Towards high-efficiency particle detection using superconducting microwire arrays

Here, we present a detailed study of an 8-channel 1×1 mm 2 WSi superconducting microwire single photon detector (SMSPD) array exposed to 120 GeV hadron beam and 120 GeV muon beam at the CERN Super Proton Synchrotron H6 beamline. Following up on our first detailed characterization of the efficiency and response of an SMSPD fabricated on a 3 nm WSi film, we report measurements of enhanced particle detection efficiency using a sensor fabricated from a thicker 4.7 nm-thick WSi film. We also report the first SMSPD detection efficiency measurement made for muons. Measurements are enabled by a silicon tracking telescope providing 10 μm in-situ spatial resolution. The results show a fill factor-normalized detection efficiency of 75% and a time resolution of about 130 ps across pixels. These findings represent a significant advancement toward developing high-efficiency SMSPD charged particle tracking systems with simultaneous precision timing, with potential applications in future accelerator-based experiments such as the FCC-ee and Muon Collider.

Cryogenic detectors↗

Optimizing Magnetic Force Microscopy Resolution and Sensitivity to Visualize Nanoscale Magnetic Domains

Magnetic force microscopy (MFM) enables mapping local magnetic fields across a sample surface with nanoscale resolution. To perform MFM, an atomic force microscopy (AFM) probe whose tip has been magnetized vertically (i.e., perpendicular to the probe cantilever) is oscillated at a fixed height above the sample surface. The resultant shifts in the oscillation phase or frequency, which are proportional to the magnitude and sign of the vertical magnetic force gradient at each pixel location, are then tracked and mapped. Although the spatial resolution and sensitivity of the technique increases with decreasing lift height above the surface, this seemingly straightforward path to improved MFM images is complicated by considerations such as minimizing topographical artifacts due to shorter range van der Waals forces, increasing the oscillation amplitude to further improve sensitivity, and the presence of surface contaminants (in particular water due to humidity under ambient conditions). In addition, due to the orientation of the probe's magnetic dipole moment, MFM is intrinsically more sensitive to samples with an out-of-plane magnetization vector. Here, high-resolution topographical and magnetic phase images of single and bicomponent nanomagnet artificial spin-ice (ASI) arrays obtained in an inert (argon) atmosphere glovebox with <0.1 ppm O 2 and H 2 O are reported. Further, optimization of lift height and drive amplitude for high resolution and sensitivity while simultaneously avoiding the introduction of topographical artifacts is discussed, and detection of the stray magnetic fields emanating from either end of the nanoscale bar magnets (~250 nm long and <100 nm wide) aligned in the plane of the ASI sample surface is shown. Likewise, using the example of a Ni-Mn-Ga magnetic shape memory alloy (MSMA), MFM is demonstrated in an inert atmosphere with magnetic phase sensitivity capable of resolving a series of adjacent magnetic domains each ~200 nm wide.

47 OTHER INSTRUMENTATION↗

A Room PET Scanner for Natural Environment Neuroscience Research

A room size PET scanner for neuroscience research is proposed in which subjects can move about freely in a natural environment. This scanner, termed RoomPET, would open new frontiers in the study of dynamic brain function. The key to a feasible system is PET detectors with a limited vertical dimension that may translate up and down to keep the brain in the field of view. Head position can be tracked by an array of video cameras, providing real-time data to guide detector motion and for motion-corrected image reconstruction. For a point in the center of the room and centered within the vertical field of view of the detectors, geometric sensitivity ranges between 4 and 18% for room widths of 2 to 3 m and detectors with vertical dimensions of 15 to 40 cm. Spatial resolution is dominated by annihilation photon non-colinearity due to the large detector separation. This non-colinearity contribution for F-18 is 4.4 and 6.6 mm full width at half maximum (FWHM) at the center of 2 ×2 and 3×3m 2 rooms, respectively, for a line of response orthogonal to the opposite walls. With pixelated scintillation crystal elements 2 mm on a side the system resolution for F-18 radiotracers is estimated at 4.5 and 6.7 mm FWHM for room widths of 2 and 3 m, respectively. A RoomPET system would advance the understanding of brain function in healthy humans and in those with neurological diseases, disorders and brain injury.

Smith, Mark F.↗

Performance of 8 × 8 × 32 and 10 × 10 × 32 mm 3 CdZnTe position-sensitive virtual Frisch-grid detectors for high-energy gamma ray cameras

CdZnTe (CZT) crystals with thicknesses up to 20 mm and diameters up to 75 mm have become available from Redlen Technologies, Inc. for making large-volume gamma-ray detectors. The modified growth and optimized annealing conditions allowed Redlen to minimize the dark current and improve the uniformity of CZT crystals. Two detector designs, pixelated (H3D) and position-sensitive virtual Frisch-grid (VFG), have greatly benefitted from the availability of such big crystals. Encouraging results from testing of 40×40×15 mm 3 pixelated detectors were recently reported by the University of Michigan. In this work, we evaluated the spectroscopic properties of 8×8×32 and 10×10×32 mm 3 crystals configured as position-sensitive VFG detectors. Both digitized waveforms and an analog ASIC were used to read and process the signals from the detectors and test their spectral- and spatial-resolution. The VFG design provides the flexibility to scale-up the dimensions of the detectors for the desired efficiency, while the position information allows for correcting the detectors' response non-uniformity caused by crystal defects and devices geometry, thereby reducing the instrument cost and making them more feasible for emerging applications in gamma-ray astronomy, nonproliferation, portal screening and nuclear safeguards, where large detector arrays are often required.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Practical considerations in using a binary pseudorandom array for instrument transfer function calibration

Binary pseudo-random array (BPRA) artifacts are useful devices for calibrating the instrument transfer function (ITF) of interferometric microscopes and other optical and non-optical surface and wavefront measurement instruments. The intrinsic white noise character of the power spectral density function of the artifact simplifies the deconvolution of the ITF from the measured power spectral density (PSD). However, resampling of the BPRA intrinsic artifact features with the measurement tool's specific sampling pattern modifies the white noise character of the intrinsic spectrum and needs to be accounted for in the ITF-based data deconvolution process. We have developed an analytic solution to the spectrum of a resampled one- and two- dimensional BPRA. The resultant nominal PSD function is a simple twoparameter cosine function with a period equal to the resampled pixel width. A transfer function model for interferometric microscopes that incorporates this function, along with an ITF that includes aliasing effects and variable numerical aperture (NA), wavelength, and obscuration factor, is used to fit to the BPRA PSDs measured by an interference microscope for a range of objective and zoom lens magnification combinations.

Takacs, PZ↗

Resolve instrument onboard XRISM: design, integration, and instrument test results

The Resolve instrument onboard the X-Ray Imaging and Spectroscopy Mission (XRISM) consists of an array of 6 × 6 silicon-thermistor microcalorimeters cooled down to 50 mK and a high-throughput X-ray mirror assembly (XMA) with a focal length of 5.6 m. XRISM is a recovery mission of ASTRO-H/Hitomi, and the Resolve instrument is a rebuild of the ASTRO-H Soft X-ray spectrometer (SXS) and the Soft X-ray Telescope (SXT) that achieved energy resolution of ∼ 5 eV FWHM on orbit, with several important changes based on lessons learned from ASTRO-H. The flight models of the Dewar and the electronics boxes were fabricated, and the instrument test and calibration were conducted in 2021. By tuning the cryocooler frequencies, energy resolution better than 4.9 eV FWHM at 6 keV was demonstrated for all 36 pixels and high-resolution grade events, as well as energy-scale accuracy better than 2 eV up to 30 keV. The immunity of the detectors to microvibration, electrical conduction, and radiation was evaluated. The instrument was delivered to the spacecraft system in April 2022. The XMA was tested and calibrated separately. Its angular resolution is 1.27′, and the effective area of the mirror itself is 570 cm 2 at 1 keV and 424 cm 2 at 6 keV. We report the design and the major changes from the ASTRO-H SXS, the integration, and the results of the instrument test.

X-ray↗

The 先生 (SENSEI†) Experiment: sub-GeV dark matter searches with skipper-CCD

Skipper-CCDs are pixeled Silicon-based detectors that can perform multiple non-disruptive measurements of the same charge package. Their sub-electron resolution allows the detection of eV energy transfers, such as that expected from ultra-light dark matter interacting with electrons in a Silicon target. SENSEI (Sub-Electron Noise Skipper Experimental Instrument) is the first experiment to use Skipper-CCD for this purpose and to publish world-leading results using this technology. In this talk, we present an overview of the SENSEI experiment and the current status after the successful commissioning of the second batch of science-grade sensors at SNOLAB. We will also discuss the prospects in rare-events searches with skipper-CCDs: from SENSEI’s 100 g detector to OSCURA’s 10 kg array, and more.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The SENSEI Experiment: sub-GeV dark matter searches with skipper-CCDs

Skipper-CCDs are pixeled Silicon-based detectors that can perform multiple non-disruptive measurements of the same charge package. Their sub-electron resolution allows the detection of eV energy transfers, such as that expected from ultra-light dark matter interacting with electrons in a Silicon target. SENSEI (Sub-Electron Noise Skipper Experimental Instrument) is the first experiment to use Skipper-CCD for this purpose and to publish world-leading results using this technology. In this talk, we present an overview of the SENSEI experiment and the current status after the successful commissioning of the second batch of science-grade sensors at SNOLAB. We will also discuss the prospects in rare-events searches with skipper-CCDs: from SENSEI’s 100 g detector to OSCURA’s 10 kg array, and more.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Image-Plane Approach to Gravitational Lens Modeling of Interferometric Data

Strong gravitational lensing acts as a cosmic telescope, enabling the study of the high-redshift universe. Astronomical interferometers, such as the Atacama Large Millimeter/submillimeter Array (ALMA), have provided high-resolution images of strongly lensed sources at millimeter and submillimeter wavelengths. To model the mass and light distributions of lensing and source galaxies from strongly lensed images, strong lens modeling for interferometric observations is conventionally performed in the visibility space, which is computationally expensive. In this paper, we implement an image-plane lens modeling methodology for interferometric dirty images by accounting for noise correlations. We show that the image-plane likelihood function produces accurate model values when tested on simulated ALMA observations with an ensemble of noise realizations. We also apply our technique to ALMA observations of two sources selected from the South Pole Telescope survey, comparing our results with previous visibility-based models. Our model results are consistent with previous models for both parametric and pixelated source-plane reconstructions. We implement this methodology for interferometric lens modeling in the open-source software package lenstronomy.

Zhang, Nan [Illinois U., Urbana (main)] (ORCID:000↗

Analysis and mitigation of an oscillating background on hybrid complementary metal-oxide semiconductor (hCMOS) imaging sensors at the National Ignition Facility

Nanosecond-gated hybrid complementary metal-oxide semiconductor imaging sensors are a powerful tool for temporally gated and spatially resolved measurements in high energy density science, including inertial confinement fusion, and in laser diagnostics. However, a significant oscillating background excited by photocurrent has been observed in image sequences during testing and in experiments at the National Ignition Facility (NIF). Characterization measurements and simulation results are used to explain the oscillations as the convolution of the pixel-level sensor response with a sensor-wide RLC circuit ringing. Finally, data correction techniques are discussed for NIF diagnostics, and for diagnostics where these techniques cannot be used, a proof-of-principle image correction algorithm is presented.

42 ENGINEERING↗

A 24-Channel Digitizer With a JESD204B-Compliant Serial Interface for High-Speed Detectors

In this report a 24-channel application-specific integrated circuit (ASIC) for the readout of high-speed CMOS active pixel sensors for charged particle detection is presented. The chip comprises 24 preamplifiers, 24 distinct 12-bit, 25 MSPS Pipelined analog-to-digital converters (ADCs) with self-calibration, an internal phase-locked loop (PLL), and a 3 Gbps serial interface that conforms to the JESD204B standard. To simplify interfacing with a variety of sensors, the ASIC also includes an automatic offset calibration loop. The high level of integration of the ASIC reduces overall system cost and area, and exploiting the signal characteristics of the image sensor allows the ADC to be optimized for reduced power dissipation. The use of an integrated serializer and an industry standard protocol simplifies integration of the ASIC into a complete camera system. The ASIC, called the High-Speed Image Preprocessor Targeted for Electron Readout, or HIPSTER, with a die area of 64.26 mm 2 , is packaged in a 480-ball grid array (BGA) and is fabricated in 180-nm CMOS technology. HIPSTER achieves typical differential nonlinearity (DNL) < 0.55 LSB, input-referred thermal noise of $114.5 μV-rms, and a bit error rate (BER) of better than 10-14. The power dissipation is 98 mW/channel.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wind Turbine Sound Setbacks and Supply Curves: Ordinances and Extrapolated Trends, 110 Hub Height, 130 Rotor Diameter

This dataset provides a comprehensive set of wind turbine sound setbacks from every residential structure in the contiguous United States (CONUS). A sound setback is defined as the minimum required distance between a residential structure and a hypothetical turbine installation site to ensure that modeled sound levels received at the residence do not exceed local sound ordinances, which are commonly expressed in A-weighted decibels (dBA). Therefore, sound setbacks are a local spatial assessment combining multiple factors, including the sound pressure curve as a function of the observer location (distance and direction) relative to the turbine, local sound regulations, and the geographical distribution of residential structures. The dataset is organized into multiple scenario-based products, detailed as follows: 1. Existing and extrapolated sound setbacks. An existing scenario characterizes sound setbacks only in states or counties that have implemented sound regulations as of 2022. The extrapolated scenarios extend a constant sound threshold to counties that lack explicit sound regulations, with thresholds ranging from 35 to 60 dBA, in 5-dBA increments reflecting the variation observed in current sound ordinances. 2. Sound setbacks in directional and worst scenarios. The directional scenario accounts for the distance and orientation of residential structures relative to a hypothetical turbine location, utilizing the turbine's sound emissions in that specific direction. In contrast, the worst scenario takes loudest sound level at each distance step from the turbine, irrespective of directional considerations, which aligns with current industry practice. 3. Supply curves for Open and Reference Access scenarios. This dataset includes supply curves generated by the reV model, which integrates each of the above sound setbacks into both Open and Reference siting scenarios. In addition, two Open and Reference baselines scenarios were included which do not consider sound setbacks for comparative analysis. All sound setback data are stored in TIF files, with partial maps of the data provided in PNG format. The values in the sound setback raster range from 0 to 1, representing the fraction of developable land within a 90 meter by 90 meter pixel due to sound ordinances. A value of 0 indicates areas where wind energy development is prohibited, while a value of 1 signifies areas fully permissible. The wind turbine parameters used in the sound modeling are based on the land-based turbine from International Energy Agency (IEA), featuring a rated electrical power of 3.4 MW, a rotor diameter of 130 meters, and a hub height of 110 meters. The atmospheric conditions, including wind speed/direction, turbulence, air temperature, relative humidity, and air pressure, that drive the sound generation are obtained from the WIND Toolkit dataset.

Array↗

Simple, compact, high-resolution monochromatic x-ray source for characterization of x-ray calorimeter arrays

X-ray calorimeters routinely achieve very high spectral resolution, typically a few eV full width at half maximum (FWHM). Measurements of calorimeter line shapes are usually dominated by the natural linewidth of most laboratory calibration sources. This compounds the data acquisition time necessary to statistically sample the instrumental line broadening and can add systematic uncertainty if the intrinsic line shape of the source is not well known. To address these issues, we have built a simple, compact monochromatic x-ray source using channel cut crystals. A commercial x-ray tube illuminates a pair of channel cut crystals that are aligned in a dispersive configuration to select the Kα1 line of the x-ray tube anode material. The entire device, including the x-ray tube, can be easily hand-carried by one person and may be positioned manually or using a mechanical translation stage. The output monochromatic beam provides a collimated image of the anode spot with magnification of unity in the dispersion direction (typically 100 μm–200 μm for the x-ray tubes used here) and is unfocused in the cross-dispersion direction so that the source image in the detector plane appears as a line. We measured output count rates as high as 10 count/s/pixel for the Hitomi soft x-ray spectrometer, which had 819 μm square pixels. We implemented different monochromator designs for energies of 5.4 keV (one design) and 8.0 keV (two designs), which have effective theoretical FWHM energy resolution of 0.125 eV, 0.197 eV, and 0.086 eV, respectively; these are well-suited for optimal calibration measurements of state-of-the art x-ray calorimeters. We measured an upper limit for the energy resolution of our Cr Kα1 monochromator of 0.7 eV FWHM at 5.4 keV, consistent with the theoretical prediction of 0.125 eV.

47 OTHER INSTRUMENTATION↗

Characterization of a SiPM-based monolithic neutron scatter camera using dark counts

The Single Volume Scatter Camera (SVSC) Collaboration aims to develop portable neutron imaging systems for a variety of applications in nuclear non-proliferation. Conventional double-scatter neutron imagers are composed of several separate detector volumes organized in at least two planes. A neutron must scatter in two of these detector volumes for its initial trajectory to be reconstructed. As such, these systems typically have a large footprint and poor geometric efficiency. We report on the design and characterization of a prototype monolithic neutron scatter camera that is intended to significantly improve upon the geometrical shortcomings of conventional neutron cameras. The detector consists of a 50 mm×56 mm× 60 mm monolithic block of EJ-204 plastic scintillator instrumented on two faces with arrays of 64 Hamamatsu S13360-6075PE silicon photomultipliers (SiPMs). The electronic crosstalk is limited to < 5% between adjacent channels and < 0.1% between all other channel pairs. SiPMs introduce a significantly elevated dark count rate over PMTs, as well as correlated noise from after-pulsing and optical crosstalk. In this article, we characterize the dark count rate and optical crosstalk and present a modified event reconstruction likelihood function that accounts for them. We find that the average dark count rate per SiPM is 4.3 MHz with a standard deviation of 1.5 MHz among devices. The analysis method we employ to measure internal optical crosstalk also naturally yields the mean and width of the single-electron pulse height. Here, we calculate separate contributions to the width of the single-electron pulse-height from electronic noise and avalanche fluctuations. We demonstrate a timing resolution for a single-photon pulse to be (128 ± 4) ps. Finally, coincidence analysis is employed to measure external (pixel-to-pixel) optical crosstalk. We present a map of the average external crosstalk probability between 2×4 groups of SiPMs, as well as the in-situ timing characteristics extracted from the coincidence analysis. Further work is needed to characterize the performance of the camera at reconstructing single- and double-site interactions, as well as image reconstruction.

47 OTHER INSTRUMENTATION↗

Separating Physically Distinct Mechanisms in Complex Infrared Plasmonic Nanostructures via Machine Learning Enhanced Electron Energy Loss Spectroscopy

Electron energy loss spectroscopy (EELS) enables direct exploration of plasmonic phenomena at the nanometer level. To isolate individual plasmon modes, linear unmixing methods can be used to separate different physical mechanisms, but in larger and more complex systems the interpretability of the components becomes uncertain. Here, infrared plasmonic resonances in self-assembled heterogeneous monolayer films of doped-semiconductor nanoparticles are examined beyond linear unmixing techniques, and both supervised and unsupervised machine-learning-based analyses of hyperspectral EELS datasets are demonstrated. Additionally, in the supervised approach, a human operator labels a small number of pixels in the hyperspectral dataset corresponding to features of interest which are then propagated across the entire dataset. In the unsupervised approach, non-linear autoencoders are used to create a highly-reduced latent-space representation of the dataset, within which insight into the relevant physics can be gleaned from straightforward distance metrics that do not depend on operator input and bias. The advantage of these approaches is that the labeling separates physical mechanisms without altering the data, enabling robust analyses of the influence of heterogeneities in mesoscale complex systems.

36 MATERIALS SCIENCE↗

Intelligent Experiments through Real-Time AI: Fast Data Processing and Autonomous Detector Control for High-Energy Nuclear Experiments

The aim of this project is to develop software and hardware for fast real-time data processing and autonomous detector control and calibration for the sPHENIX and the future EIC experiments. Below summarizes Georgia Tech team efforts in the past year: 1. We developed a real-time clustering algorithm and FPGA-based pipeline architecture for processing fired pixel data from ALPIDE sensors in sPHENIX experiments. Our Columnar Clustering Co-Design introduces a hardware-aware, stream-friendly approach that segments pixel data by column pairs using a Column Pair Clustering (CPC) strategy, followed by Cluster Stitching to merge adjacent subclusters. Implemented in Vitis HLS, the pipeline comprises five stages—read-in, subclustering, stitching, analysis, and write-out—connected by tagged HLS streams with custom end-of-event signaling for robust synchronization. We designed a pipelined dataflow model optimized for throughput, low latency, and minimal buffering, enabling scalable clustering across events of arbitrary size. Our system maintains spatial precision via center-of-mass and shape key extraction and efficiently handles edge cases such as fragmented or nested clusters. Compared against DBSCAN in both software and hardware, our approach demonstrates competitive performance under FPGA constraints. 2. We also conducted a comprehensive algorithm-to-hardware co-design of connected component analysis tailored for sPHENIX experiments, focusing on real-time, low-latency processing using FPGAs and High-Level Synthesis (HLS). Starting from a Python-based particle tracking pipeline, the team translated the core logic—graph traversal via DFS and Union-Find—into an HLS-compatible C++ model, replacing dynamic memory and recursion with static arrays and pipelined control flow. The final design includes a fully streamed and dataflow-compatible Union-Find kernel optimized across five iterations, incorporating loop pipelining, array partitioning, AXI/FIFO interface tuning, and function flattening. Experimental results show up to 14.8× speedup over the CPU baseline, reducing per-graph latency to 1.58 μs and demonstrating strong resource efficiency with only ~7k LUTs and zero BRAM usage. The design maintains functional correctness against the Python reference using a Python-based C-simulation framework and Mean Squared Error metrics. This work validates the potential of HLS-driven FPGA designs for edge-level HEP data acquisition, laying a scalable foundation for future integration with real-time detector pipelines and multi-graph processing systems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Two Year Cosmology Large Angular Scale Surveyor (CLASS) Observations: Long Timescale Stability Achieved with a Front-end Variable-delay Polarization Modulator at 40 GHz

The Cosmology Large Angular Scale Surveyor (CLASS) is a four-telescope array observing the largest angular scales (2≲ ℓ ≲ 200) of the cosmic microwave background (CMB) polarization. These scales encode information about reionization and inflation during the early universe. The instrument stability necessary to observe these angular scales from the ground is achieved through the use of a variable-delay polarization modulator as the first optical element in each of the CLASS telescopes. Here, we develop a demodulation scheme used to extract the polarization timestreams from the CLASS data and apply this method to selected data from the first 2 yr of observations by the 40 GHz CLASS telescope. These timestreams are used to measure the 1/f noise and temperature-to-polarization (T → P) leakage present in the CLASS data. We find a median knee frequency for the pair-differenced demodulated linear polarization of 15.12 mHz and a T → P leakage of <3.8 × 10 -4 (95% confidence) across the focal plane. We examine the sources of 1/f noise present in the data and find the component of 1/f due to atmospheric precipitable water vapor (PWV) has an amplitude of 203 ± 12 µK RJ $\sqrt{{s}}$ for 1 mm of PWV when evaluated at 10 mHz; accounting for ~17% of the 1/f noise in the central pixels of the focal plane. In conclusion, the low levels of T → P leakage and 1/f noise achieved through the use of a front-end polarization modulator are requirements for observing of the largest angular scales of the CMB polarization by the CLASS telescopes.

79 ASTRONOMY AND ASTROPHYSICS↗