Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

High resolution (1 km) positive degree-day modelling of Greenland ice sheet surface mass balance, 1870–2012 using reanalysis data

Here, we show results from a positive degree-day (PDD) model of Greenland ice sheet (GrIS) surface mass balance (SMB), 1870–2012, forced with reanalysis data. The model includes an improved daily temperature parameterization as compared with a previous version and is run at 1 km rather than 5 km resolution. The improvements lead overall to higher SMB with the same forcing data. We also compare our model with results from two regional climate models (RCMs). While there is good qualitative agreement between our PDD model and the RCMs, it usually results in lower precipitation and lower runoff but approximately equivalent SMB: mean 1979–2012 SMB (± standard deviation), in Gt a –1 , is 382 ± 78 in the PDD model, compared with 379 ± 101 and 425 ± 90 for the RCMs. Comparison with in situ SMB observations suggests that the RCMs may be more accurate than PDD at local level, in some areas, although the latter generally compares well. Dividing the GrIS into seven drainage basins we show that SMB has decreased sharply in all regions since 2000. Finally we show correlation between runoff close to two calving glaciers and either calving front retreat or calving flux, this being most noticeable from the mid-1990s.

54 ENVIRONMENTAL SCIENCES↗

The fundamental bands of HCl-35 and HCl-37 - Line positions from high-resolution laboratory data

Accurate measurements of the positions of lines of the (1-0) vibration-rotation bands of HCl-35 and HCl-37 are reported. The new measurements have been derived from a laboratory spectrum recorded with a Fourier transform spectrometer operated at an unapodized spectral resolution of 0.0060/cm. Molecular constants are reported from a simultaneous least-squares analysis of these measurements and selected infrared and far-infrared data taken from the literature. The motivation for the present investigation is the need for improved HCl line positions for use in IR atmospheric remote sensing investigations.

Rinslad, Curtis P.↗

Sensor for Boundary Shear Stress in Fluid Flow

The formation of scour patterns at bridge piers is driven by the forces at the boundary of the water flow. In most experimental scour studies, indirect processes have been applied to estimate the shear stress using measured velocity profiles. The estimations are based on theoretical models and associated assumptions. However, the turbulence flow fields and boundary layer in the pier-scour region are very complex and lead to low-fidelity results. In addition, available turbulence models cannot account accurately for the bed roughness effect. Direct measurement of the boundary shear stress, normal stress, and their fluctuations are attractive alternatives. However, most direct-measurement shear sensors are bulky in size or not compatible to fluid flow. A sensor has been developed that consists of a floating plate with folded beam support and an optical grid on the back, combined with a high-resolution optical position probe. The folded beam support makes the floating plate more flexible in the sensing direction within a small footprint, while maintaining high stiffness in the other directions. The floating plate converts the shear force to displacement, and the optical probe detects the plate s position with nanometer resolution by sensing the pattern of the diffraction field of the grid through a glass window. This configuration makes the sensor compatible with liquid flow applications.

Bao, Xiaoqi↗

The fundamental quadrupole band of (N-14)2 - Line positions from high-resolution stratospheric solar absorption spectra

Accurate measurements of the positions of O- and S-branch lines of the (1-0) vibration-rotation quadrupole band of molecular nitrogen (N-14)2 are reported. Improved Dunham coefficients were derived from a simultaneous least squares analysis of these measurements and selected infrared and far infrared data. The new measurements were performed using stratospheric solar occultation spectra recorded with Fourier transform spectrometer instruments, operated at unapodized spectral resolutions of 0.002 and 0.01/cm.

Rinsland, C. P.↗

Design and Performance of the CdZnTe VFG Imaging Calorimeter Prototype for Gamma-ray Astronomy

We present the design and first results of the CdZnTe Imaging calorimeter prototype. The CdZnTe Imaging calorimeter has been designed for use in large astrophysical gamma-ray space instruments, and we report here on a small prototype built to validate the approach. The calorimeter is based on virtual Frisch-grid drift-bar CdZnTe detectors. The design is modular, such that multiple crates of 16 bars, each served by a single ASIC, can be arranged in to different configurations depending on the specific requirements for an instrument. The modules are plugged into the readout motherboard in the designed configuration for a given instrument. The detectors are capable of measuring the interaction point of an incident photon in three dimensions and the energy deposited. In this work, we have designed and built a prototype consisting of 4 by 4 module array and have tested it with various radioactive sources to measure its position and energy resolution. The preliminary results demonstrate ~1% FWHM energy resolution and 1-2 mm position resolution for 662 keV photons (Cs137), subject to the further improvement by applying various corrections. We tested the module with a “conventional” analog ASIC readout as well as a wave-front sampling ASIC to compare the results, which is critical for the optimization of the future instrument.

A. A. Moiseev↗

Position-Sensitive Detector with GaAs photocathode and high time resolution

The Position-Sensitive Detector (PSD) on base of GaAs photocathode and microchannel plate set has been developed. PSD consists of thick semi-conductor photocathode with quantum efficiency about 48% in the range of 4000-7500 A, two micro-channel plates, and 16-electrode collector. The detector has spatial resolution of 20-40 microns for about 5{center_dot}10{sup 2} pixels, time resolution of 1 {mu}s and effective sensitivity up to 35%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Fundamental Quadrupole Band of (14)N2: Line Positions from High-Resolution Stratospheric Solar Absorption Spectra

The purpose of this note is to report accurate measurements of the positions of O- and S-branch lines of the (1-0) vibration-rotation quadrupole band of molecular nitrogen ((14)N2) and improved Dunham coefficients derived from a simultaneous least-squares analysis of these measurements and selected infrared and far infrared data taken from the literature. The new measurements have been derived from stratospheric solar occultation spectra recorded with Fourier transform spectrometer (FTS) instruments operated at unapodized spectral resolutions of 0.002 and 0.01 /cm. The motivation for the present investigation is the need for improved N2 line parameters for use in IR atmospheric remote sensing investigations. The S branch of the N2 (1-0) quadrupole band is ideal for calibrating the line-of-sight airmasses of atmospheric spectra since the strongest lines are well placed in an atmospheric window, their absorption is relatively insensitive to temperature and is moderately strong (typical line center depths of 10 to 50% in high-resolution ground-based solar spectra and in lower stratospheric solar occultation spectra), and the volume mixing ratio of nitrogen is constant in the atmosphere and well known. However, a recent investigation has'shown the need to improve the accuracies of the N2 fine positions, intensities, air-broadened half-widths, and their temperature dependences to fully exploit this calibration capability (1). The present investigation addresses the problem of improving the accuracy of the N2 line positions.

Rinsland, C. P.↗

High resolution tip-tilt positioning system for a next generation MLL-based x-ray microscope

Multilayer Laue lenses (MLLs) are x-ray focusing optics with the potential to focus hard x-rays down to a single nanometer level. In order to achieve point focus, an MLL microscope needs to have the capability to perform tip-tilt motion of MLL optics and to hold the angular position for an extended period of time. Here, we present a 2D tip-tilt system that can achieve an angular resolution of over 100 microdegree with a working range of 4°, by utilizing a combination of laser interferometer and mini retroreflector. The linear dimensions of the developed system are about 30 mm in all directions, and the thermal dissipation of the system during operation is negligible. Compact design and high angular resolution make the developed system suitable for MLL optics alignment in the next generation of MLL-based x-ray microscopes.

36 MATERIALS SCIENCE↗

Progress status for the Mu2e calorimeter system

The Mu2e experiment at FNAL aims to measure the charged-lepton flavor violating neutrinoless conversion of a negative muon into an electron. The conversion results in a monochromatic electron with an energy slightly below the muon rest mass (104.97 MeV). The calorimeter should confirm that the candidates reconstructed by the extremely precise tracker system are indeed conversion electrons while performing a powerful $\mu/e$ particle identification. Moreover, it should also provide a high level trigger for the experiment independently from the tracker system. The calorimeter should also be able to keep functionality in an environment where the background delivers a dose of ~ 10 krad/year in the hottest area and to work in the presence of 1 T axial magnetic field. These requirements translate in the design of a calorimeter with large acceptance, good energy resolution O(5%) and a reasonable position (time) resolution of ~<1 cm (<0.5ns). The baseline version of the calorimeter is composed by two disks of inner (outer) radius of 351 (660) mm filled by 1860 hexagonal $BaF_2$ crystals of 20 cm length. Each crystal is readout by two large area APD's. In this study, we summarize the experimental tests done so far as well as the simulation studies in the Mu2e environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gas-phase fragmentation studies of cyclic oligo-β-(1→6)-D-glucosamines by electrospray ionization mass spectrometry using a hybrid high-resolution mass spectrometer

Positive and negative ion high-resolution electrospray ionization mass spectra (MS and MS{sub 2}) of cyclooligo-β-(1→6)-D-glucosamines and cyclooligo-β-(1→6)-N-acetyl-D-glucosamines were acquired and interpret. It was shown that the cleavages of glycosidic bonds are the main processes in the decay of protonated and metallated molecules. In addition, elimination of the water molecules (and ammonia for cyclooligo-β-(1→6)-D-glucosamines) was observed along with other processes including the unknown skeletal rearrangement. A primary fragmentation of the negatively charged ions (deprotonated molecules) differed from that of the positively charged ones.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ambiguity resolution for satellite Doppler positioning systems

The implementation of satellite-based Doppler positioning systems frequently requires the recovery of transmitter position from a single pass of Doppler data. The least-squares approach to the problem yields conjugate solutions on either side of the satellite subtrack. It is important to develop a procedure for choosing the proper solution which is correct in a high percentage of cases. A test for ambiguity resolution which is the most powerful in the sense that it maximizes the probability of a correct decision is derived. When systematic error sources are properly included in the least-squares reduction process to yield an optimal solution the test reduces to choosing the solution which provides the smaller valuation of the least-squares loss function. When systematic error sources are ignored in the least-squares reduction, the most powerful test is a quadratic form comparison with the weighting matrix of the quadratic form obtained by computing the pseudoinverse of a reduced-rank square matrix. A formula for computing the power of the most powerful test is provided. Numerical examples are included in which the power of the test is computed for situations that are relevant to the design of a satellite-aided search and rescue system.

Argentiero, P.↗

Time-delay control of a magnetic levitated linear positioning system

In this paper, a high accuracy linear positioning system with a linear force actuator and magnetic levitation is proposed. By locating a permanently magnetized rod inside a current-carrying solenoid, the axial force is achieved by the boundary effect of magnet poles and utilized to power the linear motion, while the force for levitation is governed by Ampere's Law supplied with the same solenoid. With the levitation in a radial direction, there is hardly any friction between the rod and the solenoid. The high speed motion can hence be achieved. Besides, the axial force acting on the rod is a smooth function of rod position, so the system can provide nanometer resolution linear positioning to the molecule size. Since the force-position relation is highly nonlinear, and the mathematical model is derived according to some assumptions, such as the equivalent solenoid of the permanently magnetized rod, so there exists unknown dynamics in practical application. Thus 'robustness' is an important issue in controller design. Meanwhile the load effect reacts directly on the servo system without transmission elements, so the capability of 'disturbance rejection; is also required. With the above consideration, a time-delay control scheme is chosen and applied. By comparing the input-output relation and the mathematical model, the time-delay controller calculates an estimation of unmodeled dynamics and disturbances and then composes the desired compensation into the system. Effectiveness of the linear positioning system and control scheme are illustrated with simulation results.

Tarn, J. H.↗

Carrier phase ambiguity resolution for the Global Positioning System applied to geodetic baselines up to 2000 km

A technique for resolving the ambiguities in the GPS carrier phase data (which are biased by an integer number of cycles) is described which can be applied to geodetic baselines up to 2000 km in length and can be used with dual-frequency P code receivers. The results of such application demonstrated that a factor of 3 improvement in baseline accuracy could be obtained, giving centimeter-level agreement with coordinates inferred by very-long-baseline interferometry in the western United States. It was found that a method using pseudorange data is more reliable than one using ionospheric constraints for baselines longer than 200 km. It is recommended that future GPS networks have a wide spectrum of baseline lengths (ranging from baselines shorter than 100 km to those longer than 1000 km) and that GPS receivers be used which can acquire dual-frequency P code data.

Blewitt, Geoffrey↗