Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance portability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Portable Parallel Algorithms and Frameworks for Exascale Graph Analytics

Graphs (or networks) are a tool used to model the interactions among various entities. Efficiently processing large graphs has recently attracted significant attention due to the applications of graphs in various domains, such as biology, chemistry, and cyber-security. Analyzing the structure and properties of these graphs is an important component of many scientific computing pipelines. With the explosion in the volume of data, graphs have become very large and can contain hundreds of billions of vertices and trillions of edges. Therefore, it is crucial to develop high-performance methods to enable graph analysis to be done quickly and energy-efficiently. Furthermore, these solutions should be highly parallel in order to take advantage of modern parallel machines. However, designing efficient solutions is not enough. With the wide variety of computing environments available, each with different programmability and performance characteristics, it is necessary to develop solutions that are portable in terms of both performance (i.e., provide theoretical guarantees) and programmability (i.e., provide high level abstractions).

97 MATHEMATICS AND COMPUTING↗

Assessing the Added Value of Miniature X-Ray in the Setting of Portable Ultrasound in Spaceflight

INTRODUCTION: Point-of-care ultrasound (POCUS) has become the standard of care for imaging diagnosis and management in low-Earth Orbit (LEO) spaceflight and it has long been hypothesized that POCUS will also be the standard of care for exploration spaceflight. However, like the trajectory for which ultrasound became more portable and user-friendly, the mass, volume, and power requirements of radiography devices for both diagnostic and therapeutic applications have also been dramatically reduced. This study seeks to determine the clinical utility and added value of miniature x-ray (XR) for the diagnosis and management of each of the 119 conditions within NASA Exploration Medical Capability’s IMPACT Condition List (ICL) given that the medical system is presumed to already be carrying a handheld portable POCUS device. METHODS: For each condition, a team of reviewers performed a rapid systematic literature review seeking sensitivity and specificity data for both handheld portable ultrasound and miniature XR. When there was a paucity of data, subject matter expertise and clinical experience was added to semi-quantitatively score the added value of miniature XR, given an US was already available for both diagnosis and management. Diagnostic utility of a modality for a condition was evaluated in the setting of both the best- and worst-case scenario definitions included and defined by the ICL. Evidence tracing and quality of evidence scores were also recorded. RESULTS/DISCUSSION: Conditions for which it was determined that miniature XR added diagnostic or therapeutic value are provided in this presentation. Previously presented work by our team has demonstrated that XR provides diagnostic and management capabilities that are hypothesized to complement or surpass ultrasound for over one-third of medical conditions that may arise during exploration spaceflight (i.e., diagnosis of injuries to the axial skeleton, teeth, and lungs as well as management of orthopedic reductions, endotracheal tube placement, and drain placement confirmation). In the setting of known inclusion of a handheld portable POCUS device, there remains significant added value of portable miniature XR. Whether or not this added clinical benefit is worth the mass, volume, and power requirements of the radiography system remains yet unknown and is the focus of future work. LEARNING OBJECTIVES: 1) Understand the value of ultrasound and radiography in the diagnosis and management of medical comorbidities that may arise in exploration spaceflight; 2) Understand the medical conditions of highest concern on exploration class missions for which miniature x-ray may provide added value to portable ultrasound.

J G Steller↗

Assessing the Added Value of Miniature X-Ray in the Setting of US in Spaceflight

INTRODUCTION: Point-of-care ultrasound (POCUS) has become the standard of care for imaging diagnosis and management in lowEarth Orbit (LEO) spaceflight and it has long been hypothesized that POCUS will also be the standard of care for exploration spaceflight. However, like the trajectory for which ultrasound became more portable and user-friendly, the mass, volume, and power requirements of radiography devices for both diagnostic and therapeutic applications have also been dramatically reduced. This study seeks to determine the clinical utility and added value of miniature x-ray (XR) for the diagnosis and management of each of the 119 conditions within NASA Exploration Medical Capability’s IMPACT Condition List (ICL) given that the medical system is presumed to already be carrying a handheld portable POCUS device. METHODS: For each condition, a team of reviewers performed a rapid systematic literature review seeking sensitivity and specificity data for both handheld portable ultrasound and miniature XR. When there was a paucity of data, subject matter expertise and clinical experience was added to semi-quantitatively score the added value of miniature XR, given an US was already available for both diagnosis and management. Diagnostic utility of a modality for a condition was evaluated in the setting of both the best- and worst-case scenario definitions included and defined by the ICL. Evidence tracing and quality of evidence scores were also recorded. RESULTS/DISCUSSION: Conditions for which it was determined that miniature XR added diagnostic or therapeutic value are provided in this presentation. Previously presented work by our team has demonstrated that XR provides diagnostic and management capabilities that are hypothesized to complement or surpass ultrasound for over one-third of medical conditions that may arise during exploration spaceflight (i.e., diagnosis of injuries to the axial skeleton, teeth, and lungs as well as management of orthopedic reductions, endotracheal tube placement, and drain placement confirmation). In the setting of known inclusion of a handheld portable POCUS device, there remains significant added value of portable miniature XR. Whether or not this added clinical benefit is worth the mass, volume, and power requirements of the radiography system remains yet unknown and is the focus of future work. LEARNING OBJECTIVES: 1) Understand the value of ultrasound and radiography in the diagnosis and management of medical comorbidities that may arise in exploration spaceflight; 2) Understand the medical conditions of highest concern on exploration class missions for which miniature x-ray may provide added value to portable ultrasound.

Jon Steller↗

A real-time diagnostic and performance monitor for UNIX

There are now over one million UNIX sites and the pace at which new installations are added is steadily increasing. Along with this increase, comes a need to develop simple efficient, effective and adaptable ways of simultaneously collecting real-time diagnostic and performance data. This need exists because distributed systems can give rise to complex failure situations that are often un-identifiable with single-machine diagnostic software. The simultaneous collection of error and performance data is also important for research in failure prediction and error/performance studies. This paper introduces a portable method to concurrently collect real-time diagnostic and performance data on a distributed UNIX system. The combined diagnostic/performance data collection is implemented on a distributed multi-computer system using SUN4's as servers. The approach uses existing UNIX system facilities to gather system dependability information such as error and crash reports. In addition, performance data such as CPU utilization, disk usage, I/O transfer rate and network contention is also collected. In the future, the collected data will be used to identify dependability bottlenecks and to analyze the impact of failures on system performance.

Dong, Hongchao↗

RF Exposure Analysis for Multiple Wi-Fi Devices In Enclosed Environment

Wi-Fi devices operated inside a metallic enclosure have been investigation in the recent years. A motivation for this study is to investigate wave propagation inside an enclosed environment such as elevator, car, aircraft, and spacecraft. There are performances and safety concerned that when the RF transmitters are used in the metallic enclosed environments. In this paper, the field distributions inside a confined room were investigated with multiple portable Wi-Fi devices. Computer simulations were performed using the rigorous computational electromagnetics (CEM). The method of moments (MoM) was used to model the mutual coupling among antennas. The geometrical theory of diffraction (GTD) was applied for the multiple reflections off the ground and walls. The prediction of the field distribution inside such environment is useful for the planning and deployment of a wireless radio and sensor system. Factors that affect the field strengths and distributions of radio waves in confined space were analyzed. The results could be used to evaluate the RF exposure safety in confined environment. By comparing the field distributions for various scenarios, it was observed that the Wi-Fi device counts, spacing and relative locations in the room are important factors in such environments. The RF Keep Out Zone (KOZ), where the electric field strengths exceed the permissible RF exposure limit, could be used to assess the RF human exposure compliance. As shown in this study, it s possible to maximize or minimize field intensity in specific area by arranging the Wi-Fi devices as a function of the relative location and spacing in a calculated manner.

Hwu, Shian U.↗

Advanced Ultrasonic Diagnosis of Extremity Trauma: The Faster Exam

Ultrasound is of prO)len accuracy in abdominal and thoracic trauma and may be useful to diagnose extremity injury in situations where radiography is not available such as military and space applications. We prospectively evaluated the utility of extremity , ultrasound performed by trained, non-physician personnel in patients with extremity trauma, to simulate remote aerospace or military applications . Methods: Patients with extremity trauma were identified by history, physical examination, and radiographic studies. Ultrasound examination was performed bilaterally by nonphysician personnel with a portable ultrasound device using a 10-5 MHz linear probe, Images were video-recorded for later analysis against radiography by Fisher's exact test. The average time of examination was 4 minutes. Ultrasound accurately diagnosed extremity, injury in 94% of patients with no false positive exams; accuracy was greater in mid-shaft locations and least in the metacarpa/metatarsals. Soft tissue/tendon injury was readily visualized . Extremity ultrasound can be performed quickly and accurately by nonphysician personnel with excellent accuracy. Blinded verification of the utility of ultrasound in patients with extremity injury should be done to determine if Extremity and Respiratory evaluation should be added to the FAST examination (the FASTER exam) and verify the technique in remote locations such as military and aerospace applications.

Dulchavsky, S. A.↗

The Reusable Handheld Electrolyte and Lab Technology for Humans (rHEALTH) Sensor

The DNA Medicine Institute has produced a reusable microfluidic device that performs rapid, low-cost cell counts and measurements of electrolytes, proteins, and other biomarkers. The rHEALTH sensor is compact and portable, and it employs cutting-edge fluorescence detection optics, innovative microfluidics, and nanostrip reagents to perform a suite of hematology, chemistry, and biomarker assays from a single drop of blood. A handful of current portable POC devices provide generalized blood analysis, but they perform only a few tests at a time. These devices also rely on disposable components and depend on diverse detection technologies to complete routine tests-all ill-suited for space travelers on extended missions. In contrast, the rHEALTH sensor integrates sample introduction, processing, and detection with a compact, resource-conscious, and efficient design. Developed to monitor astronaut health on the International Space Station and during long-term space flight, this microscale lab analysis tool also has terrestrial applications that include POC diagnostics conducted at a patient's bedside, in a doctor's office, and in a hospital.

Chan, Eugene↗

Fabrication of metal-organic framework thin films for luminescent sensing applications

Metal−organic frameworks (MOFs) have emerged as an exciting material class due to their nearly infinite design space: an inexhaustible combination of metal centers, organic linkers, and reaction conditions may be leveraged to obtained desired optical, physical, and chemical properties. This rich synthetic diversity enables properties such as pore dimensions and functionality to be rationally tailored for highly selective and sensitive detection of target analytes. Luminescent MOF-based sensors in particular offer advantages including low cost, portability, and ease-of-use. Often, performance is maximized by utilizing the luminescent MOF in thin film form, for example by integrating the film onto an optical fiber, yet the synthesis of high-quality MOF thin films often requires tedious, expensive, and/or slow approaches. Here, we demonstrate a rapid, simple strategy for growing copper MOFs using metal oxide templates; the concept is first demonstrated with a well-studied system, copper-1,3,5-benznetricarboxylate (Cu-BTC). Variables such as the choice of solvent, pH, and the choice of the copper salt anion all govern thin film quality. We then extend this method to synthesize a solvent and metal-responsive copper MOF that is particularly effective at detecting aluminum, an economically critical metal, at trace concentrations using a fully portable luminescence spectrometer. Taken together, this work demonstrates a convenient, versatile, and sustainable method for developing high quality MOF thin film-based optical sensors.

Crawford, Scott↗

MPF: A portable message passing facility for shared memory multiprocessors

The design, implementation, and performance evaluation of a message passing facility (MPF) for shared memory multiprocessors are presented. The MPF is based on a message passing model conceptually similar to conversations. Participants (parallel processors) can enter or leave a conversation at any time. The message passing primitives for this model are implemented as a portable library of C function calls. The MPF is currently operational on a Sequent Balance 21000, and several parallel applications were developed and tested. Several simple benchmark programs are presented to establish interprocess communication performance for common patterns of interprocess communication. Finally, performance figures are presented for two parallel applications, linear systems solution, and iterative solution of partial differential equations.

Malony, Allen D.↗

Eddy current X-Y scanner system

The Nondestructive Evaluation Branch of the Materials and Processes Laboratory became aware of a need for a miniature, portable X-Y scanner capable of performing eddy current or other nondestructive testing scanning operations such as ultrasonic, or small areas of flat plate. The technical description and operational theory of the X-Y scanner system designed and built to fulfill this need are covered. The scanner was given limited testing and performs according to its design intent, which is to scan flat plate areas of approximately 412 sq cm (64 sq in) during each complete cycle of scanning.

Kurtz, G. W.↗

Recent Advances in High-Performance Direct Methanol Fuel Cells

Direct methanol fuel cells for portable power applications have been advanced significantly under DARPA- and ARO-sponsored programs over the last five years. A liquid-feed, direct methanol fuel cell developed under these programs, employs a proton exchange membrane as electrolyte and operates on aqueous solutions of methanol with air or oxygen as the oxidant.

fuel cells methanol methanol fuel cells DARPA ARO↗

High power, gel polymer lithium-ion cells with improved low temperature performance for NASA and DoD applications

Both NASA and the U.S. Army have interest in developing secondary energy storage devices that are capable of meeting the demanding performance requirements of aerospace and man-portable applications. In order to meet these demanding requirements, gel-polymer electrolyte-based lithium-ion cells are being actively considered, due to their promise of providing high specific energy and enhanced safety aspects.

high power li-ion batteries↗

Fault Detection, Isolation and Recovery (FDIR) Portable Liquid Oxygen Hardware Demonstrator

The Fault Detection, Isolation and Recovery (FDIR) hardware demonstration will highlight the effort being conducted by Constellation's Ground Operations (GO) to provide the Launch Control System (LCS) with system-level health management during vehicle processing and countdown activities. A proof-of-concept demonstration of the FDIR prototype established the capability of the software to provide real-time fault detection and isolation using generated Liquid Hydrogen data. The FDIR portable testbed unit (presented here) aims to enhance FDIR by providing a dynamic simulation of Constellation subsystems that feed the FDIR software live data based on Liquid Oxygen system properties. The LO2 cryogenic ground system has key properties that are analogous to the properties of an electronic circuit. The LO2 system is modeled using electrical components and an equivalent circuit is designed on a printed circuit board to simulate the live data. The portable testbed is also be equipped with data acquisition and communication hardware to relay the measurements to the FDIR application running on a PC. This portable testbed is an ideal capability to perform FDIR software testing, troubleshooting, training among others.

Oostdyk, Rebecca L.↗

Thermal Analysis of Compressible CO2 Flow for Major Equipment of Fire Detection System

A thermal analysis of the compressible CO2 flow for the Portable Fire Extinguisher (PFE) system has been performed. The purpose of this analysis is to determine the discharged CO2 mass from the PFE tank through the Temporary Sleep Station (TeSS) nozzle in reflecting to the latest design of the extended nozzle, and to evaluate the thermal issues associated to the latest nozzle configuration. A SINDA/FLUINT model has been developed for this analysis. The model includes the PFE tank and the TeSS nozzle, and both have initial temperature of 72 of. In order to investigate the thermal effect on the nozzle due to discharging C02, the PFE TeSS nozzle pipe has been divided into three segments. This model also includes heat transfer predictions for PFE tank inner and outer wall surfaces. The simulation results show that the CO2 discharge rates have fulfilled the minimum flow requirements that the PFE system discharges 3.0 Ibm CO2 in 10 seconds and 5.5 Ibm of CO2 in 45 seconds during its operation. At 45 seconds, the PFE tank wall temperature is 63 OF, and the TeSS nozzle cover wall temperatures for the three segments are 47 OF, 53 OF and 37 OF, respectively. Thermal insulation for personal protection is used for the first two segments of the TeSS nozzle. The simulation results also indicate that at 50 seconds, the remaining CO2 in the tank may be near the triple point (gas, liquid and solid) state and, therefore, restricts the flow.

Zhang, Michael Y.↗

Thermal Analysis of Compressible CO2 Flow for PFE TeSS Nozzle of Fire Detection System

A thermal analysis of the compressible CO2 flow for the Portable Fire Extinguisher (PFE) system has been performed. A SINDA/FLUINT model has been developed for this analysis. The model includes the PFE tank and the TeSS nozzle, and both have initial temperature of 72 F. In order to investigate the thermal effect on the nozzle due to discharging CO2, the PFE TeSS nozzle pipe has been divided into three segments. This model also includes heat transfer predictions for PFE tank inner and outer wall surfaces. The simulation results show that the CO2 discharge rates have fulfilled the minimum flow requirements that the PFE system discharges 3.0 Ibm CO2 in 10 seconds and 5.5 Ibm of CO2 in 45 seconds during its operation. At 45 seconds, the PFE tank wall temperature is 63 F, and the TeSS nozzle cover wall temperatures for the three segments are 47 F, 53 F and 37 F, respectively. Thermal insulation for personal protection is used for the first two segments of the TeSS nozzle. The simulation results also indicate that at 50 seconds, the remaining CO2 in the tank may be near the triple point (gas, liquid and solid) state and, therefore, restricts the flow.

Zhang, Y. Michael↗

Development Specification for the Feedwater Supply Assembly (FSA), FSA-431 with Integrated Auxiliary Feedwater Supply Assembly (AFSA), FSA-531

The FSA with Integrated Aux FSA Specification establishes the requirements for design, performance, and testing of the FSA-431/FSA-531 assembly in compliance with CTSD-ADV-780, Development Specification for the Advanced EMU (AEMU) Portable Life Support System (PLSS). This section contains the technical design and performance requirements for the integrated assembly of the Feedwater Supply Assembly and Auxiliary Feedwater Supply Assembly for the Advanced EVA Development Portable Life Support Subsystem (PLSS).

Anchondo, Ian↗

Automatic Generation of Directive-Based Parallel Programs for Shared Memory Parallel Systems

The shared-memory programming model is a very effective way to achieve parallelism on shared memory parallel computers. As great progress was made in hardware and software technologies, performance of parallel programs with compiler directives has demonstrated large improvement. The introduction of OpenMP directives, the industrial standard for shared-memory programming, has minimized the issue of portability. Due to its ease of programming and its good performance, the technique has become very popular. In this study, we have extended CAPTools, a computer-aided parallelization toolkit, to automatically generate directive-based, OpenMP, parallel programs. We outline techniques used in the implementation of the tool and present test results on the NAS parallel benchmarks and ARC3D, a CFD application. This work demonstrates the great potential of using computer-aided tools to quickly port parallel programs and also achieve good performance.

Jin, Hao-Qiang↗

Hardware in the Loop Testing of an Iodine-Fed Hall Thruster

CUBESATS are relatively new spacecraft platforms that are typically deployed from a launch vehicle as a secondary payload,1 providing low-cost access to space for a wide range of end-users. These satellites are comprised of building blocks having dimensions of 10x10x10 cm cu and a mass of 1.33 kg (a 1-U size). While providing low-cost access to space, a major operational limitation is the lack of a propulsion system that can fit within a CubeSat and is capable of executing high delta v maneuvers. This makes it difficult to use CubeSats on missions requiring certain types of maneuvers (i.e. formation flying, spacecraft rendezvous). Recently, work has been performed investigating the use of iodine as a propellant for Hall-effect thrusters (HETs) 2 that could subsequently be used to provide a high specific impulse path to CubeSat propulsion. Iodine stores as a dense solid at very low pressures, making it acceptable as a propellant on a secondary payload. It has exceptionally high ρIsp (density times specific impulse), making it an enabling technology for small satellite near-term applications and providing the potential for systems-level advantages over mid-term high power electric propulsion options. Iodine flow can also be thermally regulated, subliming at relatively low temperature ( less than100 C) to yield I2 vapor at or below 50 torr. At low power, the measured performance of an iodine-fed HET is very similar to that of a state-of-the-art xenon-fed thruster. Just as importantly, the current-voltage discharge characteristics of low power iodine-fed and xenon-fed thrusters are remarkably similar, potentially reducing development and qualifications costs by making it possible to use an already-qualified xenon-HET PPU in an iodine-fed system. Finally, a cold surface can be installed in a vacuum test chamber on which expended iodine propellant can deposit. In addition, the temperature doesn't have to be extremely cold to maintain a low vapor pressure in the vacuum chamber (it is under 10(exp -6) torr at -75 C), making it possible to 'cryopump' the propellant with lower-cost recirculating refrigerant-based systems as opposed to using liquid nitrogen or low temperature gaseous helium cryopanels. In the present paper, we describe testing performed using an iodine-fed 200 W Hall thruster mounted to a thrust stand and operated in conjunction with MSFCs Small Projects Rapid Integration and Test Environment (SPRITE) Portable Hardware In the Loop (PHIL) hardware. This work is performed in support of the iodine satellite (iSAT) project, which aims to fly a 200-W iodine-fed thruster on a 12-U CubeSat. The SPRITE PHIL hardware allows a given vehicle to do a checkout of its avionics algorithm by allowing it to monitor and feed data to simulated sensors and effectors in a digital environment. These data are then used to determine the attitude of the vehicle and a separate computer is used to interpret the data set and visualize it using a 3D graphical interface. The PHIL hardware allows the testing of the vehicles bus by providing 'real' hardware interfaces (in the case of this test a real RS422 bus) and specific components can be modeled to show their interactions with the avionics algorithm (e.g. a thruster model). For the iSAT project the PHIL is used to visualize the operating cycle of the thruster and the subsequent effect this thrusting has on the attitude of the satellite over a given period of time. The test is controlled using software running on an Andrews Space Cortex 160 flight computer. This computer is the current baseline for a full iSAT mission. While the test could be conducted with a lab computer and software, the team chose to exercise the propulsion system with a representative CubeSat-class computer. For purposes of this test, the "flight" software monitored the propulsion and PPU systems, controlled operation of the thruster, and provided thruster state data to the PHIL simulation. Commands to operate the thruster were initiated from an operator's workstation outside the vacuum chamber and passed through the Cortex 160 to exercise portions of the flight avionics. Two custom-designed pieces of electronics hardware have been designed to operate the propellant feed system. One piece of hardware is an auxiliary board that controls a latch valve, proportional flow control valves (PFCVs) and valve heaters as well as measuring pressures, temperatures and PFCV feedback voltage. An onboard FPGA provides a serial link for issuing commands and manages all lower level input-output functions. The other piece of hardware is a power distribution board, which accepts a standard bus voltage input and converts this voltage into all the different current-voltage types required to operate the auxiliary board. These electronics boards are located in the vacuum chamber near the thruster, exposing this hardware to both the vacuum and plasma environments they would encounter during a mission, with these components communicating to the flight computer through an RS-422 interface. The auxiliary board FPGA provides a 28V MOSFET switch circuit with a 20ms pulse to open or close the iodine propellant feed system latch valve. The FPGA provides a pulse width modulation (PWM) signal to a DC/DC boost converter to produce the 12-120V needed for control of the proportional flow control valve. There are eight MOSFET-switched heating circuits in the system. Heaters are 28V and located in the latch valve, PFCV, propellant tank and propellant feed lines. Both the latch valve and PFCV have thermistors built into them for temperature monitoring. There are also seven resistance temperature device (RTD) circuits on the auxiliary board that can be used to measure the propellant tank and feedline temperatures. The signals are conditioned and sent to an analog to digital converter (ADC), which is directly commanded and controlled by the FPGA.

Polzin, Kurt A.↗