Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Dynamical Heating from Dark Compact Objects and Axion Minihalos: Implications for the 21-cm Signal

The temperature of baryons at the end of the cosmic dark ages can be inferred from observations of the 21-cm hyperfine transition in neutral hydrogen. Any energy injection from the dark sector can therefore be detected through these measurements. Dark compact objects and dark-matter substructures can modify the baryon temperature by transferring heat via dynamical friction. In this work, we evaluate the prospects for detecting dynamical friction-induced heating from dark compact objects with a mass in the range $10^2 M_{\odot}$ to $10^5 M_{\odot}$, as well as from axion minihalos, using upcoming 21-cm experiments. We find that both the 21-cm global signal and power-spectrum measurements will be sensitive to dark compact objects that constitute about 10% of the dark matter, and will substantially improve our sensitivity to axion-like particles with masses in the range $10^{-18}$ eV to $10^{-9}$ eV.

Bhalla, Badal [Oklahoma U.] (ORCID:000000030488664↗

Measurement-Based Quantum Thermal Machines with Feedback Control

We investigated coupled-qubit-based thermal machines powered by quantum measurements and feedback. We considered two different versions of the machine: (1) a quantum Maxwell’s demon, where the coupled-qubit system is connected to a detachable single shared bath, and (2) a measurement-assisted refrigerator, where the coupled-qubit system is in contact with a hot and cold bath. In the quantum Maxwell’s demon case, we discuss both discrete and continuous measurements. We found that the power output from a single qubit-based device can be improved by coupling it to the second qubit. We further found that the simultaneous measurement of both qubits can produce higher net heat extraction compared to two setups operated in parallel where only single-qubit measurements are performed. In the refrigerator case, we used continuous measurement and unitary operations to power the coupled-qubit-based refrigerator. We found that the cooling power of a refrigerator operated with swap operations can be enhanced by performing suitable measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

1.4.2.402 - Water Risk for the Bulk Power System: Asset to Grid Impacts

Utilities and stakeholders need a standardized mechanism for evaluating how future climate and hydrologic conditions translate to water-related risks for power grid assets and systems to support planning decisions. Yet, no such mechanism exists. To address this need, our goals are to: (1) Develop and execute a state-of-the-art multi-model framework to assess future climate-water impacts and risks to the grid, including sensitivities to varying hydrologic drivers and infrastructure scenarios. (2) Create a standardized interactive visualization platform, using data from the climate-water risk assessments, that enables stakeholders to evaluate climate-water impacts, risks, and adaptation measures for power systems.

bulk power system↗

Physics-based modeling and information-theoretic sensor and settings selection for tool wear detection in precision machining

Precision machining of metals is an energy intensive process with applications and impacts across the manufacturing industry. The energy efficiency, product yield, and maintenance of the precision machine require a digital twin that can assist with prognostics and health management. In this report a physics-based model is developed and validated against face milling data, and then used for the timely and precise inference of machining faults that cannot be measured directly. Computer numerical control (CNC) measurements of power and force are used through this physics-based machining model to predict deviations of the outputs of power consumption and cutting forces during normal operation. A model-based fault detection and isolation methodology is applied to determine the optimal (traditional and available) sensor suite and the test settings (admissible input values) that improve the inference of tool wear in face milling. The optimal sensor suite and input test settings are obtained by solving a mixed integer non-linear program that optimizes information-theoretic metrics relevant to the detection and isolation of tool wear from steady-state or transient machining measurements. Dynamic time warping and k—NN classification are then used to validate the robustness of the optimal design for fault detection test design, including the optimal sensor suite.

42 ENGINEERING↗

Enabling Seamless Integration of EV Charging Infrastructure with Weak Electric Grids

Widespread adoption of Electric Vehicles (EVs) for light, medium, and heavy-duty applications has gained significant interest. Based on ownership and user preferences, light duty and local delivery medium-duty EVs are typically connected to grid distribution networks whereas larger medium duty and heavy-duty EVs are typically connected to distribution or even sub-transmission networks. Challenges with at-scale EVs and charging infrastructure supporting them include interoperability, distribution network upgrades, surge in demand charges, power quality issues, voltage stability, etc. Based on real-world data, steady-state and dynamic assessments of light-duty EV charging with a focus on DC Fast Charging (DCFC) for weak distribution grids is presented. Three main areas of contributions in this paper include - steady state and dynamic power quality measurements and assessments using real world data, transient assessments of light duty EV integration with weak distribution networks (IEEE 13 node feeder system) under grid-connected and microgrid modes, and formulation of an intelligent charging decision algorithm to enable an impact-minimal charging.

actionable intelligence↗

Quantifying Dynamic On-State Resistance of GaN HEMTs for Power Converter Design via a Survey of Low and High Voltage Devices

Designing and optimizing high switching frequency, ultra-efficient converters requires detailed knowledge of the behavior and parasitic parameters for both active and passive components. Recently, wide bandgap transistors have enabled simultaneous increases in both switching frequency and efficiency due to higher maximum operating junction temperature limits, lower dc on-state resistances, and reduced parasitic inductances and capacitances. Yet, the early acceptance of gallium-nitride (GaN) switches was plagued by detrimental dynamic on-state resistance effects. This complex phenomenon for GaN devices is characterized by deviations in on-state resistance from dc operating characteristics based on design choices such as the magnitude and duration of both voltage and current stress, switching mode, and junction temperature. While device manufacturers have made improvements compared to early generation devices, experimental evidence from a survey of commercial GaN transistors highlight measurable change in on-state resistance still exists due to variations in voltage stress during hard-switching operation. After sharing insights for obtaining low noise measurements, an analysis method along with two metrics are proposed to characterize dynamic on-state resistance measurements for power electronics designers. Furthermore, quantifying the performance of GaN devices with standardized metrics facilitates a fair comparison between different GaN device technologies during converter development, enables manufacturing qualification for GaN switches, and provides a benchmark to catalyze improvement for the next generation of GaN device development.

14 SOLAR ENERGY↗

Bayesian High-Rank Hankel Matrix Completion for Nonlinear Synchrophasor Data Recovery

Phasor measurement units (PMUs) provide high temporal-resolution synchrophasor measurements for power system monitoring and control. The frequent data quality issues, such as missing and bad data, prevent the incorporation of synchrophasor data in real-time operations. Most existing data-driven data recovery methods assume the power system dynamics can be approximated by a linear dynamical system, and the recovery performance degrades significantly when the power system is experiencing nonlinear dynamics during significant events. Here, this paper proposes a data-driven Bayesian nonlinear synchrophasor data recovery method (Ba-NSDR) that can recover a consecutive time period of simultaneous data losses or errors across all channels, even when the underlying system is highly nonlinear. The idea is to lift the Hankel matrix of the spatial-temporal synchrophasor data to a higher dimension such that the lifted Hankel matrix is low-rank in that space and can be processed with the kernel trick. Our proposed Bayesian method then infers the probabilistic distributions of synchrophasor from the partial observations. Some distinctive features of Ba-NSDR include an uncertainty index to measure the accuracy of the recovery result and the robustness to parameter selections. Our method is verified on both synthetic and recorded event datasets.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Operational-based annual energy production uncertainty: are its components actually uncorrelated?

Calculations of annual energy production (AEP) from a wind power plant – whether based on preconstruction or operational data – are critical for wind plant financial transactions. The uncertainty in the AEP calculation is especially important in quantifying risk and is a key factor in determining financing terms. A popular industry practice is to assume that different uncertainty components within an AEP calculation are uncorrelated and can therefore be combined as the sum of their squares. We assess the practical validity of this assumption for operational-based uncertainty by performing operational AEP estimates for more than 470 wind plants in the United States, mostly in simple terrain. We apply a Monte Carlo approach to quantify uncertainty in five categories: revenue meter data, wind speed data, regression relationship between density-corrected wind speed (from reanalysis data) and measured wind power, length of long-term-correction data set, and future interannual variability. We identify correlations between categories by comparing the results across all 470 wind plants. We observe a positive correlation between interannual variability and the linearized long-term correction; a negative correlation between wind resource interannual variability and linear regression; and a positive correlation between reference wind speed uncertainty and linear regression. Then, we contrast total operational AEP uncertainty values calculated by omitting and considering correlations between the uncertainty components. We quantify that ignoring these correlations leads to an underestimation of total AEP uncertainty of, on average, 0.1% and as large as 0.5% for specific sites. Although these are not large increases, these would still impact wind plant financing rates; further, we expect these values to increase for wind plants in complex terrain. Based on these results, we conclude that correlations between the identified uncertainty components should be considered when computing the total AEP uncertainty.

17 WIND ENERGY↗

Testing Scale-Dependent Modified Gravity with DESI DR1

The Dark Energy Spectroscopic Instrument (DESI) provides an unprecedented opportunity to test deviations from general relativity (GR) that introduce a new physical scale within its redshift range. Using the connection between a Yukawa-like potential and the Hu-Sawicki $f(R)$ model, we place strong constraints on the range of a hypothetical fifth force mediated by a massive scalar field. We analyze the power spectrum measurements from DESI Data Release 1 using a baseline EFT model that employs the fkpt approach for the loop integrals. We find no evidence for deviations from GR and obtain the constraint $\log_{10} |f_{R_0}| < -4.59$ (95% C.L.). This corresponds to an upper bound at redshift zero on the scale at which corrections to GR become important, $λ< 17.81$ Mpc, or equivalently, a lower bound on the mass of the additional gravitational mediator of $m_ϕ> 3.60 \times 10^{-31}$ eV. We find that the modified gravity parameter $f_{R_0}$ is largely orthogonal to the cosmological parameters in the model, such that no additional projection effects relative to the GR case are introduced in this Full-Shape analysis. Furthermore, a second modified gravity parameter, the power index $n$, which modulates the time-variation of the associated mass, is found to be consistent with previous analyses that fixed it to unity. Adding DESI BAO data or other cosmological probes does not significantly change these results. The conclusions remain similar if the background evolution is described by evolving dark energy instead of a cosmological constant. Additionally, we test the robustness of the baseline model by varying the maximum wavenumber used in the Full-Shape analysis and analyzing the DESI targets separately. Finally, we analyze the degeneracies between the modified-gravity parameters and the sum of neutrino masses.

Gonzalez, D. [Guanajuato U.; UNAM, CCF] (ORCID:000↗

Numerical discreteness errors in multispecies cosmological N -body simulations

ABSTRACT We present a detailed analysis of numerical discreteness errors in two-species, gravity-only, cosmological simulations using the density power spectrum as a diagnostic probe. In a simple set-up where both species are initialized with the same total matter transfer function, biased growth of power forms on small scales when the solver force resolution is finer than the mean interparticle separation. The artificial bias is more severe when individual density and velocity transfer functions are applied. In particular, significant large-scale offsets in power are measured between simulations with conventional offset grid initial conditions when compared against converged high-resolution results where the force resolution scale is matched to the interparticle separation. These offsets persist even when the cosmology is chosen so that the two particle species have the same mass, indicating that the error is sourced from discreteness in the total matter field as opposed to unequal particle mass. We further investigate two mitigation strategies to address discreteness errors: the frozen potential method and softened interspecies short-range forces. The former evolves particles under the approximately ‘frozen’ total matter potential in linear theory at early times, while the latter filters cross-species gravitational interactions on small scales in low-density regions. By modelling closer to the continuum limit, both mitigation strategies demonstrate considerable reductions in large-scale power spectrum offsets.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimizing foreground mitigation for CMB lensing with combined multifrequency and geometric methods

Here, a key challenge for current and upcoming cosmic microwave background lensing measurements is their sensitivity to biases from extragalactic foregrounds, such as Sunyaev-Zel'dovich signals or cosmic infrared background emission. Several methods have been developed to mitigate these lensing foreground biases, dividing broadly into multifrequency cleaning approaches and modifications to the estimator geometry, but how to optimally combine these methods has not yet been explored in detail. In this paper, we examine which combination of lensing foreground mitigation strategies is best able to reduce the impact of foreground contamination for a Simons Observatory-like experiment while preserving maximal signal-to-noise. Although the optimal combination obtained depends on whether bias reduction or variance reduction is prioritized and on whether polarization data is used, generally, we find that combinations involving both geometric (profile hardening, source hardening, or shear) and multifrequency (symmetric cleaning) methods perform best. For lensing power spectrum measurements from temperature (polarization and temperature), our combined estimator methods are able to reduce the bias below σ/4 or 0.3% (0.1%), a factor of 16 (30) lower than the standard quadratic estimator bias, at a modest signal-to-noise cost of only 18% (12%). In contrast, single-method foreground-mitigation approaches struggle to reduce the bias to a negligible level below σ/2 without incurring a large noise penalty. For upcoming and current experiments, our combined methods therefore represent a promising approach for making lensing measurements with negligible foreground bias.

79 ASTRONOMY AND ASTROPHYSICS↗

Limits on clustering and smooth quintessence from the EFTofLSS

We apply the Effective Field Theory of Large-Scale Structure (EFTofLSS) to analyze cosmological models with clustering quintessence, which allows us to consistently describe the parameter region in which the quintessence equation of state w < -1. First, we extend the description of biased tracers in redshift space to the presence of clustering quintessence, and compute the one-loop power spectrum. We solve the EFTofLSS equations using the exact time dependence, which is relevant to obtain unbiased constraints. Then, fitting the full shape of BOSS pre-reconstructed power spectrum measurements, the BOSS post-reconstruction BAO measurements, BAO measurements from 6DF/MGS and eBOSS, the Supernovae from Pantheon, and a prior from BBN, we bound the clustering quintessence equation of state parameter w = -1.011 -0.048 +0.053 at 68% C.L. Further combining with Planck, we obtain w = -1.028 -0.030 +0.037 at 68% C.L. We also obtain constraints on smooth quintessence, in the physical regime w ≥ -1: combining all datasets, we get -1 ≤ w < -0.979 at 68% C.L. These results strongly support a cosmological constant.

79 ASTRONOMY AND ASTROPHYSICS↗

Securing Inverter Communication: Proactive Intrusion Detection and Mitigation System to Tap, Analyze, and Act

The electric grid has undergone rapid, revolutionary changes in recent years; from the addition of advanced smart technologies to the growing penetration of distributed energy resources (DERs) to increased interconnectivity and communications. However, these added communications, access interfaces, and third-party software to enable autonomous control schemes and interconnectivity also expand the attack surface of the grid. To address the gap of DER cybersecurity and secure the grid-edge to motivate a holistic, defense-in-depth approach, a proactive intrusion detection and mitigation system (PIDMS) device was developed to secure PV smart inverter communications. The PIDMS was developed as a distributed, flexible bump-in-the-wire (BITW) solution for protecting PV smart inverter communications. Both cyber (network traffic) and physical (power system measurements) are processed using network intrusion monitoring tools and custom machinelearning algorithms for deep packet analysis and cyber-physical event correlation. The PIDMS not only detects abnormal events but also deploys mitigations to limit or eliminate system impact; the PIDMS communicates with peer PIDMSs at different locations using the MQTT protocol for increased situational awareness and alerting. The details of the PIDMS methodology and prototype development are detailed in this report as well as the evaluation results within a cyber-physical emulation environment and subsequent industry feedback.

14 SOLAR ENERGY↗

How Much Attenuation Extinguishes mm-Wave Vertically Pointing Radar Return Signals?

Vertically pointing radars (VPRs) operating at millimeter wavelengths measure the power return from raindrops enabling precipitation retrievals as a function of height. However, as the rain rate increases, there are combinations of rain rate and rain path length that produce sufficient attenuation to prevent the radar from detecting raindrops all the way through rain shafts. This study explores the question: Which rain rate and path length combinations completely extinguish radar return signals for VPRs operating between 3 and 200 GHz? An important step in these simulations is converting attenuated radar reflectivity factor into radar received signal-to-noise ratio (SNR) in order to determine the range where the SNR drops below the receiver detection threshold. Configuring the simulations to mimic a U.S. Department of Energy Atmospheric Radiation Mission (ARM) W-band (95 GHz) radar deployed in Brazil, the simulation results indicate that a W-band radar could observe raindrops above 3.5 km only when the rain rate was less than approximately 4 mm h -1 . The deployed W-band radar measurements confirm the simulation results with maximum observed heights ranging between 3 and 4.5 km when a surface disdrometer measured 4 mm h -1 rain rate (based on 25-to-75 percentiles from over 25,000 W-band radar profiles). In summary, this study contributes to our understanding of how rain and atmospheric gas attenuation impacts the performance of millimeter-wave VPRs and will help with the design and configuration of multi-frequency VPRs deployed in future field campaigns.

54 ENVIRONMENTAL SCIENCES↗

Sensor Drift Estimation for Reactor Systems by Fusing Multiple Sensor Measurements

A nuclear power plant is instrumented with a variety of sensors that monitor its variables to estimate the state and initiate safety actions, if needed. We address the problem of estimating drifts or errors in sensor measurements due to factors such as calibration changes. We propose an information fusion method that uses measurements from other sensors to generate an estimate of a sensor measurement, and its difference from an actual measurement provides an error estimate. We present two fusers based on the ensemble of trees and support vector machine that are trained using sensor measurements collected at an emulated test loop of a pressurized water reactor under no-drift conditions. We present error estimates for a differential pressure sensor of the heat exchanger of the primary coolant system, under twenty controlled scenarios using the test loop. Both positive and negative errors are captured by both methods in scenarios involving calibration drifts, blocking, air gap and electromagnetic interference. The root mean square errors of estimated drifts are typically within 2% percent of the maximum.

Rao, Nageswara↗

Optimizing LSST observing strategy for weak lensing systematics

ABSTRACT The Legacy Survey of Space and Time (LSST) survey will provide unprecedented statistical power for measurements of dark energy. Consequently, controlling systematic uncertainties is becoming more important than ever. The LSST observing strategy will affect the statistical uncertainty and systematics control for many science cases; here, we focus on weak lensing (WL) systematics. The fact that the LSST observing strategy involves hundreds of visits to the same sky area provides new opportunities for systematics mitigation. We explore these opportunities by testing how different dithering strategies (pointing offsets and rotational angle of the camera in different exposures) affect additive WL shear systematics on a baseline operational simulation, using the ρ-statistics formalism. Some dithering strategies improve systematics control at the end of the survey by a factor of up to ∼3–4 better than others. We find that a random translational dithering strategy, applied with random rotational dithering at every filter change, is the most effective of those strategies tested in this work at averaging down systematics. Adopting this dithering algorithm, we explore the effect of varying the area of the survey footprint, exposure time, number of exposures in a visit, and exposure to the Galactic plane. We find that any change that increases the average number of exposures (in filters relevant to WL) reduces the additive shear systematics. Some ways to achieve this increase may not be favorable for the WL statistical constraining power or for other probes, and we explore the relative trade-offs between these options given constraints on the overall survey parameters.

79 ASTRONOMY AND ASTROPHYSICS↗

Hybrid Power Plants for Energy Resilience: A Case Study

As renewable energy technologies are increasingly adopted, they pose an opportunity to improve the sustainability and resilience of distributed grids, especially when their design and operation is coordinated as a hybrid power plant. When included in hybrid power plants, distributed wind turbines in particular have the potential to enhance the resilience of distributed grids in areas with good wind resource, due to their ability to provide more consistent generation and ancillary services as compared to photo-voltaic (PV) solar panels. Despite this benefit, U.S. distributed wind adoption is lower than other comparable renewable energy technologies. In this study, we seek to demonstrate how hybrid power plants that include distributed wind turbines can contribute to distribution grid resilience by meeting loads (especially critical loads) more consistently, increasing reserve capacity, and providing value to customers during outages. To demonstrate these contributions, we integrate three separate frameworks and apply them to a case study in a rural electric cooperative in Iowa. Through this case study, we simulate and compare hybrid power plant design and operation during two hazard events: a tornado that causes a 48-hour distribution outage and a winter weather event that causes a 6-hour generation outage. The inclusion of a hybrid power plant that leverages 1) increased battery duration and 2) advanced forecasting and dispatch strategies that reserve capacity leading up to a hazard event best reduce lost loads as well as diesel consumption that would otherwise be used to meet those loads during short- and long-duration hazard events. Depending on the hybrid power plant capacity and operation, we find that the outage mitigation value of a hybrid power plant (measured in value to customers to avoid an outage and avoided lost revenues for the utility) is significant in both hazard events; adding wind, solar, and battery assets to the existing system adds about $50-$100M in avoided lost load and at least $4-$8k in utility value in the tornado hazard event, and $570k-$2.2M in avoided lost load and at least $220-$650 in utility value in the winter hazard scenario. In both the tornado and winter hazard scenarios, optimizing the operation of the hybrid system for resilience can lend similar value as increasing battery duration by 5 MWh for the lower capacity systems considered.

17 WIND ENERGY↗

Cool rooms for indoor heat resilience: Evaluating affordable cooling strategies in heat-stressed California homes

Extreme heat conditions pose significant indoor survivability challenges for resource-constrained communities, which often lack access to cooling, have poorly insulated homes, and face compounding socioeconomic vulnerabilities. Moreover, concurrent power outages worsen health risks and heat-related illnesses. It is therefore crucial to develop innovative and affordable cooling approaches to protect vulnerable populations. This study assesses the efficacy of “cool rooms”– a designated space within a home equipped with passive and low-power active cooling measures to maintain safe indoor temperatures during extreme heat events and power disruptions. Using a physics-based building energy modeling approach, we evaluate the efficacy of various retrofit packages in maintaining thermal safety within the cool room under recent extreme heat conditions. The results indicate that passive measures can reduce 64% of hours with unmet standard effective temperatures, while the combination of passive and low-power active measures with built-in batteries further cuts this to 86%. Nevertheless, these strategies remain insufficient to maintain indoor thermal safety during extended outages. In contrast, integrating a solar-powered mini-split heat pump, whose technical potential was evaluated in this study, reduces indoor air temperatures below the 28 °C overheating threshold and significantly improves indoor habitability. The localized cool room strategy also offers potential for grid resilience by reducing peak electricity demand by up to 70% compared to whole house cooling during heat waves. The findings can inform the development of actionable heat mitigation plans and retrofit policies for residential communities with relatively low adoption of air conditioning such as warm marine climates.

Cool room↗