FINAL TECHNICAL AND ECONOMIC FEASIBILITY STUDY ON THE APPLICATION OF A HEAT INTEGRATED POST-COMBUSTION CO2 CAPTURE SYSTEM WITH HITACHI ADVANCED SOLVENT INTO EXISTING COAL-FIRED POWER PLANT

This report contains the results of a techno-economic assessment (TEA) conducted of a heat integrated post-combustion CO2 capture process with Hitachi advanced solvent for retrofit into an existing coal-fired power plant (but treated as greenfield plant on cost analysis). The process has been developed by the University of Kentucky Center for Applied Energy (UK CAER). EPRI was chiefly responsible for this analysis, with significant input from WorleyParsons, Hitachi Power Systems America (Hitachi) and UK CAER. The project also involves the design, fabrication, installation, testing, and analyses of a slipstream facility located at L&GE-KU’s E.W. Brown Generating Station to demonstrate the UK CAER carbon capture system that could utilize heat integration with the main power plant. The design, start-up, and baseline of the pilot system was performed with a generic 30 wt% MEA solvent to obtain data for direct comparison with the DOE/NETL Reference Case followed by testing Hitachi’s proprietary solvent H3-1. In this techno-economic analysis, two cases utilizing the UK CAER process are compared, using different approach temperatures and solvent, against the DOE/NETL Reference Case (Case 10). The results are shown comparing the energy demand for post-combustion CO2 capture and the net higher heating value (HHV) efficiency of the power plant integrated with the post-combustion capture (PCC) plant. A levelized cost of electricity (LCOE) assessment was performed showing the costs of the options presented in the study. The key factors contributing to the reduction of LCOE were identified as CO2 partial pressure increase at the flue gas inlet, thermal integration of the process, and performance of the Hitachi H3-1 solvent. Recent UK CAER process pilot-scale testing data and process simualtion data showed that the packing heights of absorber and stripper columns were significantly oversized in the prelimanary TEA (Task 2 of this project) and thus updated in this final TEA for the H3-1 case only. In addition, the solvent make-up cost for H3-1 was updated based on lattest test results. Finally, a heat integration with the main power plant was applied in this final TEA to increase overall energy effciency for both the MEA and H3-1 cases. Additonal reductions in capital and operational costs are expected but not taken into account here. Shorter columns result in reduced pressure drops, smaller blower head and pump hydraulic head requirements. An increase in overall energy efficiency resuls in a decreased size of the power plant, the CCS and a reduced parasitic steam requirement to the CCS. The net efficiency of the UK CAER integrated PC power plant with CO2 capture changes from 26.2% for the Reference Case 10 plant in 2010 revised DOE/NETL baseline report to 27.6% for the MEA options considered, and 29.1% for the options utilizing the Hitachi advanced solvent. The UK CAER Process + Hitachi case also produces an extra 30.9 MW of generation compared to the UK CAER Process + MEA case and total 60.9 MW more than DOE Case 10. LCOE ($/MWh) values are $172.08/MWh for the MEA option and $157.65/MWh for the Hitachi H3-1 solvent cases considered in comparison to $189.59/MWh in January 2012 dollar for the Reference Case 10. The UK CAER CCS process with MEA case lowers energy consumption for CO2 capture to 1340 Btu/lb-CO2 captured as compared to 1540 Btu/lb-CO2 in the Reference Case 10. The UK CAER CCS process with H3-1 case further lowers energy consumption for CO2 capture to 973 Btu/lb-CO2 captured, for an advantage of 36.8% less energy consumption than Case 10. The study also shows 38.1% less heat rejection associated with the carbon capture system from 3398 MBtu/hr (Case 10) to 2104 MBtu/hr for the UK CAER + MEA system. Heat rejection is reduced to 2464 MBtu/hr in the UK CAER + H3-1 case, for a 27.5 % decrease compared to Case 10. Modeling outputs show that in the UK CAER process, the cooling water that is 2-5°C cooler than conventional cooling tower water can be achieved for ambient conditions common to the midwest and other regions. The results from the techno-economic assessment show that the proposed technology can be investigated further as a viable alternative to conventional CO2 capture technology. The evaluation also shows the effect of the critical parameters on the LCOE, with the main variables being the approach temperature and CO2 partial pressure increase at the flue gas inlet. A summary of the key advantages of the UK CAER Process + H3-1 case for LCOE and other economic factors compared to the DOE Case 10 is as follows: • A lower variable operating cost by $1.56/MWh ($1.08MWh less than the UK CAER Process + MEA Case), a 11.7% reduction compared to the DOE Case 10 • A lower COE by $25.32MWh ($13.94/MWh lower than the UK CAER Process + MEA Case), a 16.9% reduction compared to the DOE Case 10 • A lower LCOE by $31.94/MWh ($17.51/MWh lower than the UK CAER Process + MEA Case), a 16.9% reduction compared to the DOE Case 10 • A lower cost of CO2 captured by $18.65/tonne CO2 ($9.44/tonne CO2 lower than the UK CAER Process + MEA Case), a 30.4% reduction compared to the DOE Case 10 • A lower cost of CO2 avoided by $34.95/tonne CO2 ($18.53 tonne CO2 lower than the UK CAER Process + MEA Case), a 38.7% reduction compared to the DOE Case 10

Bhown, Abhoyjit S.↗

Electrolyzers in the System Advisor Model (SAM): A Techno-Economic Potential Study

A technoeconomic analysis of grid to low temperature electrolysis (Grid-LTE), photovoltaic to low temperature electrolysis (PV-LTE), concentrating solar power to high temperature electrolysis (CSP-HTSE) and a concentrating solar power with PV to high temperature electrolysis (CSP-PV-HTSE) centralized hydrogen production systems are analyzed to assess the economics of system and to provide a baseline for comparing these technologies against hydrogen production cost targets. A framework integrating the system advisor model (SAM) and US Department of Energy hydrogen production models (H2A) is developed to assess these systems. The hydrogen levelized cost given current and future assumptions for technology cost and performance is evaluated at optimal system configurations. The framework described in this report integrates SAM with H2A electrolyzer technologies and provides analysts a detailed technoeconomic method to analyze concentrating and photovoltaic solar technologies to produce energy that are directly coupled to LTE and HTSEs that use that energy to split water into hydrogen and oxygen. The baseline hydrogen levelized cost (HLCs) for the GRID-LTE, PV-LTE, CSP-HTSE, and CSP-PV-HTSE systems in Daggett, CA are 2.82, 3.86, 3.68, and 2.90 $\$$USD 2016/kg H2 and 2.50, 2.13, 2.84, 2.15 $\$$USD 2016/kg H2 in the 2020 and 2050 scenarios respectively. To achieve the $\$$2/kg H2 target in locations with excellent solar resources, cost parameters values aligned with aggressive R&D targets will need to be achieved for all the systems configurations. In Daggett, PV costs of $\$$0.68 /Wac or moderate ATB PV CAPEX projections result in HLCs of $\$$2 /kg H2. Similarly for PV-MSALT-HTSE systems, $\$$0.60 /Wac result in $\$$2/kg H2. For the MSALT-HTSE systems, better than aggressive 2050 ATB salt tower CAPEX projections would be needed to reach $\$$2/kg H2. Molten salt tower capital costs of $\$$2400/kW would enable $\$$2/kg H2 in 2050.

08 HYDROGEN↗

Expansion of Hazards and Probabilistic Risk Assessments of a Light-Water Reactor Coupled with Electrolysis Hydrogen Production Plants

This report builds upon the body of work sponsored by the Department of Energy (DOE) Light-Water Reactor Sustainability (LWRS) Flexible Power Operation and Generation (FPOG) program that presented generic probabilistic risk assessments (PRAs) for the addition of a heat extraction system (HES) to light-water reactors to support the co-location of a high temperature hydrogen electrolysis facility (HTEF). Probabilistic and deterministic hazards assessments and risk analyses are leveraged throughout this report. Several improvements and new analyses are included in this report. First, higher amounts of detail in the specifications of the generic HTEFs are used to produce scaled results for a 100, 500, and 1000 MW nominal hydrogen production facility. An additional hazard assessment of 1000 kg of hydrogen storage is performed. The facility hazards and footprint are assessed to determine the safe distance required for placement near the nuclear power plant (NPP). Second, specific designs for corresponding HESs for the different levels of support required by the HTEFs are analyzed in the PRA model. Third, a hazards analysis of the specified HTEFs leads not only to effects of the quantified risk assessment for the NPP, but also qualitative hazards assessment for the community. Finally, a seismic analysis and a high winds analysis have each been added to the PRA. The results investigate the applicability of the potential licensing approaches which do not require a full United States (U.S.) Nuclear Regulatory Commission (NRC) licensing review. The PRAs are generic and include listed assumptions. The HTEF design built for this project has further eliminated many conservative assumptions from the prior PRAs in this series. The PRA results indicate that the 10 CFR 50.59 licensing approach is justified due to the minimal increase in initiating event frequencies for all design basis accidents, with none exceeding 7.7%. The PRA results for core damage frequency and large early release frequency support the use of NRC Regulation Guide 1.174 as further risk information that supports a change without a full licensing amendment review. The hazard analyses and PRA confirm the need for engineered blast barriers of storage tanks and the common production header leaving the HTEF. The hazards analyses and PRA also confirm with high confidence that using the assumptions of design in this report that the safety case for licensing an HES addition and an HTEF sited with its unprotected high-pressure stage components 187 meters from the NPP’s transmission towers (the most fragile structure, system, and component) is strong.

08 HYDROGEN↗

FEED Study of Carbon Capture Inc. DAC and CarbonCure Utilization Using United States Steel's Gary Works Waste Plant

Direct Air Capture (DAC) has been proposed as a means of reducing atmospheric concentrations of CO2. While DAC has been evaluated through lab-scale, bench-scale, and small-scale pilot units, large-scale deployment has not been achieved. Feasibility studies are one tool to understand the potential design, operation, performance, and impact of commercial-scale DAC. This paper presents the results of a feasibility study for a passive DAC system deployed at >100,000 tpy scale in three different regions across the U.S. and awarded to Carbon Collect by the U.S. Department of Energy National Energy Technology Laboratory (DOE NETL). The MechanicalTree™technology has been designed and engineered by Carbon Collect based on the concept initially developed at Arizona State University Center for Negative Carbon Emissions. It uses a tower of stacked, sorbentcontaining disks supported by a lifting mechanism, exposed to the air to capture CO2 during the adsorption phase. The disks are then lowered into a regeneration chamber for vacuum and steam regeneration to produce CO2 product during the desorption step. The modular tree design allows large installations with repeatable, mass-manufactured units connected to common utilities such as steam supply, vacuum, and CO2 processing for compression and geologic storage. The passive DAC system eliminates the equipment and energy of forced air fans by using natural air circulation to contact the sorbent with the CO2 in the air. Because of this, the performance is dependent on the wind speed in addition to the temperature and relative humidity. Performance and flow rate fluctuations were incorporated into equipment and facility design with considerations for turndown to 10% of maximum rated flow to allow operation in all seasons. The feasibility study was undertaken to evaluate the technology in different regions and climates. Three locations were selected for this study representing different climates: Alabama (hot and humid), California (hot and arid), and Wyoming (continental). For each region, the adsorption/desorption cycle was optimized including tuning the heat integration and cycle timings. The performance of individual trees was then scaled to the full facility with the same design of more than 20,000 trees common between all regions. The installations had expected average CO2 capture rates of between 330,000 and 485,000 tonnes of CO2 per year depending on the climate. The initial engineering design for the facility at each location was performed with cost and performance estimates for the trees, carbon purification and compression, and the balance of plant. To supply thermal and electrical energy for the facility, carbon-free or low-carbon power must be considered. Options for low-carbon, continuous thermal and electrical energy were considered. The best-performing option from those considered was identified to be an electrically-heated molten salt energy storage system, powered by an on-site photovoltaic field. During molten salt thermal discharge, steam is produced from heat exchange with the molten salt and used to generate power in a steam turbine as well as steam for regenerating the DAC carbon trees. The thermal and electrical supply and analysis is presented in the context of low-carbon power for carbon removal. Modelling and economics of transportation and geologic storage of the CO2 is considered and presented for each location. The results of the feasibility study are incorporated into the presented techno-economic and life-cycle assessments. This work is intended to provide an understanding of the performance, cost, and impact of capturing CO2 at the commercial scale and the impact of climate and regional siting on the considered passive DAC system.

42 ENGINEERING↗

Evaluation of a high-resolution regional climate simulation for surface and hub-height wind climatology over North America

Assessing the availability of key wind resources requires augmenting observations to support the implementation of wind energy infrastructure. However, observations are limited, necessitating the development of high-resolution, long-term gridded datasets. This study presents a robust, dynamically downscaled climatological dataset, offering 20 years of hourly wind data at a 4 km spatial resolution across North America, and evaluates its performance against observations, including meteorological towers and automated surface-observing system (ASOS) stations, as well as coarse-resolution reanalysis data (the European Centre for Medium-Range Weather Forecasts (ECMWF) reanalysis version 5 (ERA5)). Results demonstrate that the downscaled high-resolution wind data outperform ERA5 in regions of complex terrain and coastal areas, with improved overlap coefficients for wind data distributions and reduced root mean square errors (RMSEs) for hub-height and near-surface diurnal wind patterns. The downscaled simulation also captures the synoptic drivers of seasonal wind direction patterns reasonably well, indicated by high wind rose similarity indices. This study also provides an analysis of interannual variability, utilizing the dataset's full 20-year period, and model uncertainty, generated by varying model initial conditions and physics parameterizations across 1-year ensemble members, which are key considerations for wind resource assessment in wind farm development.

17 WIND ENERGY↗

Unsteady aerodynamics of large-scale floating offshore wind turbines in surge motion

Unsteady aerodynamic loads significantly influence the design and wake flow field of floating offshore wind turbines, especially due to wave- or vibration-induced tower top motions triggering various unsteady phenomena. Recent studies show that increasing turbine sizes amplify unsteady aerodynamic effects, as their impact typically grows with rotor diameter. This work combines recent findings from experiments and simulations on model-scale FOWT aerodynamics with new numerical analyses of large-scale rotors, providing a comprehensive understanding of unsteady phenomena occurrence and impact. Numerical analyses of the IEA 15-MW and 22-MW rotors undergoing surge motions characterise the combined influence of motion-induced unsteady phenomena on rotor thrust. Results indicate that unsteady effects can reduce thrust force variations by up to 40% at realistic surge periods. These findings contrast with prior model-scale rotor investigations, attributed to the specialised design of the model rotors. Comparisons between numerical methods - the dynamic blade element momentum method in OpenFAST and free vortex wake modules in panMARE and OpenFAST - reveal persistent differences in thrust predictions under both idealised and realistic conditions. This highlights that classical blade element momentum approaches require enhancement to accurately capture unsteady loads on large-scale floating offshore wind turbines at low wind speeds.

16 TIDAL AND WAVE POWER↗

Retrofitting Holcim Ste. Genevieve Cement Plant with CO2 Capture Plant Using Air Liquide Cryocap™ FG Technology

The global cement manufacturing industry is a major contributor to carbon dioxide emissions. The International Energy Agency's "Net Zero Emissions by 2050 Scenario" identifies CCS as a major strategy for meeting that goal. This project is among the first attempts to transfer capture technology developed at coal-fired power plants to the cement industry. The main objective of the project is to execute and complete a front-end engineering and design (FEED) studies for commercial-scale, carbon capture projects that separates 95% of the total CO2 emissions at the Holcim (US) Ste. Genevieve cement manufacturing facility using Air Liquide’s Pressure Swing Adsorption system (PSA) assisted Cryocap™ technology. The Holcim Ste. Genevieve cement plant in Missouri, US, boasts one of the largest single cement production lines in the world, with a capacity of approximately 12,000 t/day. The plant currently uses traditional fuels, namely coal and petcoke. The captured CO2 will be pipeline and geological storage grade. The industrial host site emits approximately 3.0 million tonne CO2/yr. Air Liquide’s Cryocap™ technology has been developed over the last 18+ years for CO2 capture applications. It has been shown to be applicable to a variety of industrial applications (e.g., steel, cement, SMR, Fluidized Catalytic Crackers (FCCs)). Cryocap™ FG consists of a Pressure Swing Adsorption (PSA) unit coupled with a Cryogenic System. The PSA pre-concentrates the CO2 from the flue gas, while the cryogenic unit enables the CO2 purity to be increased to the desired level. The project team is led by the Prairie Research Institute at the University of Illinois at Urbana-Champaign. The tasks include: complete FEED study for retrofitting the industrial facility with a carbon capture system to support developing a detailed cost estimate; business case analysis outlining the anticipated revenue and credits if projects was built and operated; technoeconomic analysis (TEA) outlining how capture system achieves DOE capture goals; and life cycle (LCA) analysis demonstrating zero net carbon emissions. The FEED study was successfully completed. This includes completing the process basis of design; preliminary engineering; outside battery limits (OSBL) detailed engineering including a Zero Liquid Discharge (ZLD) wastewater treatment system; inside battery limits (ISBL) detailed engineering [1]. An overall project capital cost estimate within a -20%/+30% accuracy was developed. The major contributors to the Total Plant Cost (TPC), by system, are the costs associated with the Outside Battery Limit (OSBL) section of the plant which includes a new river water intake structure and a Zero Liquid Discharge (ZLD) system. By cost category, the major contributors to the TPC are equipment and subcontractor costs, followed closely by engineering, construction management, home office and contractor fees. The TEA has been created to reflect the findings of the project. It analyzes the economic performance of the Cryocap™ technology by reviewing the estimated capital costs, operating cost, and revenue. The Cost of Capture (COC) associated with the Cryocap™ technology for 95% CO2 capture, when considering NETL 2018 economic assumptions (42/58 debt/equity ratio, 5.15% interest on debt and 1.42% return on equity in real dollars) and 2022 economic assumptions (42/58 debt/equity ratio, 8.82% interest on debt and 4.90% return on equity in real dollars) was found to be much lower than that for the DOE-NETL’s base-line cases. The highest contributors to the COC are annualized capital expenditures (CAPEX) and electricity consumption which can be offset by using lower cost renewable sources. The LCA was conducted using OpenLCA which is an open-source software that is recommended by NETL. The database utilized for this study was a modified version of TRACI 2.1 (developed by the US. Environmental Protection Agency’s National Risk Management Research Laboratory and modified by NETL). The Cryocap™ FG technology does not consume fuels in significant quantities and does not utilize specialized chemical solvents subject to decomposition, such as those utilized in amine-based carbon capture systems. The Cryocap™ FG technology mainly utilizes electricity as its energy input; hence, its calculated emissions are mainly associated with the generation of electricity offsite and are dependent on the energy matrix of the grid at the time of project implementation. The water consumption impact of the Cryocap™ FG is mostly for makeup of the water lost by evaporation in the cooling tower; however, the carbon capture plant will be equipped with a ZLD system to avoid effluent streams and minimize water consumption. The successful construction and operation of this plant based on this study results will provide a means to demonstrate an economically attractive and transformational capture technology that can be used to retrofit existing plants and be deployed at new plants.