Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Prediction and measurement of radiation damage to CMOS devices on board spacecraft

The initial results obtained from the Complementary Metal Oxide Semiconductors Radiation Effects Measurement experiment are presented. Predictions of radiation damage to C-MOS devices are based on standard environment models and computational techniques. A comparison of the shifts in CMOS threshold potentials, that is, those measured in space to those obtained from the on the ground simulation experiment with Co 60, indicated that the measured space damage is greater than predicted by a factor of two for shields thicker than 100 mils (2.54 mm), but agrees well with predictions for the thinner shields.

Cliff, R. A.↗

Novel On-wafer Radiation Pattern Measurement Technique for MEMS Actuator Based Reconfigurable Patch Antennas

The paper presents a novel on-wafer, antenna far field pattern measurement technique for microelectromechanical systems (MEMS) based reconfigurable patch antennas. The measurement technique significantly reduces the time and the cost associated with the characterization of printed antennas, fabricated on a semiconductor wafer or dielectric substrate. To measure the radiation patterns, the RF probe station is modified to accommodate an open-ended rectangular waveguide as the rotating linearly polarized sampling antenna. The open-ended waveguide is attached through a coaxial rotary joint to a Plexiglas(Trademark) arm and is driven along an arc by a stepper motor. Thus, the spinning open-ended waveguide can sample the relative field intensity of the patch as a function of the angle from bore sight. The experimental results include the measured linearly polarized and circularly polarized radiation patterns for MEMS-based frequency reconfigurable rectangular and polarization reconfigurable nearly square patch antennas, respectively.

Simons, Rainee N.↗

Simulation of a numerical filter for enhancing earth radiation budget measurements

The Earth Radiation Budget Experiment has the objective to collect the radiation budget data which are needed to determine the radiation budget at the top of the atmosphere (TOA) on a regional scale. A second objective is to determine the accuracy of the results. Three satellites will carry wide and medium field of view radiometers which measure the longwave and shortwave components of radiation. Scanning radiometers will be included to detect small spatial features. A proposal has been made to employ for the nonscanning radiometers a one-dimensional numerical filter which reduces satellite measurements to TOA radiant excitances. The numerical filter was initially formulated by House (1980). It enhances the resolution of the radiation budget along the satellite groundtrack. The accuracy of the numerical filter estimate is studied by simulating the data gathering and measurement inversion process. The results of the study are discussed, taking into account two error sources.

Green, R. N.↗

Radiation budget measurements for the eighties and nineties

The Earth Radiation Budget Experiment (ERBE) consisted of a scanning radiometer and non-scanning radiometers on each of three spacecraft. These instruments began flying in October 1984. The nonscanning radiometers continue to operate, providing broadband radiation measurements of the Earth's outgoing longwave radiation and reflected solar radiation, in addition to measurements of the solar output. The Clouds and Earth Radiant Energy System (CERES) features a scanning radiometer, which is an improved version of the ERBE scanning radiometer, and will fly on the Tropical Rainfall Measurement Mission and Earth Observation System platforms in the late nineties. The CERES project will provide not only radiant fluxes at the 'top of the atmosphere' (TOA), but also at the surface and will compute radiant flux divergence through the atmosphere.

Smith, G. L.↗

Measuring the large-scale anisotropy in the microwave background radiation

Measurements of large-scale anisotropy in the 2.7 K microwave background radiation are reaching a sensitivity of Delta T/T = 0.0001 in the amplitudes of low-order spherical harmonics. At this level, interesting conditions and processes in the early universe can be studied. However, the measurements are difficult and very susceptible to systematic errors. The microwave instruments and techniques are discussed with the emphasis on the reduction and evaluation of spurious effects. The subtraction of foreground radiation, mainly from diffuse Galactic sources, is a major problem that already limits the accuracy of measurements near 1 cm wavelength. Current results for the dipole and quadrupole moments are compared and discussed.

Wilkinson, D. T.↗

Radiation Pressure Measurements on Micron-Size Individual Dust Grains

Measurements of electromagnetic radiation pressure have been made on individual silica (SiO2) particles levitated in an electrodynamic balance. These measurements were made by inserting single charged particles of known diameter in the 0.2- to 6.82-micron range and irradiating them from above with laser radiation focused to beam widths of approximately 175- 400 microns at ambient pressures particle due to the radiation force is balanced by the electrostatic force indicated by the compensating dc potential applied to the balance electrodes, providing a direct measure of the radiation force on the levitated particle. Theoretical calculations of the radiation pressure with a least-squares fit to the measured data yield the radiation pressure efficiencies of the particles, and comparisons with Mie scattering theory calculations provide the imaginary part of the refractive index of SiO2 and the corresponding extinction and scattering efficiencies.

Abbas, M. M.↗

Radiation Pressure Measurements on Micron Size Individual Dust Grains

Measurements of electromagnetic radiation pressure have been made on individual silica (SiO2) particles levitated in an electrodynamic balance. These measurements were made by inserting single charged particles of known diameter in the 0.2 micron to 6.82 micron range and irradiating them from above with laser radiation focused to beam-widths of approx. 175-400 micron, at ambient pressures approx. 10(exp -3) to 10(exp -4) torr. The downward displacement of the particle due to the radiation force is balanced by the electrostatic force indicated by the compensating dc potential applied to the balance electrodes, providing a direct measure of the radiation force on the levitated particle. Theoretical calculations of the radiation pressure with a least-squares fit to the measured data yield the radiation pressure efficiencies of the particles, and comparisons with Mie scattering theory calculations provide the imaginary part of the refractive index of silica and the corresponding extinction and scattering efficiencies.

Abbas, M. M.↗

Direct measurements by Voyagers 1 and 2 of the polarization of terrestrial kilometric radiation

Measurements of the polarization of intense terrestrial kilometric radiation obtained with planetary radio astronomy experiments on Voyager-1 and 2 during the early portions of each flight show the signals to be predominantly left-hand circularly polarized. Since these emissions were most probably generated above the Northern Hemisphere auroral zone, we conclude that the radiation is emitted primarily in the extraordinary mode.

Kaiser, M. L.↗

A Hypothesis on Biological Protection from Space Radiation Through the Use of New Therapeutic Gases as Medical Counter Measures

Radiation exposure to astronauts could be a significant obstacle for long duration manned space exploration because of current uncertainties regarding the extent of biological effects. Furthermore, concepts for protective shielding also pose a technically challenging issue due to the nature of cosmic radiation and current mass and power constraints with modern exploration technology. The concern regarding exposure to cosmic radiation is the biological damage it induces. As damage is associated with increased oxidative stress, it is important and would be enabling to mitigate and/or prevent oxidative stress prior to the development of clinical symptoms and disease. This paper hypothesizes a "systems biology" approach in which a combination of chemical and biological mitigation techniques are used conjunctively. It proposes using new, therapeutic, medical gases as both chemical radioprotectors for radical scavenging and biological signaling molecules for management of the body s response to exposure. From reviewing radiochemistry of water, biological effects of CO, H2, NO, and H2S gas, and mechanisms of radiation biology, it is concluded that this approach may have great therapeutic potential for radiation exposure. Furthermore, it also appears to have similar potential for curtailing the pathogenesis of other diseases in which oxidative stress has been implicated including cardiovascular disease, cancer, chronic inflammatory disease, hypertension, ischemia/reperfusion injury, acute respiratory distress syndrome, Parkinson s and Alzheimer s disease, cataracts, and aging.

Schoenfeld, Michael P.↗

Calorimeter accurately measures thermal radiation energy

Calorimeter accurately measures steady-state and transient, low-level thermal radiation energy. The calorimeter uses a compensating shield between the sensor and the calorimeter mount to intercept sensor heat losses and to provide a reference for determining a correction factor.

Anderson, W. W., Jr.↗