Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pixel Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Temperature-dependent characterization of large-area superconducting microwire array with single-photon sensitivity in the near-infrared

Superconducting nanowire single photon detectors (SNSPDs) are a leading detector technology for time-resolved single-photon counting from the ultraviolet to the near-infrared regime. The recent advancement in single-photon sensitivity in micrometer-scale superconducting wires opens up promising opportunities to develop large area SNSPDs with applications in low background dark matter detection experiments. Here, we present the first detailed temperature-dependent study of a 4-channel 1×1 mm 2 WSi superconducting microwire single photon detector (SMSPD) array, including the internal detection efficiency, dark count rate, and importantly the coincident dark counts across pixels. The detector shows saturated internal detection efficiency for photon wavelengths ranging from 635 nm to 1650 nm, time jitter of about 160 ps for 1060 nm photons, and a low dark count rate of about 10 -2 Hz. Additionally, the coincidences of dark count rate across pixels are studied for the first time in detail, where we observed an excess of correlated dark counts, which has important implications for low background dark matter experiments. The results presented is the first step towards characterizing and developing SMSPD array systems and associated background for low background dark matter detection experiments.

47 OTHER INSTRUMENTATION↗

Quantum correlation imaging via X-ray parametric down-conversion

Quantum imaging leverages correlations between pairs of photons and has the potential to obtain image information beyond what classical sources provide. Extending this approach to the X-ray regime has been limited by low photon-pair generation rates and the lack of suitable detectors. Here, we demonstrate X-ray coincidence imaging using spontaneous parametric down-conversion (SPDC) and a pixelated area detector with time- and energy-resolved capabilities. This configuration enables simultaneous detection of correlated X-ray photon pairs and coincidence-based imaging of test objects, including a biological specimen. The increased coincidence rate and spatially resolved detection establish a basis for future quantum-enhanced and low-dose X-ray imaging.

Goodrich, Justin C. [Brookhaven National Laborator↗

Low spin spectroscopy of neutron-rich Cl 43 , 44 , 45 via β - and β n decay

In this article, β - decay studies of neutron-rich isotopes 43,45 S performed at the National Superconducting Cyclotron Laboratory are reported. β -delayed $\gamma$ transitions were detected by an array of 16 clover detectors surrounding the Beta Counting Station, which consists of a 40×40 double-sided silicon strip detector followed by a single-sided silicon strip detector. β -decay half-lives were extracted for 43,45 S by correlating implants and decays in the pixelated implant detector and by considering further coincidences with $\gamma$ transitions in the daughter nuclei. Further, the level structures of 43,45 Cl are expanded by the addition of 20 and 8 new $\gamma$ transitions in 43 Cl and 45 Cl respectively, and core-excited negative-parity states were observed in both nuclei for the first time. For 45 S, a large fraction of the β -decay strength was observed feeding neutron-unbound states in 45 Cl, which, decaying by delayed neutrons, populated excited states in the β ⁢1⁢ n daughter, 44 Cl. Experimental observations were compared to detailed shell-model calculations using the SDPFSDG-MU interaction to highlight the role of the diminished N = 28 neutron shell gap and the near degeneracy of the proton s 1/2 and d 3/2 orbitals in the structure of the neutron-rich Cl isotopes. The current work also provides further support to a ground-state spin-parity assignment of 3/2 + in 45 Cl.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Heavy Flavor Physics at the sPHENIX Experiment

The sPHENIX experiment is a state-of-the-art jet and heavy flavor physics detector, which successfully recorded its first Au + Au collision data at 200 GeV at the Relativistic Heavy Ion Collider (RHIC). sPHENIX will provide heavy flavor physics measurements at RHIC, covering an unexplored kinematic region and unprecedented precision, to probe the parton energy loss mechanism, parton transport coefficients in quark–gluon plasma, and the hadronization process under various medium conditions. At the center of sPHENIX, the monolithic active pixel sensor (MAPS)-based VerTeX detector (MVTX) is a high-precision silicon pixel detector. The MVTX provides excellent position resolution and the capability of operating in continuous streaming readout mode, allowing precise vertex determination and recording a large data sample, both of which are particularly crucial for heavy flavor physics measurements. In this work, we will show the general performance of heavy-flavor hadron reconstruction. In addition, we will discuss the commissioning experience with sPHENIX. Finally, we will provide the projection of b-hadron and jet observables and discuss the estimated constraints on theoretical models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of the CMS detector for the CERN LHC Run 3

Since the initial data taking of the CERN LHC, the CMSexperiment has undergone substantial upgrades and improvements. Thispaper discusses the CMS detector as it is configured for the thirddata-taking period of the CERN LHC, Run 3, which started in2022. The entire silicon pixel tracking detector was replaced. A newpowering system for the superconducting solenoid was installed. Theelectronics of the hadron calorimeter was upgraded. All the muonelectronic systems were upgraded, and new muon detector stationswere added, including a gas electron multiplier detector. Theprecision proton spectrometer was upgraded. The dedicated luminositydetectors and the beam loss monitor were refurbished. Substantialimprovements to the trigger, data acquisition, software, andcomputing systems were also implemented, including a new hybridCPU/GPU farm for the high-level trigger.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SuperHERO: The Next Generation Hard X-ray HEROES Telescope

SuperHERO is a new high-sensitivity Long Duration Balloon (LDB)-capable, hard-x-ray (20-75 keV) telescope for making novel astrophysics and heliophysics observations. The proposed SuperHERO payload will be developed jointly by the Astrophysics Office at NASA Marshall Space Flight Center, the Solar Physics Laboratory and Wallops Flight Facility at NASA Goddard Space Flight Center. SuperHERO is a follow-on payload to the High Energy Replicated Optics to Explore the Sun (HEROES) balloon-borne telescope that recently launched from Fort Sumner, NM in September of 2013. The HEROES core instrument is a hard x-ray telescope consisting of x-ray 109 optics configured into 8 modules. Each module is aligned to a matching gas-filled detector at a focal length of 6 m. SuperHERO will make significant improvements to the HEROES payload, including: new solid-state multi-pixel CdTe detectors, additional optics, the Wallops Arc-Second Pointer, alignment monitoring systems and lighter gondola.

Gaskin, Jessica A.↗

SuperHERO: The Next Generation Hard X-Ray HEROES Telescope

SuperHERO is a new high-sensitivity Long Duration Balloon (LDB)-capable, hard-x-ray (20-75 keV) telescope for making novel astrophysics and heliophysics observations. The proposed SuperHERO payload will be developed jointly by the Astrophysics Office at NASA Marshall Space Flight Center, the Solar Physics Laboratory and Wallops Flight Facility at NASA Goddard Space Flight Center. SuperHERO is a follow-on payload to the High Energy Replicated Optics to Explore the Sun (HEROES) balloon-borne telescope that recently launched from Fort Sumner, NM in September of 2013. The HEROES core instrument is a hard x-ray telescope consisting of x-ray 109 optics configured into 8 modules. Each module is aligned to a matching gas-filled detector at a focal length of 6 m. SuperHERO will make significant improvements to the HEROES payload, including: new solid-state multi-pixel CdTe detectors, additional optics, the Wallops Arc-Second Pointer, alignment monitoring systems and lighter gondola.

Wilson-Hodge, Colleen A.↗

Design, Fabrication, and Testing of a TiN Ti TiN Trilayer KID Array for 3mm CMB Observations

Kinetic inductance detectors (KIDs) are a promising technology for astronomical observations over a wide range of wavelengths in the mm and sub-mm regime. Simple fabrication, in as little as one lithographic layer, and passive frequency-domain multiplexing, with readout of up to 1000 pixels on a single line with a single cold amplifier, make KIDs an attractive solution for high-pixel-count detector arrays. We are developing an array that optimizes KIDs for optical frequencies near 100GHz to expand their usefulness in mm-wave applications, with a particular focus on CMBB-mode measurement efforts in association with the QUBIC telescope. We have designed, fabricated, and tested a 20-pixel prototype array using a simple quasi lumped microstrip design and pulsed DC reactive magnetron-sputtered TiNTiTiN trilayer resonators, optimized for detecting 100GHz (3mm) signals. Here we present a discussion of design considerations for the array, as well as preliminary detector characterization measurements and results from a study of TiN trilayer properties.

passive frequency-domain multiplexing↗

Cross Section Measurements Using the Zero Degree Detector

The Zero Degree Detector (ZDD) is an instrument that has been used in accelerator exposures to measure the angular dependence of particles produced in heavy ion fragmentation experiments. The ZDD uses two identical layers of pixelated silicon detectors that make coincident measurements over the active area of the instrument. The angular distribution of secondary particle produced in nuclear interactions for several heavy ions: and target materials will be presented along with performance characteristic of the instrument.

Christl, M. J.↗

Evaluation of radiation hardness of semiconductor materials against alpha particles for an API detector

An Associated Particle Imaging (API) system consists of a high vacuum chamber where deuterium ions are accelerated on a tritium-loaded target, resulting in alpha particles and neutrons emitted back-to-back, the latter escaping the chamber and used, for example, for tomography of a high-Z sample. An accurate determination of the alpha position is crucial to determine the trajectory of the neutron. Existing API systems have several limitations which a semiconductor-based API detector placed inside the vacuum chamber should not present. The semiconductor material can be either silicon or diamond. In particular, large and fast signals are generated by the alpha interactions in these materials. A pixelated API detector will measure the time and hit position of the alphas produced in the reaction. However, during the lifetime of the generator, the semiconductor detector will be exposed to an intense flux of alpha particles that will degrade its performance over time. To assess the radiation hardness of silicon and diamond against the alpha particles, we exposed single diodes made of either of the two materials to a 5 MeV alpha flux generated by an 241Am radioactive source. During irradiation, the diodes were biased and mounted on current-sensitive preamplifier boards. We have therefore been able to measure insitu the evolution of the waveforms as the damage was accumulating in their substrates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantifying Dynamic Signal Spread in Real-Time High-Energy X-ray Diffraction

Abstract Measured intensity in high-energy monochromatic X-ray diffraction (HEXD) experiments provides information regarding the microstructure of the crystalline material under study. The location of intensity on an areal detector is determined by the lattice spacing and orientation of crystals so that changes in the heterogeneity of these quantities are reflected in the spreading of diffraction peaks over time. High temporal resolution of such dynamics can now be experimentally observed using technologies such as the mixed-mode pixel array detector (MM-PAD) which facilitates in situ dynamic HEXD experiments to study plasticity and its underlying mechanisms. In this paper, we define and demonstrate a feature computed directly from such diffraction time series data quantifying signal spread in a manner that is correlated with plastic deformation of the sample. A distinguishing characteristic of the analysis is the capability to describe the evolution from the distinct diffraction peaks of an undeformed alloy sample through to the non-uniform Debye–Scherrer rings developed upon significant plastic deformation. We build on our previous work modeling data using an overcomplete dictionary by treating temporal measurements jointly to improve signal spread recovery. We demonstrate our approach in simulations and on experimental HEXD measurements captured using the MM-PAD. Our method for characterizing the temporal evolution of signal spread is shown to provide an informative means of data analysis that adds to the capabilities of existing methods. Our work draws on ideas from convolutional sparse coding and requires solving a coupled convex optimization problem based on the alternating direction method of multipliers.

Engineering↗

Rapid sensing of hidden objects and defects using a single-pixel diffractive terahertz sensor

Abstract Terahertz waves offer advantages for nondestructive detection of hidden objects/defects in materials, as they can penetrate most optically-opaque materials. However, existing terahertz inspection systems face throughput and accuracy restrictions due to their limited imaging speed and resolution. Furthermore, machine-vision-based systems using large-pixel-count imaging encounter bottlenecks due to their data storage, transmission and processing requirements. Here, we report a diffractive sensor that rapidly detects hidden defects/objects within a 3D sample using a single-pixel terahertz detector, eliminating sample scanning or image formation/processing. Leveraging deep-learning-optimized diffractive layers, this diffractive sensor can all-optically probe the 3D structural information of samples by outputting a spectrum, directly indicating the presence/absence of hidden structures or defects. We experimentally validated this framework using a single-pixel terahertz time-domain spectroscopy set-up and 3D-printed diffractive layers, successfully detecting unknown hidden defects inside silicon samples. This technique is valuable for applications including security screening, biomedical sensing and industrial quality control.

Li, Jingxi (ORCID:0000000165958680)↗

Fast digital lossy compression for X-ray ptychographic data

Increases in X-ray brightness from synchrotron light sources lead to a requirement for higher frame rates from hybrid pixel array detectors (HPADs), while also favoring charge integration over photon counting. However, transfer of the full uncompressed data will begin to constrain detector design, as well as limit the achievable continuous frame rate. Here a data compression scheme that is easy to implement in a HPAD's application-specific integrated circuit (ASIC) is described, and how different degrees of compression affect image quality in ptychography, a commonly employed coherent imaging method, is examined. Using adaptive encoding quantization, it is shown in simulations that one can digitize signals up to 16383 photons per pixel (corresponding to 14 bits of information) using only 8 or 9 bits for data transfer, with negligible effect on the reconstructed image.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantitative uranium elemental reconstruction using spectral x-ray radiography

X-ray radiography offers the ability to noninvasively inspect the internal structure and material composition of objects. Dual-energy radiography allows material discrimination but is limited in quantitative material measurements due to the broad nature of the interrogating x-ray spectrum. Spectral radiography detectors provide an observation of not just the number of x rays that are transmitted through a sample but also the spectrum. Here, experimental validations of a method to use spectral x-ray radiography to accurately quantify the uranium mass in a powder are presented. An accurate system response model was developed, which includes a model of the incident x-ray source spectrum and a pixel-wise detector response that describes how the transmitted x rays were observed. Further, a calibration to account for the effect of partial x-ray attenuation was developed. As a result, the method is demonstrated to be capable of estimating the uranium mass in a variety of uranium oxide powders to a bias of –0.01±0.62%.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Method for the Absolute Calibration of the Location and Orientation of Large-Format Detectors Using Laser Radar

A method of mapping pixel locations of a detector array includes measuring a location on the detector array, initiating a frame readout of the detector array, measuring a location of one or more metrology targets on the detector array, analyzing the frame readout to identify a pixel at the location on the detector array, and defining a location of the identified pixel with respect to the location of the one or more metrology targets. Subsequent measurement of the metrology targets alone by another metrology system allows one to infer the six degree of freedom alignment of the detector array in space.

Coulter, Phillip↗

Characterization of MKIDs for CMB Observation at 220 GHz With the South Pole Telescope

We present an updated design of the 220 GHz microwave kinetic inductance detector (MKID) pixel for SPT-3G+, the next-generation camera for the South Pole Telescope. We show results of the dark testing of a 63-pixel array with mean inductor quality factor $Q_{i} = 4.8 \times 10^{5}$, aluminum inductor transition temperature $T_{c} = 1.19$K, and kinetic inductance fraction $\alpha _{k} = 0.32$. We optically characterize both the microstrip-coupled and CPW-coupled resonators, and find both have a spectral response close to prediction with an optical efficiency of $\eta \sim 70\%$. However, we find slightly lower optical response on the lower edge of the band than predicted, with neighboring dark detectors showing more response in this region, though at level consistent with less than 5% frequency shift relative to the optical detectors. The detectors show polarized response consistent with expectations, with a cross-polar response of $\sim 10\%$for both detector orientations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved Nondestructive Isotopic Analysis with Practical Microcalorimeter Gamma Spectrometers

Advances in both instrumentation and data analysis software are now enabling the first ultra-high-resolution microcalorimeter gamma spectrometers designed for implementation in nuclear facilities and analytical laboratories. With approximately ten times better energy resolution than high-purity germanium detectors, these instruments can overcome important uncertainty limits. Microcalorimeter gamma spectroscopy is intended to provide nondestructive isotopic analysis capabilities with sufficient precision and accuracy to reduce the need for sampling, chemical separations, and mass spectrometry to meet safeguards and security goals. Key milestones were the development of the SOFIA instrument (Spectrometer Optimized for Facility Integrated Applications) and the SAPPY software (Spectral Analysis Program in PYthon). SOFIA is a compact instrument that combines advances in large multiplexed transition-edge sensor arrays with optimized cryogenic performance to overcome many practical limitations of previous systems. With a 256-pixel multiplexed detector array capable of 5,000 counts per second, measurement time can be comparable to high-purity germanium detectors. SAPPY was developed to determine isotopic ratios in data from SOFIA and other microcalorimeter instruments with an approach similar to the widely-used FRAM software. SAPPY provides a flexible framework with rigorous uncertainty analysis for both microcalorimeter and high purity germanium (HPGe) data, allowing direct comparison. Here, we present current results from the SOFIA instrument, preliminary isotopic analysis using SAPPY, and describe how the technology is being used to explore uncertainty limits of nondestructive isotopic characterization, inform safeguards models, and extract improved nuclear data including gamma-ray branching ratios.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Imaging X-Ray Polarimetry Explorer (IXPE): Technical Overview IV

Scheduled to launch in late 2021,the Imaging X-ray Polarimetry Explorer (IXPE) is a Small Explorer Mission designed to open up a new window of investigation --X-ray polarimetry. The IXPE observatory features 3 identical telescopes each consisting of a mirror module assembly with a polarization-sensitive imaging x-ray detector at its focus. An extending boom, deployed on orbit, provides the necessary 4 m focal length. The payload sits atop a 3-axis stabilized spacecraft which, among other things, provides power, attitude determination and control, commanding, and telemetry to the ground. During its 2-year baseline mission, IXPE will conduct precise polarimetry for samples of multiple categories of x-ray sources, with follow-on observations of selected targets. IXPE is a partnership between NASA and the Italian Space Agency (ASI).

X-ray polarimetry↗