Search NASA⌕ Search

SEARCH · Search NASA

Results for “Passive Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Modular High Temperature Gas-cooled Reactor: Accident Analysis

Types of Potential Accidents and Reactor Response Codes and Tools Experimental Validation Safety Analysis Approach Licensing Modernization Project Use of PRA in LMP, ASME/ANS, Non-LWR PRA Standard Methods for Incorporating Passive System Reliability into a PRA

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Insights from the WGRISK workshop on the PSA of advanced and new reactors

Probabilistic Safety Assessment /Probabilistic Risk Assessment for new and advanced reactors is recognized as an essential complement of the deterministic approaches to achieve improved safety and performances of new nuclear power plants, comparing to the operating plants. However, the development of PSA to these reactors is encountered to concurrent challenges, mainly due to the limited available design information, as well as due to potentially new initiating events, accident sequences and phenomena. The use of PSA in the decision making process is also challenging since the resulting PSA may not sufficiently reflect the future as-built, as-operated plant information. In order to address these aspects, the OECD/NEA/WGRISK initiated two coordinated tasks on 'PSA for Advanced Reactors' and 'PSA in the frame of Design and Commissioning of New NPPs'. In this context, a joint workshop was organized by OECD, during which related subjects were presented and discussed, including PSA for generation IV reactors, PSA for evolutionary reactors, PSA for small modular reactors, severe accidents and Level 2 PSA, Level 3 PSA and consequences analysis, digital I and C modeling, passive systems reliability, safety-security interface, as well as the results of the surveys performed in the frame of theses WGRISK tasks. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

MCNP Super Lattice Method for VHTR ORIGEN2.2 Nuclear Library Improvement Based on ENDF/B-VII

The advanced Very High Temperature gas-cooled Reactor (VHTR) achieves simplification of safety through reliance on innovative features and passive systems. One of the VHTRs innovative features is the reliance on ceramic-coated fuel particles to retain the fission products under extreme accident conditions. The effect of the random fuel kernel distribution in the fuel prismatic block creates a double-heterogeneous lattice, which needs to be addressed through the use of the newly developed prismatic super Kernel-by-Kernel Fuel (KbKF) lattice model method. Based on the new ENDF/B-VII nuclear cross section evaluated data, the developed KbKF super lattice model was then used with MCNP to calculate the material isotopes neutron reaction rates, such as, (n,?); (n,n’); (n,2n’); (n,f); (n,p); (n,?). Then, the MCNP-calculated results are rearranged to generate a set of new libraries “VHTRXS.lib,” for the ORIGEN2.2 isotopes depletion and build-up analysis code. The libraries contain one group cross section data for the structural light elements, actinides, and fission products that can be applied in the VHTR related fuel burnup and material transmutation analysis codes. The efficiency and ease of use of the MCNP method to generate and update the ORIGEN2.2 one-group spectrum weighed cross section library for VHTR was demonstrated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Mobile Pit verification system design based on passive special nuclear material verification in weapons storage facilities

A mobile 'drive by' passive radiation detection system to be applied in special nuclear materials (SNM) storage facilities for validation and compliance purposes has been designed through the use of computational modeling and new radiation detection methods. This project was the result of work over a 1 year period to create optimal design specifications to include creation of 3D models using both Monte Carlo and deterministic codes to characterize the gamma and neutron leakage out each surface of SNM-bearing canisters. Results were compared and agreement was demonstrated between both models. Container leakages were then used to determine the expected reaction rates using transport theory in the detectors when placed at varying distances from the can. A 'typical' background signature was incorporated to determine the minimum signatures versus the probability of detection to evaluate moving source protocols with collimation. This established the criteria for verification of source presence and time gating at a given vehicle speed. New methods for the passive detection of SNM were employed and shown to give reliable identification of age and material for highly enriched uranium (HEU) and weapons grade plutonium (WGPu). The finalized 'Mobile Pit Verification System' (MPVS) design demonstrated that a 'drive-by' detection system, collimated and operating at nominally 2 mph, is capable of rapidly verifying each and every weapon pit stored in regularly spaced, shelved storage containers, using completely passive gamma and neutron signatures for HEU and WGPu. This system is ready for real evaluation to demonstrate passive total material accountability in storage facilities. (authors)

97 MATHEMATICS AND COMPUTING↗

Performance Analyses of Passive Containment Cooling System for a Concrete Type Containment

The containment of nuclear power plants is the final barrier to keep the radioactive materials from uncontrolled release to the environment. To keep the containment integrity, pressure and temperature must be controlled by the spray system which relies on active components for PWRs with a concrete containment. To achieve a passive means to keep the containment integrity, therefore, cooling should be achieved by forming a natural circulation loop between internal cooling devices connected to an external heat sink. A system like this is often called Passive Containment Cooling System (PCCS). In the early phase of APR-1400 development, this concept was studied and VVER-1200 is also known to adopt the PCCS. The PCCS consists of a cooling device installed at the inside of the containment which is a tube-bank type heat exchanger where cooling occurs at the exterior of the tubes and a heat sink which is called Passive Containment Cooling Tank (PCCT) located at the outside of the containment on the top of the auxiliary building. In this paper, we introduce performance analysis results, utilizing the GOTHIC computer code. The PCCS performance analysis model was developed for APR-1400 which has a thermal power of 4000 MW and considers PCCS as an option to improve its safety characteristics. The PCCS which is considered in this paper is to cope with both Design Basis and Severe Accidents, considering SBO conditions. The pressure and temperature transients due to the Loss of Coolant Accident (LOCA) were analyzed with and without PCCS together with a normal case using the spray system. And, in particular, limitations of the PCCS in regard to mission time will be discussed. Through this study, it was found that the PCCS being considered as an option to improve the safety of APR-1400 can have almost same capability to control the containment pressure for LBLOCA as the containment spray system does. Although it would depends on the heat removal capacity of a given design such as the size of the heat transfer area, the PCCS could even replace the containment spray system. However, the PCCS may lose its capability after 24 hours as its temperature reaches that of the containment atmosphere. To extend the mission time of PCCS, either cooling or supplementary cold water needs to be provided to the external heat sink of PCCS. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Asymptotic Stability of Interconnected Passive Non-Linear Systems

This paper addresses the problem of stabilization of a class of internally passive non-linear time-invariant dynamic systems. A class of non-linear marginally strictly passive (MSP) systems is defined, which is less restrictive than input-strictly passive systems. It is shown that the interconnection of a non-linear passive system and a non-linear MSP system is globally asymptotically stable. The result generalizes and weakens the conditions of the passivity theorem, which requires one of the systems to be input-strictly passive. In the case of linear time-invariant systems, it is shown that the MSP property is equivalent to the marginally strictly positive real (MSPR) property, which is much simpler to check.

Isidori, A.↗

Challenges of Designing a Passive Thermal Control System for the Astrobotic Peregrine Lunar Lander

The Astrobotic Peregrine is a lunar lander currently undergoing design by Astrobotic Technology with help from NASA through the Lunar Cargo Transportation and Landing by Soft Touchdown (Lunar CATALYST) program. This paper will discuss the challenges of designing a passive thermal control system for the lander, and how the design has evolved from the initial passive concept. These challenges include drastically varying worst hot and worst cold case thermal environments, narrow temperature limits of critical components, limited available locations for spacecraft component mounting, and unexpected changes causing significant thermal impacts. The initial thermal control strategy was to cold bias the spacecraft by thermally coupling all spacecraft components to one mounting deck, which also doubled as a radiator, and using heaters to maintain each component’s temperature above its lower temperature limit when in the cold environments. As the design evolved, this strategy alone became inadequate. As heat dissipations increased and became more varying with the addition of components, the thermal design was changed and additional thermal control technologies added. Thermal control strategies incorporated into the design include dictating the lander orientation in demanding environments, defining locations for critical spacecraft components, limiting component operation when possible, and using technology to create variable thermal contacts. Additional design changes will occur as the design continues to evolve to optimize the most effective thermal control system. The thermal design of Peregrine is still in progress, with Critical Design Review (CDR) scheduled for December 2019.

Mauro, Stephanie↗

Performance evaluation of a hybrid-passive landfill leachate treatment system using multivariate statistical techniques

Highlights: • Performance of a hybrid passive landfill leachate treatment system was evaluated. • 33 Water chemistry parameters were sampled for 21 months and statistically analyzed. • Parameters were strongly linked and explained most (>40%) of the variation in data. • Alkalinity, ammonia, COD, heavy metals, and iron were criteria for performance. • Eight other parameters were key in modeling system dynamics and criteria. - Abstract: A pilot-scale hybrid-passive treatment system operated at the Merrick Landfill in North Bay, Ontario, Canada, treats municipal landfill leachate and provides for subsequent natural attenuation. Collected leachate is directed to a hybrid-passive treatment system, followed by controlled release to a natural attenuation zone before entering the nearby Little Sturgeon River. The study presents a comprehensive evaluation of the performance of the system using multivariate statistical techniques to determine the interactions between parameters, major pollutants in the leachate, and the biological and chemical processes occurring in the system. Five parameters (ammonia, alkalinity, chemical oxygen demand (COD), “heavy” metals of interest, with atomic weights above calcium, and iron) were set as criteria for the evaluation of system performance based on their toxicity to aquatic ecosystems and importance in treatment with respect to discharge regulations. System data for a full range of water quality parameters over a 21-month period were analyzed using principal components analysis (PCA), as well as principal components (PC) and partial least squares (PLS) regressions. PCA indicated a high degree of association for most parameters with the first PC, which explained a high percentage (>40%) of the variation in the data, suggesting strong statistical relationships among most of the parameters in the system. Regression analyses identified 8 parameters (set as independent variables) that were most frequently retained for modeling the five criteria parameters (set as dependent variables), on a statistically significant level: conductivity, dissolved oxygen (DO), nitrite (NO{sub 2}{sup −}), organic nitrogen (N), oxidation reduction potential (ORP), pH, sulfate and total volatile solids (TVS). The criteria parameters and the significant explanatory parameters were most important in modeling the dynamics of the passive treatment system during the study period. Such techniques and procedures were found to be highly valuable and could be applied to other sites to determine parameters of interest in similar naturalized engineered systems.

54 ENVIRONMENTAL SCIENCES↗

Measured Neutron Spectra and Dose Equivalents From a Mevion Single-Room, Passively Scattered Proton System Used for Craniospinal Irradiation

Purpose: To measure, in the setting of typical passively scattered proton craniospinal irradiation (CSI) treatment, the secondary neutron spectra, and use these spectra to calculate dose equivalents for both internal and external neutrons delivered via a Mevion single-room compact proton system. Methods and Materials: Secondary neutron spectra were measured using extended-range Bonner spheres for whole brain, upper spine, and lower spine proton fields. The detector used can discriminate neutrons over the entire range of the energy spectrum encountered in proton therapy. To separately assess internally and externally generated neutrons, each of the fields was delivered with and without a phantom. Average neutron energy, total neutron fluence, and ambient dose equivalent [H* (10)] were calculated for each spectrum. Neutron dose equivalents as a function of depth were estimated by applying published neutron depth–dose data to in-air H* (10) values. Results: For CSI fields, neutron spectra were similar, with a high-energy direct neutron peak, an evaporation peak, a thermal peak, and an intermediate continuum between the evaporation and thermal peaks. Neutrons in the evaporation peak made the largest contribution to dose equivalent. Internal neutrons had a very low to negligible contribution to dose equivalent compared with external neutrons, largely attributed to the measurement location being far outside the primary proton beam. Average energies ranged from 8.6 to 14.5 MeV, whereas fluences ranged from 6.91 × 10{sup 6} to 1.04 × 10{sup 7} n/cm{sup 2}/Gy, and H* (10) ranged from 2.27 to 3.92 mSv/Gy. Conclusions: For CSI treatments delivered with a Mevion single-gantry proton therapy system, we found measured neutron dose was consistent with dose equivalents reported for CSI with other proton beamlines.

07 ISOTOPE AND RADIATION SOURCES↗

International Space Station Passive Thermal Control System Analysis, Top Ten Lessons-Learned

The International Space Station (ISS) has been on-orbit for over 10 years, and there have been numerous technical challenges along the way from design to assembly to on-orbit anomalies and repairs. The Passive Thermal Control System (PTCS) management team has been a key player in successfully dealing with these challenges. The PTCS team performs thermal analysis in support of design and verification, launch and assembly constraints, integration, sustaining engineering, failure response, and model validation. This analysis is a significant body of work and provides a unique opportunity to compile a wealth of real world engineering and analysis knowledge and the corresponding lessons-learned. The analysis lessons encompass the full life cycle of flight hardware from design to on-orbit performance and sustaining engineering. These lessons can provide significant insight for new projects and programs. Key areas to be presented include thermal model fidelity, verification methods, analysis uncertainty, and operations support.

Iovine, John↗

International Space Station Passive Thermal Control System Top Ten Lessons-Learned

Final document not an Abstract attached. The International Space Station (ISS) has been on-orbit for nearly 20 years, and there have been numerous technical challenges along the way from design to assembly to on-orbit anomalies and repairs. The Passive Thermal Control System (PTCS) management team has been a key player in successfully dealing with these challenges. The PTCS team performs thermal analysis in support of design and verification, launch and assembly constraints, integration, sustaining engineering, failure response, and model validation. This analysis is a significant body of work and provides a unique opportunity to compile a wealth of real world engineering and analysis knowledge and the corresponding lessons-learned. The PTCS lessons encompass the full life cycle of flight hardware from design to on-orbit performance and sustaining engineering. These lessons can provide significant insight for new projects and programs. Key areas to be presented include thermal model fidelity, verification methods, analysis uncertainty, and operations support.

Iovine, John V.↗

International Space Station Passive Thermal Control System Top Ten Lessons-Learned

Final document not an Abstract attached. The International Space Station (ISS) has been on-orbit for nearly 20 years, and there have been numerous technical challenges along the way from design to assembly to on-orbit anomalies and repairs. The Passive Thermal Control System (PTCS) management team has been a key player in successfully dealing with these challenges. The PTCS team performs thermal analysis in support of design and verification, launch and assembly constraints, integration, sustaining engineering, failure response, and model validation. This analysis is a significant body of work and provides a unique opportunity to compile a wealth of real world engineering and analysis knowledge and the corresponding lessons-learned. The PTCS lessons encompass the full life cycle of flight hardware from design to on-orbit performance and sustaining engineering. These lessons can provide significant insight for new projects and programs. Key areas to be presented include thermal model fidelity, verification methods, analysis uncertainty, and operations support.

Iovine, John V.↗

Development of Sensors and Sensing Technology for Hydrogen Fuel Cell Vehicle Applications

One related area of hydrogen fuel cell vehicle (FCV) development that cannot be overlooked is the anticipated requirement for new sensors for both the monitoring and control of the fuel cell's systems and for those devices that will be required for safety. Present day automobiles have dozens of sensors on-board including those for IC engine management/control, sensors for state-of-health monitoring/control of emissions systems, sensors for control of active safety systems, sensors for triggering passive safety systems, and sensors for more mundane tasks such as fluids level monitoring to name the more obvious. The number of sensors continues to grow every few years as a result of safety mandates but also in response to consumer demands for new conveniences and safety features. Some of these devices (e.g. yaw sensors for dynamic stability control systems or tire presure warning RF-based devices) may be used on fuel cell vehicles without any modification. However the use of hydrogen as a fuel will dictate the development of completely new technologies for such requirements as the detection of hydrogen leaks, sensors and systems to continuously monitor hydrogen fuel purity and protect the fuel cell stack from poisoning, and for the important, yet often taken for granted, tasks such as determining the state of charge of the hydrogen fuel storage and delivery system. Two such sensors that rely on different transduction mechanisms will be highlighted in this presentation. The first is an electrochemical device for monitoring hydrogen levels in air. The other technology covered in this work, is an acoustic-based approach to determine the state of charge of a hydride storage system.

08 HYDROGEN↗

Inherently safe passive gas monitoring system

Generally, the present disclosure is directed to gas monitoring systems that use inductive power transfer to safely power an electrically passive device included within a nuclear material storage container. In particular, the electrically passive device can include an inductive power receiver for receiving inductive power transfer through a wall of the nuclear material storage container. The power received by the inductive power receiver can be used to power one or more sensors included in the device. Thus, the device is not required to include active power generation components such as, for example, a battery, that increase the risk of a spark igniting flammable gases within the container.

24 POWER TRANSMISSION AND DISTRIBUTION↗