Development and Preliminary Experiments on a Uniform Field Test fixture for Power Flow Experiments
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
This paper describes the results of a laboratory investigation to evaluate the technical performance of advanced power strip (APS) devices when subjected to a range of home entertainment center and home office usage scenarios.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Abstract not provided.
This report presents results of research performed by Idaho National Laboratory (INL) for the Nuclear Regulatory Commission (NRC) to identify and develop strategies for testing nuclear power plant (NPP) flood barriers. This research project began with a literature review that documented the results of previous NRC-funded research, work performed by other government agencies, reports generated by industry organizations, NRC licensee submittals, information from testing facilities, and information from commercial firms engaged in NPP decommissioning. This literature review was then used to develop a simplified flood protection categorization scheme and related glossaries. Using this categorization scheme and glossaries, a survey of currently used flood barriers was conducted, focusing on both permanent and temporary flood barriers. External flood barriers such as levees and berms were outside the scope of this survey. This research project also assessed the current state of NPP decommissioning for potential flood barrier harvesting opportunities, surveyed capabilities of domestic and international flood testing facilities, and explored technical challenges to harvesting and testing of flood barriers. Other factors that should be considered in developing flood barrier testing strategies were also explored and are documented in this report (e.g., selection of flood barriers for testing, codes and standards for flood barrier testing, potential alternatives to harvesting such as in-situ testing, testing performance criteria, and testing parameters).
This fact sheet describes the 2024 Competitiveness Improvement Project (CIP) award received by Pecos Wind Power for Prototype Installation and Testing. The U.S. Department of Energy's (DOE's) CIP awards cost-shared subcontracts and technical support to manufacturers of small and medium-sized wind turbines. Managed by NREL on behalf of DOE's Wind Energy Technologies Office, CIP helps advance wind energy as a cost-effective, distributed generation technology option.
We test the sensitivity of neutrino parameter constraints from combinations of CMB and LSS data sets to the assumed form of the primordial power spectrum (PPS) using Bayesian model selection. Significantly, none of the tested combinations, including recent high-precision local measurements of H{sub 0} and cluster abundances, indicate a signal for massive neutrinos or extra relativistic degrees of freedom. For PPS models with a large, but fixed number of degrees of freedom, neutrino parameter constraints do not change significantly if the location of any features in the PPS are allowed to vary, although neutrino constraints are more sensitive to PPS features if they are known a priori to exist at fixed intervals in log k . Although there is no support for a non-standard neutrino sector from constraints on both neutrino mass and relativistic energy density, we see surprisingly strong evidence for features in the PPS when it is constrained with data from Planck 2015, SZ cluster counts, and recent high-precision local measurements of H{sub 0}. Conversely combining Planck with matter power spectrum and BAO measurements yields a much weaker constraint. Given that this result is sensitive to the choice of data this tension between SZ cluster counts, Planck and H{sub 0} measurements is likely an indication of unmodeled systematic bias that mimics PPS features, rather than new physics in the PPS or neutrino sector.
Fast simultaneous feasibility testing (SFT) for management of an electrical power grid is achieved through various innovations. The computation problem relates to evaluation of candidate solutions for external power flows into a power grid, with respect to predetermined constraints and contingencies. Storage and computations are reduced by formulating the problem in terms of transactional nodes (e.g. third party connections for generators and loads) instead of the larger number of bus nodes. Further advantages are achieved by precomputing matrices that can be reused across multiple SFT invocations, organizing matrices and operations to reduce storage and computation, and eliminating branches that have no contingency violations. The fast SFT further enables new applications for integrating SFT with a Security-Constrained Unit Commitment (SCUC) optimizer for efficient single pass solutions; operating SFT as a service to multiple SCUC solvers; or integration with Security-Constrained Economic Dispatch (SCED) optimization.
We report that the neutronics software, HELIOS, was validated in 2015 for performing core reload design and safety analysis of the Advanced Test Reactor. However, when HELIOS was benchmarked against historic fission-wire measurements (i.e., zero-power full-core measurements) a statistically resolved calculation-to-measurement bias was discovered. The azimuthal power along each fuel plate computed by HELIOS has consistently shown to under-predict measurements made by fission-wires in historic zero-power tests near the fuel element side-plates. It was hypothesized during the HELIOS software validation work, that this bias is attributable to local moderation in coolant vents in the side-plates axially just above and below the fission-wires on the fuel-plate edges. This work used detailed MCNP and MC21 models of the side-plate vents to test this hypothesis. By comparing the average azimuthal biases between HELIOS, and 2D and 3D MCNP models, and a 3D MC21 model, it was found that the HELIOS azimuthal bias is not due to the measurement.
Power hardware-in-the-loop (PHIL) has emerged as a leading strategy to thoroughly assess the impact of proprietary inverter controls on a specific power system. The development of a PHIL test bed typically involves an inverter under test, a power amplifier, controllable DC supply, and a digital real-time simulator (DRTS) to simulate the power system under study. As a result of PHIL nonidealities, a form of digital compensation within the DRTS is used, which is commonly referred to as a PHIL interface. Many existing methods use legacy power amplifiers that do not contain internal voltage regulation. These existing interface methods are based around a voltage regulator within the DRTS and do not consider the interaction with the controls in newer amplifiers. In this study, a three-step approach of PHIL interface development for modern power amplifiers with built-in voltage regulation is introduced and is validated in hardware with a 30-kW grid-following inverter.
In the wake of the Fukushima Daiichi nuclear power plant accident in 2011, the accident tolerant fuels (ATF) program was initiated to enhance the safety of light-water reactor fuels, placing significant emphasis on cladding. A crucial step for the broad implementation of ATF in commercial reactors involves irradiation testing of the fuel designs. ATF-2D, the latest experiment in the ATF series, is slated to undergo irradiation in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). ATF-2D is a joint effort of the INL with industry partners General Electric Global Research; Framatome; General Atomics; the Japan Atomic Energy Agency; Hitachi-GE Nuclear Energy, Ltd; Global Nuclear Fuel-Japan Co., Ltd; Nippon Nuclear Fuel Development Co., Ltd; and Mitsubishi Heavy Industries, Ltd. The ATF-2D test train design consists of four tiers, each housing six rodlets. The device will be inserted in Loop 2A within the central flux trap of the ATR, and is anticipated to undergo irradiation throughout three 60-day cycles. Typical pressurized water reactor conditions will be emulated during the irradiation. The objective of the work presented here is to dimension neutron-absorbing hafnium (Hf) components surrounding the fuel rodlets, such that the axial power profile is flattened, while simultaneously ensuring that the total fission power output of the entire test train remains below 200 kW.
In the wake of the Fukushima Daiichi nuclear power plant accident in 2011, the accident tolerant fuels (ATF) program was initiated to enhance the safety of light-water reactor fuels, placing significant emphasis on cladding. A crucial step for the broad implementation of ATF in commercial reactors involves irradiation testing of the fuel designs. ATF-2D, the latest experiment in the ATF series, is slated to undergo irradiation in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). ATF-2D is a joint effort of the INL with industry partners General Electric Global Research; Framatome; General Atomics; the Japan Atomic Energy Agency; Hitachi-GE Nuclear Energy, Ltd; Global Nuclear Fuel-Japan Co., Ltd; Nippon Nuclear Fuel Development Co., Ltd; and Mitsubishi Heavy Industries, Ltd. The ATF-2D test train design consists of four tiers, each housing six rodlets. The device will be inserted in Loop 2A within the central flux trap of the ATR, and is anticipated to undergo irradiation throughout three 60-day cycles. Typical pressurized water reactor conditions will be emulated during the irradiation. The objective of the work presented here is to dimension neutron-absorbing hafnium (Hf) components surrounding the fuel rodlets, such that the axial power profile is flattened, while simultaneously ensuring that the total fission power output of the entire test train remains below 200 kW.
In the experiment entitled “Initial Testing of Wave Energy Powered UV-C LED Anti-Biofouling System,” a UV-C LED was used to treat platinum-coated titanium coupons emulating CTD electrode material. An additional control set of coupons were exposed to seawater without the LED treatment. The experimental setup was deployed in seawater tanks at PNNL-Sequim’s Marine and Coastal Research Laboratory (MCRL) for the duration of six months. Tank seawater temperature data were collected for the duration of the experimental campaign. At two-month intervals triplicate sets of coupons were removed from both treatment and control test chambers and weighed to characterize biomass accumulation. After weighing, the coupons were photographed in initial condition, with a stain applied to highlight biofouling growth, and after rinsing off excess stain. These photographs were analyzed using PNNL’s Biofouling Growth Index (BGI) software and with a calculation of percentage dark pixels after conversion to grayscale. Additionally, at the final 6-month datapoint triplicate sets of control and test coupons were sent to PNNL-Richland’s Environmental Molecular Sciences Laboratory (EMSL) for scanning electron microscopy. All data organization and collection methods are described in further detail in the document “TEAMER_3newable_Data_Guide.pdf.” Biomass accumulation increased over time on both sets of coupons, and percent area biofouled demonstrated a similar trend. Analysis of the collected data resulted in the findings that treatment method has an impact on biofouling growth, though to a much less significant extent than time does. Additionally, qualitative findings included the presence of advanced life forms such as worms in the control test chamber, but not in the treated test chamber.
The purpose of these Guidelines is to provide direction for conducting performance acceptance testing for large power tower solar systems that can yield results of a high level of accuracy consistent with good engineering knowledge and practice. The recommendations have been developed under a National Renewable Energy Laboratory (NREL) subcontract and reviewed by stakeholders representing concerned organizations and interests throughout the concentrating solar power (CSP) community. An earlier NREL report provided similar guidelines for parabolic trough systems. These Guidelines recommend certain methods, instrumentation, equipment operating requirements, and calculation methods. When tests are run in accordance with these Guidelines, we expect that the test results will yield a valid indication of the actual performance of the tested equipment. But these are only recommendations--to be carefully considered by the contractual parties involved in the Acceptance Tests--and we expect that modifications may be required to fit the particular characteristics of a specific project.
With increasing popularity of sustainable energy resources, research on power electronic-based renewable generation modeling is gaining impetus to enhance reliability of electric grids with high penetrations of renewable energy. A set of generic and public models for renewable energy are available in commercial positive sequence power system simulation software. However, advanced controller models applicable for renewable resources are typically not included in these tools. To ensure the integrity of the newly developed controller models for renewables in positive sequence simulators for large power systems, it is necessary to validate the dynamic performance of the proposed model with detailed electromagnetic models. This paper creates an equivalent test bed in PSCAD and PSLF for validating the performance of advanced controllers associated with renewable energy sources. To demonstrate the usefulness of the test-bed, a user-defined synthetic inertia (SI) controller model was developed in PSLF and validated through the proposed test bed.