SEARCH · Search NASA
Results for “Quality Control”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
pmartR : Quality Control and Statistics for Mass Spectrometry-Based Biological Data
Not Available
Surface photovoltage method for the quality control of silicon epitaxial layers on sapphire
The surface photovoltage method is used to study “silicon-on-sapphire” epitaxial layers with a thickness of 0.3–0.6 μm, which are used to fabricate p-channel MOS (metal—oxide-semiconductor) transistors with improved radiation hardness. It is shown that the manner in which the photoconductivity of the epitaxial layer decays after the end of a light pulse generated by a light-emitting diode (wavelength ∼400 nm) strongly depends on the density of structural defects in the bulk of the structure. This enables control over how a “silicon-on-sapphire” structure is formed to provide the manufacturing of MOS structures with optimal operating characteristics.
Energy Auditor and Quality Control Inspector Certification Updates
This presentation discusses recent and future Home Energy Professional credential and resource updates at the National Renewable Energy Laboratory in support to the U.S Department of Energy's Weatherization Assistance Program (WAP). It will provide an in-depth overview of planned improvements to the EA and QCI certification schemes.
Quality Control in Fast Pyrolysis Bio-Oil Production and Use
This paper will focus on norms and standards for fast pyrolysis bio-oils. It will include the present status and address what still has to be done on bio-oil specifications and relevant test methods. The paper will address industrial needs in commercialization of the fuel oil use of bio-oil, including the registration application to the REACH program and its consequences within the European Union, as well as development of a standard within ASTM. The paper will discuss the most important properties of bio-oil and the variation in these properties among various bio-oils. It will address the issue of quality follow-up in bio-oil production, including the properties to be followed and the laboratory and on-line monitoring methods. The paper will provide a state of the art of fuel oil specifications, test methods, and testing procedures as they are applied to bio-oil. It will review the effort in support of the implementation of an ASTM standard including the methods validation work.
Integrated System of Thermal/Dimensional Analysis for Quality Control of Metallic Melt and Ductile Iron Casting Solidification
The main objective of the present work is to introduce a specific experimental instrument and technique for simultaneously evaluating cooling curves and expansion or contraction of cast metals during solidification. Contraction/expansion analysis illustrates the solidification parameters progression, according to the molten cast iron characteristics, which are dependent on the melting procedure and applied metallurgical treatments, mold media rigidity and thermal behavior [heat transfer parameters]. The first part of the paper summarizes the performance of this two-mold device. Its function is illustrated by representative shrinkage tendency results in ductile cast iron as affected by mold rigidity (green sand and furan resin sand molds) and inoculant type (FeSi-based alloys), published in part previously. The second part of the paper illustrates an application of this equipment adapted for commercial foundry use. It conducts thermal analysis and volume change measurements in a single ceramic cup so that mold media as well as solidification conditions are constants, with cast iron quality as the variable. Experiments compared gray and ductile cast iron solidification patterns. Gray iron castings are characterized by higher undercooling at the beginning and at the end of solidification and lower graphitic expansion. Typically, ductile cast iron exhibits higher graphitic, initial expansion, conducive for shrinkage formation in soft molds.
Results of The Excreta Bioassay Quality Control Program For April 1, 2010 Through March 31, 2011
A total of 76 urine samples and 10 spiked fecal samples were submitted during the report period (April 1, 2010 through March 31, 2011) to GEL Laboratories, LLC in South Carolina by the Hanford Internal Dosimetry Program (IDP) to check the accuracy, precision, and detection levels of their analyses. Urine analyses for 14C, Sr, for 238 Pu, 239 Pu, 241 Am, 243 Am, 235U, 238U, 238U-mass and fecal analyses for 241Am, 238 Pu and 239 Pu were tested this year. The number of QC urine samples submitted during the report period represented 1.1% of the total samples submitted.
Loss of protein synthesis quality control in host-restricted organisms
Significance This case study reveals that parasitic and symbiotic lifestyles affect the structure of essential molecular machineries of a living cell. We provide evidence that intracellular parasitism and endosymbiosis cause degeneration of the editing domains in aminoacyl-tRNA synthetases, a defect that is known to cause inaccurate translation of the genetic code. This finding suggests that most intracellular pathogens, including causative agents of human disease, have an unanticipated proteome diversity caused by inaccurate translation of the genetic code. Our finding may change current approaches to the study of proteomes of intracellular parasites, parasite–host interactions, and parasites’ sensitivity to drugs, which cause errors in transcription, translation, and protein folding.
Clinical Ion Beam Applications: Basic Properties, Application, Quality Control, Planning
Heavy-ion therapy using beam scanning and biological dose optimization is a novel technique of high-precision external radiotherapy. It yields a better perspective for tumor cure of radio-resistant tumors. However, heavy-ion therapy is not a general solution for all types of tumors. As compared to conventional radiotherapy, heavy-ion radiotherapy has the advantages of higher tumor dose, improved sparing of normal tissue in the entrance channel, a more precise concentration of the dose in the target volume with steeper gradients to the normal tissue, and a higher radiobiological effectiveness for tumors which are radio-resistant in conventional therapy. These properties make it possible to treat radio-resistant tumors with great success, including those in close vicinity to critical organs.
Quality control of concrete at the stage of designing its composition and technology
The results of tests on samples of foam concrete with a hardening accelerator are presented. As the setting and hardening accelerators the following chemical additives were used: Universal-P-2 and Asilin 12. All additives were added into the insulating foam concrete mix of brand D 400 in the amount of 0.5% to 1% of cement weight. By using of additives in foam concrete technology – hardening accelerators Asilin 12 and Universal P2 in the amount of 0.5 % - and 1.0% by weight of cement foam concrete structure formation is accelerated and increases strength by 60%. For the industrial preparation of foam concrete mix technological regulations are worked out, in which it is recommended to use additives – hardening accelerators Asilin 12 in the amount of 0.5% and Universal P2 - 1% of cement weight.
SU-E-T-153: Establish a Comprehensive Patient-Specific Plan QA Database for Instituitional Quality Control Program
Purpose: Since the publication of TG-119, several new treatment techniques requiring new QA devices have been implemented in the clinic. To monitor and analyze our institutional QA performance, we have created a comprehensive QA database using Research Electronic Data Capture (REDCap). The database will also assist us in creating IMRT QA Analysis practice guidelines. Methods: Since Oct. 2013, 336 patient plan QA results were entered into the database. Plan parameters such as plan ID, treatment site, technique, energy, optimization constraints, modulation factor, leaf speed, leaf opening.etc were automatically extracted from the Varian Eclipse database to allow us to refine our evaluation and analysis method. Specific QA device, LINAC-related information, and measurement and analysis results were manually entered by the QA team. IMRT plans were measured using MapCHECK2 while RapidArc plans were measured using ArcCHECK. Distance-To-Agreement 3%/3mm without global maximum normalization was used. Results: The data indicates that different treatment techniques might benefit from a different site-specific action level(AL) depending on the complexity of the plan and optimization parameter used (e.g., breast IMRT QA= 97.8% and pelvis IMRT QA=93.1%). Different QA devices may also benefit from a different AL (MapCHECK2 = 94.1% while ArcCHECK = 83.0%). The relationship between the parameters and passing rate suggests that the complexity of each plan, characterized by leaf travel, leaf opening and modulation factor, affect the passing rate significantly. The database is reviewed regularly, and any abnormal point of the QA result or a trend of lower QA passing rate on a specific LINAC is further investigated. Conclusion: Establishing a comprehensive QA database provides an overview of the quality assurance program. It not only helps in answering the question “what is a reasonable and achievable standard for each institution”, but also saves time in monitoring and investigating the daily machine and QA performance.
Experience with the Quality Control of Radioactive Waste Packages for the German Repository Konrad - 16493
The German repository Konrad for radioactive waste with negligible heat generation is designed to accept 303,000 m{sup 3} of waste packages in total. Based on the Konrad licensing conditions, any treatment and conditioning of radioactive waste should be planned and carried out in accordance with the waste acceptance requirements of the repository Konrad in order to produce waste packages suitable for disposal. The qualification of the waste treatment processes and the resulting products are achieved by interaction of different parties involved. On behalf of the Federal Office for Radiation Protection - the competent German authority for disposal of radioactive waste - TUV NORD EnSys Hannover GmbH and Co. KG acts as one of the independent expert organizations for more than twenty years in the field of qualification of waste treatment campaigns and review of waste packages documentations. The permitted amount of nuclide activity in the radioactive waste packages depends on the characteristics of the radioactive waste products. Projecting a suitable strategy for loading the waste containers contributes to determine in advance, what requirements the radioactive waste products have to fulfill as well as what properties of the waste products need to be verified and documented during conditioning or treatment process. On the basis of various examples, it is being demonstrated how appropriate advance process planning can ensure that radioactive waste packages are generated to comply with the waste acceptance requirements. In consequence, technical measures due to requalification can be avoided even in case of unpredictable difficulties. (authors)
Snowex 2017 Community Snow Depth Measurements: A Quality-Controlled, Georeferenced Product
Snow depth was one of the core ground measurements required to validate remotely-sensed data collected during SnowEx Year 1, which occurred in Colorado. The use of a single, common protocol was fundamental to produce a community reference dataset of high quality. Most of the nearly 100 Grand Mesa and Senator Beck Basin SnowEx ground crew participants contributed to this crucial dataset during 6-25 February 2017. Snow depths were measured along ~300 m transects, whose locations were determined according to a random-stratified approach using snowfall and tree-density gradients. Two-person teams used snowmobiles, skis, or snowshoes to travel to staked transect locations and to conduct measurements. Depths were measured with a 1-cm incremented probe every 3 meters along transects. In shallow areas of Grand Mesa, depth measurements were also collected with GPS snow-depth probes (a.k.a. MagnaProbes) at ~1-m intervals. During summer 2017, all reference stake positions were surveyed with <10 cm accuracy to improve overall snow depth location accuracy. During the campaign, 193 transects were measured over three weeks at Grand Mesa and 40 were collected over two weeks in Senator Beck Basin, representing more than 27,000 depth values. Each day of the campaign depth measurements were written in waterproof field books and photographed by National Snow and Ice Data Center (NSIDC) participants. The data were later transcribed and prepared for extensive quality assessment and control. Common issues such as protocol errors (e.g., survey in reverse direction), notebook image issues (e.g., halo in the center of digitized picture), and data-entry errors (sloppy writing and transcription errors) were identified and fixed on a point-by-point basis. In addition, we strove to produce a georeferenced product of fine quality, so we calculated and interpolated coordinates for every depth measurement based on surveyed stakes and the number of measurements made per transect. The product has been submitted to NSIDC in csv format. To educate data users, we present the study design and processing steps that have improved the quality and usability of this product. Also, we will address measurement and design uncertainties, which are different in open vs. forest areas.
Data Quality Control for Vessel Mounted Acoustic Doppler Current Profiler. Application for the Western Mediterranean Sea
A systematic Data Quality Checking Protocol for vessel Mounted Acoustic Doppler Current Profiler observations is proposed. Previous-to-acquisition conditions are considered along with simultaneous ones.
Dosimetric characteristics and quality control tests for the collimator sectors of the Leksell Gamma Knife Perfexion{sup TM}
Purpose: The purpose of this study was to evaluate the dosimetric characteristics of each sector of the Leksell Gamma Knife Perfexion (LGK PFX) and to develop tests that can be done for the routine quality assurance checks of the sectors of the LGK PFX. Methods: The following tests were performed to evaluate the dosimetric characteristics of the sectors: (1) Flash-radiation dose for the 16 mm collimator, (2) transit-radiation dose for the 8 and 4 mm collimators, (3) sector leakage within the radiation cavity and, (4) sector output uniformity. In these tests, the Elekta ABS phantom was used. A micropoint ion-chamber Exradin A16 was placed at the center of the phantom for all measurements. Results: With the version 8.0 of the control software of the MCU in the LGK PFX, the average flash-radiation dose per sector for the 16 mm collimator was measured to be 0.423 {+-} 0.003 cGy, and the average transit-radiation dose per sector for the 8 and 4 mm collimators was measured to be 0.169 {+-} 0.0009 and 0.147 {+-} 0.020 cGy, respectively. The calibration dose rate on the day of measurements was 280.8 cGy/min. Here, the authors have introduced a new concept of ''equivalent-time-duration'' (ETD) to represent the time duration, during which the flash-radiation or the transit-radiation dose is delivered. The ETD is a quotient of the measured dose of the flash-radiation or the transit-radiation and the respective calibrated dose rate for the 16, 8, or 4 mm collimator. The ETD constancy is an indicator of the constancy of the sector movements. The average value of ETD per sector was measured to be 724 {+-} 6, 313 {+-} 2, and 311 {+-} 45 ms for the 16, 8, and 4 mm collimators, respectively. During monthly spot checks, the authors have been measuring the total ETD for the flash-radiation when all eight sectors are open with the 16 mm collimator. The average value of the total ETD of the last 40 consecutive months was measured to be 642 {+-} 10 ms. This number is a useful quality parameter for the LGK PFX, which can be used to establish the base-line performance of the collimators of the LGK PFX. The reader is alerted that with the newly introduced version 9.0 of the control software of the MCU in the LGK PFX, the flash-radiation and the transit-radiation doses have become practically zero due to the fact that the treatment time is now corrected to compensate for these radiation doses. The sector output uniformity for the 16, 8, and 4 mm collimators was determined to be 98.9%, 97.3%, and 96.6%, respectively. The total leakage radiation with in the radiation cavity from all sectors was measured to be 0.17% of the dose output for the 16 mm collimator. Conclusions: Our measurements show that the dosimetric characteristics of all sectors of the LGK PFX are satisfactory. The authors recommend that the sector performance of the LGK PFX be determined initially at the time of installation of the LGK PFX and thereafter, at least annually. Similarly, our recommendation is that the total flash-radiation dose for the 16 mm collimator and the corresponding ETD value be measured on a monthly basis. Should any change in the sector movement occur, it will be revealed by the sector performance and the measurement of ETD.
The space shuttle advanced solid rocket motor: Quality control and testing
The Congressional committees that authorize the activities of NASA requested that the National Research Council (NRC) review the testing and quality assurance programs for the Advanced Solid Rocket Motor (ASRM) program. The proposed ASRM design incorporates numerous features that are significant departures from the Redesigned Solid Rocket Motor (RSRM). The NRC review concentrated mainly on these features. Primary among these are the steel case material, welding rather than pinning of case factory joints, a bolted field joint designed to close upon firing the rocket, continuous mixing and casting of the solid propellant in place of the current batch processes, use of asbestos-free insulation, and a lightweight nozzle. The committee's assessment of these and other features of the ASRM are presented in terms of their potential impact on flight safety.
Information quality-control model
Model serves as graphic tool for estimating complete product objectives from limited input information, and is applied to cost estimations, product-quality evaluations, and effectiveness measurements for manpower resources allocation. Six product quality levels are defined.
Practical quality control tools for curves and surfaces
Curves (geometry) and surfaces created by Computer Aided Geometric Design systems in the engineering environment must satisfy two basic quality criteria: the geometric shape must have the desired engineering properties; and the objects must be parameterized in a way which does not cause computational difficulty for geometric processing and engineering analysis. Interactive techniques are described which are in use at Boeing to evaluate the quality of aircraft geometry prior to Computational Fluid Dynamic analysis, including newly developed methods for examining surface parameterization and its effects.