The effect of viewing angle on the spectral behavior of a Gd plasma source near 6.7 nm

We have demonstrated the effect of viewing angle on the extreme ultraviolet (EUV) emission spectra of gadolinium (Gd) near 6.7 nm. The spectra are shown to have a strong dependence on viewing angle when produced with a laser pulse duration of 10 ns, which may be attributed to absorption by low ion stages of Gd and an angular variation in the ion distribution. Absorption effects are less pronounced at a 150-ps pulse duration due to reduced opacity resulting from plasma expansion. Thus for evaluating source intensity, it is necessary to allow for variation with both viewing angle and target orientation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser-driven plasma sources of intense, ultrafast, and coherent radiation

High-power lasers can deliver extreme light intensities, but avoiding damage in optical components requires large beam sizes, hindering further advances. The use of plasma as a medium for generating and manipulating light avoids the damage thresholds of solid materials and can support extraordinarily bright radiation. In this work, we discuss here how parametric plasma amplification and relativistic high-order harmonic generation offer paths to the development of light sources with peak powers beyond the capabilities of solid-state optics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Angular and energy distribution of Sn ion debris ejected from a laser-produced plasma source, for laser power densities in the range suitable for extreme ultraviolet lithography

In this paper, experimental results are presented for the spatial and energy distributions of charge-discriminated Sn ions ejected from laser-produced plasmas. The plasmas were formed on solid, planar Sn targets, irradiated with a Nd:YAG laser. Ions were investigated using a calibrated electrostatic sector analyzer, scanning an energy-to-charge ratio range of 0.22 to 2.2 keV/e for emission angles between 20 and 80 degrees relative to target normal. Results were obtained for three laser power densities, in the region suitable for inducing significant extreme ultraviolet emission, of the order 1.5-8.1 x 10{sup 11} W/cm{sup 2}. The fully differentiated data were found to be well characterized by Gaussian fits, which allowed trends in the emission profiles to be readily quantified. Ions of set energy and charge were observed to possess a preferential angle of emission, the superposition of which yields a physical basis for the total angular emission observed previously and in this work. The experimental results obtained have been related to physical processes within the plasma that influence the energy and angle of ejection of ions from laser produced plasmas.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dual radio frequency plasma source: Understanding via electrical asymmetry effect

On the basis of the global model, the influences of driving voltage and frequency on electron heating in geometrically symmetrical dual capacitively coupled radio frequency plasma have been investigated. Consistent with the experimental and simulation results, non-monotonic behavior of dc self bias and plasma heating with increasing high frequency is observed. In addition to the local maxima of plasma parameters for the integer values of the ratio between the frequencies ({xi}), ourstudies also predict local maxima for odd integer values of 2{xi} as a consequence of the electrical asymmetry effect produced by dual frequency voltage sources.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A segmented multi-loop antenna for selective excitation of azimuthal mode number in a helicon plasma source

A flat type, segmented multi-loop antenna was developed in the Tokai Helicon Device, built for producing high-density helicon plasma, with a diameter of 20 cm and an axial length of 100 cm. This antenna, composed of azimuthally splitting segments located on four different radial positions, i.e., r = 2.8, 4.8, 6.8, and 8.8 cm, can excite the azimuthal mode number m of 0, ±1, and ±2 by a proper choice of antenna feeder parts just on the rear side of the antenna. Power dependencies of the electron density n{sub e} were investigated with a radio frequency (rf) power less than 3 kW (excitation frequency ranged from 8 to 20 MHz) by the use of various types of antenna segments, and n{sub e} up to ∼5 × 10{sup 12} cm{sup −3} was obtained after the density jump from inductively coupled plasma to helicon discharges. Radial density profiles of m = 0 and ±1 modes with low and high rf powers were measured. For the cases of these modes after the density jump, the excited mode structures derived from the magnetic probe measurements were consistent with those expected from theory on helicon waves excited in the plasma.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of an Actively Cooled Window for High Power Helicon Plasma Source

The development of the next generation of magnetically confined fusion facilities towards commercial fusion power will depend on an increased understanding of plasma material interactions (PMI). Plasma facing components in future facilities such as a Fusion Nuclear Science Facility (FSNF) or DEMO will experience high heat fluxes, high energy neutron fluence, and helium and hydrogen isotope permeation. This combination of environmental effects is unique to the fusion environment, and research and development in the field of PMI will require integrated facilities that can provide prototypical conditions. Particularly, facilities are required that will simulate conditions in the first wall and divertor regions. One such proposed facility is Materials Plasma Exposure experiment (MPEX). (authors)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of Fluctuations in the CW Penning Surface-Plasma Source of Negative Ions

Study of current fluctuations for cw Penning SPS with hollow cathode drive was done. The noiseproof measurements of negative ion beam current, current in extracted electrode circuit, discharge current and voltage were carried out by the low-inductive probes in wide frequency range. Spectrum and intensity of fluctuations at various operation modes, parameters and electrode geometry were recorded for two versions of cw Penning SPS. H{sup -} beam current and the extracted electrode circuit current had the level of ripples higher, than the ripples in discharge current and voltage signals. Frequency spectrum of beam and discharge fluctuations displayed stable peaks. The main peak had location in the range 0.1 divide 1.5 MHz and FWHM of about 0.1 MHz. For the basic operational mode the main peak in frequency spectrum was in the range 0.3-0.4 MHz. The fluctuations of current in extracted electrode circuit and in accelerated electrode circuit had the similar structure and correlated with beam current fluctuations. The obtained data show that plasma density oscillations are responsible for the beam current fluctuations. The 0.1 divide 1.5 MHz fluctuations of plasma density could be produced by oscillations of cathode emissivity and of discharge current distribution between the specific cathode regions.

43 PARTICLE ACCELERATORS↗

The influence of the extraction voltage on the energetic electron population of an electron cyclotron resonance ion source plasma

An influence of the extraction voltage on the high energy slope of bremsstrahlung radiation spectra has been reported in ECRIS experiments, which is not well understood so far. In order to provide more detailed data on this effect, we have measured bremsstrahlung radiation spectra accompanying especially the evolution of highly charge ions (i.e., by monitoring the Ar{sup 14+} charge state) as the extraction voltage is changed from 0 to 20 kV, in dedicated experiments at the Frankfurt 14 GHz-ECRIS.

43 PARTICLE ACCELERATORS↗

450 mm dual frequency capacitively coupled plasma sources: Conventional, graded, and segmented electrodes

Wafer diameters for microelectronics fabrication will soon transition from 300 to 450 mm at a time when excitation frequencies for capacitively coupled plasmas (CCPs) are increasing to 200 MHz or higher. Already for 300 mm tools, there is evidence that wave behavior (i.e., propagation, constructive, and destructive interference) affects the uniformity of processing. The increase in diameter to 450 mm is likely to exacerbate these effects, perhaps requiring nontraditional tool designs. This is particularly important in dual frequency (DF) CCP tools in which there are potential interactions between frequencies. In this paper, results from a two-dimensional computational investigation of Ar plasma properties in a 450 mm DF-CCP reactor, incorporating a full-wave solution of Maxwell's equations, are discussed. As in 300 mm DF-CCP reactors, the electron density collapses toward the center of the reactor with increasing high frequency (HF), however, with more pronounced finite wavelength effects. Graded conductivity electrodes with multilayer of dielectrics are computationally demonstrated as a possible means to suppress wave effects thereby increasing plasma uniformity. Segmentation of the HF electrode also improves the plasma uniformity by making the electrical distance between the feeds and the sheath edges as uniform as possible.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetic-Nozzle Studies for Fusion Propulsion Applications: Gigawatt Plasma Source Operation and Magnetic Nozzle Analysis

This project has been a multiyear effort to assess the feasibility of a key process inherent to virtually all fusion propulsion concepts: the expansion of a fusion-grade plasma through a diverging magnetic field. Current fusion energy research touches on this process only indirectly through studies of plasma divertors designed to remove the fusion products from a reactor. This project was aimed at directly addressing propulsion system issues, without the expense of constructing a fusion reactor. Instead, the program designed, constructed, and operated a facility suitable for simulating fusion reactor grade edge plasmas, and to examine their expansion in an expanding magnetic nozzle. The approach was to create and accelerate a dense (up to l0(exp 20)/m) plasma, stagnate it in a converging magnetic field to convert kinetic energy to thermal energy, and examine the subsequent expansion of the hot (100's eV) plasma in a subsequent magnetic nozzle. Throughout the project, there has been a parallel effort between theoretical and numerical design and modelling of the experiment and the experiment itself. In particular, the MACH2 code was used to design and predict the performance of the magnetoplasmadynamic (MPD) plasma accelerator, and to design and predict the design and expected behavior for the magnetic field coils that could be added later. Progress to date includes the theoretical accelerator design and construction, development of the power and vacuum systems to accommodate the powers and mass flow rates of interest to out research, operation of the accelerator and comparison to theoretical predictions, and computational analysis of future magnetic field coils and the expected performance of an integrated source-nozzle experiment.

Gilland, James H.↗

Evaluation of a fourth-generation focal plane camera for use in plasma-source mass spectrometry

A fourth-generation focal plane camera containing 1696 Faraday-strip detectors was fitted to a Mattauch-Herzog mass spectrograph and characterized for its performance with inductively coupled plasma ionization. The camera provides limits of detection in the single to tens of ng L-1 range for most elements and has a linear dynamic range of at least nine orders of magnitude. Isotope-ratio precision better than 0.02% has also been achieved with this device, and this fourth-generation system features the broadest simultaneous mass range obtainable to date with this family of focal plane camera detectors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct measurements of classical and enhanced gradient-aligned cross-field ion flows in a helicon plasma source using laser-induced fluorescence

Direct laser induced fluorescence measurements are shown of cross-field ion flows normal to an absorbing boundary that is aligned parallel to the axial magnetic field in a helicon plasma. We show Langmuir and emissive probe measurements of local density and plasma potential in the same region, as well as floating probe spectra near the boundary. With these measurements, we investigate the influence of ion-neutral collisionality on radial ion transport by varying the ratio of the ion gyro-radius, ρ{sub i}, to the ion-neutral collision length, λ, over the range 0.34 ≤ ρ{sub i}λ{sup −1} ≤ 1.60. Classical drift-diffusion transport along density and potential gradients is sufficient to describe flow profiles for most cases. For two parameter regimes (ρ{sub i}λ{sup −1} = 0.65 and 0.44), low-frequency electrostatic fluctuations (f < 10 kHz) and enhanced cross-field bulk ion flow to the boundary are observed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Note: Arc discharge plasma source with plane segmented LaB{sub 6} cathode

A plane cathode composed of close-packed hexagonal LaB{sub 6} (lanthanum hexaboride) segments is described. The 6 cm diameter circular cathode is heated by radiation from a graphite foil flat spiral. The cathode along with a hollow copper anode is used for the arc discharge plasma production in a newly developed linear plasma device. A separately powered coil located around the anode is used to change the magnetic field strength and geometry in the anode region. Different discharge regimes were realized using this coil.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Highly ionized physical vapor deposition plasma source working at very low pressure

Highly ionized discharge for physical vapor deposition at very low pressure is presented in the paper. The discharge is generated by electron cyclotron wave resonance (ECWR) which assists with ignition of high power impulse magnetron sputtering (HiPIMS) discharge. The magnetron gun (with Ti target) was built into the single-turn coil RF electrode of the ECWR facility. ECWR assistance provides pre-ionization effect which allows significant reduction of pressure during HiPIMS operation down to p = 0.05 Pa; this is nearly more than an order of magnitude lower than at typical pressure ranges of HiPIMS discharges. We can confirm that nearly all sputtered particles are ionized (only Ti{sup +} and Ti{sup ++} peaks are observed in the mass scan spectra). This corresponds well with high plasma density n{sub e} {approx} 10{sup 18} m{sup -3}, measured during the HiPIMS pulse.

43 PARTICLE ACCELERATORS↗

Development of an atmospheric-pressure homogeneous and cold Ar/O{sub 2} plasma source operating in glow discharge

An atmospheric-pressure Ar/O{sub 2} glow discharge is generated in a parallel bare metal plate reactor with a radio-frequency power supply by introducing a dielectric strip in the inlet of the gas flow. The role of the dielectric strip is discussed experimentally. The allowable oxygen-to-argon ratio reaches 1.0 vol % and the generated Ar/O{sub 2} plasma discharge is characterized by a low gas temperature and good spatial homogeneity, implying its feasible application as a type of material treatment for a large-area surface, as illustrated experimentally by the ashing of carbon black.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design and characterization of 2.45 GHz electron cyclotron resonance plasma source with magnetron magnetic field configuration for high flux of hyperthermal neutral beam

A 2.45 GHz electron cyclotron resonance (ECR) source with a magnetron magnetic field configuration was developed to meet the demand of a hyperthermal neutral beam (HNB) flux on a substrate of more than 1x10{sup 15} cm{sup -2} s{sup -1} for industrial applications. The parameters of the operating pressure, ion density, electron temperature, and distance between the neutralization plate and the substrate for the HNB source are specified in a theoretical analysis. The electron temperature and the ion density are measured to characterize the ECR HNB source using a Langmuir probe and optical emission spectroscopy. The parameters of the ECR HNB source are in good agreement with the theoretically specified parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Discharge regime of non-ambipolarity with a self-induced steady-state magnetic field in plasma sources with localized radio-frequency power deposition

Involving the idea for the Biermann effect known from space physics as well as recent discussions on non-ambipolarity of the electron and ion fluxes in low-pressure discharges, the study builds the discharge pattern in a source with localized RF power deposition outside the region of high electron density. A vortex dc current flowing in an RF discharge and a steady-state magnetic field induced by this current govern the discharge behavior. Owing to a shift in the positions of the electron-density and plasma-potential maxima, the dc current is driven with the purpose of keeping the conservativity of the dc field in the discharge. The results present the spatial structure of a discharge in a regime of non-ambipolarity of the electron and ion fluxes, including its modifications by the magnetic field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Estimation of the Lyman-{alpha} line intensity in a lithium-based discharge-produced plasma source

Extreme ultraviolet (EUV) discharge-based lamps for EUV lithography need to generate extremely high power in the narrow spectrum band of 13.5{+-}0.135 nm. A simplified time-dependent collisional-radiative model and radiative transfer solution were utilized to investigate the wavelength-integrated Lyman-{alpha} line light outputs in a hydrogen-like lithium ion. The study reveals in particular that a steady-state or magnetically confined lithium plasma radiates in the desired spectrum band not less than 1 kW in 2{pi} sr even at an ion density region as low as 10{sup 17} cm{sup -3}.