other stars, high-intensity short-pulse laser experiments performed to develop short-wavelength light sources for use as backlighters and to investigate fast ignition concepts for inertial fusion energy; capsule implosion experiments designed to develop inertial fusion as an energy source, etc.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Correction of Single Frequency Altimeter Measurements for Ionosphere Delay

This study is a preliminary analysis of the accuracy of various ionosphere models to correct single frequency altimeter height measurements for Ionospheric path delay. In particular, research focused on adjusting empirical and parameterized ionosphere models in the parameterized real-time ionospheric specification model (PRISM) 1.2 using total electron content (TEC) data from the global positioning system (GPS). The types of GPS data used to adjust PRISM included GPS line-of-sight (LOS) TEC data mapped to the vertical, and a grid of GPS derived TEC data in a sun-fixed longitude frame. The adjusted PRISM TEC values, as well as predictions by IRI-90, a climatotogical model, were compared to TOPEX/Poseidon (T/P) TEC measurements from the dual-frequency altimeter for a number of T/P tracks. When adjusted with GPS LOS data, the PRISM empirical model predicted TEC over 24 1 h data sets for a given local time to with in a global error of 8.60 TECU rms during a midnight centered ionosphere and 9.74 TECU rms during a noon centered ionosphere. Using GPS derived sun-fixed TEC data, the PRISM parameterized model predicted TEC within an error of 8.47 TECU rms centered at midnight and 12.83 TECU rms centered at noon. From these best results, it is clear that the proposed requirement of 3-4 TECU global rms for TOPEX/Poseidon Follow-On will be very difficult to meet, even with a substantial increase in the number of GPS ground stations, with any realizable combination of the aforementioned models or data assimilation schemes.

Schreiner, William S.↗

Lidar Remote Sensing System

A lidar remote sensing system wherein a laser signal is transmitted along an optical path through a telescope having a primary and secondary mirrors and a rotating prism at the telescope output. When the reflected signal from the target is received it is passed back through the system to a detector, where it is heterodyned with a signal from a local oscillator to detect Doppler frequency shifts in the returned signal. Since the prism is rotating, the prism will be at one position when the signal is transmitted and at another when the returned signal is received. This causes the reflected signal to be off the optical path, reducing the power of the returned signal. To correct this problem a de-rotator or prism is mounted for rotation, in synchronism with the rotating prism. about the optical path in a position to intersect the returned beam and refract it back onto the optical path to reduce the power loss in the returned signal.

Michael J Kavaya↗

Efficient Coupler for a Bessel Beam Dispersive Element

A document discusses overcoming efficient optical coupling to high orbital momentum modes by slightly bending the taper dispersive element. This little shape distortion is not enough to scramble the modes, but it allows the use of regular, free-beam prism coupling, fiber coupling, or planar fiber on-chip coupling with, ultimately, 100 percent efficiency. The Bessel-beam waveguide is bent near the contact with the coupler, or a curved coupler is used. In this case, every Bessel-beam mode can be successfully coupled to a collimated Gaussian beam. Recently developed Bessel-beam waveguides allow long optical delay and very high dispersion. Delay values may vary from nanoseconds to microseconds, and dispersion promises to be at 100 s/nm. Optical setup consisted of a red laser, an anamorphic prism pair, two prism couplers, and a bent, single-mode fiber attached to prisms. The coupling rate increased substantially and corresponded to the value determined by the anamorphic prism pair.

Savchenkov, Anatoliy↗

Monolithic, High-Speed Fiber-Optic Switching Array for Lidar

Current fiber switch technologies use mechanical means to redirect light beams, resulting in slow switch time, as well as poor reliability due to moving parts wearing out quickly at high speeds. A non-mechanical ability to switch laser output into one of multiple fibers within a fiber array can provide significant power, weight, and costs savings to an all-fiber system. This invention uses an array of crystals that act as miniature prisms to redirect light as an electric voltage changes the prism s properties. At the heart of the electro-optic fiber-optic switch is an electro- optic crystal patterned with tiny prisms that can deflect the beam from the input fiber into any one of the receiving fibers arranged in a linear array when a voltage is applied across the crystal. Prism boundaries are defined by a net dipole moment in the crystal lattice that has been poled opposite to the surrounding lattice fabricated using patterned, removable microelectrodes. When a voltage is applied across the crystal, the resulting electric field changes the index of refraction within the prism boundaries relative to the surrounding substrate, causing light to deflect slightly according to Snell s Law. There are several materials that can host the necessary monolithic poled pattern (including, but not limited to, SLT, KTP, LiNbO3, and Mg:LiNbO3). Be cause this is a solid-state system without moving parts, it is very fast, and does not wear down easily. This invention is applicable to all fiber networks, as well as industries that use such networks. The unit comes in a compact package, can handle both low and high voltages, and has a high reliability (100,000 hours without maintenance).

Suckow, Will↗

Temperature-Dependent Refractive Index Measurements of L-BBH2 Glass for the Subaru CHARIS Integral Field Spectrograph

Using the Cryogenic High Accuracy Refraction Measuring System (CHARMS) at NASA's Goddard Space Flight Center, we have made the first cryogenic measurements of absolute refractive index for Ohara L-BBH2 glass to enable the design of a prism for the Coronagraphic High Angular Resolution Imaging Spectrograph (CHARIS) at the Subaru telescope. L-BBH2 is employed in CHARIS's prism design for improving the spectrograph's dispersion uniformity. Index measurements were made at temperatures from 110 to 305 K at wavelengths from 0.46 to 3.16 micron. We report absolute refractive index (n), dispersion (dn/d(lambda), and thermo-optic coefficient (dn/dT) for this material along with estimated single measurement uncertainties as a function of wavelength and temperature. We provide temperature-dependent Sellmeier coefficients based on our data to allow accurate interpolation of index to other wavelengths and temperatures within applicable ranges. This paper also speaks of the challenges in measuring index for a material which is not available in sufficient thickness to fabricate a typical prism for measurement in CHARMS, the tailoring of the index prism design that allowed these index measurements to be made, and the remarkable results obtained from that prism for this practical infrared material.

geometrical optics↗

Observations of Phobos and Deimos with SpeX at NASA Infrared Telescope Facility

We measured near-infrared (NIR) reflectance spectra of Phobos and Deimos, using the prism (0.7–2.52 μm) and long-wavelength cross dispersed (LXD: 1.9–4.2 μm) modes of NASA Infrared Telescope Facility (IRTF)’s SpeX instrument. The goal of this study is to investigate the surface composition of Phobos and Deimos and search for any mineralogical absorption signatures that may be present on their surfaces, especially in the LXD spectral range. Prism spectra of Phobos showed significant slope variation at shorter wavelengths (λ <1.3 μm), which indicates surface heterogeneity possibly due to regolith’s composition and grain size, and/or space weathering. Deimos’ prism spectra were found to be consistent with the more red-sloped prism spectra of Phobos. The measured LXD spectra of Deimos revealed evidence of hydration with 3-μm band depths at 2.90 μm of 4–5%. The 3-μm band in Deimos could be attributed to exogenic sources such as solar wind implantation or OH-bearingimpactors, or to an endogenic source and the presence of carbonaceous material on its surface. Phobos’ andDeimos’ prism and LXD spectra, however, show no indications for absorption signatures of mafic silicates (i.e.,pyroxene, olivine), organics nor carbonates.

D Takir↗

Direct view zoom scope with single focal plane and adaptable reticle

A direct view telescopic sight includes objective lens, eyepiece, and prism erector assemblies. The objective lens assembly is mounted to receive light of an image from an object direction and direct the light along an optical path. The eyepiece assembly is mounted to receive the light along the optical path and to emit the light of the image along an eye-ward direction. The prism erector assembly is positioned between the objective lens and eyepiece assemblies and includes first and second prism elements through which the optical path passes. The first and second prism elements invert the image. A reticle element is disposed on or adjacent to a surface of one of the first or second prism elements to combine a reticle on the image. The image is brought into focus at only a single focal plane between the objective lens and eyepiece assemblies at a given time.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

IR Spectrometer Using 90-degree Off-axis Parabolic Mirrors

A gated spectrometer has been designed for real-time, pulsed infrared (IR) studies at the National Synchrotron Light ource at the Brookhaven National Laboratory. A pair of 90-degree, off-axis parabolic mirrors are used to relay the light from an entrance slit to an output IR recording camera. With an initial wavelength range of 1500–4500 nm required, gratings could not be used in the spectrometer because grating orders would overlap. A magnesium oxide prism, placed between these parabolic mirrors, serves as the dispersion element. The spectrometer is doubly telecentric. With proper choice of the air spacing between the prism and the second parabolic mirror, any spectral region of interest within the InSb camera array’s sensitivity region can be recorded. The wavelengths leaving the second parabolic mirror are collimated, thereby relaxing the camera positioning tolerance. To set up the instrument, two different wavelength (visible) lasers are introduced at the entrance slit and made collinear with the optical axis via flip mirrors. After dispersion by the prism, these two laser beams are directed to tick marks located on the outside housing of the gated IR camera. This provides first-order wavelength calibration for the instrument. Light that is reflected off the front prism face is coupled into a high-speed detector to verify steady radiance during the gated spectral imaging. Alignment features include tick marks on the prism and parabolic mirrors. This instrument was designed to complement singlepoint pyrometry, which provides continuous time histories of a small collection of spots from shock-heated targets.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Technetium Dichloride: A New Binary Halide Containing Metal-Metal Multiple Bonds

Technetium dichloride has been discovered. It was synthesized from the elements and characterized by several physical techniques, including single crystal X-ray diffraction. In the solid state, technetium dichloride exhibits a new structure type consisting of infinite chains of face sharing [Tc{sub 2}Cl{sub 8}] rectangular prisms that are packed in a commensurate supercell. The metal-metal separation in the prisms is 2.127(2) {angstrom}, a distance consistent with the presence of a Tc {triple_bond} Tc triple bond that is also supported by electronic structure calculations.

36 MATERIALS SCIENCE↗

Advanced Dark Energy Physics Telescope (ADEPT)

In 2006, we proposed to NASA a detailed concept study of ADEPT (the Advanced Dark Energy Physics Telescope), a potential space mission to reliably measure the time-evolution of dark energy by conducting the largest effective volume survey of the universe ever done. A peer-review panel of scientific, management, and technical experts reported back the highest possible 'excellent' rating for ADEPT. We have since made substantial advances in the scientific and technical maturity of the mission design. With this Department of Energy (DOE) award we were granted supplemental funding to support specific extended research items that were not included in the NASA proposal, many of which were intended to broadly advance future dark energy research, as laid out by the Dark Energy Task Force (DETF). The proposed work had three targets: (1) the adaptation of large-format infrared arrays to a 2 micron cut-off; (2) analytical research to improve the understanding of the dark energy figure-of- merit; and (3) extended studies of baryon acoustic oscillation systematic uncertainties. Since the actual award was only for {approx}10% of the proposed amount item (1) was dropped and item (2) work was severely restricted, consistent with the referee reviews of the proposal, although there was considerable contradictions between reviewer comments and several comments that displayed a lack of familiarity with the research. None the less, item (3) was the focus of the work. To characterize the nature of the dark energy, ADEPT is designed to observe baryon acoustic oscillations (BAO) in a large galaxy redshift survey and to obtain substantial numbers of high-redshift Type Ia supernovae (SNe Ia). The 2003 Wilkinson Microwave Anisotropy Probe (WMAP) made a precise determination of the BAO 'standard ruler' scale, as it was imprinted on the cosmic microwave background (CMB) at z {approx} 1090. The standard ruler was also imprinted on the pattern of galaxies, and was first detected in 2005 in Sloan Digital Sky Survey (SDSS) data. A measurement of the BAO standard ruler as a function of time (or redshift) would provide powerful and reliable observational data to shed light on dark energy. In particular, the BAO data provide the angular diameter distance to each redshift, and directly give the expansion rate, H(z), at each redshift. The SNe measurements provide luminosity distances. A space mission is required to obtain the three-dimensional position of enormous numbers of galaxies at high redshift. As recognized by the Dark Energy Task Force, BAO systematic errors are naturally low. The following are the key findings: (1) The BAO method is robust. (2) Separation of the spectral and imaging detection focal planes vastly improves spectral identifications. (3) Prisms instead of grisms provide higher throughput and cleaner spectra. Prisms are clearly superior. (4) Lower prism dispersions improve signal-to-noise but high prism dispersions improve systematic. To ensure that the experiment is not systematic limited, a high dispersion should be used. (5) Counter-dispersion of the spectra reduces systematic errors on the redshift determination and assists in the reduction of confusion. (6) Small rolls are very effective for the reduction of confusion. (7) Interlopers can be recognized by a variety of methods, which combine to produce a sufficiently 'clean' survey data set so as not to limit the dark energy results. (8) A space mission can measure the BAO signature to the cosmic variance limit, limited only by statistics and not by systematic. (9) Density field reconstruction allows for significant BAO accuracy improvements, well beyond that assumed by the Dark Energy Task Force. (10) The BAO method is statistically powerful. It is more powerful than previously estimated, and far more powerful than high redshift Type 1a supernovae, for which the ultimate distance accuracy is limited by flux calibration accuracy. (11) The BAO technique is far simpler than the weak lensing technique and likely to produce more robust dark energy solutions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗