Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION FALL OUT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Processes and properties of edge-localised instabilities in 2T 2MA plasmas in the Joint European Torus

During July 2012, 150 almost identical H-mode plasmas were consecutively created in the Joint European Torus, providing a combined total of approximately 8 minutes of steady-state plasma with 15 000 Edge Localised Modes (ELMs). In principle, each of those 15 000 ELMs are statistically equivalent. Here, the changes in edge density and plasma energy associated with those ELMs are explored, using the spikes in Beryllium II (527 nm) radiation as an indicator for the onset of an ELM. Clearly different timescales are observed during the ELM process. Edge temperature falls over a 2 ms timescale, edge density and pressure fall over a 5 ms timescale, and there is an additional 10 ms timescale that is consistent with a resistive relaxation of the plasma's edge. The statistical properties of the energy and density losses due to the ELMs are explored. For these plasmas the ELM energy (δE) is found to be approximately independent of the time between ELMs, despite the average ELM energy (〈δE〉) and average ELM frequency (f) being consistent with the scaling of 〈δE〉∝1/f. Instead, beyond the first 0.02 s of waiting time between ELMs, the energy losses due to individual ELMs are found to be statistically the same. Surprisingly no correlation is found between the energies of consecutive ELMs either. A weak link is found between the density drop and the ELM waiting time. Consequences of these results for ELM control and modelling are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Asymmetry effects in fragment production

The production of different fragments has been studied by taking into account the mass asymmetry of the reaction and employing the momentum dependent interactions. Two different set of asymmetric reactions have been analyzed while keeping At{sub otal} fixed using soft momentum dependent equation of state. Our results indicate that the impact of momentum dependent interactions is different in lighter projectile systems as compared to heavier ones. The comparative analysis of IQMD simulations with the experimental data in case of heavier projectile and lighter target system for the reaction of {sup 197}Au+{sup 27}Al (η = 0.7) at E = 600 MeV/nucleon shows that with the inclusion of MDI we are able, upto some extent, to reproduce the experimental universality of rise and fall of intermediate mass fragments (IMFs).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Influence of Anomalous Biomass Emissions on ENSO in CESM2

Abstract The influence of biomass burning (BB) aerosols arising from wildfires and agricultural fires on the transient coupled evolution of El Niño–Southern Oscillation (ENSO) is explored in Community Earth System Model, version 2 (CESM2). For both El Niño and La Niña, two 20-member ensembles are generated from initial states that are predisposed to evolve into ENSO events. For each ENSO phase, one ensemble is forced with the observed BB emissions during satellite-era ENSO events while the other is forced with a climatological annual cycle, with the responses to anomalous BB emissions estimated from interensemble differences. It is found that the regional responses to anomalous BB emissions occur mainly during boreal fall, which is also the time of the climatological seasonal maximum in emissions. Transient responses are identified in precipitation, clouds, and radiation in both the tropics and extratropics. At the onset of El Niño, these include increased precipitation in the northern branch of the intertropical convergence zone (ITCZ) and an enhancement of cloud albedo and amount across the Maritime Continent and eastern subtropical Pacific Ocean. Additional responses are identified through the course of El Niño and successive La Niña events, the net effect of which is to strengthen sea surface temperature (SST) anomalies in the eastern Pacific Ocean during El Niño and warm the tropical Pacific Ocean during La Niña. These responses improve the simulation of ENSO power, diversity, and asymmetry in CESM2. Significance Statement Biomass burning emissions from both wildfires and agricultural fires during ENSO act as a climate feedback, as they are both driven by fire weather anomalies tied to ENSO and influence clouds, radiation, and precipitation on a global scale. While the largest biomass burning (BB) emissions emanate mainly from Indonesia, other regions also exhibit systematic responses. When simulated in CESM2, the emissions collectively impact the flows of energy across the tropical Pacific Ocean in a spatially and temporally complex fashion, with the net effect of improving CESM2’s simulation of ENSO events.

Fasullo, John T. [National Center for Atmospheric ↗

Radiation from an accelerated quark via AdS/CFT correspondence

In this paper we investigate radiation by an accelerated quark in a strongly coupled gauge theory via anti-de Sitter/conformal field theory (AdS/CFT) correspondence. According to the AdS/CFT dictionary, we can read off the energy density or energy flux of the radiation from the asymptotic gravitational field in AdS bulk sourced by an accelerated string trailing behind the quark. In the case of an oscillating quark with frequency {omega}, we show that the time averaged energy density is asymptotically isotropic, and it falls off as (g{sub YM}{sup 2}N){sup 1/2}{omega}{sup 4}/R{sup 2} with distance R from the source. In a toy model of a scattered quark by an external field, we simply estimate the Poynting vector by the bremsstrahlung radiation and show that the energy flux is anisotropic outgoing radiation. Based on these investigations, we discuss the properties of strongly coupled gauge theory radiation in comparison with electromagnetic radiation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Properties of the Intergalactic Magnetic Field Constrained by Gamma-Ray Observations of Gamma-Ray Bursts

The magnetic field in intergalactic space gives important information about magnetogenesis in the early universe. The properties of this field can be probed by searching for radiation of secondary e {sup +} e {sup −} pairs created by TeV photons that produce GeV range radiation by Compton-scattering cosmic microwave background photons. The arrival times of the GeV “echo” photons depend strongly on the magnetic field strength and coherence length. A Monte Carlo code that accurately treats pair creation is developed to simulate the spectrum and time-dependence of the echo radiation. The extrapolation of the spectrum of powerful gamma-ray bursts (GRBs) like GRB 130427A to TeV energies is used to demonstrate how the intergalactic magnetic field can be constrained if it falls in the 10{sup −21}–10{sup −17} G range for a 1 Mpc coherence length.

79 ASTRONOMY AND ASTROPHYSICS↗

Integrated Circuit Design for Radiation-Hardened Charge-Sensitive Amplifier Survived up to 2 Mrad

According to the continuous development of metal-oxide semiconductor (MOS) fabrication technology, transistors have naturally become more radiation-tolerant through steadily decreasing gate-oxide thickness, increasing the tunneling probability between gate-oxide and channel. Unfortunately, despite this radiation-hardened property of developed transistors, the field of nuclear power plants (NPPs) requires even higher radiation hardness levels. Particularly, total ionizing dose (TID) of approximately 1 Mrad could be required for readout circuitry under severe accident conditions with 100 Mrad around a reactor in-core required. In harsh radiating environments such as NPPs, sensors such as micro-pocket-fission detectors (MPFD) would be a promising technology to be operated for detecting neutrons in reactor cores. For those sensors, readout circuits should be fundamentally placed close to sensing devices for minimizing signal interferences and white noise. Therefore, radiation hardening ability is necessary for the circuits under high radiation environments. This paper presents various integrated circuit designs for a radiation hardened charge-sensitive amplifier (CSA) by using SiGe 130 nm and Si 180 nm fabrication processes with different channel widths and transistor types of complementary metal-oxide-semiconductor (CMOS) and bipolar CMOS (BiCMOS). These circuits were tested under γ–ray environment with Cobalt-60 of high level activity: 490 kCi. The experiment results indicate amplitude degradation of 2.85%–34.3%, fall time increase of 201–1730 ns, as well as a signal-to-noise ratio (SNR) of 0.07–11.6 dB decrease with irradiation dose increase. These results can provide design guidelines for radiation hardening operational amplifiers in terms of transistor sizes and structures.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reaction-Induced Fracturing of Porous Carbonate Rocks during Volume-Increasing Replacement by Witherite

Volume-increasing replacement reactions can lead either to fracturing of the parent phase or to the formation of cohesive layers that passivate further reaction, but the factors that drive one outcome or the other are not understood. In this experimental study, we investigated the volume-increasing replacement of carbonate rocks (consisting of CaCO 3 and CaMg(CO 3 ) 2 ) of different porosity by witherite (BaCO 3 ). Samples were characterized using scanning electron microscopy, Raman spectroscopy, small-angle neutron/X-ray scattering, X-ray tomography, and scanning transmission electron microscopy. We observed the formation of a witherite reaction layer and witherite formation within pores and along grain boundaries. Despite this being a volume-increasing replacement reaction, newly formed witherite was porous, potentially allowing further replacement. Filled fractures were observed in the low-porosity carbonates, whereas witherite formed within pores in high-porosity carbonates. We conclude that fracturing of the parent phase versus passivation is contingent on the initial microstructure of the parent with an optimal degree of porosity required for fracturing.

Calcite↗

Emergent Relationships Among Sea Ice, Longwave Radiation, and the Beaufort High Circulation Exposed Through Parameter Uncertainty Analysis

Using a perturbed parameter ensemble of a coupled climate model, emerging relationships are identified between sea ice area, net surface longwave radiation, and the atmospheric circulation over the Beaufort gyre. There is a strong positive correlation between sea ice area and the net longwave radiation over the ocean-ice surface during the melting season and a negative correlation during the freezing season. The mechanisms responsible for the longwave radiation balance at the surface are mainly driven by sea ice variations in the freezing season and by clouds in the melting season. A strong positive (negative) correlation is also found between the fall (summer) total sea ice area in the Arctic and the sea level pressure over the Beaufort High region. It is argued that as sea ice coverage is lost, static stability losses are severe in fall, resulting in enhanced evaporation, vertical motions, and weakening of the general large-scale anticyclonic circulation of the Beaufort High.

54 ENVIRONMENTAL SCIENCES↗

The 0E2 benchmarks for PWR UO 2 decay heat: an analysis from the NEA WPNCS

This paper presents the work performed in the subgroup 16 of the Working Party for Nuclear Criticality Safety (WPNCS) of the OECD Nuclear Energy Agency. The main goal was to define two decay heat benchmarks for Spent Nuclear Fuel (one pincell and one assembly), perform calculations and compare and analyze the results in light of existing calorimetric measurements. The selected case is the PWR UO2 assembly 0E2, irradiated at the Ringhals-3 reactor and measured at the Clab facility in Sweden. In total, 21 institutes worldwide participated to the exercise, leading to 55 calculated results (named C). It was found that the measured decay heat values (E) can be satisfactorily reproduced with two-dimensional assembly calculations, leading to an average C/E value of 0.99, with an uncertainty (or one standard deviation) of ±0.01.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

CIRCUMBINARY MAGNETOHYDRODYNAMIC ACCRETION INTO INSPIRALING BINARY BLACK HOLES

We have simulated the magnetohydrodynamic evolution of a circumbinary disk surrounding an equal-mass binary comprising two non-spinning black holes during the period in which the disk inflow time is comparable to the binary evolution time due to gravitational radiation. Both the changing spacetime and the binary orbital evolution are described by an innovative technique utilizing high-order post-Newtonian approximations. Prior to the beginning of the inspiral, the structure of the circumbinary disk is predicted well by extrapolation from Newtonian results: a gap of roughly two binary separation radii is cleared, and matter piles up at the outer edge of this gap as inflow is retarded by torques exerted by the binary; the accretion rate is roughly half its value at large radius. During inspiral, the inner edge of the disk initially moves inward in coordination with the shrinking binary, but-as the orbital evolution accelerates-the inward motion of the disk edge falls behind the rate of binary compression. In this stage, the binary torque falls substantially, but the accretion rate decreases by only 10%-20%. When the binary separation is tens of gravitational radii, the rest-mass efficiency of disk radiation is a few percent, suggesting that supermassive binary black holes could be very luminous at this stage of their evolution. Inner disk heating is modulated at a beat frequency comparable to the binary orbital frequency. However, a disk with sufficient surface density to be luminous may be optically thick, suppressing periodic modulation of the luminosity.

79 ASTRONOMY AND ASTROPHYSICS↗

Workshop introduction

The Department of Energy's National Nuclear Security Administration's Global Threat Reduction Initiative (GTRI) has three subprograms that directly reduce the nuclear/radiological threat; Convert (Highly Enriched Uranium), Protect (Facilities), and Remove (Materials). The primary mission of the Off-Site Source Recovery Project (OSRP) falls under the 'Remove' subset. The purpose of this workshop is to provide a venue for joint-technical collaboration between the OSRP and the Nuclear Radiation Safety Service (NRSS). Eisenhower's Atoms for Peace initiative and the Soviet equivalent both promoted the spread of the paradoxical (peaceful and harmful) properties of the atom. The focus of nonproliferation efforts has been rightly dedicated to fissile materials and the threat they pose. Continued emphasis on radioactive materials must also be encouraged. An unquantifiable threat still exists in the prolific quantity of sealed radioactive sources (sources) spread worldwide. It does not appear that the momentum of the evolution in the numerous beneficial applications of radioactive sources will subside in the near future. Numerous expert studies have demonstrated the potentially devastating economic and psychological impacts of terrorist use of a radiological dispersal or emitting device. The development of such a weapon, from the acquisition of the material to the technical knowledge needed to develop and use it, is straightforward. There are many documented accounts worldwide of accidental and purposeful diversions of radioactive materials from regulatory control. The burden of securing sealed sources often falls upon the source owner, who may not have a disposal pathway once the source reaches the end of its useful life. This disposal problem is exacerbated by some source owners not having the resources to safely and compliantly store them. US Nuclear Regulatory Commission (NRC) data suggests that, in the US alone, there are tens of thousands of high-activity (IAEA Category I and II) sources in thousands of devices; and there are many more tens of thousands of smaller sources scattered among thousands of other NRC licensees. As a result of the ubiquitous nature and undeterminable number of current and legacy sources, even in developed countries they can be abandoned, disposed of in a haphazard manner, lost, stolen, and/or otherwise fallout of regulatory control. Supply and demand of sources, being market based, is more or less fluid. Normative security of radioactive sources exists, but varies in each country, and is loosely implemented through non-legally binding recommendations and standards provided by International Atomic Energy Agency technical documents and cooperation and through bilateral efforts such as this workshop where we share best-practices with one another. Much of the reason for the difficulty in securing sealed sources rests in the enormous need for their beneficial applications in the medical, industrial, and agricultural sectors. Alternative technologies to replace high-risk sources continue to be explored, but very few of these alternative solutions have reached the development stage for common usage and distribution. The beneficial uses of sources must be allowed to continue; however, to minimize the potential for their misuse, current controls and regulating mechanisms must be constantly evaluated to ensure the benefits gained outweigh potential risks. From a global perspective, an evaluation and modification of requirements over the entire life cycle of sources from their manufacture to their final disposition is required. The proper removal and disposal of vulnerable disused or orphan sources is essential to maintaining a safe operating environment. One of our goals in this workshop is to share our methodologies for recovering sources and learn how they differ or are similar to the challenges faced in recovering, storing, and disposing of sources in the Republic of Georgia . The suggestions we will make are flexible in allowing for the imperfect situations and capabilities we have all encountered in source recovery efforts. We have designed a table-top exercise specifically to address your concerns about the prevention and mitigation of contaminated facilities, soil, containers, and sources. Our discussion begins with an overview and video of the OSRP along with a brief on our projects ongoing international cooperation and activities. A presentation will be given by the NRSS illustrating the successes and challenges of source management in Georgia. A brief overview will be given of selected significant cases of the intentional misuse of sources. This will be followed by two comprehensive discussions focusing on the decontamination from the facility perspective down to the issues of container and source leakage. The second day will begin with the abovementioned table-top exercise on contamination control. On the third day, a second presentation from the NRSS will open up the session.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

WE-A-BRC-00: The Quality Gap

Quality and safety in healthcare are inextricably linked. There are compelling data that link poor quality radiation therapy to inferior patient survival. Radiation Oncology clinical trial protocol deviations often involve incorrect target volume delineation or dosing, akin to radiotherapy incidents which also often involve partial geometric miss or improper radiation dosing. When patients with radiation protocol variations are compared to those without significant protocol variations, clinical outcome is negatively impacted. Traditionally, quality assurance in radiation oncology has been driven largely by new technological advances, and safety improvement has been driven by reactive responses to past system failures and prescriptive mandates recommended by professional organizations and promulgated by regulators. Prescriptive approaches to quality and safety alone often do not address the huge variety of process and technique used in radiation oncology. Risk-based assessments of radiotherapy processes provide a mechanism to enhance quality and safety, both for new and for established techniques. It is imperative that we explore such a paradigm shift at this time, when expectations from patients as well as providers are rising while available resources are falling. There is much we can learn from our past experiences to be applied towards the new risk-based assessments. Learning Objectives: Understand the impact of clinical and technical quality on outcomes Understand the importance of quality care in radiation oncology Learn to assess the impact of quality on clinical outcomes D. Followill, NIH Grant CA180803.

60 APPLIED LIFE SCIENCES↗

WE-A-BRC-01: Introduction to the Certificate Course

Quality and safety in healthcare are inextricably linked. There are compelling data that link poor quality radiation therapy to inferior patient survival. Radiation Oncology clinical trial protocol deviations often involve incorrect target volume delineation or dosing, akin to radiotherapy incidents which also often involve partial geometric miss or improper radiation dosing. When patients with radiation protocol variations are compared to those without significant protocol variations, clinical outcome is negatively impacted. Traditionally, quality assurance in radiation oncology has been driven largely by new technological advances, and safety improvement has been driven by reactive responses to past system failures and prescriptive mandates recommended by professional organizations and promulgated by regulators. Prescriptive approaches to quality and safety alone often do not address the huge variety of process and technique used in radiation oncology. Risk-based assessments of radiotherapy processes provide a mechanism to enhance quality and safety, both for new and for established techniques. It is imperative that we explore such a paradigm shift at this time, when expectations from patients as well as providers are rising while available resources are falling. There is much we can learn from our past experiences to be applied towards the new risk-based assessments. Learning Objectives: Understand the impact of clinical and technical quality on outcomes Understand the importance of quality care in radiation oncology Learn to assess the impact of quality on clinical outcomes D. Followill, NIH Grant CA180803.

60 APPLIED LIFE SCIENCES↗

WE-A-BRC-02: Lessons Learned: Clinical Trials and Operations

Quality and safety in healthcare are inextricably linked. There are compelling data that link poor quality radiation therapy to inferior patient survival. Radiation Oncology clinical trial protocol deviations often involve incorrect target volume delineation or dosing, akin to radiotherapy incidents which also often involve partial geometric miss or improper radiation dosing. When patients with radiation protocol variations are compared to those without significant protocol variations, clinical outcome is negatively impacted. Traditionally, quality assurance in radiation oncology has been driven largely by new technological advances, and safety improvement has been driven by reactive responses to past system failures and prescriptive mandates recommended by professional organizations and promulgated by regulators. Prescriptive approaches to quality and safety alone often do not address the huge variety of process and technique used in radiation oncology. Risk-based assessments of radiotherapy processes provide a mechanism to enhance quality and safety, both for new and for established techniques. It is imperative that we explore such a paradigm shift at this time, when expectations from patients as well as providers are rising while available resources are falling. There is much we can learn from our past experiences to be applied towards the new risk-based assessments. Learning Objectives: Understand the impact of clinical and technical quality on outcomes Understand the importance of quality care in radiation oncology Learn to assess the impact of quality on clinical outcomes D. Followill, NIH Grant CA180803.

60 APPLIED LIFE SCIENCES↗

WE-A-BRC-03: Lessons Learned: IROC Audits

Quality and safety in healthcare are inextricably linked. There are compelling data that link poor quality radiation therapy to inferior patient survival. Radiation Oncology clinical trial protocol deviations often involve incorrect target volume delineation or dosing, akin to radiotherapy incidents which also often involve partial geometric miss or improper radiation dosing. When patients with radiation protocol variations are compared to those without significant protocol variations, clinical outcome is negatively impacted. Traditionally, quality assurance in radiation oncology has been driven largely by new technological advances, and safety improvement has been driven by reactive responses to past system failures and prescriptive mandates recommended by professional organizations and promulgated by regulators. Prescriptive approaches to quality and safety alone often do not address the huge variety of process and technique used in radiation oncology. Risk-based assessments of radiotherapy processes provide a mechanism to enhance quality and safety, both for new and for established techniques. It is imperative that we explore such a paradigm shift at this time, when expectations from patients as well as providers are rising while available resources are falling. There is much we can learn from our past experiences to be applied towards the new risk-based assessments. Learning Objectives: Understand the impact of clinical and technical quality on outcomes Understand the importance of quality care in radiation oncology Learn to assess the impact of quality on clinical outcomes D. Followill, NIH Grant CA180803.

60 APPLIED LIFE SCIENCES↗

HDG-1 Fiber Bragg grating data analysis

The main goal of the High dose graphite 1 Advanced test reactor experiment was to study nuclear grade graphite at high fluences. Additional supplementary optical fiber instrumentation was added to this long duration experiment for instrumentation development purposes. The supplementary instrumentation consisted of two pure silica core, fluorine doped cladding optical fibers each etched with 9 fiber Bragg gratings, one fiber being heat treated for 9 hours at 750 C and 16 hours at 750 C, the other being heat treated for 24 hours at 550 C and 48 hours at 650 C. Fiber Bragg gratings are known to have issues of measurement drift when in high temperature and high radiation environments like what is encountered in the Advanced test reactor. At the culmination of this experiment, the optical fibers saw ~1.3E21 n/cm2 total fluence, which is at the highest fluences that fiber Bragg gratings have been studied to date. Reported here is the analysis of this data including radiation induced shift and changes in sensitivity.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Radiation-Induced Damage of Silicon-Carbide Diodes by High-Energy Particles

The radiation hardness of three types of commercial Schottky rectifier diodes based on silicon carbide (4H-SiC, base layer doping level (3–7) × 10{sup 15} cm{sup –3}) under electron (0.9 or 3.5 MeV electrons) and proton irradiation (15 MeV protons) is studied. The forward and reverse current–voltage characteristics of the diodes are monitored. In the initial state, the diodes have a breakdown voltage of 1–2 kV and an almost ideal forward current–voltage characteristic. It is found that the series resistance of the diodes is the most sensitive to radiation and governs the radiation hardness. This resistance grows by nearly 10 orders of magnitude and reaches a value of 10{sup 9} Ω at high doses. The threshold doses of electron irradiation fall within the range D{sub th} ≈ (0.5–2) × 10{sup 16} cm{sup –2} and depend on the electron energy and doping level of the base layer, and those of proton irradiation, D{sub th} ≈ 5 × 10{sup 13} cm{sup –2}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Estimation of the Mass Absorption Cross Section of the Organic Carbon Component of Aerosols in the Mexico City Metropolitan Area

Data taken from the MCMA-2003 and the 2006 MILAGRO field campaigns are used to examine the absorption of solar radiation by the organic component of aerosols. Using irradiance data from an Multi-Filter Rotating Shadowband Radiometer (MFRSR) and an actinic flux spectroradiometer, we find aerosol single scattering albedo, ω - 0,λ, as a function of wavelength, λ. We find that in near-UV spectral range (defined here as 250 nm to 400 nm) ω - 0,λ is much lower compared to ω - 0,λ at 500 nm suggesting enhanced absorption in the near-UV range. Absorption by elemental carbon, dust, or gas cannot account for this enhanced absorption leaving only the organic part of the aerosol to account for it. We use data from a surface deployed Aerodyne Aerosol Mass Spectrometer (AMS) along with the inferred ω - 0,λ to estimate the Mass Absorption Cross-section (MAC) for the organic carbon. We find that the MAC is about 10.5 m2/g at 300 nm and falls close to zero at about 500 nm; values that are roughly consistent with other estimates of organic carbon MAC. These MAC values can be considered as “radiatively correct” because when used in radiative transfer calculations the calculated irradiances match the measured irradiances at the wavelengths considered here. The uncertainties of individual estimates are quite large, ±30% at 300 nm for the random error, and even larger for a worst-case estimate of the systematic error, ±80%. The error represents the unusual circumstance where no error cancellation is permitted, and is unlikely ever to be realized.

54 ENVIRONMENTAL SCIENCES↗