Search NASA⌕ Search

SEARCH · Search NASA

Results for “Phase Retrieval”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

SHARP: a distributed GPU-based ptychographic solver

Ever brighter light sources, fast parallel detectors and advances in phase retrieval methods have made ptychography a practical and popular imaging technique. Compared to previous techniques, ptychography provides superior robustness and resolution at the expense of more advanced and time-consuming data analysis. Therefore, by taking advantage of massively parallel architectures, high-throughput processing can expedite this analysis and provide microscopists with immediate feedback. These advances allow real-time imaging at wavelength-limited resolution, coupled with a large field of view. This article describes a set of algorithmic and computational methodologies used at the Advanced Light Source and US Department of Energy light sources. These are packaged as a CUDA-based software environment named SHARP, aimed at providing state-of-the-art high-throughput ptychography reconstructions for the coming era of diffraction-limited light sources.

47 OTHER INSTRUMENTATION↗

$Z$-Pinch Interferometry Analysis With the Fourier-Based TNT Code

Here, we present the analysis of interferometry diagnostics with the user-friendly Talbot Numerical Tool (TNT), a Fourier-based postprocessing code that enables real-time assessment of plasma systems. TNT performance was explored with visible and infrared interferometry in pulsed-power-driven Z -pinch configurations to expand its capabilities beyond Talbot X-ray interferometry in the high-intensity laser environment. TNT enabled accurate electron density characterization of magnetically driven plasma flows and shocks through phase-retrieval methods that did not require data modification or masking. TNT demonstrated enhanced resolution, detecting below 4 % fringe shift, which corresponds to 8.7 × 10 15 cm –2 within 28 μ m, approaching the laser probing system limit. TNT was tested against a well-known interferometry analysis software, delivering an average resolving power nearly ten times better (~28 μ m versus ~ 210 μ m) when resolving plasma ablation features. TNT demonstrated higher sensitivity when probing sharp electron density gradients in supersonic shocks. A maximum electron areal density of 4.1 × 10 17 cm –2 was measured in the shocked plasma region, and a minimum electron density detection of ~ 1.0 × 10 15 cm –2 was achieved. When probing colliding plasma flows, the calculations of the effective adiabatic index and the associated errors were improved from γ* = 2.6 ± 1.6 – 1.4 ± 0.2 with TNT postprocessing, contributing valuable data for the interpretation of radiative transport. Additional applications of TNT in the characterization of pulsed-power plasmas and beyond are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Phase measurement in temporal speckle pattern interferometry signals presenting low-modulated regions by means of the bidimensional empirical mode decomposition

We propose a phase measurement technique to retrieve optical phase distributions coded in noisy temporal speckle pattern interferometry signals presenting regions of adjacent low-modulated pixels, which is based on the bidimensional empirical mode decomposition and the Hilbert transform. It is shown that this approach can effectively remove noise and minimize the influence of large sets of adjacent nonmodulated pixels located in the time series of speckle interferograms. The performance of the phase retrieval approach is analyzed using computer-simulated speckle interferograms modulated with a temporal carrier. The results are also compared with those given by a technique based on the one-dimensional empirical mode decomposition. The advantages and limitations of the proposed approach are finally discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hollow Ptychography: Toward Simultaneous 4D Scanning Transmission Electron Microscopy and Electron Energy Loss Spectroscopy

With the recent development of high-acquisition-speed pixelated detectors, 4D scanning transmission electron microscopy (4D-STEM) is becoming routinely available in high-resolution electron microscopy. 4D-STEM acts as a “universal” method that provides local information on materials that is challenging to extract from bulk techniques. It extends conventional STEM imaging to include super-resolution techniques and to provide quantitative phase-based information, such as differential phase contrast, ptychography, or Bloch wave phase retrieval. However, an important missing factor is the chemical and bonding information provided by electron energy loss spectroscopy (EELS). 4D-STEM and EELS cannot currently be acquired simultaneously due to the overlapping geometry of the detectors. Here, the feasibility of modifying the detector geometry to overcome this challenge for bulk specimens is demonstrated, and the use of a partial or defective detector for ptycholgaphic structural imaging is explored. Here, results show that structural information beyond the diffraction-limit and chemical information from the material can be extracted together, resulting in simultaneous multi-modal measurements, adding the additional dimensions of spectral information to 4D datasets.

4D-scanning transmitting electron microscopy (STEM↗

Review of phase measuring deflectometry

As a low cost, full-field three-dimensional shape measurement technique with high dynamic range, Phase Measuring Deflectometry (PMD) has been studied and improved to be a simple and effective manner to inspect specular reflecting surfaces. In this review, the fundamental principle and the basic concepts of PMD technique are introduced and followed by a brief overview of its key developments since it was first proposed. In addition, the similarities and differences compared with other related techniques are discussed to highlight the distinguishing features of the PMD technique. In conclusion, we will address the major challenges, the existing solutions and the remaining limitations in this technique to provide some suggestions for potential future investigations.

42 ENGINEERING↗

Measuring Three-Dimensional Strain and Structural Defects in a Single InGaAs Nanowire Using Coherent X-ray Multiangle Bragg Projection Ptychography

III - As nanowires are candidates for near-infrared light emitters and detectors that can be directly integrated onto silicon. However, nanoscale to microscale variations in structure, composition, and strain within a given nanowire, as well as variations between nanowires, pose challenges to correlating microstructure with device performance. In this work, we utilize coherent nanofocused X-rays to characterize stacking defects and strain in a single InGaAs nanowire supported on Si. By reconstructing diffraction patterns from the 2110 Bragg peak, we show that the lattice orientation varies along the length of the wire, while the strain field along the cross-section is largely unaffected, leaving the band structure unperturbed. Diffraction patterns from the 0110 Bragg peak are reproducibly reconstructed to create three-dimensional images of stacking defects and associated lattice strains, revealing sharp planar boundaries between different crystal phases of wurtzite (WZ) structure that contribute to charge carrier scattering. Phase retrieval is made possible by developing multiangle Bragg projection ptychography (maBPP) to accommodate coherent nanodiffraction patterns measured at arbitrary overlapping positions at multiple angles about a Bragg peak, eliminating the need for scan registration at different angles. The penetrating nature of X-ray radiation, together with the relaxed constraints of maBPP, will enable the in operando imaging of nanowire devices.

36 MATERIALS SCIENCE↗

Observation of stable Néel skyrmions in cobalt/palladium multilayers with Lorentz transmission electron microscopy

Néel skyrmions are of high interest due to their potential applications in a variety of spintronic devices, currently accessible in ultrathin heavy metal/ferromagnetic bilayers and multilayers with a strong Dzyaloshinskii–Moriya interaction. Here in this paper we report on the direct imaging of chiral spin structures including skyrmions in an exchange-coupled cobalt/palladium multilayer at room temperature with Lorentz transmission electron microscopy, a high-resolution technique previously suggested to exhibit no Néel skyrmion contrast. Phase retrieval methods allow us to map the internal spin structure of the skyrmion core, identifying a 25 nm central region of uniform magnetization followed by a larger region characterized by rotation from in- to out-of-plane. The formation and resolution of the internal spin structure of room temperature skyrmions without a stabilizing out-of-plane field in thick magnetic multilayers opens up a new set of tools and materials to study the physics and device applications associated with chiral ordering and skyrmions.

36 MATERIALS SCIENCE↗

High-resolution three-dimensional structural microscopy by single-angle Bragg ptychography

Coherent X-ray microscopy by phase retrieval of Bragg diffraction intensities enables lattice distortions within a crystal to be imaged at nanometre-scale spatial resolutions in three dimensions. While this capability can be used to resolve structure–property relationships at the nanoscale under working conditions, strict data measurement requirements can limit the application of current approaches. Here, in this work, we introduce an efficient method of imaging three-dimensional (3D) nanoscale lattice behaviour and strain fields in crystalline materials with a methodology that we call 3D Bragg projection ptychography (3DBPP). This method enables 3D image reconstruction of a crystal volume from a series of two-dimensional X-ray Bragg coherent intensity diffraction patterns measured at a single incident beam angle. Structural information about the sample is encoded along two reciprocal-space directions normal to the Bragg diffracted exit beam, and along the third dimension in real space by the scanning beam. Finally, we present our approach with an analytical derivation, a numerical demonstration, and an experimental reconstruction of lattice distortions in a component of a nanoelectronic prototype device.

36 MATERIALS SCIENCE↗

Sparse recovery of undersampled intensity patterns for coherent diffraction imaging at high X-ray energies

Coherent X-ray photons with energies higher than 50 keV offer new possibilities for imaging nanoscale lattice distortions in bulk crystalline materials using Bragg peak phase retrieval methods. However, the compression of reciprocal space at high energies typically results in poorly resolved fringes on an area detector, rendering the diffraction data unsuitable for the three-dimensional reconstruction of compact crystals. To address this problem, we propose a method by which to recover fine fringe detail in the scattered intensity. This recovery is achieved in two steps: multiple undersampled measurements are made by in-plane sub-pixel motion of the area detector, then this data set is passed to a sparsity-based numerical solver that recovers fringe detail suitable for standard Bragg coherent diffraction imaging (BCDI) reconstruction methods of compact single crystals. The key insight of this paper is that sparsity in a BCDI data set can be enforced by recognising that the signal in the detector, though poorly resolved, is band-limited. This requires fewer in-plane detector translations for complete signal recovery, while adhering to information theory limits. Lastly, we use simulated BCDI data sets to demonstrate the approach, outline our sparse recovery strategy, and comment on future opportunities.

36 MATERIALS SCIENCE↗

Impact and mitigation of angular uncertainties in Bragg coherent x-ray diffraction imaging

Bragg coherent diffraction imaging (BCDI) is a powerful technique to explore the local strain state and morphology of microscale crystals. The method can potentially reach nanometer-scale spatial resolution thanks to the advances in synchrotron design that dramatically increase coherent flux. However, there are experimental bottlenecks that may limit the image reconstruction quality from future high signal-to-noise ratio measurements. In this work we show that angular uncertainty of the sample orientation with respect to a fixed incoming beam is one example of such a factor, and we present a method to mitigate the resulting artifacts. On the basis of an alternative formulation of the forward problem, we design a phase retrieval algorithm which enables the simultaneous reconstruction of the object and determination of the exact angular position corresponding to each diffraction pattern in the data set. We have tested the algorithm performance on simulated data for different degrees of angular uncertainty and signal-to-noise ratio.

36 MATERIALS SCIENCE↗

A comprehensive simulation framework for imaging single particles and biomolecules at the European X-ray Free-Electron Laser

The advent of newer, brighter, and more coherent X-ray sources, such as X-ray Free-Electron Lasers (XFELs), represents a tremendous growth in the potential to apply coherent X-rays to determine the structure of materials from the micron-scale down to the Angstrom-scale. There is a significant need for a multi-physics simulation framework to perform source-to-detector simulations for a single particle imaging experiment, including (i) the multidimensional simulation of the X-ray source; (ii) simulation of the wave-optics propagation of the coherent XFEL beams; (iii) atomistic modelling of photon-material interactions; (iv) simulation of the time-dependent diffraction process, including incoherent scattering; (v) assembling noisy and incomplete diffraction intensities into a three-dimensional data set using the Expansion-Maximisation-Compression (EMC) algorithm and (vi) phase retrieval to obtain structural information. Furthermore, we demonstrate the framework by simulating a single-particle experiment for a nitrogenase iron protein using parameters of the SPB/SFX instrument of the European XFEL. This exercise demonstrably yields interpretable consequences for structure determination that are crucial yet currently unavailable for experiment design.

42 ENGINEERING↗

Surface x-ray diffraction of complex metal oxide surfaces and interfaces--a new era

The availability of high-brilliance hard x-ray synchrotron radiation and the advent of novel photon counting area detectors have brought surface x-ray diffraction (SXRD) into a new era. It is now possible to record large numbers of structure factors with much improved reliability within reasonable beamtime durations. As a result, structural determination of the surfaces and interfaces of complex crystallographic systems and heterostructures has now become feasible, especially in conjunction with phase-retrieval methods. It is thereby hoped that detailed structural information will shed light on the unusual physical properties of these systems. Complex metal oxide systems investigated at the Materials Science beamline of the Swiss Light Source, including the surface of SrTiO{sub 3}, the interface between LaAlO{sub 3} and SrTiO{sub 3}, and the structure of YBa{sub 2}Cu{sub 3}O{sub 7} grown on NdGaO{sub 3}, SrTiO{sub 3}, and (LaSr)(AlTa)O{sub 3} will be presented as examples of what is now possible using SXRD.

36 MATERIALS SCIENCE↗

Phase-contrast and holographic computed laminography

In-line phase contrast is combined with laminography to image in three dimensions regions of interest in laterally extended flat specimens of weak absorption contrast. The principle of the method and a theoretical description of the imaging process are outlined. The present instrumental implementation enables reconstructing nondestructively the internal structure at different lateral specimen positions with micron resolution. The feasibility and application potential are demonstrated for both phase-contrast and holographic (i.e., using phase retrieval) laminography by the three-dimensional imaging of fuel-cell diffusion layers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Coherent X-ray Diffraction Imaging of Zeolite Microcrystals

We measured coherent x-ray diffraction (CXD), an emerging technique to obtain three-dimensional internal and external images of crystals, on ZSM-5 zeolite microcrystals to get internal density distribution and to map deformation field of strain. The experiments were performed at the beamline 34-ID-C in Advanced Photon Source at Argonne National Laboratory in the US. The CXD patterns of ZSM-5 zeolite microcrystals with sizes of 2 {mu}m by monochromatic coherent x-rays with energy of 9 keV were obtained under continuously surrounding and Bragg conditions as a function of temperature. The oversampled diffraction patterns are inverted to obtain three-dimensional images of the shapes and internal strain fields of zeolite microcrystals using phase retrieval algorithms of error reduction and a hybrid input-output method. The internal density and strain distribution as a function of temperature are discussed.

36 MATERIALS SCIENCE↗

X-ray phase-contrast imaging with an Inverse Compton Scattering source

Single-shot in-line phase-contrast imaging with the Inverse Compton Scattering X-ray source available at ATF (Accelerator Test Facility) at Brookhaven National Laboratory is experimentally demonstrated. Phase-contrast images of polymer wires are obtained with a single X-ray pulse whose time length is about 1 picosecond. The edge-enhancement effect is clearly visible in the images and simulations show a quantitative agreement with experimental data. A phase-retrieval step in the image processing leads to a accurate estimation of the projected thickness of our samples. Finally, a single-shot image of a wasp is presented as an example of a biological sample.

07 ISOTOPE AND RADIATION SOURCES↗

Wavefield characterization of nearly diffraction-limited focused hard x-ray beam with size less than 10 nm

In situ wavefront compensation is a promising method to realize a focus size of only a few nanometers for x-ray beams. However, precise compensation requires evaluation of the wavefront with an accuracy much shorter than the wavelength. Here, we characterized a one-dimensionally focused beam with a width of 7 nm at 20 keV using a multilayer mirror. We demonstrate that the wavefront can be determined precisely from multiple intensity profiles measured around the beamwaist. We compare the phase profiles recovered from intensity profiles measured under the same mirror condition but with three different aperture sizes and find that the accuracy of phase retrieval is as small as {lambda}/12.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of an Adaptive Optical System for Sub-10-nm Focusing of Synchrotron Radiation Hard X-rays

In the hard x-ray region, to obtain the theoretical resolution or diffraction-limited focusing size in an imaging optical system, both ultraprecise optics and highly accurate alignment are necessary. An adaptive optical system is used for the compensation of aberrations in various optical systems, such as optical microscopes and space telescopes. In situ wavefront control of hard x-rays is also effective for realizing ideal performance. The aim of this paper is to develop an adaptive optical system for sub-10-nm hard x-ray focusing. The adaptive optical system performs the wavefront measurement using a phase retrieval algorithm and wavefront control using grazing-incidence deformable mirrors. Several results of experiments using the developed system are reported.

43 PARTICLE ACCELERATORS↗