Search NASA⌕ Search

SEARCH · Search NASA

Results for “Precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

A multimodal and integrated approach to interrogate human kidney biopsies with rigor and reproducibility: guidelines from the Kidney Precision Medicine Project

Comprehensive and spatially mapped molecular atlases of organs at a cellular level are a critical resource to gain insights into pathogenic mechanisms and personalized therapies for diseases. The Kidney Precision Medicine Project (KPMP) is an endeavor to generate three-dimensional (3-D) molecular atlases of healthy and diseased kidney biopsies by using multiple state-of-the-art omics and imaging technologies across several institutions. Obtaining rigorous and reproducible results from disparate methods and at different sites to interrogate biomolecules at a single-cell level or in 3-D space is a significant challenge that can be a futile exercise if not well controlled. Here we describe a “follow the tissue” pipeline for generating a reliable and authentic single-cell/region 3-D molecular atlas of human adult kidney. Our approach emphasizes quality assurance, quality control, validation, and harmonization across different omics and imaging technologies from sample procurement, processing, storage, shipping to data generation, analysis, and sharing. We established benchmarks for quality control, rigor, reproducibility, and feasibility across multiple technologies through a pilot experiment using common source tissue that was processed and analyzed at different institutions and different technologies. A peer review system was established to critically review quality control measures and the reproducibility of data generated by each technology before their being approved to interrogate clinical biopsy specimens. The process established economizes the use of valuable biopsy tissue for multiomics and imaging analysis with stringent quality control to ensure rigor and reproducibility of results and serves as a model for precision medicine projects across laboratories, institutions and consortia.

59 BASIC BIOLOGICAL SCIENCES↗

OpenMxP-Opensource Mixed Precision Computing

This is an opensource library for benchmarking the system's GPU mixed precision capabilities. The software calculates solution of the system of linear equation in 64bit accuracy using mixed precision techniques and iterative refinement. Original benchmark designed is done by ICL, and it is name HPL-MxP (HPL-AI)

Lu, Hao↗

Hybrid method for monitoring large Fabry-Pérot cavity displacements with nanometer precision

The change in length of an optical fiber-based Fabry-Pérot cavity (FPC) can be precisely measured using phase tracking, but the displacement range is limited by phase ambiguity. Period tracking techniques determine the absolute FPC length, but with larger uncertainties from tracking the spacing between multiple peaks. A hybrid method is demonstrated that identifies appropriate peaks for phase tracking using a coarse estimate obtained from the free spectral range to effectively maintain the high precision (∼1 nm) of phase tracking techniques to measure ∼24 µ m displacements, well beyond the range limitations (typically <1 µ m) of phase tracking methods.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Directed self-assembly of block copolymers for high-precision patterning in the era of extreme ultraviolet lithography

Extreme ultraviolet (EUV) lithography enables unprecedented resolution in semiconductor patterning but faces critical challenges in developing resist materials that achieve high-precision at economically viable throughput. Directed self-assembly (DSA) of block copolymers (BCPs) offers a promising solution for pattern rectification by leveraging thermodynamically determined domain structures to decouple BCP pattern quality from the imperfect original lithographic pattern. This prospective presents an overview of recent progress on the EUV + DSA strategy, covering advances in BCP material design, processing, metrology, and pattern transfer. We highlight recent advances in high-χ BCPs with perpendicular orientation and domain spacings compatible with EUV dimensions, leveraging A-b-(B-r-C) architectures. We also discuss progress in chemical pre-pattern fabrication using both positive- and negative tone resists, along with processing strategies to minimize defects and roughness based on BCP thermodynamics and assembly kinetics. We further examine metrology platforms for characterizing the thermodynamics of BCP materials and quantifying the size and shape of BCP domains. Lastly, we review pattern transfer strategies for generating functional inorganic masks suitable for semiconductor manufacturing. Together, these advances highlight the potential of DSA to complement EUV lithography, offering a pathway to address critical challenges in achieving high-precision patterning for the semiconductor industry.

Lee, Kyunghyeon [Univ. of Chicago, IL (United Stat↗

High-Precision Characterization of Seismicity from the 2022 Hunga Tonga-Hunga Ha'apai Volcanic Eruption

The earthquake swarm accompanying the January 2022 Hunga Tonga-Hunga Ha'apai (HTHH) volcanic eruption includes a large number of posteruptive moderate-magnitude seismic events and presents a unique opportunity to use remote monitoring methods to characterize and compare seismic activity with other historical caldera-forming eruptions. We compute improved epicentroid locations, magnitudes, and regional moment tensors of seismic events from this earthquake swarm using regional to teleseismic surface-wave cross correlation and waveform modeling. Precise relative locations of 91 seismic events derived from 59,047 intermediate-period Rayleigh- and Love-wave cross-correlation measurements collapse into a small area surrounding the volcano and exhibit a southeastern time-dependent migration. Regional moment tensors and observed waveforms indicate that these events have a similar mechanism and exhibit a strong positive compensated linear vector dipole component. Precise relative magnitudes agree with regional moment tensor moment magnitude ($M_w$) estimates while also showing that event sizes and frequency increase during the days after the eruption followed by a period of several weeks of less frequent seismicity of a similar size. The combined information from visual observation and early geologic models indicate that the observed seismicity may be the result of a complex series of events that occurred after the explosive eruption on 15 January, possibly involving rapid resupply of the magma chamber shortly after the eruption and additional faulting and instability in the following weeks. In addition, we identify and characterize an $M_w$ 4.5 event five days before the paroxysmal explosion on 15 January, indicating that additional seismic events preceding the main eruption could have been identified with improved local monitoring. As a result, our analysis of the HTHH eruption sequence demonstrates the value of potentially utilizing teleseismic surface-wave cross correlation and waveform modeling methods to assist in the detailed analysis of remote volcanic eruption sequences.

58 GEOSCIENCES↗

Precision Gas System (PGS) Instrument Handbook

This precision gas system (PGS) makes high-accuracy, high-precision measurements of CO2 mixing ratio (ppmv dry air) in air sampled at 2, 4, 25, and 60 m above the ground.

54 ENVIRONMENTAL SCIENCES↗

The Precision of Product Consistency Tests with Environmental Assessment Glass

Several series of triplicate tests conducting following the ASTM C1285 product consistency test method have been performed using samples of Environmental Assessment glass in Teflon™ and steel test vessels. The results of tests with test parameters within the ranges specified in the PCT method A procedure were used to calculate repeatability and reproducibility precision statistics for tests in each type of vessel. These show the test response and test precision attained in tests conducted in Teflon™ and stainless steel test vessels are statistically indistinguishable.

36 MATERIALS SCIENCE↗

High-Performance/-Precision/-Z(HPPZ) Scintillator Grids via Advanced Electrochemistry. Phase I – Project # 20210572MFR- Mid year review [Slides]

Scintillation grids with improved imaging resolution in time and space, are required for future mission needs at various facilities (pRad user station, LANSCE, DARHT, Scorpius etc). Current technologies use inorganic crystal scintillators, which are positioned within a high-Z scintillator septa. Dense and high-Z materials are optimal for gamma-ray detection making them promising candidates for development of high -performance/-precision/-Z (HPPZ) scintillator grids. The current resolution of standard chemical etching and fabrication processes of high-Z materials is very low, leading to undesired undercutting and ultimately reducing crystal performance efficiency. Goals are to: Perform initial feasibility studies with the aim of producing complex parts for applications with difficult-to-process high-Z material; Use of pulse and pulse-reverse electrochemical methods on additive approaches to produce high-precision Au and Re scintillator grids at a small scale; and, Follow up in Phase II with the delivery of a large-scale scintillator grid of the best material candidate with unprecedented properties for LANL needs determined in Phase I.

36 MATERIALS SCIENCE↗

Mixed Precision xsdk Project. Final Report

Two main tasks have been performed in the past year as part of the Mixed Precision xsdk Project: analysis and development of mixed precision algorithms, and community engagement. Each is briefly discussed and work summarized.

97 MATHEMATICS AND COMPUTING↗

Precision of Property Measurements with Reference Molten Salts

Thermochemical and thermophysical properties of reference molten salt systems are being measured to establish the precisions achievable with current state-of-the-art methods including repeatability within a laboratory and reproducibility between laboratories using the same and different methods. Several laboratories across the United States are analyzing salt samples from single source batches of two salts to provide independent measurements of property values and the precisions of different measurement techniques in an interlaboratory study referred to as the Interlaboratory Salt Study (ISS). The compositions of the two salts produced for the study were reported to be eutectic LiF-NaF-KF (46.5-11.5-42 mol %) and NaCl-KCl (50-50 mol %). These salts are referred to herein as ISS FLiNaK and ISS NaCl-KCl. Thermochemical properties being measured at Argonne include thermal transitions and heat capacity by differential scanning calorimetry. Thermophysical properties being measured at Argonne include liquid density and surface tension by using a buoyancy densitometer and thermal diffusivity by using a laser flash analyzer. Thermal conductivity is calculated from measured thermal diffusivity, density and heat capacity values. The results of property measurements made at Argonne using these inter-laboratory salt study salts are presented here.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Requirements Documents for the Large Mechanical Parts Precision Cleaner (LMPPC) in the Optics Assembly Building (OAB)

The National Ignition Facility (NIF) is the world's largest energetic laser whose missions include sresearch in inertial confinement fusion, experiments for the Stockpile Stewardship, and other high fluence laser research. Due to the high fluence of lasers, extreme environmental conditions, and radiation presence, all mechanical parts (metal, plastic, etc.) installed on NIF must be precision cleaned. Precision cleaned parts are also required in supporting facilities like the Optics Processing Facility (OPF). Small debris inside the laser beams or on optics can cause optic damage, interfere with diagnostics, and interfere with experiments.

42 ENGINEERING↗

Atomically Precise Manufacturing for 2D-Designed Materials

The primary purpose of this program was to develop atomically precise fabrication techniques for semiconductor systems that places dopant atoms in a single buried (100) atomic plane in silicon with near atomic precision to create unprecedented structures that can be used for a wide variety of quantum experiments, devices, and potentially designer quantum materials. The potential impacts on reducing industrial energy use are many: 1) optimized and more energy efficient industrial processes via more efficient computational approaches, 2) dramatically improved materials for industrial use including higher critical-temperature superconductors eliminating losses in electrical transmission, 3) the better understanding of quantum chemistry via Analog Quantum Simulation(AQS) in the near term and universal quantum computing in the longer term that will lead to new industrial processes with smaller or zero production of greenhouse gases.

36 MATERIALS SCIENCE↗

Mixed Precision xsdk Project: Final Report for Year Ended March 31, 2022

In the past year, as part of the Mixed Precision xsdk Project we have worked an the development and analysis of algorithms for mixed precision hardware. In the following we briefly discuss and summarize our contributions. The postdoctoral researchers were Srikara Pranesh (to September 30, 2021) and Mantas Mikaitis (from October 1, 2021).

97 MATHEMATICS AND COMPUTING↗

Approach to Precision and Bias Analysis of Interlaboratory Salt Study Results

An interlaboratory study of salt properties measurements was initiated in 2020 by Raluca Scarlatt of UC Berkley and Jake McMurray of Oak Ridge National Laboratory as a DOE-funded NEUP project. The objective of what is referred to as the interlaboratory salt study (ISS) was to assess the quality of molten salt property data and develop consensus standard methods for measuring key property values. Unlike many interlaboratory studies in which the precision of applying a well-defined and well-constrained method is measured, the methods used to measure property values were not specified nor were the measurement conditions controlled. Instead, the approach was to engage participants in measuring the property values of two commonly-used salt mixtures by using any desired measurement techniques. By including measurements made using the same and different methods across institutions, the precisions achieved using specific techniques can be assessed as well as the confidence in the values measured using different techniques. Details of the calibrations and uncertainty provided by the participants will be useful in establishing a best practice for the application of each technique to molten salts.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

PROSPECT: A Precision Reactor Oscillation and Spectrum Experiment

Nuclear reactors are a source of copious amounts of electron antineutrinos. They are emitted in the beta decays of the fission products and their energies depend on the isotopic composition of the reactor. In recent years a number of reactor antineutrino experiments including Daya Bay, Double Chooz, and RENO reported a deficit in the measured flux of antineutrinos from reactors compared to expectation and a spectral deviation in the measured energy spectra compared to model predictions. These observations led to the hypothesis of sterile neutrino oscillation as an explanation of the flux deficit. New physics or incomplete nuclear models may explain the origin of the spectral deviation. PROSPECT, the Precision Reactor Oscillation and Spectrum Experiment, is a novel neutrino experiment at the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL) designed to address two major scientific objectives: 1. Perform a search for eV-scale sterile neutrinos independent of reactor neutrino models by searching for the oscillation signature of massive, sterile neutrino states beyond the 3 known active neutrino species. The discovery of sterile neutrinos would indicate a new form of matter and require physics beyond the Standard Model. 2. Perform the first modern precision measurement of the antineutrino spectrum from a Highly Enriched Uranium (HEU) 235 U reactor to benchmark our understanding of the neutrino emission from nuclear reactors and to understand the isotopic origin of spectral deviations observed in previous reactor neutrino experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Powered by PRECISE [Slides]

This presentation is part of the National Renewable Energy Laboratory's (NREL's) Powered By webinar series, hosted by the Grid Planning and Analysis Center. The series highlights NREL's impressive suite of grid planning and analysis tools to help attendees better understand their capabilities and applications. In this presentation, NREL power grid researchers, Killian McKenna and Darice Guittet, and the principal electrical distribution engineer at Sacramento Municipal Utility District, Sheikh Hassan, discuss NREL's PRECISE interconnection tool. PRECISE automates holistic distributed energy resource interconnection studies for distribution utilities by leveraging diverse utility datasets.

14 SOLAR ENERGY↗

Precise Compositional Characterization of Plutonium Alloys by Electron Probe Microanalysis

Key Takeaway Points: • Unlike most other materials, the precise compositional analysis of plutonium, including compounds and alloys, is riddled by numerous difficulties that are unique to the element, including the high atomic number and radioactive nature. There’s work to be done! • Radioactive materials require special handling to ensure precise compositions can be measured by EPMA. • Mean Atomic Number background corrections are limited due to high average atomic number. • Mass Absorption Coefficients are unknown for most light elements. Quantification relies upon calibration curves. • Principal Component Analysis could be a useful tool to improve interpretation of complicated, multiple element X-ray maps.

Maner, IV, James L.↗

Integrated Spatial, Spectral, & Temporal Optical Reflectance System for Precision Occupancy & Location Sensing to Improve Building Energy Efficiency

Buildings consume approximately 35% of the electricity used in the U.S. and building owners can significantly reduce this energy use by providing services like heating, electrical power and lighting only when people are present. The ARPAe funded program titled “INTEGRATED SPATIAL, SPECTRAL, & TEMPORAL OPTICAL REFLECTANCE SYSTEM FOR PRECISION OCCUPANCY & LOCATION SENSING TO IMPROVE BUILDING ENERGY EFFICIENCY” demonstrates how a low cost sensor technology developed for measuring distances can be used to count and locate occupants with a high degree of precision with a very low error rates. This platform tells a building control system where occupants are located (but not who they are) so that energy consuming services can be provided only when the services are needed by building occupants. The original proof of concept involved using low cost, commercially available time-of-flight (TOF) sensors that measure distance, but the performance of these existing sensors was lacking, as they could not operate properly in the presence of sunlight, which blinded the simple TOF sensors and limited their utility in buildings. This project proposed a powerful new class of TOF sensors that used state-of-the-art integrated circuit (IC) fabrication processes that combined advanced photonics with conventional silicon chip circuitry for improved sensor performance. An equally important part of this project was to find ways to maximize occupant count and location accuracy while using the fewest number of sensors possible, in order to keep costs low. By using building blueprints to create digital twins of commercial building spaces, the team developed new algorithms to maximize occupant count and tracking accuracy by properly locating the minimum number of sensors at just the right spots in the building. This capability not only minimizes system costs but also simplified sensor installation and system commissioning. Our simulations of our sensor networks for a range of commercial floorplan designs demonstrated that our installed cost target of $0.08/sqft was attainable, though not fully demonstrated during the project. Finally, we noted that the TOF sensor concept could provide a valuable role in health and eldercare by tracking patients without the need for worn sensors and would be useful for fall detection and other patient safety metrics, including tracking healthcare/patient interactions. We feel that, when fully developed, this new class of sophisticated TOF sensors and support software will be a powerful new approach to improving building energy efficiency based on occupant centric control platforms and will also open new levels of patient safety in healthcare operations. To realize this potential, the team formed the Troy Sensor Company LLC to oversee licensing of the programs patents and continue to seek commercialization of this program’s activity sensing technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗