Search NASA⌕ Search

SEARCH · Search NASA

Results for “Patient Support System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Real-Time Discovery Services over Large, Heterogeneous and Complex Healthcare Datasets Using Schema-Less, Column-Oriented Methods

We present a service platform for schema-leess exploration of data and discovery of patient-related statistics from healthcare data sets. The architecture of this platform is motivated by the need for fast, schema-less, and flexible approaches to SQL-based exploration and discovery of information embedded in the common, heterogeneously structured healthcare data sets and supporting components (electronic health records, practice management systems, etc.) The motivating use cases described in the paper are clinical trials candidate discovery, and a treatment effectiveness analysis. Following the use cases, we discuss the key features and software architecture of the platform, the underlying core components (Apache Parquet, Drill, the web services server), and the runtime profiles and performance characteristics of the platform. We conclude by showing dramatic speedup with some approaches, and the performance tradeoffs and limitations of others.

Apache Drill Apache Parquet Column Oriented Stores↗

MO-F-CAMPUS-T-04: Development and Evaluation of a Knowledge-Based Model for Treatment Planning of Lung Cancer Patients Using Stereotactic Body Radiotherapy (SBRT)

Purpose: To describe the development of a knowledge-based treatment planning model for lung cancer patients treated with SBRT, and to evaluate the model performance and applicability to different planning techniques and tumor locations. Methods: 105 lung SBRT plans previously treated at our institution were included in the development of the model using Varian’s RapidPlan DVH estimation algorithm. The model was trained with a combination of IMRT, VMAT, and 3D–CRT techniques. Tumor locations encompassed lesions located centrally vs peripherally (43:62), upper vs lower (62:43), and anterior vs posterior lobes (60:45). The model performance was validated with 25 cases independent of the training set, for both IMRT and VMAT. Model generated plans were created with only one optimization and no planner intervention. The original, general model was also divided into four separate models according to tumor location. The model was also applied using different beam templates to further improve workflow. Dose differences to targets and organs-at-risk were evaluated. Results: IMRT and VMAT RapidPlan generated plans were comparable to clinical plans with respect to target coverage and several OARs. Spinal cord dose was lowered in the model-based plans by 1Gy compared to the clinical plans, p=0.008. Splitting the model according to tumor location resulted in insignificant differences in DVH estimation. The peripheral model decreased esophagus dose to the central lesions by 0.5Gy compared to the original model, p=0.025, and the posterior model increased dose to the spinal cord by 1Gy compared to the anterior model, p=0.001. All template beam plans met OAR criteria, with 1Gy increases noted in maximum heart dose for the 9-field plans, p=0.04. Conclusion: A RapidPlan knowledge-based model for lung SBRT produces comparable results to clinical plans, with increased consistency and greater efficiency. The model encompasses both IMRT and VMAT techniques, differing tumor locations, and beam arrangements. Research supported in part by a grant from Varian Medical Systems, Palo Alto CA.

60 APPLIED LIFE SCIENCES↗

Nrf2 protects against airway disorders

Nuclear factor-erythroid 2 related factor 2 (Nrf2) is a ubiquitous master transcription factor that regulates antioxidant response elements (AREs)-mediated expression of antioxidant enzyme and cytoprotective proteins. In the unstressed condition, Kelch-like ECH-associated protein 1 (Keap1) suppresses cellular Nrf2 in cytoplasm and drives its proteasomal degradation. Nrf2 can be activated by diverse stimuli including oxidants, pro-oxidants, antioxidants, and chemopreventive agents. Nrf2 induces cellular rescue pathways against oxidative injury, abnormal inflammatory and immune responses, apoptosis, and carcinogenesis. Application of Nrf2 germ-line mutant mice has identified an extensive range of protective roles for Nrf2 in experimental models of human disorders in the liver, gastrointestinal tract, airway, kidney, brain, circulation, and immune or nerve system. In the lung, lack of Nrf2 exacerbated toxicity caused by multiple oxidative insults including supplemental respiratory therapy (e.g., hyperoxia, mechanical ventilation), cigarette smoke, allergen, virus, bacterial endotoxin and other inflammatory agents (e.g., carrageenin), environmental pollution (e.g., particles), and a fibrotic agent bleomycin. Microarray analyses and bioinformatic studies elucidated functional AREs and Nrf2-directed genes that are critical components of signaling mechanisms in pulmonary protection by Nrf2. Association of loss of function with promoter polymorphisms in NRF2 or somatic and epigenetic mutations in KEAP1 and NRF2 has been found in cohorts of patients with acute lung injury/acute respiratory distress syndrome or lung cancer, which further supports the role for NRF2 in these lung diseases. In the current review, we address the role of Nrf2 in airways based on emerging evidence from experimental oxidative disease models and human studies.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

TU-AB-303-06: Does Online Adaptive Radiation Therapy Mean Zero Margin for Intermediate-Risk Prostate Cancer? An Intra-Fractional Seminal Vesicles Motion Analysis

Purpose: To provide benchmark for seminal vesicles (SVs) margin selection to account for intra-fractional motion; and to investigate the effectiveness of two motion surrogates in predicting intra-fractional SV underdosage. Methods: 9 prostate SBRT patients were studied; each has five pairs of pre-treatment and post-treatment cone-beam CTs (CBCTs). Each pair of CBCTs was registered based on fiducial markers in the prostate. To provide “ground truth” for coverage evaluation, all pre-treatment SVs were expanded with isotropic margin of 1,2,3,5 and 8mm, and their overlap with post-treatment SVs were used to quantify intra-fractional coverage. Two commonly used motion surrogates, the center-of-mass (COM) and the border of contour (the most distal points in SI/AP/LR directions) were evaluated using Receiver-Operating Characteristic (ROC) analyses for predicting SV underdosage due to intra-fractional motion. Action threshold of determining underdosage for each surrogate was calculated by selecting the optimal balancing between sensitivity and specificity. For comparison, margin for each surrogate was also calculated based on traditional margin recipe. Results: 90% post-treatment SV coverage can be achieved in 47%, 82%, 91%, 98% and 98% fractions for 1,2,3,5 and 8mm margins. 3mm margin ensured the 90% intra-fractional SV coverage in 90% fractions when prostate was aligned. The ROC analysis indicated the AUC for COM and border were 0.88 and 0.72. The underdosage threshold was 2.9mm for COM and 4.1mm for border. The Van Herk’s margin recipe recommended 0.5, 0 and 1.8mm margin in LR, AP and SI direction based on COM and for border, the corresponding margin was 2.1, 4.5 and 3mm. Conclusion: 3mm isotropic margin is the minimum required to mitigate the intra-fractional SV motion when prostate is aligned. ROC analysis reveals that both COM and border are acceptable predictors for SV underdosage with 2.9mm and 4.1mm action threshold. Traditional margin calculation is less reliable for this application. This work is partially supported a master research grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

SU-D-204-07: Retrospective Correlation of Dose Accuracy with Regions of Local Failure for Early Stage Lung Cancer Patients Treated with Stereotactic Body Radiotherapy

Purpose: To correlate dose distributions computed using six algorithms for recurrent early stage non-small cell lung cancer (NSCLC) patients treated with stereotactic body radiotherapy (SBRT), with outcome (local failure). Methods: Of 270 NSCLC patients treated with 12Gyx4, 20 were found to have local recurrence prior to the 2-year time point. These patients were originally planned with 1-D pencil beam (1-D PB) algorithm. 4D imaging was performed to manage tumor motion. Regions of local failures were determined from follow-up PET-CT scans. Follow-up CT images were rigidly fused to the planning CT (pCT), and recurrent tumor volumes (Vrecur) were mapped to the pCT. Dose was recomputed, retrospectively, using five algorithms: 3-D PB, collapsed cone convolution (CCC), anisotropic analytical algorithm (AAA), AcurosXB, and Monte Carlo (MC). Tumor control probability (TCP) was computed using the Marsden model (1,2). Patterns of failure were classified as central, in-field, marginal, and distant for Vrecur ≥95% of prescribed dose, 95–80%, 80–20%, and ≤20%, respectively (3). Results: Average PTV D95 (dose covering 95% of the PTV) for 3-D PB, CCC, AAA, AcurosXB, and MC relative to 1-D PB were 95.3±2.1%, 84.1±7.5%, 84.9±5.7%, 86.3±6.0%, and 85.1±7.0%, respectively. TCP values for 1-D PB, 3-D PB, CCC, AAA, AcurosXB, and MC were 98.5±1.2%, 95.7±3.0, 79.6±16.1%, 79.7±16.5%, 81.1±17.5%, and 78.1±20%, respectively. Patterns of local failures were similar for 1-D and 3D PB plans, which predicted that the majority of failures occur in centraldistal regions, with only ∼15% occurring distantly. However, with convolution/superposition and MC type algorithms, the majority of failures (65%) were predicted to be distant, consistent with the literature. Conclusion: Based on MC and convolution/superposition type algorithms, average PTV D95 and TCP were ∼15% lower than the planned 1-D PB dose calculation. Patterns of failure results suggest that MC and convolution/superposition type algorithms predict different outcomes for patterns of failure relative to PB algorithms. Work supported in part by Varian Medical Systems, Palo Alto, CA.

60 APPLIED LIFE SCIENCES↗

TH-EF-BRA-08: A Novel Technique for Estimating Volumetric Cine MRI (VC-MRI) From Multi-Slice Sparsely Sampled Cine Images Using Motion Modeling and Free Form Deformation

Purpose: To develop a technique to estimate on-board VC-MRI using multi-slice sparsely-sampled cine images, patient prior 4D-MRI, motion-modeling and free-form deformation for real-time 3D target verification of lung radiotherapy. Methods: A previous method has been developed to generate on-board VC-MRI by deforming prior MRI images based on a motion model(MM) extracted from prior 4D-MRI and a single-slice on-board 2D-cine image. In this study, free-form deformation(FD) was introduced to correct for errors in the MM when large anatomical changes exist. Multiple-slice sparsely-sampled on-board 2D-cine images located within the target are used to improve both the estimation accuracy and temporal resolution of VC-MRI. The on-board 2D-cine MRIs are acquired at 20–30frames/s by sampling only 10% of the k-space on Cartesian grid, with 85% of that taken at the central k-space. The method was evaluated using XCAT(computerized patient model) simulation of lung cancer patients with various anatomical and respirational changes from prior 4D-MRI to onboard volume. The accuracy was evaluated using Volume-Percent-Difference(VPD) and Center-of-Mass-Shift(COMS) of the estimated tumor volume. Effects of region-of-interest(ROI) selection, 2D-cine slice orientation, slice number and slice location on the estimation accuracy were evaluated. Results: VCMRI estimated using 10 sparsely-sampled sagittal 2D-cine MRIs achieved VPD/COMS of 9.07±3.54%/0.45±0.53mm among all scenarios based on estimation with ROI-MM-ROI-FD. The FD optimization improved estimation significantly for scenarios with anatomical changes. Using ROI-FD achieved better estimation than global-FD. Changing the multi-slice orientation to axial, coronal, and axial/sagittal orthogonal reduced the accuracy of VCMRI to VPD/COMS of 19.47±15.74%/1.57±2.54mm, 20.70±9.97%/2.34±0.92mm, and 16.02±13.79%/0.60±0.82mm, respectively. Reducing the number of cines to 8 enhanced temporal resolution of VC-MRI by 25% while maintaining the estimation accuracy. Estimation using slices sampled uniformly through the tumor achieved better accuracy than slices sampled non-uniformly. Conclusions: Preliminary studies showed that it is feasible to generate VC-MRI from multi-slice sparsely-sampled 2D-cine images for real-time 3D-target verification. This work was supported by the National Institutes of Health under Grant No. R01-CA184173 and a research grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

SU-E-J-114: A Practical Hybrid Method for Improving the Quality of CT-CBCT Deformable Image Registration for Head and Neck Radiotherapy

Purpose: Accurate deformable image registration (DIR) between CT and CBCT in H&N is challenging. In this study, we propose a practical hybrid method that uses not only the pixel intensities but also organ physical properties, structure volume of interest (VOI), and interactive local registrations. Methods: Five oropharyngeal cancer patients were selected retrospectively. For each patient, the planning CT was registered to the last fraction CBCT, where the anatomy difference was largest. A three step registration strategy was tested; Step1) DIR using pixel intensity only, Step2) DIR with additional use of structure VOI and rigidity penalty, and Step3) interactive local correction. For Step1, a public-domain open-source DIR algorithm was used (cubic B-spline, mutual information, steepest gradient optimization, and 4-level multi-resolution). For Step2, rigidity penalty was applied on bony anatomies and brain, and a structure VOI was used to handle the body truncation such as the shoulder cut-off on CBCT. Finally, in Step3, the registrations were reviewed on our in-house developed software and the erroneous areas were corrected via a local registration using level-set motion algorithm. Results: After Step1, there were considerable amount of registration errors in soft tissues and unrealistic stretching in the posterior to the neck and near the shoulder due to body truncation. The brain was also found deformed to a measurable extent near the superior border of CBCT. Such errors could be effectively removed by using a structure VOI and rigidity penalty. The rest of the local soft tissue error could be corrected using the interactive software tool. The estimated interactive correction time was approximately 5 minutes. Conclusion: The DIR using only the image pixel intensity was vulnerable to noise and body truncation. A corrective action was inevitable to achieve good quality of registrations. We found the proposed three-step hybrid method efficient and practical for CT/CBCT registrations in H&N. My department receives grant support from Industrial partners: (a) Varian Medical Systems, Palo Alto, CA, and (b) Philips HealthCare, Best, Netherlands.

60 APPLIED LIFE SCIENCES↗

Novel dosimetric phantom for quality assurance of volumetric modulated arc therapy

The objective of this work is to assess the suitability and performance of a new dosimeter system with a novel geometry for the quality assurance (QA) of volumetric modulated arc therapy (VMAT). The new dosimeter system consists of a hollow cylinder (15 and 25 cm inner and outer diameters) with 124 diodes embedded in the phantom's cylindrical wall forming four rings of detectors. For coplanar beams, the cylindrical geometry and the ring diode pattern offer the advantage of invariant perpendicular incidence on the beam central axis for any gantry angle and also have the benefit of increasing the detector density as both walls of the cylinder sample the beam. Other advantages include real-time readout and reduced weight with the hollow phantom shape. A calibration method taking into account the variation in radiation sensitivity of the diodes as a function of gantry angle was developed and implemented. In this work, the new dosimeter system was used in integrating mode to perform composite dose measurements along the cylindrical surface supporting the diodes. The reproducibility of the dosimeter response and the angular dependence of the diodes were assessed using simple 6 MV photon static beams. The performance of the new dosimeter system for VMAT QA was then evaluated using VMAT plans designed for a head and neck, an abdominal sarcoma, and a prostate patient. These plans were optimized with 90 control points (CPs) and additional versions of each plan were generated by increasing the number of CPs to 180 and 360 using linear interpolation. The relative dose measured with the dosimeter system for the VMAT plans was compared to the corresponding TPS dose map in terms of relative dose difference (%{Delta}D) and distance to agreement (DTA). The dosimeter system's sensitivity to gantry rotation offset and scaling errors as well as setup errors was also evaluated. For static beams, the dosimeter system offered good reproducibility and demonstrated small residual diode angular dependence after calibration. For VMAT deliveries, the agreement between measured and calculated doses was good with {>=}86.4% of the diodes satisfying 3% of %{Delta}D or 2 mm DTA for the 180 CP plans. The phantom offered sufficient sensitivity for the detection of small gantry rotation offset (3 deg.) and scaling errors (1 deg.) as well as phantom setup errors of 1 mm, although the results were plan dependent. With its novel geometry, the dosimeter system was also able to experimentally demonstrate the discretization effect of the number of CPs used in the TPS to simulate a continuous arc. These results demonstrate the suitability of the new dosimeter system for the patient-specific QA of VMAT plans and suggest that the dosimeter system can be an effective tool in the routine QA and commissioning of treatment machines capable of VMAT delivery and cone-beam CT image guidance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of vestibular loss on head stabilization in response to head and body perturbations

Control of head position during postural responses is important to facilitate both the interpretation of vestibular signals and the stabilization of gaze. In these experiments, we compared head stabilization for two different postural tasks: 1) in response to perturbations at the head, and 2) in response to perturbations induced at the support surface, which perturb both body and head position. To determine whether normal vestibular function is necessary for head stabilization in these two tasks, responses to forward and backward mechanical perturbations of the head and body were compared for 13 normal subjects and 4 patients with profound bilateral vestibular loss (two with vestibular loss in adulthood and two in infancy). Normal subjects showed little neck muscle activity for body perturbations, but large, early activations in both neck extensors and flexors for head perturbations. In contrast, vestibular patients showed excessive neck muscle activation for body perturbations and reduced or absent neck muscle activity for head perturbations. Patients with vestibular loss in adulthood also showed increased head acceleration in response to both head and body perturbations, but patients with vestibular loss in infancy showed more normal head accelerations. For body perturbations, the differences in head acceleration between patients and normals were greater for later head acceleration peaks, indicating poor head control during the execution of the postural response. Trunk angle changes were also higher in the patients for forward body perturbations, indicating that poorer control of trunk position could have contributed to their poorer head stabilization. These results indicate that the vestibular system plays an important role in head and trunk stabilization for both head and body perturbations. However, the more normal head accelerations of the patients with infant vestibular loss also indicate that other mechanisms, possibly involving neck reflexes, can at least partially substitute for the vestibular system to provide head and trunk stabilization.

NASA Discipline Neuroscience↗

Announcing the Biomedical Data Translator: Initial Public Release

ABSTRACT The growing availability of biomedical data offers vast potential to improve human health, but the complexity and lack of integration of these datasets often limit their utility. To address this, the Biomedical Data Translator Consortium has developed an open‐source knowledge graph–based system—Translator—designed to integrate, harmonize, and make inferences over diverse biomedical data sources. We announce here Translator's initial public release and provide an overview of its architecture, standards, user interface, and core features. Translator employs a scalable, federated, knowledge graph framework for the integration of clinical, genomic, pharmacological, and other biomedical knowledge sources, enabling query retrieval, inference, and hypothesis generation. Translator's user interface is designed to support the exploration of knowledge relationships and the generation of insights, without requiring deep technical expertise and gradually revealing more detailed evidence, provenance, and confidence information, as needed by a given user. To demonstrate Translator's application and impact, we highlight features of the user interface in the context of three real‐world use cases: suggesting potential therapeutics for patients with rare disease; explaining the mechanism of action of a pipeline drug; and screening and validating drug candidates in a model organism. We discuss strengths and limitations of reasoning within a largely federated system and the need for rich concept modeling and deep provenance tracking. Finally, we outline future directions for enhancing Translator's functionality and expanding its data sources. Translator represents a significant step forward in making complex biomedical knowledge more accessible and actionable, aiming to accelerate translational research and improve patient care.

Research & Experimental Medicine↗

Tunable White Light for Elders (TWLITE): A Protocol Demonstrating Feasibility and Acceptability for Deployment, Remote Data Collection, and Analysis of a Home-Based Lighting Intervention in Older Adults

Sleep disturbances are common in older adults and may contribute to disease progression in certain populations (e.g., Alzheimer’s disease). Light therapy is a simple and cost-effective intervention to improve sleep. Primary barriers to light therapy are: (1) poor acceptability of the use of devices, and (2) inflexibility of current devices to deliver beyond a fixed light spectrum and throughout the entirety of the day. However, dynamic, tunable lighting integrated into the native home lighting system can potentially overcome these limitations. Herein, we describe our protocol to implement a whole-home tunable lighting system installed throughout the homes of healthy older adults already enrolled in an existing study with embedded home assessment platforms (Oregon Center for Aging & Technology—ORCATECH). Within ORCATECH, continuous data on room location, activity, sleep, and general health parameters are collected at a minute-to-minute resolution over years of participation. This single-arm longitudinal protocol collected participants’ light usage in addition to ORCATECH outcome measures over a several month period before and after light installation. The protocol was implemented with four subjects living in three ORCATECH homes. Technical/usability challenges and feasibility/acceptability outcomes were explored. The successful implementation of our protocol supports the feasibility of implementing and integrating tunable whole-home lighting systems into an automated home-based assessment platform for continuous data collection of outcome variables, including long-term sleep measures. Challenges and iterative approaches are discussed. This protocol will inform the implementation of future clinical intervention trials using light therapy in patients at risk for developing Alzheimer’s disease and related conditions.

60 APPLIED LIFE SCIENCES↗

Linking Asthma Exacerbation and Air Pollution Data: A Step Toward Public Health and Environmental Data Integration

Studies have shown that reducing exposure to triggers such as air pollutants can reduce symptoms and the need for medication in asthma patients. However, systems that track asthma are generally not integrated with those that track environmental hazards related to asthma. Tlvs lack of integration hinders public health awareness and responsiveness to these environmental triggers. The current study is a collaboration between health and environmental professionals to utilize NASA-derived environmental data to develop a decision support system (DSS) for asthma prediction, surveillance, and intervention. The investigators link asthma morbidity data from the University of Mississippi Medical Center (UMMC) and Mississippi Department of Health (MDH) with air quality data from the Mississippi Department of Environmental Quality (MDEQ) and remote sensing data from NASA. Daily ambient environmental hazard data for PM2.5 and ozone are obtained from the MDEQ air quality monitoring locations and are combined with remotely sensed data from NASA to develop a state-wide spatial and time series profile of environmental air quality. These data are then used to study the correlation of these measures of air quality variation with the asthma exacerbation incidence throughout the state over time. The goal is to utilize these readily available measures to allow real-time risk assessment for asthma exacerbations. GeoMedStat, a DSS previously developed for biosurveillance, will integrate these measures to monitor, analyze and report the real-time risk assessment for asthma exacerbation throughout the state.

Faruque, Fazlay↗

SU-E-J-170: Beyond Single-Cycle 4DCT: Maximum a Posteriori (MAP) Reconstruction-Based Binning-Free Multicycle 4DCT for Lung Radiotherapy

Purpose: Thoracic motion changes from cycle-to-cycle and day-to-day. Conventional 4DCT does not capture these cycle to cycle variations. We present initial results of a novel 4DCT reconstruction technique based on maximum a posteriori (MAP) reconstruction. The technique uses the same acquisition process (and therefore dose) as a conventional 4DCT in order to create a high spatiotemporal resolution cine CT that captures several breathing cycles. Methods: Raw 4DCT data were acquired from a lung cancer patient. The continuous 4DCT was reconstructed using MAP algorithm which uses the raw, time-stamped CT data to reconstruct images while simultaneously estimating deformation in the subject's anatomy. This framework incorporates physical effects such as hysteresis and is robust to detector noise and irregular breathing patterns. The 4D image is described in terms of a 3D reference image defined at one end of the hysteresis loop, and two deformation vector fields (DVFs) corresponding to inhale motion and exhale motion respectively. The MAP method uses all of the CT projection data and maximizes the log posterior in order to iteratively estimate a timevariant deformation vector field that describes the entire moving and deforming volume. Results: The MAP 4DCT yielded CT-quality images for multiple cycles corresponding to the entire duration of CT acquisition, unlike the conventional 4DCT, which only yielded a single cycle. Variations such as amplitude and frequency changes and baseline shifts were clearly captured by the MAP 4DC Conclusion: We have developed a novel, binning-free, parameterized 4DCT reconstruction technique that can capture cycle-to-cycle variations of respiratory motion. This technique provides an invaluable tool for respiratory motion management research. This work was supported by funding from the National Institutes of Health and VisionRT Ltd. Amit Sawant receives research funding from Varian Medical Systems, Vision RT and Elekta.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP4-04: An Automated Monte Carlo Based QA Framework for Pencil Beam Scanning Treatments

Purpose: Prior to treating new PBS field, multiple (three) patient-field-specific QA measurements are performed: two 2D dose distributions at shallow depth (M1) and at the tumor depth (M2) with treatment hardware at zero gantry angle; one 2D dose distribution at iso-center (M3) without patient specific devices at the planned gantry angle. This patient-specific QA could be simplified by the use of MC model. The results of MC model commissioning for a spot-scanning system and the fully automated TOPAS/MC-based QA framework will be presented. Methods: We have developed in-house MC interface to access a TPS (Astroid) database from a computer cluster remotely. Once a plan is identified, the interface downloads information for the MC simulations, such as patient images, apertures points, and fluence maps and initiates calculations in both the patient and QA geometries. The resulting calculations are further analyzed to evaluate the TPS dose accuracy and the PBS delivery. Results: The Monte Carlo model of our system was validated within 2.0 % accuracy over the whole range of the dose distribution (proximal/shallow part, as well as target dose part) due to the location of the measurements. The averaged range difference after commissioning was 0.25 mm over entire treatment ranges, e.g., 6.5 cm to 31.6 cm. Conclusion: As M1 depths range typically from 1 cm to 4 cm from the phantom surface, The Monte Carlo model of our system was validated within +− 2.0 % in absolute dose level over a whole treatment range. The averaged range difference after commissioning was 0.25 mm over entire treatment ranges, e.g., 6.5 cm to 31.6 cm. This work was supported by NIH/NCI under CA U19 21239.

60 APPLIED LIFE SCIENCES↗

Using Natural Language Processing of Free-Text Radiology Reports to Identify Type 1 Modic Endplate Changes

Electronic medical record (EMR) systems provide easy access to radiology reports and offer great potential to support quality improvement efforts and clinical research. Harnessing the full potential of the EMR requires scalable approaches such as natural language processing (NLP) to convert text into variables used for evaluation or analysis. Our goal was to determine the feasibility of using NLP to identify patients with Type 1 Modic endplate changes using clinical reports of magnetic resonance (MR) imaging examinations of the spine. Identifying patients with Type 1 Modic change who may be eligible for clinical trials is important as these findings may be important targets for intervention. Four annotators identified all reports that contained Type 1 Modic change, using N = 458 randomly selected lumbar spine MR reports. We then implemented a rule-based NLP algorithm in Java using regular expressions. The prevalence of Type 1 Modic change in the annotated dataset was 10%. Results were recall (sensitivity) 35/50 = 0.70 (95% confidence interval (C.I.) 0.52–0.82), specificity 404/408 = 0.99 (0.97–1.0), precision (positive predictive value) 35/39 = 0.90 (0.75–0.97), negative predictive value 404/419 = 0.96 (0.94–0.98), and F1-score 0.79 (0.43–1.0). Our evaluation shows the efficacy of rule-based NLP approach for identifying patients with Type 1 Modic change if the emphasis is on identifying only relevant cases with low concern regarding false negatives. As expected, our results show that specificity is higher than recall. This is due to the inherent difficulty of eliciting all possible keywords given the enormous variability of lumbar spine reporting, which decreases recall, while availability of good negation algorithms improves specificity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Market Survey 2020: Commercial Clinical Decision Support Systems and Wellness Tools

For long-duration, deep space exploration missions, current methods for managing and supporting crew health and medical conditions will be unsuitable. Communication and data transmission lags will necessitate the use of a sophisticated clinical decision support system (CDSS) that will tailor diagnosis and treatment guidance that is context-sensitive for anticipated astronaut health, wellness, and medical conditions. A variety of clinical decision support (CDS) and wellness tools (WT) are currently available in the commercial market and a broad-brush survey of this market can provide an initial impression of the current state of the art which, in turn, can inform the roadmap of NASA deep space CDSS development and associated requirements. Such a survey was undertaken during the first six months of 2020 using directed convenience sampling to obtain information provided by vendors on their websites; both commercially available CDS and WT (such as those used to track and monitor nutrition, exercise, and sleep) were included. Areas assessed were item type (e.g., software/application, device); primary purpose of the item (e.g., diagnostic support, nutrition tracking); additional purposes (if any); reported features, capabilities, and functionality; setting of use (e.g., inpatient, outpatient); intended user (e.g., clinician, patient); location and sources of data/information used or produced by the item; integration with patient electronic health record (EHR); compliance with interoperability ontologies and standards (e.g., Health Level 7 [HL7], Systematized Nomenclature of Medicine – Clinical Terminology [SNOMED-CT]); and whether the item is knowledge-based (derived from research findings) or non-knowledge-based (derived through artificial intelligence, machine learning, advanced probability and statistics), among others. Ninety-seven (97) vendor websites describing 196 CDS and 73 WT (269 total) were reviewed and coded. The primary purpose of the majority of CDS reviewed is diagnosis or diagnosis/treatment/drug decision support—targeted for clinician use— and the primary purpose of the majority of WT reviewed is the monitoring of different health metrics, most often through the use of a biosensor device (e.g., blood pressure)—targeted for patient use. Very few CDS or WT appear to comply with major international interoperability standards or can be integrated with a patient’s EHR data. None consider contextual factors, such as conditions of the physical environment (e.g., CO2 levels). The majority of CDS and WT reviewed are non-knowledge, cloud- or web-based applications or software. Forty-three (43) major findings were identified and the implications those findings have for NASA will be discussed. Example major findings include: CDS-WT capabilities range from diagnosis to treatment applications, CDS-WT may be wearable or non-wearable and are technologically advanced and only a few CDS-WT tools referenced compliance to ensure interoperability, among other findings. Recommendations will also be offered that will help to address ExMC Gap, Medical-701: Enhance medical capabilities within an exploration medical system.

market survey↗

Uncertainty Analysis Framework for the Hospital Resource Supply Model for Covid-19

In March and April of 2020 there was widespread concern about availability of medical resources required to treat Covid-19 patients who become seriously ill. A simulation model of supply management was developed to aid understanding of how to best manage available supplies and channel new production. Forecasted demands for critical therapeutic resources have tremendous uncertainty, largely due to uncertainties about the number and timing of patient arrivals. It is therefore essential to evaluate any process for managing supplies in view of this uncertainty. To support such evaluations, we developed a modeling framework that would allow an integrated assessment in the context of uncertainty quantification. At the time of writing there has been no need to execute this framework because adaptations of the medical system have been able to respond effectively to the outbreak. This report documents the framework and its implemented components should need later arise for its application.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Prototyping a self-learning digital twin platform for personalized treatment in melanoma patients (Final Report)

We completed all the Milestones and disseminated results at the 2021 Computational Approaches for Cancer Workshop (CAFCW21) at the SuperComputing21 conference. As part of Milestone 1, we developed and implemented a prototype digital twin of metastatic melanoma patients, performed quality checks on the code and released it as open source. The work has directly driven major grant proposals by the team on computational digital twins and supporting software infrastructure, including a successful fellowship application by the PI. Work was lead by Paul Macklin (Contact PI, Indiana University), in collaboration with Ilya Shmulevich (PI, Institute for Systems Biology), Tina Hernandez-Boussard (PI, Stanford Univ.), Jeffrey Bryan (Co-I, University of Missouri), Snigdhansu Chatterjee (Co-I, University of Minnesota), and Mohammad Fallahi-Sichani (Co-I, U. of Virginia). Postdoctoral student Heber L. Rocha (Macklin lab, IU) performed intensive computational work, in collaboration with Senior Research Scientist Boris Aguilar (Shmulevich lab, ISB).

59 BASIC BIOLOGICAL SCIENCES↗