Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particle Deformation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Mechanics of Granular Materials (MGM)

The constitutive behavior of uncemented granular materials such as strength, stiffness, and localization of deformations are to a large extend derived from interparticle friction transmitted between solid particles and particle groups. Interparticle forces are highly dependent on gravitational body forces. At very low effective confining pressures, the true nature of the Mohr envelope, which defines the Mohr-Coulomb failure criterion for soils, as well as the relative contribution of each of non-frictional components to soil's shear strength cannot be evaluated in terrestrial laboratories. Because of the impossibility of eliminating gravitational body forces on earth, the weight of soil grains develops interparticle compressive stresses which mask true soil constitutive behavior even in the smallest samples of models. Therefore the microgravity environment induced by near-earth orbits of spacecraft provides unique experimental opportunities for testing theories related to the mechanical behavior of terrestrial granular materials. Such materials may include cohesionless soils, industrial powders, crushed coal, etc. This paper will describe the microgravity experiment, 'Mechanics of Granular Materials (MGM)', scheduled to be flown on Space Shuttle-MIR missions. The paper will describe the experiment's hardware, instrumentation, specimen preparation procedures, testing procedures in flight, as well as a brief summary of the post-mission analysis. It is expected that the experimental results will significantly improve the understanding of the behavior of granular materials under very low effective stress levels.

Alshibli, Khalid A.↗

Simulation System for Training in Laparoscopic Surgery

A computer-based simulation system creates a visual and haptic virtual environment for training a medical practitioner in laparoscopic surgery. Heretofore, it has been common practice to perform training in partial laparoscopic surgical procedures by use of a laparoscopic training box that encloses a pair of laparoscopic tools, objects to be manipulated by the tools, and an endoscopic video camera. However, the surgical procedures simulated by use of a training box are usually poor imitations of the actual ones. The present computer-based system improves training by presenting a more realistic simulated environment to the trainee. The system includes a computer monitor that displays a real-time image of the affected interior region of the patient, showing laparoscopic instruments interacting with organs and tissues, as would be viewed by use of an endoscopic video camera and displayed to a surgeon during a laparoscopic operation. The system also includes laparoscopic tools that the trainee manipulates while observing the image on the computer monitor (see figure). The instrumentation on the tools consists of (1) position and orientation sensors that provide input data for the simulation and (2) actuators that provide force feedback to simulate the contact forces between the tools and tissues. The simulation software includes components that model the geometries of surgical tools, components that model the geometries and physical behaviors of soft tissues, and components that detect collisions between them. Using the measured positions and orientations of the tools, the software detects whether they are in contact with tissues. In the event of contact, the deformations of the tissues and contact forces are computed by use of the geometric and physical models. The image on the computer screen shows tissues deformed accordingly, while the actuators apply the corresponding forces to the distal ends of the tools. For the purpose of demonstration, the system has been set up to simulate the insertion of a flexible catheter in a bile duct. [As thus configured, the system can also be used to simulate other endoscopic procedures (e.g., bronchoscopy and colonoscopy) that include the insertion of flexible tubes into flexible ducts.] A hybrid approach has been followed in developing the software for real-time simulation of the visual and haptic interactions (1) between forceps and the catheter, (2) between the forceps and the duct, and (3) between the catheter and the duct. The deformations of the duct are simulated by finite-element and modalanalysis procedures, using only the most significant vibration modes of the duct for computing deformations and interaction forces. The catheter is modeled as a set of virtual particles uniformly distributed along the center line of the catheter and connected to each other via linear and torsional springs and damping elements. The interactions between the forceps and the duct as well as the catheter are simulated by use of a ray-based haptic-interaction- simulating technique in which the forceps are modeled as connected line segments.

Basdogan, Cagatay↗

Single-Particle Studies Reveal a Nanoscale Mechanism for Elastic, Bright, and Repeatable ZnS:Mn Mechanoluminescence in a Low-Pressure Regime

Mechanoluminescent materials, which emit light in response to elastic deformation, are demanded for use as in situ stress sensors. ZnS doped with Mn is known to exhibit one of the lowest reported thresholds for appearance of mechanoluminescence, with repeatable light emission under contact pressure <10 MPa. Here, the physical basis for such behavior remains as yet unclear. Here, reliable microscopic detection of mechanoluminescence of single ZnS:Mn microparticles, in combination with nanoscale structural characterization, provides evidence that the mechanoluminescent properties of these particles result from interplay between a non-centrosymmetric crystal lattice and its defects, viz., dislocations and stacking faults. Statistical analysis of the distributions of mechanoluminescence energy release trajectories reveals two distinct mechanisms of excitation: one attributable to a piezo-phototronic effect and the other due to dislocation motion. At pressures below 8.1 MPa, both mechanisms contribute to mechanoluminescent output, with a dominant contribution from the piezo-phototronic mechanism. In contrast, above 8.1 MPa, dislocation motion is the primary excitation source. For the piezo-phototronic mechanism, we propose a specific model that accounts for elastic ZnS:Mn mechanoluminescence under very low pressure. The charged interfaces in stacking faults lead to the presence of filled traps, which otherwise would be empty in the absence of the built-in electric field. Upon application of external stress, local enhancement of the piezoelectric field at the stacking faults’ interfaces facilitates release of the trapped carriers and subsequent luminescence. This field enhancement explains how <10 MPa pressure produces thousands of photons.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermal energy evolution and mechanical deformation of monocrystalline yttria-stabilized zirconia nanoparticles in aerosol deposition processes

Aerosol deposition (AD) is a coating process wherein aerosol particles are impacted on a target substrate. There are fundamental differences between the AD process (cold impact), where particle translational kinetic energy is high and thermal energy is low, and thermal spray deposition (thermal impact), where translational energy is lower but thermal energy is high. To better compare cold and thermal impact effects on particles, we carried out molecular dynamics simulations using yttria-stabilized zirconia (YSZ) nanoparticles on YSZ substrates as a model system. We performed cold impact simulations at 300 K with variable impact velocity in the 500 ms –1 –1500 ms –1 range to understand how increasing translational kinetic energy affects thermal energy and mechanical evolution. We then performed thermal impact simulations at variable temperature and impact velocity, but where the total kinetic energy of the nanoparticle was equivalent to that of a 300 K, 1000 impact. In cold impact, the temperature increases in YSZ nanoparticles at a rate of 10 13 – 10 14 K s –1 , and large temperature gradients result. Conversely, in thermal impact, nanoparticle temperatures remain uniform. Furthermore, the temperature gradients during cold impact coincide with plastic deformation in nanoparticles, while with larger thermal energies, plastic deformation is reduced.

42 ENGINEERING↗

Measurement of the azimuthal anisotropy of charged particles in sNN=5.36TeV O16+O16 and Ne20+Ne20 collisions with the ATLAS detector

This paper presents the first measurements of the azimuthal anisotropy coefficients , which quantify the -order Fourier modulation of charged-particle azimuthal distributions, for in and collisions recorded with the ATLAS detector at the CERN Large Hadron Collider in 2025. The coefficients are measured as a function of transverse momentum ( ), collision centrality, and event multiplicity. They are extracted using two complementary methods: two-particle correlations with a template-fit subtraction of short-range nonflow contributions, and four-particle subevent cumulants, which intrinsically suppress nonflow effects and provide sensitivity to flow fluctuations. The results show a clear hierarchy and a nonmonotonic dependence on , reaching a maximum around , consistent with trends observed in heavy-ion collisions. Detailed comparisons between the two collision systems reveal an enhanced in central collisions, consistent with theory expectations based on the predicted prolate deformation of neon nuclei, in contrast to the slightly tetrahedral structure predicted for oxygen. The four-particle cumulant results highlight strong event-by-event fluctuations and provide the greatest sensitivity to nuclear shape effects. These measurements can place new constraints on the initial geometry and the hydrodynamic response in light-ion collisions, offering valuable input for models of nuclear structure.

Aad, G↗

Elevated temperature slow plastic deformation of NiAl-TiB2 particulate composites at 1200 and 1300 K

Elevated temperature compression testing has been conducted in air at 1200 and 1300 K with strain rates varying from about 10 to the -4th to about 10 to the -7th/sec on NiAl-TiB2 particulate composites. These materials, which consisted of a B2 crystal structure intermetallic Ni-50 at. pct Al matrix and from 0 to 30 vol pct of approximately 1- micron diameter TiB2 particles, were fabricated by XD synthesis and hot pressed to full density. Flow strength of the composites increased with volume fraction of the strengthening phase with NiAl-30TiB2 being approximately three times stronger than NiAl. Comparison of the light optical and TEM microstructures of as-received and tested samples revealed that reactions did not occur between the two phases, and NiAl-TiB2 interfaces were not cracked during deformation. Additional TEM indicated that the particles stabilize a vastly different microstructure in the NiAl matrix of the composites than that formed in unreinforced NiAl.

Whittenberger, J. Daniel↗

Temperature-Dependent Magnetic Properties of Magnetorheological Elastomers

We report on an investigation of the temperature-dependent magnetic properties of magnetorheological elastomers (MREs). These are a class of composites that consist of magnetically permeable particles dispersed in a nonmagnetic polymeric matrix. Under the application of an external magnetic field, a large deformation occurs altering the mechanical properties of these materials. Due to their magnetoelastic coupling response, these materials are finding an increasing interest among the scientific community. These polymer-based composites’ performance depends on many factors, which temperature is one of the biggest influencing factors requiring further investigation. In this work, the magnetic properties of isotropic and anisotropic polyurethane-based MRE with different iron (Fe) particle loading fractions (50, 60, 70, and 80% by weight) were investigated under different temperatures. From the analysis, the magnetization curves of these materials are observed to overlap for the different measured temperature values. The variation of various magnetic properties including saturation magnetization and differential susceptibility with temperature was also determined. Furthermore, the results show ~ 2.5% decrement in the saturation magnetization for each of the loading fractions, between the lowest (300K) and the highest (400K) measured temperature. On the other hand, the initial differential susceptibility exhibits different trends with increasing temperature. Generally, the magnetization response of these materials is seen to be only slightly sensitive to temperature changes. Additionally, the magnetization response is observed to be highly dependent on particle loading fractions and particle orientation within the elastomer.

36 MATERIALS SCIENCE↗

Microsecond Isomer at the N = 20 Island of Shape Inversion Observed at FRIB

Excited-state spectroscopy from the first experiment at the Facility for Rare Isotope Beams (FRIB) is reported. A 24(2)-μs isomer was observed with the FRIB Decay Station initiator (FDSi) through a cascade of 224- and 401-keV γ rays in coincidence with 32 Na nuclei. This is the only known microsecond isomer (1 μs ≤T 1/2 <1 ms) in the region. This nucleus is at the heart of the N=20 island of shape inversion and is at the crossroads of the spherical shell-model, deformed shell-model, and ab initio theories. It can be represented as the coupling of a proton hole and neutron particle to 32 Mg, 32 Mg+π -1 +ν +1 . This odd-odd coupling and isomer formation provides a sensitive measure of the underlying shape degrees of freedom of 32 Mg, where the onset of spherical-to-deformed shape inversion begins with a low-lying deformed 2 + state at 885 keV and a low-lying shape-coexisting 0$^+_2$ state at 1058 keV. Here, we suggest two possible explanations for the 625-keV isomer in 32 Na: a 6 - spherical shape isomer that decays by E2 or a 0 + deformed spin isomer that decays by M2. The present results and calculations are most consistent with the latter, indicating that the low-lying states are dominated by deformation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Wear Mechanism Analysis of a New Rotary Shear Biomass Comminution System

A new biomass comminution system, Crumbler rotary shear, was developed to process fuel-grade biomass. The rotary shear is more efficient than the traditional hammer mill in comminuting high-moisture biomass and producing more uniform particles with minimal fines. However, the milling unit experiences significant wear in processing dirty woodchips. This study investigated the wear mechanisms of the rotary shear system based on analysis of the minerals carried by woodchips and characterization of actual worn components. Abrasive wear was found to be the dominant effect, and localized adhesive wear (material transfer), microfracture (chipping), and plastic deformation were additional effects. Connections have been made between the wear progression of key cutting components and the particle size change of biomass extrinsic minerals. On the basis of the wear mechanism understanding, mitigations based on advanced tool materials and optimized tool geometric designs are being developed for improving the tool life and cutting efficiency.

09 BIOMASS FUELS↗

Operando Topography and Mechanical Property Mapping of CO 2 Reduction Gas-Diffusion Electrodes Operating at High Current Densities

Electrochemical atomic force microscopy (EC-AFM) enables measurement of electrode topography and mechanical properties during electrochemical reactions. However, for aqueous-based reactions that make gas products, such as CO 2 reduction and water splitting into CO/H 2 , current densities below 1 mA cm −2 have been necessary to prevent formation of bubbles at the electrode; such bubbles can stick to the AFM probe and prevent further AFM imaging. Here, we demonstrate a novel cell design with a gas-diffusion electrode (GDE) to exhaust the gas products, thereby enabling high current density EC-AFM measurements at 1, 10, and 100 mA cm −2 that are not disturbed by bubble formation at the electrode surface. These experiments revealed a stable morphological structure of Cu catalysts deposited on GDEs during high current density operation. Systematic spatially resolved maps of deformation and adhesion showed no signs of a gas-liquid interface between catalyst particles of the GDE.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Deformation characteristics and time-dependent notch sensitivity of Udimet 700 at intermediate temperatures

Time dependent notch sensitivity was observed in Udimet 700 sheet, bar, and investment castings between 1000 and 1400 F (538 -760 C), but not at 1600 F (871 C). As was the case for modified Waspaloy, Waspaloy and Inconel 718, it occurred in notched specimens loaded below the yield strength when the creep deformation was localized. For each alloy and notched specimen geometry, a stress-average particle size zone can be defined that characterizes the notch sensitive behavior.

Wilson, D. J.↗

A study of fatigue damage mechanisms in Waspaloy from 25 to 800 C

The objective of the study was to examine the effect of various microstructures on the fatigue and damage accumulation behavior of Waspaloy, a nickel-base alloy commonly used in aircraft engines. Shearing was the dominant deformation mode in specimens with coarse grains and small (50-80 A) gamma prime particles, whereas Orowan looping was dominant in fine-grained specimens with large (about 900 A) gamma prime particles. At temperatures up to 500 C, cracks initiated transgranularly, while at 800 C the failure process was intergranular for both coarse-grained and fine-grained specimens. At temperatures above 500 C, a significant decrease in the fatigue life was observed for both coarse-grained and fine-grained material.

Lerch, B. A.↗

Structural, Criticality, and Radiation Dose Calculations to Support SNF Loading into a DOE Standard Canister

The DOE Standard Canister Demonstration Project includes the development of an internal support structure (ISS) for the 4.6-m-long and 45.7-cm-diameter canister. This study presents structural evaluations, criticality safety assessments, and dose rate calculations conducted within the scope of the ISS design process to support smooth canister loading operations and to ensure safe storage, transportation, and disposal of Peach Bottom 1 Core II (PB2) and Fort St. Vrain (FSV) SNF, currently stored at INL’s CPP-603 facility. The ISS includes a 316L stainless-steel basket that holds 12 PB2 SNF rods. The PB2 basket rests on top of six individual, 78.7-cm-long, 316L stainless-steel columns that are equally spaced and welded to the inner canister wall at the lower end of the shell. These columns represent the FSV basket and can hold one FSV SNF element. An A92014 T6 aluminum spacer disc is bolted to the bottom plate of the PB2 basket to vertically restrain the FSV SNF element after the PB2 basket is placed inside the canister above the FSV basket. The structural evaluations of the ISS followed applicable ASME BPVC.III.3 guidelines and included finite element (FE) analyses of the PB2 basket structure; analyses of welds and bolds; buckling analyses of selected components, and acceptability assessments of the expected basket deformations under loading operations. The criticality safety assessments used the Monte Carlo N-Particle (MCNP) software architecture Version 6.2, including ENDF/B-V continuous-energy cross-section libraries, considering intact SNF in a single storage overpack or two multistorage overpack configurations and intact or failed SNF configured for disposal. The dose rate computations are based on source terms taken from the DOE Spent Fuel Database. The isotopic composition was decay corrected for the year 2022 using the ORIGEN module in the SCALE suite. A 19-group photon spectrum and a 27-group neutron-source spectrum were generated and used in MCNP to calculate estimated dose-equivalent rates, both on DOE Standard Canister contact and at a radial distance of 1 m from the canister surface. The results of this study indicate a structurally sound system that can uphold its criticality safety functions throughout its intended operational phases. Furthermore, this study provides confidence that sufficient radiological protection is technically achievable.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Structural, Criticality, and Radiation Dose Calculations to support SNF Loading into a DOE Standard Canister

The DOE Standard Canister Demonstration Project includes the development of an internal support structure (ISS) for the 4.6-m long and 45.7-cm diameter canister. This study presents structural evaluations, criticality safety assessments, and dose rate calculations conducted within the scope of the ISS design process to support smooth canister loading operations and to ensure safe storage, transportation, and disposal of Peach Bottom 1 Core II (PB2) and Fort St. Vrain (FSV) SNF, currently stored at the CPP-603 facility of the INL. The ISS includes a 316L stainless steel basket that holds twelve PB2 SNF rods. Further, six individual, 78.7-cm long, 316L stainless steel columns are equally spaced and welded to the inner canister wall at the lower end of the shell. These columns represent the FSV basket and can hold one FSV SNF element. An A92014 T6 aluminum spacer disc is bolted to the bottom plate of the PB2 basket to vertically restrain the FSV SNF element after the PB2 basket is placed inside the canister on top of the FSV basket. The structural evaluations of the ISS followed applicable ASME BPVC.III.3 guidelines and included finite element (FE) analyses of the PB2 basket structure; analyses of welds and bolds; buckling analyses of selected components, and acceptability assessments of the expected basket deformations under loading operations. The criticality safety assessments used the Monte Carlo N-Particle (MCNP) software architecture version 6.2 including ENDF/B-V continuous energy cross-section libraries, considering intact SNF in a single storage overpack or two multi-storage overpack configurations, and intact or failed SNF configured for disposal. The dose rate computations are based on source terms taken from the DOE Spent Fuel Database. The isotopic composition was decay corrected for the year 2022 using the ORIGEN module in the SCALE suite. A 19-group photon spectrum and 27-group neutron-source spectra were generated and used in MCNP to calculate estimated dose-equivalent rates, both on DOE Standard Canister contact and at a radial distance of from the canister surface. The results of this study indicate a structurally sound system that can uphold its criticality safety functions throughout its intended operational phases. Further, they increase confidence that sufficient radiological protection is technically achievable.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Measurement of the azimuthal anisotropy of charged particles in $\sqrt{s_{\mathrm{NN}}}=5.36$ TeV $^{16}$O$+^{16}$O and $^{20}$Ne$+^{20}$Ne collisions with the ATLAS detector

This paper presents the first measurements of the azimuthal anisotropy coefficients $v_{n}$, which quantify the $n^{\mathrm{th}}$-order Fourier modulation of charged-particle azimuthal distributions, for $n=2$-4 in $\sqrt{s_{\mathrm{NN}}}=5.36$ TeV $\mathrm{^{16}O}+\mathrm{^{16}O}$ and $\mathrm{^{20}Ne}+\mathrm{^{20}Ne}$ collisions recorded with the ATLAS detector at the Large Hadron Collider in 2025. The $v_{n}$ coefficients are measured as a function of transverse momentum ($p_{\mathrm{T}}$), collision centrality, and event multiplicity. They are extracted using two complementary methods: two-particle correlations with a template-fit subtraction of short-range non-flow contributions, and four-particle subevent cumulants, which intrinsically suppress non-flow effects and provide sensitivity to flow fluctuations. The results show a clear hierarchy $v_{2} > v_{3} > v_{4}$ and a non-monotonic dependence on $p_{\mathrm{T}}$, reaching a maximum around 2 GeV, consistent with trends observed in heavy-ion collisions. Detailed comparisons between the two collision systems reveal an enhanced $v_{2}$ in central $\mathrm{^{20}Ne}+\mathrm{^{20}Ne}$ collisions, consistent with theory expectations based on the predicted prolate deformation of neon nuclei, in contrast to the slightly tetrahedral structure predicted for oxygen. The four-particle cumulant results highlight strong event-by-event fluctuations and provide the greatest sensitivity to nuclear shape effects. These measurements can place new constraints on the initial geometry and the hydrodynamic response in light-ion collisions, offering valuable input for models of nuclear structure.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Equations of motion for a flexible spacecraft-lumped parameter idealization

The equations of motion for a flexible vehicle capable of arbitrary translational and rotational motions in inertial space accompanied by small elastic deformations are derived in an unabridged form. The vehicle is idealized as consisting of a single rigid body with an ensemble of mass particles interconnected by massless elastic structure. The internal elastic restoring forces are quantified in terms of a stiffness matrix. A transformation and truncation of elastic degrees of freedom is made in the interest of numerical integration efficiency. Deformation dependent terms are partitioned into a hierarchy of significance. The final set of motion equations are brought to a fully assembled first order form suitable for direct digital implementation. A FORTRAN program implementing the equations is given and its salient features described.

Storch, Joel↗

Modeling of Magnetic Properties of Magnetorheological Elastomers Using JA Hysteresis Model

Magnetorheological elastomers (MREs) are composite materials that consist of magnetically permeable particles in a nonmagnetic polymeric matrix. Under the influence of an external magnetic field, a reversible deformation change occurs in the mechanical properties of these materials. Due to their coupled magnetomechanical response, these materials have been found suitable for a range of applications including tunable vibration absorbers, sensors, and actuators. Notably, improvement of such devices are prerequisites to efficient energy conversion systems, hence the need to understand further the MRE technology. The Jiles-Atherton (JA) theory takes into consideration the magneto-coupling experienced by effective domains in a magnetic material. Algorithm based on the theory yields five model parameters; saturation magnetization (M s ), domain density (a), domain coupling (α), loss coefficient (k), and reversibility (c). Using JA theory, model parameters were calculated and linked to the physical attributes of Fe powder and isotropic MRE. The results show that the calculated Ms for the MRE is reasonably related to that of the Fe powder by a factor of the particle's volume fraction used in the MRE. Further, the calculated k, a, and α provided support for the reduced pinning factor, domain density, and increased domain coupling in the MRE due to the changes in the domain structure between the two materials. From the calculated JA parameters, finite-element modeling (FEM) of the MRE hysteresis loop was performed. The analysis showed that the modeled magnetic properties including coercivity, remanence, and coordinates of the hysteresis loop tip vary with geometric position.

42 ENGINEERING↗