Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance, Reliability, Design, Measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Assessing the Heat Transfer Modeling Capabilities of CFD Software for Involute-Shaped Plate Research Reactors

The ongoing efforts to convert High-Performance Research Reactors (HPRRs) using Highly Enriched Uranium (HEU) to Low-Enriched Uranium (LEU) fuel require reliable thermal–hydraulic assessments of modified core designs. The involute-shaped fuel plates used in several major HPRRs present unique modeling challenges due to their compact core geometries and high heat flux conditions. This study evaluates the capability of three commercial CFD tools, STAR-CCM+, COMSOL, and ANSYS CFX, to predict cladding-to-coolant heat transfer using Reynolds-Averaged Navier–Stokes (RANS) methods within the thermal–hydraulic regimes of involute-shaped plate reactors. Broad sensitivity analysis was conducted across a range of reactor-relevant parameters using two turbulence models (k−ϵ and k−ω SST) and different near-wall treatment strategies. The results were benchmarked against the Sieder–Tate correlation and experimental data from historic studies. The codes produced consistent results, showing good agreement with the empirical correlation of Sieder–Tate and the experimental measurements. The findings support the use of these commercial CFD codes as effective tools for assessing the thermal–hydraulic performance of involute-shaped plate HPRRs and guide future LEU core development.

CFD↗

Constraining the impact of chlorine as a neutron absorber in next-gen fast reactor designs

The role of chlorine as a neutron poison and as a seed for producing radioactive waste in nuclear systems has driven a renewed interest to improve its nuclear data uncertainties. Additionally, basic and applied science programs that use CLYC (Cs 2 LiYCl 6 :Ce) detectors for neutron spectroscopy and monitoring are also very sensitive to any change in chlorine nuclear data for simulations of the detector response. In this work, sensitivities relevant for these different applications are addressed through simulations of the efficiency of CLYC detectors in a fast fission spectrum when applying new chlorine nuclear data as input. These simulations are validated by an experimental measurement using CLYC detectors coupled to an ionization chamber loaded with a 252 Cf spontaneous fission source. The results are then used to obtain the first reliable direct measurement of the 35 Cl(n,p 0 ) and summed Cl(n,p+n,α) fission spectrum average cross sections, found to be 54.7(32) and 105.0(98) mb, respectively. The results are within uncertainty of calculated fission spectrum averaged cross sections based on recently re-evaluated chlorine nuclear data, which confirm recent impact studies performed for the Molten Chloride Reactor Experiment. Meanwhile, there currently exists only one published criticality benchmark experiment that is sufficiently sensitive to chlorine nuclear data. Discrepancies are found with this set of criticality safety benchmarks, which are more sensitive to thermal and epithermal neutron energies than the energies, above 100 keV, tested in this current work. Hence, there is still a need to re-evaluate the chlorine nuclear data at lower energies to assess these discrepancies. Interpretation of the data from future “faster” criticality benchmarks, which are needed for next-gen fast reactor designs, benefit from the improved constraints on the chlorine nuclear data validated in this work.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on a Hanford AP Tank Farm Exhauster Slipstream (Volume 1)

Washington River Protection Solutions (WRPS) tested four types of chemical cartridges for use in air-purifying respirators (APR) and powered air-purifying respirators (PAPR). These tests were undertaken to determine the period of time that the cartridges would provide adequate performance1 for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the Hanford AP tank farm exhauster slipstream. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing cartridge change schedules. Testing commonly is applied in situations where mixtures of COPCs exist and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Cartridge testing on a slipstream from the Hanford AP tank exhauster was conducted on March 23-24, 2018. This testing focused on both APR and PAPR cartridges. Previous testing of APR cartridges was conducted on the AP exhauster in June of 2016. However, an AP exhauster upgrade was completed in September 2016. In the most recent testing, slipstream vapors from the new AP exhauster were fed to two respirator cartridge test stands, one for the PAPR respirator cartridges and the other for the APR respirator cartridges. Both the APR and PAPR test stands were developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose APR cartridges—SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina)—were assessed on separate days using the APR cartridge test stand. Multipurpose PAPR cartridges—MSA OptiFilter TL (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR-57 (3M Company, Maplewood, Minnesota)—were also tested consecutively over the same two days as the APR cartridge tests, using the PAPR cartridge test stand. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges, and the samples then were analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

61 RADIATION PROTECTION AND DOSIMETRY↗

Design Features of the Neutral Particle Diagnostic System for the ITER Tokamak

The control of the deuterium–tritium (DT) fuel isotopic ratio has to ensure the best performance of the ITER thermonuclear fusion reactor. The diagnostic system described in this paper allows the measurement of this ratio analyzing the hydrogen isotope fluxes (performing neutral particle analysis (NPA)). The development and supply of the NPA diagnostics for ITER was delegated to the Russian Federation. The diagnostics is being developed at the Ioffe Institute. The system consists of two analyzers, viz., LENPA (Low Energy Neutral Particle Analyzer) with 10–200 keV energy range and HENPA (High Energy Neutral Particle Analyzer) with 0.1–4.0MeV energy range. Simultaneous operation of both analyzers in different energy ranges enables researchers to measure the DT fuel ratio both in the central burning plasma (thermonuclear burn zone) and at the edge as well. When developing the diagnostic complex, it was necessary to account for the impact of several factors: high levels of neutron and gamma radiation, the direct vacuum connection to the ITER vessel, implying high tritium containment, strict requirements on reliability of all units and mechanisms, and the limited space available for accommodation of the diagnostic hardware at the ITER tokamak. The paper describes the design of the diagnostic complex and the engineering solutions that make it possible to conduct measurements under tokamak reactor conditions. The proposed engineering solutions provide a safe—with respect to thermal and mechanical loads—common vacuum channel for hydrogen isotope atoms to pass to the analyzers; ensure efficient shielding of the analyzers from the ITER stray magnetic field (up to 1 kG); provide the remote control of the NPA diagnostic complex, in particular, connection/disconnection of the NPA vacuum beamline from the ITER vessel; meet the ITER radiation safety requirements; and ensure measurements of the fuel isotopic ratio under high levels of neutron and gamma radiation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

In-Containment Signal Acquisition and Data Transmission via Power Lines within High Dose Areas of Nuclear Power Plants

Signal acquisition and data transmission for innovative sensor systems and networks inside the containment of nuclear power plants (NPPs) is still a challenge with respect to safety, performance, reliability, availability, and costs. This especially applies to equipment upgrades for existing plants, special measurements, but also for new builds. This paper presents a novel method for efficient and cost-effective sensor signal acquisition and data transmission via power lines, in order to cope with the disadvantages of common system architectures that often suffer from poor signal integrity due to raw data transmissions via long cables, huge efforts and costs for installation, and low flexibility with respect to maintenance and upgrades. A transmitter-receiver architecture is proposed that allows multiplexing of multiple sensor inputs for unidirectional point-to-point transmission by superimposing information signals on existing AC or DC supply lines, but also on active and inactive sensor wires, or spare cables, using power line communication (PLC) technology. Based on commercial off-the-shelf (COTS) electronic parts, a radiation hard transmitter hardware is designed to operate in harsh environment within the containment during full plant operation. The system's modular approach allows application specific trade-offs between redundancy and throughput regarding data transmission, as well as various sensor input front-ends which are compatible with state of the art systems. PLC technology eliminates the need for costly installation of additional cables and wall penetrations, while providing a complementary and diverse communication technology for upgrades of existing systems. At the receiver side in low dose areas, signals are extracted from the power line, demodulated, and de-multiplexed, in order to regain the original sensor signal information and provide it either in analog or digital output format. Successful laboratory qualification tests, field trails, and a demonstrator setup installation within a NPP verify the overall performance of the proposed system. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Self-assembled nanoparticle aggregates: Organizing disorder for high performance surface-enhanced spectroscopy

The coherent oscillations of the surface electron gas, known as surface plasmons, in metal nanostructures can give rise to the localization of intense electromagnetic fields at the metal-dielectric interface. These strong fields are exploited in surface enhanced spectroscopies, such as Surface Enhanced Raman Scattering (SERS), for the detection and characterization of molecules at very low concentration. Still, the implementation of SERS-based biosensors requires a high level of reproducibility, combined with cheap and simple fabrication methods. For this purpose, SERS substrates based on self-assembled aggregates of commercial metallic nanoparticles (Nps) can meet all the above requests. Following this line, we report on a combined micro-Raman and Atomic Force Microscopy (AFM) analysis of the SERS efficiency of micrometric silver Np aggregates (enhancement factors up to 10{sup 9}) obtained by self-assembly. Despite the intrinsic disordered nature of these Np clusters, we were able to sort out some general rules relating the specific aggregate morphology to its plasmonic response. We found strong evidences of cooperative effects among the NPs within the cluster and namely a clear dependence of the SERS-efficiency on both the cluster area (basically linear) and the number of stacked NPs layers. A cooperative action among the superimposed layers has been proved also by electromagnetic simulations performed on simplified nanostructures consisting of stacking planes of ordered Nps. Being clear the potentialities of these disordered self-assembled clusters, in terms of both easy fabrication and signal enhancement, we developed a specific nanofabrication protocol, based on electron beam lithography and molecular functionalization, that allowed for a fine control of the Np assemblies into designed shapes fixing their area and height. In particular, we fabricated 2D ordered arrays of disordered clusters choosing gold Nps owing to their high stability. AFM measurements confirmed the regularity in spacing and size (i.e. area and layer number) of the aggregates. Preliminary SERS measurements confirm the high signal enhancement and demonstrate a quite good reproducibility over large number of aggregates within 100×100 μm{sup 2} 2D super-structure. The availability of such a multisensor could allow a careful statistical analysis of the SERS response, thus leading to a reliable quantitative estimate of the presence of relevant molecular species even at ultra-low concentration.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Convective heat transfer to CO{sub 2} at a supercritical pressure flowing vertically upward in tubes and an annular channel

The Super-Critical Water-Cooled Reactor (SCWR) has been chosen by the Generation IV International Forum as one of the candidates for the next generation nuclear reactors. Heat transfer to water from a fuel assembly may deteriorate at certain supercritical pressure flow conditions and its estimation at degraded conditions as well as in normal conditions is very important to the design of a safe and reliable reactor core. Extensive experiments on a heat transfer to a vertically upward flowing CO{sub 2} at a supercritical pressure in tubes and an annular channel have been performed. The geometries of the test sections include tubes of an internal diameter (ID) of 4.4 and 9.0 mm and an annular channel (8 x 10 mm). The heat transfer coefficient (HTC) and Nusselt numbers were derived from the inner wall temperature converted by using the outer wall temperature measured by adhesive K-type thermocouples and a direct (tube) or indirect (annular channel) electric heating power. From the test results, a correlation, which covers both a deteriorated and a normal heat transfer regime, was developed. The developed correlation takes different forms in each interval divided by the value of parameter Bu. The parameter Bu (referred to as Bu hereafter), a function of the Grashof number, the Reynolds number and the Prandtl number, was introduced since it is known to be a controlling factor for the occurrence of a heat transfer deterioration due to a buoyancy effect. The developed correlation predicted the HTCs for water and HCFC-22 fairly well. (author)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Comparison between Alcator C-Mod ICRF experiments and 3D full wave simulations

Reliable modeling of ion cyclotron range of frequencies (ICRF) antenna performance is essential for interpreting present experiments and guiding the design of future reactors. In this work, a 3D model of the Alcator C-Mod field-aligned antenna is implemented in the Petra-M finite-element framework [S. Shiraiwa et al 2023 Nucl. Fusion 63 026024] and benchmarked against experimental results. Four experimental cases are examined. First, the simulated rectified sheath potentials on the antenna limiters are compared with measurements from a power tapering experiment. Second, proof-of-principle far-field sheath simulations are performed. In scenarios with low single-pass absorption, simulations predict enhanced sheath potentials on a distant poloidal limiter in the far field of the antenna, consistent with experimental observations. Third, the simulated antenna loading during edge localized modes follows experimental trends and appears to be dominated by the density gradient at the pedestal. Finally, Petra-M predicts the unintended excitation of high-$k$ ∥ modes during monopole phasing operation, in agreement with experimental evidence of poor wave coupling and accessibility to the plasma core. Overall, reasonable agreement is found between the simulations and experiments. At the same time, areas of imperfect agreement are identified. These provide important guidance on the limits of the current state-of-the-art modeling, which should be kept in mind when using it as a predictive tool for future reactors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of Readily Available & Robust High Heat Flux Gardon Gauges

Concentrated solar power (CSP) technologies deliver concentrated solar energy as a heat source to industrial processes, power generation cycles, and chemical cycles. CSP systems require accurate and reliable high flux measurements, and next generation CSP systems will require flux measurement up to 1000 W/cm2. Existing flux measurement devices do not comprehensively meet the flux rating, cycle life, cost, and lead-time needs of stakeholders, necessitating the development of an improved flux sensor. In this study, Sandia National Laboratories (SNL) partnered with Hukseflux Thermal Sensors to develop a low-cost, short lead-time, and robust flux sensor rated to 250 W/cm2. Three prototype circular foil gauge designs were assessed for performance at the National Solar Thermal Test Facility (NSTTF) at SNL. Each gauge design measured flux up to 250 W/cm2 with <5% measurement error. Following baseline error quantification, gauges were exposed to flux above 500 W/cm2 to assess gauge failure mechanisms. Gauges physically survived >500 W/cm2 flux exposure, but measurement error was found to increase after foil coatings reached 400 °C. The results of this study suggest that coating optical properties change at excessive temperatures and that foil coating temperature, rather than heat flux level, dictates the acceptable gauge measurement range.

McLaughlin, Luke (ORCID:0000000303711310)↗

Evaluation of calibration efficacy under different levels of uncertainty

This study examines how calibration performs under different levels of uncertainty in model input data. It specifically assesses the efficacy of Bayesian calibration to enhance the reliability of EnergyPlus model predictions. A Bayesian approach can be used to update uncertain values of parameters, given measured energy-use data, and to quantify the associated uncertainty.We assess the efficacy of Bayesian calibration under a controlled virtual-reality setup, which enables rigorous validation of the accuracy of calibration results in terms of both calibrated parameter values and model predictions. Case studies demonstrate the performance of Bayesian calibration of base models developed from audit data with differing levels of detail in building design, usage, and operation.

97 MATHEMATICS AND COMPUTING↗

Use of carbon electrodes to reduce mobile ion concentration and improve reliability of metal halide perovskite photovoltaics

Ion migration is one of the prime reasons for the rapid degradation of metal halide perovskite solar cells (PSCs), and we report on a method for quantifying mobile ion concentration (No) using a transient dark current measurement. We perform both ex-situ and in-situ measurements on PSCs and study the evolution of No in films and devices under a range of temperatures. We also study the effect of device architecture, top electrode chemistry, and metal halide perovskite composition and dimensionality on No. Two-dimensional perovskites are shown to reduce the ion concentration along with inert C electrodes that do not react with halides by ~99% while also improving mechanical reliability by ~250%. We believe this work can provide design guidelines for the development of stable PSCs through the lens of minimizing mobile ions and their evolution over time under operational conditions.

14 SOLAR ENERGY↗

DOE Commercial Building Energy Asset Rating: Market Research and Program Direction

This paper presents the development of a voluntary energy asset rating system, to evaluate the physical characteristics and as-built energy efficiency of new and existing commercial buildings. The energy asset rating system is intended to enable commercial building stakeholders to directly compare expected as-built energy performance among similar buildings and to analyze the potential for capital improvements to increase energy efficiency cost-effectively. Market research has been performed to understand the market demand and how to communicate energy and cost savings to owners, investors, financiers, and others to overcome market barriers and motivate capital investment in building energy efficiency. The paper discusses the findings of the market research. Building owners are concerned about redundancy, conflicting requirements, and cost. They also pointed out a data gap and desire a rating program that identifies improvement opportunities. A meaningful linkage between the energy asset rating and other rating systems is essential. Based on the findings, criteria for a successful energy asset rating program have been developed to direct the program design, including validity of ratings, actionable, cost effective recommendations, effective quality control, integration with other rating systems, and necessary training and education. In addition to the rating system, an asset rating tool is being developed to reduce cost and increase standardization, allowing for consistent and reliable comparisons among and between buildings. The asset rating tool is the first step in the process by which owners can enter information about their building structure and receive information on the building’s modeled performance and recommended efficiency measures.

commercial building, energy asset rating, market r↗

Using LiF:Mg,Cu,P TLDs to estimate the absorbed dose to water in liquid water around an {sup 192}Ir brachytherapy source

Purpose: The absorbed dose to water is the fundamental reference quantity for brachytherapy treatment planning systems and thermoluminescence dosimeters (TLDs) have been recognized as the most validated detectors for measurement of such a dosimetric descriptor. The detector response in a wide energy spectrum as that of an{sup 192}Ir brachytherapy source as well as the specific measurement medium which surrounds the TLD need to be accounted for when estimating the absorbed dose. This paper develops a methodology based on highly sensitive LiF:Mg,Cu,P TLDs to directly estimate the absorbed dose to water in liquid water around a high dose rate {sup 192}Ir brachytherapy source. Methods: Different experimental designs in liquid water and air were constructed to study the response of LiF:Mg,Cu,P TLDs when irradiated in several standard photon beams of the LNE-LNHB (French national metrology laboratory for ionizing radiation). Measurement strategies and Monte Carlo techniques were developed to calibrate the LiF:Mg,Cu,P detectors in the energy interval characteristic of that found when TLDs are immersed in water around an{sup 192}Ir source. Finally, an experimental system was designed to irradiate TLDs at different angles between 1 and 11 cm away from an {sup 192}Ir source in liquid water. Monte Carlo simulations were performed to correct measured results to provide estimates of the absorbed dose to water in water around the {sup 192}Ir source. Results: The dose response dependence of LiF:Mg,Cu,P TLDs with the linear energy transfer of secondary electrons followed the same variations as those of published results. The calibration strategy which used TLDs in air exposed to a standard N-250 ISO x-ray beam and TLDs in water irradiated with a standard{sup 137}Cs beam provided an estimated mean uncertainty of 2.8% (k = 1) in the TLD calibration coefficient for irradiations by the {sup 192}Ir source in water. The 3D TLD measurements performed in liquid water were obtained with a maximum uncertainty of 11% (k = 1) found at 1 cm from the source. Radial dose values in water were compared against published results of the American Association of Physicists in Medicine and the European Society for Radiotherapy and Oncology and no significant differences (maximum value of 3.1%) were found within uncertainties except for one position at 9 cm (5.8%). At this location the background contribution relative to the TLD signal is relatively small and an unexpected experimental fluctuation in the background estimate may have caused such a large discrepancy. Conclusions: This paper shows that reliable measurements with TLDs in complex energy spectra require a study of the detector dose response with the radiation quality and specific calibration methodologies which model accurately the experimental conditions where the detectors will be used. The authors have developed and studied a method with highly sensitive TLDs and contributed to its validation by comparison with results from the literature. This methodology can be used to provide direct estimates of the absorbed dose rate in water for irradiations with HDR{sup 192}Ir brachytherapy sources.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SiC-CMC-Zircaloy-4 Nuclear Fuel Cladding Performance during 4-Point Tubular Bend Testing

The U.S. Department of Energy Office of Nuclear Energy (DOE NE) established the Light Water Reactor Sustainability (LWRS) program to develop technologies and other solutions to improve the reliability, sustain the safety, and extend the life of current reactors. The Advanced LWR Nuclear Fuel Development Pathway in the LWRS program encompasses strategic research focused on improving reactor core economics and safety margins through the development of an advanced fuel cladding system. Recent investigations of potential options for “accident tolerant” nuclear fuel systems point to the potential benefits of silicon carbide (SiC) cladding. One of the proposed SiC-based fuel cladding designs being investigated incorporates a SiC ceramic matrix composite (CMC) as a structural material supplementing an internal Zircaloy-4 (Zr-4) liner tube, referred to as the hybrid clad design. Characterization of the advanced cladding designs will include a number of out-of-pile (nonnuclear) tests, followed by in-pile irradiation testing of the most promising designs. One of the out-of-pile characterization tests provides measurement of the mechanical properties of the cladding tube using four point bend testing. Although the material properties of the different subsystems (materials) will be determined separately, in this paper we present results of 4-point bending tests performed on fully assembled hybrid cladding tube mock-ups, an assembled Zr-4 cladding tube mock-up as a standard and initial testing results on bare SiC-CMC sleeves to assist in defining design parameters. The hybrid mock-up samples incorporated SiC-CMC sleeves fabricated with 7 polymer impregnation and pyrolysis (PIP) cycles. To provide comparative information; both 1- and 2-ply braided SiC-CMC sleeves were used in this development study. Preliminary stress simulations were performed using the BISON nuclear fuel performance code to show the stress distribution differences for varying lengths between loading points and clad configurations. The 2-ply sleeve samples show a higher bend momentum compared to those of the 1-ply sleeve samples. This is applicable to both the hybrid mock-up and bare SiC-CMC sleeve samples. Comparatively both the 1- and 2-ply hybrid mock-up samples showed a higher bend stiffness and strength compared with the standard Zr-4 mock-up sample. The characterization of the hybrid mock-up samples showed signs of distress and preliminary signs of fraying at the protective Zr-4 sleeve areas for the 1-ply SiC-CMC sleeve. In addition, the microstructure of the SiC matrix near the cracks at the region of highest compressive bending strain shows significant cracking and flaking. The 2-ply SiC-CMC sleeve samples showed a more bonded, cohesive SiC matrix structure. This cracking and fraying causes concern for increased fretting during the actual use of the design. Tomography was proven as a successful tool to identify open porosity during pre-test characterization. Although there is currently insufficient data to make conclusive statements regarding the overall merit of the hybrid cladding design, preliminary characterization of this novel design has been demonstrated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Design and operating characteristic of a vacuum furnace for time-of-flight inelastic neutron scattering measurements

Here, we present the design and operating characteristics of a vacuum furnace used for inelastic neutron scattering experiments on a time-of-flight chopper spectrometer. The device is an actively water cooled radiant heating furnace capable of performing experiments up to 1873 K. Inelastic neutron scattering studies performed with this furnace include studies of phonon dynamics and metallic liquids. We describe the design, control, characterization, and limitations of the equipment. Further, we provide comparisons of the neutron performance of our device with commercially available options. Finally we consider upgrade paths to improve performance and reliability.

47 OTHER INSTRUMENTATION↗

Summary of the Optics, IR, Injection, Operations, Reliability and Instrumentation Working Group

The facilities reported on are all in a fairly mature state of operation, as evidenced by the very detailed studies and correction schemes that all groups are working on. First- and higher-order aberrations are diagnosed and planned to be corrected. Very detailed beam measurements are done to get a global picture of the beam dynamics. More than other facilities the high-luminosity colliders are struggling with experimental background issues, mitigation of which is a permanent challenge. The working group dealt with a very wide rage of practical issues which limit performance of the machines and compared their techniques of operations and their performance. We anticipate this to be a first attempt. In a future workshop in this series, we propose to attempt more fundamental comparisons of each machine, including design parameters. For example, DAΦNE and KEKB employ a finite crossing angle. The minimum value of β* y attainable at KEKB seems to relate to this scheme. Effectiveness of compensation solenoids and turn-by-turn BPMs etc. should be examined in more detail. In the near future, CESR-C and VEPP-2000 will start their operation. We expect to hear important new experiences from these machines; in particular VEPP-2000 will be the first machine to have adopted round beams. At SLAC and KEK, next generation B Factories are being considered. It will be worthwhile to discuss the design issues of these machines based on the experiences of the existing factory machines.

43 PARTICLE ACCELERATORS↗

Validation of (not-historical) large-event near-fault ground-motion simulations for use in civil engineering applications

Ground-motion simulations generated from physics-based wave propagation models are gaining increasing interest in the engineering community for their potential to inform the performance-based design and assessment of infrastructure residing in active seismic areas. A key prerequisite before the ground-motion simulations can be used with confidence for application in engineering domains is their comprehensive and rigorous investigation and validation. This article provides a four-step methodology and acceptance criteria to assess the reliability of simulated ground motions of not historical events, which includes (1) the selection of a population of real records consistent with the simulated scenarios, (2) the comparison of the distribution of Intensity Measures (IMs) from the simulated records, real records, and Ground-Motion Prediction Equations (GMPEs), (3) the comparison of the distribution of simple proxies for building response, and (4) the comparison of the distribution of Engineering Demand Parameters (EDPs) for a realistic model of a structure. Specific focus is laid on near-field ground motions (<10km) from large earthquakes (M w 7), for which the database of real records for potential use in engineering applications is severely limited. The methodology is demonstrated through comparison of (2490) near-field synthetic records with 5 Hz resolution generated from the Pitarka et al (2019) kinematic rupture model with a population of (38) pulse-like near-field real records from multiple events and, when applicable, with NGA-W2 GMPEs. Lastly, the proposed procedure provides an effective method for informing and advancing the science needed to generate realistic ground-motion simulations, and for building confidence in their use in engineering domains.

42 ENGINEERING↗

Performance Assessment of Several Low-Cost Consumer-Grade Analog-to-Digital Conversion Devices

The Oak Ridge National Laboratory (ORNL) has pioneered an approach where low-cost consumer-grade electronics can be used as the basis of a highly reliable data acquisition architecture. One twenty-channel system based on this approach has been operating almost 4 years at ORNL. The architecture allows a mix-and-match level of configurability so the designer can select devices that best match the desired performance trade-offs. The most important device to be selected is the analog-to-digital converter. This paper explores the performance of several candidate audio recording devices that can be used as high-speed analog-to-digital converters for such measurement systems. Various performance metrics are explored including frequency response, noise floor, and synchronous sampling. Sample rates as high as 192 KHz are supported with 16 and 24-bit resolution. While most of the devices are dual-channel, there are multi-channel devices now available that will allow modal type of synchronous sampling. One such device was tested and is discussed is this paper.

Wetherington Jr, G↗