Temporal Structures in Positron Spectra and Charge-Sign Effects in Galactic Cosmic Rays

We present the precision measurements of 11 years of daily cosmic positron fluxes in the rigidity range from 1.00 to 41.9 GV based on 3.4 × 10 6 positrons collected with the Alpha Magnetic Spectrometer (AMS) aboard the International Space Station. The positron fluxes show distinctly different time variations from the electron fluxes at short and long timescales. A hysteresis between the electron fluxes and the positron fluxes is observed with a significance greater than 5⁢𝜎 at rigidities below 8.5 GV. On the contrary, the positron fluxes and the proton fluxes show similar time variation. Remarkably, we found that positron fluxes are modulated more than proton fluxes with a significance greater than 5⁢𝜎 for rigidities below 7 GV. These continuous daily positron fluxes, together with AMS daily electron, proton, and helium fluxes over an 11-year solar cycle, provide unique input to the understanding of both the charge-sign and mass dependencies of cosmic rays in the heliosphere.

astroparticles↗

Characterizing Dynamic Structure in Battery Electrodes by Time-Resolved Cryo-TEM

In recent years, cryogenic transmission electron microscopy (cryo-TEM) has enabled high-resolution characterization of sensitive battery materials by minimizing electron beam-induced artifacts and damage. Success of this technique relies on the preparation of thin, rapidly frozen samples, generally by disassembling batteries under inert atmosphere, transferring materials of interest to a TEM grid, and finally plunge freezing into a cryogen. In material degradation studies, this extensive time between electrochemical cycling and cryo-TEM characterization leaves room for structural relaxation, diffusion, and other dynamic processes that make it difficult to precisely correlate the imaged structure with the native structure that evolves during battery cycling or aging. Here, we present a method to integrate battery cycling with fast preparation of electrode samples for cryo-TEM. This enables higher fidelity between the structures characterized and the electrochemical state of interest, which we use to study deformation in silicon nanoparticle anodes for lithium-ion batteries.

CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS↗

Epitaxial Growth of 2D Core‐Crown SnS 2 /SnSe 2 Heterostructure Through Interfacial Modification with Polyvinylpyrrolidone

Abstract Developing generalized strategies for controlled synthesis of 2D heterostructures remains a significant challenge because the existing approaches often suffer from poor reproducibility and scalability. In this study, a solution synthesis approach for epitaxial core‐crown heterostructures with controlled band alignment, that overcomes these challenges is reported. Polyvinylpyrrolidone (PVP) is used as a structure‐directing agent to reduce lattice mismatch between SnS 2 and SnSe 2 (10‐10) surfaces and direct epitaxial growth of SnSe 2 crown on SnS 2 seed. Additionally, PVP adsorption to the basal plane prevents van der Waals stacking and stabilizes 2D heterostructures during synthesis. Driven by interfacial thermodynamics, the formation of the core‐crown heterostructure is highly reproducible and the size of the 2D heterostructure and relative areas of the core and the crown can be precisely controlled in a two‐step process by varying synthesis times for the seed and the crown. The identified growth pathway for 2D heterostructures can be generalized to other combinations of van der Waals materials to provide a platform for synthesizing micron‐size epitaxial heterostructures with a desired electronic structure for catalysis and microelectronics.

Liu, Lili [Physical and Computational Sciences Dir↗

First-principles simulation of light-ion microscopy of graphene

The extreme sensitivity of 2D materials to defects and nanostructure requires precise imaging techniques to verify presence of desirable and absence of undesirable features in the atomic geometry. Helium-ion beams have emerged as a promising materials imaging tool, achieving up to 20 times higher resolution and 10 times larger depth-of-field than conventional or environmental scanning electron microscopes. Here, we offer first-principles theoretical insights to advance ion-beam imaging of atomically thin materials by performing real-time time-dependent density functional theory simulations of single impacts of 10–200 keV light ions in free-standing graphene. Here we predict that detecting electrons emitted from the back of the material (the side from which the ion exits) would result in up to three times higher signal and up to five times higher contrast images, making 2D materials especially compelling targets for ion-beam microscopy. This predicted superiority of exit-side emission likely arises from anisotropic kinetic emission. The charge induced in the graphene equilibrates on a sub-fs time scale, leading to only slight disturbances in the carbon lattice that are unlikely to damage the atomic structure for any of the beam parameters investigated here.

36 MATERIALS SCIENCE↗

Development of a Platform at the Matter in Extreme Conditions End Station for Characterization of Matter Heated by Intense Laser-Accelerated Protons

High intensity short-pulse lasers have made possible the generation of energetic proton beams, unlocking numerous applications in high energy density science. One such application is uniform and isochoric heating of materials to the warm dense matter (WDM) state. We have developed a new experimental platform to simultaneously create and probe warm dense matter at the Matter in Extreme Conditions (MEC) end station at the Linac Coherent Light Source (LCLS). The short pulse optical laser (delivering up to 1 J in 45 fs) and the ultra-bright LCLS x-ray laser with tunable frequency respectively deliver high power required to heat materials to WDM and precision-timed high-resolution x-rays to probe them. The laser-accelerated proton beam driven from a flat 1.5 μm Cu foil was first measured then directed to a secondary sample of Al or polypropylene, typically 300-400 μm away. The time evolution of the sample electron temperature was measured using streaked optical pyrometry, where we observed a peak temperature of 0.9 0.15 eV on the rear surface of an Al sample heated by the proton beam. Here, the simulations using the hybrid-PIC code LSP and the rad-hydro code HELIOS show that a measured proton beam can heat Al to approximately 4 eV and polypropylene to 1 eV if instead focused by a hemispherical Cu target. Through additional LSP simulations, we anticipate creating hotter warm dense matter states (20 eV) by increasing the laser energy to 10 J and keeping the other laser parameters fixed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Speckle Interferometry at the Blanco and SOAR Telescopes in 2008 and 2009

The results of speckle interferometric measurements of binary and multiple stars conducted in 2008 and 2009 at the Blanco and Southern Astrophysical Research (SOAR) 4 m telescopes in Chile are presented. A tot al of 1898 measurements of 1189 resolved pairs or sub-systems and 394 observations of 285 un-resolved targets are listed. We resolved for the first time 48 new pairs, 21 of which are new sub-systems in close visual multiple stars. Typical internal measurement precision is 0.3 mas in both coordinates, typical companion detection capability is delta m approximately 4.2 at 0.15 degree separation. These data were obtained with a new electron-multiplication CCD camera; data processing is described in detail, including estimation of magnitude difference, observational errors, detection limits, and analysis of artifacts. We comment on some newly discovered pairs and objects of special interest.

TRIPLE STARS↗

Electron Backscatter Diffraction (EBSD) Analysis and U-Pb Geochronology of the Oldest Lunar Zircon: Constraining Early Lunar Differentiation and Dating Impact-Related Deformation

The evolution of the early moon was dominated by two processes (i) crystallization of the Lunar Magma Ocean (LMO) and differentiation of potassium-rare earth element-phosphorous-rich residual magma reservoir referred to as KREEP, and (ii) an intense meteorite bombardment referred to as lunar cataclysm . The exact timing of these processes is disputed, and resolution relies on collection and interpretation of precise age data. This study examines the microstructure and geochronology of zircon from lunar impact breccias collected during the Apollo 17 mission. A large zircon clast within lunar breccia 72215,195 shows sector zoning in optical microscopy, cathodoluminescence (CL) imaging and Raman mapping, and indicates that it was a relict fragment of a much larger magmatic grain. Sensitive high resolution ion microprobe (SHRIMP) U-Pb analysis of the zircon shows that U and Th concentration correlate with sector zoning, with darkest CL domains corresponding with high-U and Th (approx.150 and approx.100 ppm respectively), and the brightest-CL sectors containing approx.30-50 ppm U and approx.10-20 ppm Th. This indicates that variations in optical CL and Raman properties correspond to differential accumulation of alpha-radiation damage in each sector. Electron backscatter diffraction (EBSD) mapping shows that the quality of electron backscatter patterns (band contrast) varies with sector zoning, with the poorest quality patterns obtained from high-U and Th, dark-CL zones. EBSD mapping also reveals a deformation microstructure that is cryptic in optical, CL and Raman imaging. Two orthogonal sets of straight discrete and gradational low-angle boundaries accommodate approx.12 misorientation across the grain. The deformation bands are parallel to the crystallographic {a}-planes of the zircon, have misorientation axes parallel to the c-axis, and are geometrically consistent with formation by dislocation creep associated with <100>{010} slip. The deformation bands are unlike curved morphology of crystal-plastic microstructures in tectonically deformed terrestrial zircon, and geometrically similar to dislocation microstructures reported in experimentally shocked zircon. We interpret these crystal-plastic deformation microstructures to have resulted from a significant impact, either directly from impact shock, or during ductile flow directly following the impact. The deformation bands appear to continue undeflected through the non-indexed, radiation-damaged areas of the grain, which suggests that the orientation variation predates any significant mechanical weakening from radiation damage in the grain, and therefore occurred early in its history.

Timms, Nick↗

Absolute contrast estimation for soft X-ray photon fluctuation spectroscopy using a variational droplet model

Abstract X-ray photon fluctuation spectroscopy using a two-pulse mode at the Linac Coherent Light Source has great potential for the study of quantum fluctuations in materials as it allows for exploration of low-energy physics. However, the complexity of the data analysis and interpretation still prevent recovering real-time results during an experiment, and can even complicate post-analysis processes. This is particularly true for high-spatial resolution applications using CCDs with small pixels, which can decrease the photon mapping accuracy resulting from the large electron cloud generation at the detector. Droplet algorithms endeavor to restore accurate photon maps, but the results can be altered by their hyper-parameters. We present numerical modeling tools through extensive simulations that mimic previous x-ray photon fluctuation spectroscopy experiments. By modification of a fast droplet algorithm, our results demonstrate how to optimize the precise parameters that lift the intrinsic counting degeneracy impeding accuracy in extracting the speckle contrast. These results allow for an absolute determination of the summed contrast from multi-pulse x-ray speckle diffraction, the modus operandi by which the correlation time for spontaneous fluctuations can be measured.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Joint thrust and TMD resummation in electron-positron and electron-proton collisions

In this work, we present the framework for obtaining precise predictions for the transverse momentum of hadrons with respect to the thrust axis in e + e - collisions. This will enable a precise extraction of transverse momentum dependent (TMD) fragmentation functions from a recent measurement by the Belle Collaboration. Our analysis takes into account, for the first time, the nontrivial interplay between the hadron transverse momentum and the cut on the thrust event shape. To this end, we identify three different kinematic regions, derive the corresponding factorization theorems within Soft Collinear Effective Theory, and present all ingredients needed for the joint resummation of the transverse momentum and thrust spectrum at NNLL accuracy. One kinematic region can give rise to non-global logarithms (NGLs), and we describe how to include the leading NGLs. We also discuss alternative measurements in e + e - collisions that can be used to access the TMD fragmentation function. Finally, by using crossing symmetry, we obtain a new way to constrain TMD parton distributions, by measuring the displacement of the thrust axis in ep collisions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ultrafast X-ray scattering reveals vibrational coherence following Rydberg excitation

The coherence and dephasing of vibrational motions of molecules constitute an integral part of chemical dynamics, influence material properties, and underpin schemes to control chemical reactions. Significant progress has been made in understanding vibrational coherence through spectroscopic measurements, but the precise direct measurement of the structure of a vibrating excited-state polyatomic organic molecule has remained elusive. Here, we measure the time-evolving molecular structure of optically excited N-methyl morpholine through scattering with ultrashort X-ray pulses. The scattering signals are corrected for the different electron density in the excited electronic state of the molecule compared to the ground state. In conclusion, the experiment maps the evolution of the molecular geometry with femtosecond resolution, showing coherent motion that survives electronic relaxation and appears to persist for longer than previously seen using other methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of X-ray Wavefront Sensing Techniques for Adaptive Optics Control at the Advanced Photon Source

The planning and construction of new and upgraded high-brightness X-ray synchrotron and free electron laser sources, such as the Advanced Photon Source upgrade project (APS-U), are driving numerous opportunities to advance X-ray science and technologies. At the same time, an increasing number of highly diverse beamline experiments demand wavefront-preserving adaptive X-ray optics with both high precision and flexibility. At the APS, significant effort has been devoted to developing next-generation adaptive and corrective optics combined with state-of-the-art at-wavelength wavefront sensing techniques and an intelligent feedback control system for the automation and self-alignment of beamline optical systems. This article reviews recent achievements in these areas at the APS. Further, these include the development of in-situ wavefront sensing, the application in active feedback control of ultra-precision deformable mirrors, and the exploration of non-invasive wavefront sensing techniques for adaptive optics and beamline diagnostics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-time atmospheric absorption spectra for in-flight tuning of an airborne dial system

Real-time measurements of atmospheric absorption spectra are displayed and used to precisely calibrate and fix the frequency of an Alexandrite laser to specific oxygen absorption features for airborne Differential Absorption Lidar (DIAL) measurements of atmospheric pressure and temperature. The DIAL system used contains two narrowband tunable Alexandrite lasers: one is electronically scanned to tune to oxygen absorption features for on-line signals while the second is used to obtain off-line (nonabsorbed) atmospheric return signals. The lidar operator may select the number of shots to be averaged, the altitude, and altitude interval over which the signals are averaged using single key stroke commands. The operator also determines exactly which oxygen absorption lines are scanned by comparing the line spacings and relative strengths with known line parameters, thus calibrating the laser wavelength readout. The system was used successfully to measure the atmospheric pressure profile on the first flights of this lidar, November 20, and December 9, 1985, aboard the NASA Wallops Electra aircraft.

Dombrowski, M.↗

DC isolation and protection system and circuit

A precision analog electronic circuit that is capable of sending accurate signals to an external device that has hostile electric characteristics, including the presence of very large common mode voltages. The circuit is also capable of surviving applications of normal mode overvoltages of up to 120 VAC/VDC for unlimited periods of time without damage or degradation. First, the circuit isolates the DC signal output from the computer. Means are then provided for amplifying the isolated DC signal. Further means are provided for stabilizing and protecting the isolating and amplifying means, and the isolated and amplified DC signal which is output to the external device, against overvoltages and overcurrents.

Wagner, Charles A.↗

Using cyclotron radiation emission for ultra-high resolution x-ray spectroscopy

Abstract Cyclotron radiation emission spectroscopy (CRES) is an approach to measuring the energy of an electron trapped in an externally applied magnetic field. The bare electron can come from different interactions, including photoelectric absorption, Compton scatters, beta decay, and pair production. CRES relies on measuring the frequency of the electron’s cyclotron motion, and because the measurement times extend over 10 6 –10 7 cycles, the energy resolution is on the order of a single electronvolt. To date, CRES has only been performed on internal beta-emitting radioisotopes, but the technology can be applied to x-ray spectrometery through appropriate selection of a target gas and sufficient intensity of the distinct x-ray source. The applications of this technology range from high-precision measurements of atomic energy levels to calibrations of basic science experiments, to trace element identification. In this work we explore the use of CRES for x-ray spectroscopy within the rubric of measuring the energy levels of argon. Though the energy levels of argon are well established, we adopt this motivation as an example question around which a detector may be designed. The issues we explore include target material, density, electron trapping depth, noise levels, and overall efficiency. We also discuss spectral deconvolution and how the multiple peaks obtained from a single target/source pair can be used to enhance the robustness of the measurement.

07 ISOTOPE AND RADIATION SOURCES↗

Precision measurement of the electron energy-loss function in tritium and deuterium gas for the KATRIN experiment

Abstract The KATRIN experiment is designed for a direct and model-independent determination of the effective electron anti-neutrino mass via a high-precision measurement of the tritium $$\upbeta $$ β -decay endpoint region with a sensitivity on $$m_\nu $$ m ν of 0.2 $$\hbox {eV}/\hbox {c}^2$$ eV / c 2 (90% CL). For this purpose, the $$\upbeta $$ β -electrons from a high-luminosity windowless gaseous tritium source traversing an electrostatic retarding spectrometer are counted to obtain an integral spectrum around the endpoint energy of 18.6 keV. A dominant systematic effect of the response of the experimental setup is the energy loss of $$\upbeta $$ β -electrons from elastic and inelastic scattering off tritium molecules within the source. We determined the energy-loss function in-situ with a pulsed angular-selective and monoenergetic photoelectron source at various tritium-source densities. The data was recorded in integral and differential modes; the latter was achieved by using a novel time-of-flight technique. We developed a semi-empirical parametrization for the energy-loss function for the scattering of 18.6-keV electrons from hydrogen isotopologs. This model was fit to measurement data with a 95% $$\hbox {T}_2$$ T 2 gas mixture at 30 K, as used in the first KATRIN neutrino-mass analyses, as well as a $$\hbox {D}_2$$ D 2 gas mixture of 96% purity used in KATRIN commissioning runs. The achieved precision on the energy-loss function has abated the corresponding uncertainty of $$\sigma (m_\nu ^2)< {{10}^{-2}}{\hbox {eV}^{2}}$$ σ ( m ν 2 ) < 10 - 2 eV 2 [1] in the KATRIN neutrino-mass measurement to a subdominant level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combining Spatial and Temporal Resolution in Cryo-TEM of Device Materials: Preprint

Cryogenic transmission electron microscopy (cryo-TEM) has been instrumental to reducing the effects of electron-beam sample interactions and enabling higher spatial resolution studies of beam sensitive materials. However, the process of thinning and freezing samples for cryo-TEM characterization is often complex and frequently involves removing materials from their environment or stimuli of interest for extended times. This can allow for structural relaxation, diffusion, and other dynamic processes to occur prior to characterization; for energy materials like battery electrodes, this makes it difficult to precisely correlate the imaged structure with native structures that evolve in-situ during device processing, operation, or aging. Here, we present methods to prepare cryo-TEM samples from energy materials during these critical processes in the relevant device lifetimes. This offers insights into improving the temporal resolution of cryo-TEM, while still exploiting its ability to achieve high spatial resolutions in characterizing beam sensitive materials.

BASIC BIOLOGICAL SCIENCES,MATERIALS SCIENCE↗

The BigBite Calorimeter for the Super Bigbite Spectrometer Program at Jefferson Lab

Here, we report features of the design, construction, installation, and performance of the BigBite Calorimeter (BBCal), a lead-glass electromagnetic calorimeter constructed as part of the BigBite Spectrometer (BBS), which served as the electron arm for the Super Bigbite Spectrometer (SBS) program of high-precision neutron electromagnetic form factor measurements in Hall A at Jefferson Lab. As a total-absorption calorimeter, BBCal provided the primary electron trigger for BBS, detecting quasi-elastically scattered electrons in the 1–4 GeV energy range with an energy resolution of approximately 6.2%, position resolution of 1.2 cm, and timing resolution of 0.5 ns.

BBCal↗