Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION SOURCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

A new method for diagnosing effective radiative forcing from aerosol–cloud interactions in climate models

Aerosol–cloud interactions (ACIs) are a leading source of uncertainty in estimates of the historical effective radiative forcing (ERF). One reason for this uncertainty is the difficulty in estimating the ERF from aerosol–cloud interactions (ERFaci) in climate models, which typically requires multiple calls to the radiation code. Most commonly used methods also cannot disentangle the contributions from different processes to ERFaci. Here, we develop a new, computationally efficient method for estimating the shortwave (SW) ERFaci from liquid clouds using histograms of monthly averaged cloud fraction partitioned by cloud droplet effective radius (r e ) and liquid water path (LWP). Multiplying the histograms with SW cloud radiative kernels gives the total SW ERFaci from liquid clouds, which can be decomposed into contributions from the Twomey effect, LWP adjustments, and cloud fraction (CF) adjustments. We test the method with data from five CMIP6-era models, using the Moderate Resolution Imaging Spectroradiometer (MODIS) satellite instrument simulator to generate the histograms. Our method gives similar total SW ERFaci estimates to other established methods in regions of prevalent liquid cloud and indicates that the Twomey effect, LWP adjustments, and CF adjustments have contributed -0.34 ± 0.23, -0.22 ± 0.13, and -0.09 ± 0.11 W m -2 , respectively, to the effective radiative forcing of the climate since 1850 in the ensemble mean (95 % confidence). These results demonstrate that widespread adoption of a MODIS r e –LWP joint histogram diagnostic would allow the SW ERFaci and its components to be quickly and accurately diagnosed from climate model outputs, a crucial step for reducing uncertainty in the historical ERF.

54 ENVIRONMENTAL SCIENCES↗

Modeling and simulation study for the design of the Fuel Interrogation and Examination using Submersible Tomography Analysis Mk II instrument

Here, the design of a submersible, gamma-ray tomography system for imaging irradiated nuclear fuel is described. The system—named Fuel Interrogation and Examination using Submersible Tomography Analysis (FIESTA) Mk. II—is a variation on a previous Mk. I I design, which was developed to non-destructively image fuel capsules irradiated in the Advanced Test Reactor at the Idaho National Laboratory. The FIESTA system uses a combination of transmission computed tomography and emission computed tomography to image the restructuring and fission product migration at different points of burnup. Changes made to FIESTA Mk. I reflect the revised design requirements and a need to reduce background noise, largely originating from downscattered photons from fuel and transmission source. The computational design and radiation transport simulations are described.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Effects of non-monochromaticity in laboratory XPS: Representative example of pyrimidine

The Mg and Al K α radiation used in standard laboratory sources for X-Ray Photoelectron Spectroscopy, XPS, is not naturally monochromatic because the spin orbit splitting of the Mg and Al 2p shells is not normally resolved. However, since the 2p spin-orbit splitting of the K α1 and K α2 X-Rays in these light atoms is small, it is normally ignored. In the present work, the consequences of the departure from monochromaticity is explicitly shown to be extremely small for the representative case of the C(1 s) ionizations in the XPS of the pyrimidine molecule. Furthermore, this conclusion is general and does not depend on the particular molecule studied since the K α1 and K α2 BE splittings reflect the spin-orbit splittings in the X-Ray source.

Binding Energies (BEs)↗

Radiation Effects on Uranyl Tetrachloro Coordination Compounds: Impact of Lattice Water

Nuclear materials, such as uranium-bearing solids, are exposed to high levels of ionizing radiation throughout the nuclear fuel cycle; thus, it is important to develop a molecular-level understanding of how these materials behave and degrade in the presence of gamma (γ) irradiation. In the current study, three U(VI) tetrachloride complexes, M 2 [UO 2 Cl 4 ]·xH 2 O (where M = K + , Rb + , or Cs + and x = 0 or 2), and their respective chloride salts were exposed to 1–50 kGy of γ radiation using a 60 Co source. Irradiated materials were evaluated by using electron paramagnetic resonance (EPR) and Raman spectroscopy and were further explored by using density functional theory (DFT) methods. EPR spectra of the irradiated materials suggest the formation of a Cl-based radical for both the alkali salts and the uranyl tetrachloride compounds, and DFT calculations provide evidence that the Cl 2 –• radical is formed within these materials. The presence of water in the K + and Rb + compounds leads to additional spectroscopic signatures that could be traced back to water radiolysis and the formation of peroxide and superoxide species. DFT results support the formation of HO 2 • in the lattice and potentially the formation of a [UO 2 Cl 3 (O 2 )] 3– species, highlighting the impact of water within the hydrated material to alter U(VI) speciation by radiolysis.

36 MATERIALS SCIENCE↗

Implementation of an impurity diagnostic suite on the Pegasus-III experiment

A suite of diagnostics used to assess impurity content and dynamics has been updated, upgraded, and installed on the Pegasus-III Experiment. Typical plasma parameters during local helicity injection start-up are τ shot ~10 ms, n e ~ 1 × 10 19 m –3 , and T e ~ 50 eV. The deployed diagnostics are compatible with this modest temperature and density regime and provide species identification, source localization, and estimation of radiation losses. Impurity species are determined by recording time-evolving, single line-of-sight spectra at 1.25 kfps using a SPRED (Survey, Poor Resolution, Extended Domain) vacuum ultraviolet spectrometer. SPRED is equipped with 450 g/mm grating, giving a spectral resolution of 0.33 nm and a spectral range from ~10 to 110 nm, useful to identify light impurity species in this temperature and density range. An absolutely calibrated spectrometer that collects light from the plasma at R tan = 15.9 cm and Δt ≥ 2 ms is used as a visible survey spectrometer and for continuum measurements. The radiated power from the plasma is estimated with a photodiode-based diagnostic. Two 16-channel absolute extreme ultraviolet diode arrays are placed behind pinhole apertures, resulting in 32 lines of sight at Z = 0, with a spatial resolution of 2–3 cm and a time response of 60 kHz. A photometrically calibrated collinear D α /near infrared filtered photodiode-based system measures the D α emission and around 1040 nm. All these instruments have been designed to suppress electromagnetic interference from megawatt-class switching power supplies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Search for an Anomalous Excess of Single Photons in the MicroBooNE Neutrino Experiment

Neutrinos are some of the most elusive particles in the standard model, being incredibly common throughout the universe, but interacting with detectors incredibly rarely. Certain properties of neutrinos remain difficult to measure, including their masses, their CP violation properties, and whether or not they are their own antiparticles. Additionally, there have been several anomalous results in neutrino experiments which remain unexplained. MicroBooNE was built in order to study these anomalous results using a more capable detector technology, the Liquid Argon Time Projection Chamber. Specifically, MicroBooNE is able to search for an anomalous excess of low energy electromagnetic showers, which was previously observed by the MiniBooNE experiment. In particular, MicroBooNE is able to study whether the excess could consist of electron showers or photon showers. In this thesis, I describe a search for this anomalous excess by targeting neutral current Delta radiative decays, the largest expected source of single photons in MicroBooNE. We observe data consistent with our nominal expectation, but cannot rule out all potential sources of additional single photon events, particularly those with no visible proton activity. There remains significant potential to probe this channel in even more detail using MicroBooNE and other experiments in the near future.Hagaman, Lee

Hagaman, Lee [Chicago U.]↗

Activation of Insulation in Low Power Nuclear Experiments

Nuclear experiments aim to test new designs, procedures, and materials. Similar to conventional power reactors, potential sources of worker exposure to radiation is a primary concern. One such concern is the insulation materials that are used in or near the reactor, which can often create dust when being handled. If this material receives a substantial neutron dose, then it can become activated, which can pose a health risk if inhaled or ingested. This analysis looked at the activation of, and conservative dose estimates from, industrial grade insulations that may be used in a reactor experiment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Gallium oxide (Ga2O3) as a radiation detector distinguishing neutrons and gammas

Gallium oxide (Ga2O3) is a promising ultrawide bandgap semiconductor for radiation detection with the potential of integrating electronic and scintillation functions within a single crystal device. This study establishes the scintillation response of β-Ga2O3 gamma irradiation from yttrium-88 (88Y). Then, californium-252 (252Cf) is used as a spontaneous fission source of mixed neutron and gamma radiation field to measure scintillation signals. Pulse shape discrimination and constant fraction discrimination techniques were used to separate neutron and gamma interaction events. Further investigation indicates that the prompt temporal responses of β-Ga2O3 for gammas and neutrons may enable discrimination of the two by prompt pulse fitting methods, focused around the initial peak. For gamma irradiation, we observed a rise time (τr) of 2.1 ns, decay time (τd) of 9.5 ns, and a full width at half maximum (FWHM) of 6.2 ns. For neutrons, it showed a τr of 2.3 ns, a τd of 12.1 ns, 9.4 ns FWHM, and reduced peak intensity. A diamond detector exhibited a more symmetrical τr and τd for both gamma and neutron signals and therefore is less effective at discriminating between the two by this method. This draws attention to β-Ga2O3’s ability to distinguish neutron and gamma particles. These findings showcase Ga2O3’s potential as a next-generation semiconductor for applications in nuclear safety and medical imaging, where precise discrimination between neutron and gamma interactions is essential.

Valdes, D. J. (ORCID:0000000304373720)↗

Three-dimensional reconstruction of THz near-fields from a LiNbO3 optical rectification source

Terahertz (THz) generation by optical rectification in LiNbO3 (LN) is a widely used technique for generating intense THz radiation. The spatiotemporal characterization of THz pulses from these sources is currently limited to far-field methods. While simulations of tilted pulse front THz generation have been published, little work has been done to measure the near-field properties of the THz source. A better understanding of the THz near-field properties will improve optimization of THz generation efficiency, transport, and coupling. We demonstrate a technique for quantitative spatiotemporal characterization of single-cycle strong-field THz pulses with 2-D near-field electro-optic imaging. We have reconstructed the full temporal 3D THz near-field and shown how the phase front can be tailored by controlling the incident pump pulse.

Gabriel, Annika↗

RCEMIP‐ACI: Aerosol‐Cloud Interactions in a Multimodel Ensemble of Radiative‐Convective Equilibrium Simulations

Aerosol‐cloud interactions are a persistent source of uncertainty in climate research. This study presents findings from a model intercomparison project examining the impact of aerosols on clouds and climate in convection‐permitting radiative‐convective equilibrium (RCE) simulations. Specifically, 11 different modeling teams conducted RCE simulations under varying aerosol concentrations, domain configurations, and sea surface temperatures (SSTs). We analyze the response of domain‐mean cloud and radiative properties to imposed aerosol concentrations across different SSTs. Additionally, we explore the potential impact of aerosols on convective aggregation and large‐scale circulation in large‐domain simulations. The results reveal that the cloud and radiative responses to aerosols vary substantially across models. However, a common trend across models, SSTs, and domain configurations is that increased aerosol loading tends to suppress warm rain formation, enhance cloud water content in the mid‐troposphere, and consequently increase mid‐tropospheric humidity and upper‐tropospheric temperature, thereby impacting static stability. The warming of the upper troposphere can be attributed to reduced lateral entrainment effects due to the higher environmental humidity in the mid‐troposphere. However, models do not agree on aerosol impacts on convective updraft velocity based on the preliminary examination of high‐percentiles of vertical velocity at a single mid‐troposheric layer (500 hPa). In large‐domain simulations, where convection tends to self‐organize, aerosol loading does not consistently influence self‐organization but tends to reduce the intensity of large‐scale circulation forming between convective clusters and dry regions. This reduction in circulation intensity can be explained by the increase in static stability due to the upper tropospheric warming.

54 ENVIRONMENTAL SCIENCES↗

Solution-Processed Ultrafast, Room-Temperature Single-Photon Source at 1550 nm

Single photons are cornerstones of quantum technologies. The need for an ultrafast, bright, and stable photon source emitting in the telecom-band at ∼1550 nm, ideally operating at room temperature, has resulted in a decades-long quest. However, to date, telecom sources are hampered by inherently long radiative lifetimes that severely limit brightness and speed, material instability, or the need for cryogenic operation. Here, in this study, stable colloidal PbS/CdS quantum dots emitting at 1550 nm (C-band) or 1350 nm (O-band) are embedded in a solution-synthesized nanoparticle-on-mirror cavity. Single cavity-coupled quantum dots experience extreme Purcell factors up to 10,700, resulting in ultrafast emission lifetimes of 65 ps, along with near-complete blinking suppression. As a result, 12 million single photons are emitted per second affording a single photon source at 1550 nm that is more than two orders of magnitude brighter than previously possible at room-temperature. These telecom-band single photon sources are solution-processable and lithography-free and may leverage mature colloidal fabrication technologies for future quantum applications.

36 MATERIALS SCIENCE↗

Evaluating Radiation Impact on Transmon Qubits Using a Fast Decay Protocol in Above and Underground Laboratories

Superconducting qubits can be sensitive to sudden energy deposits caused by ambient radioactivity and cosmic rays. Previous studies have focused on understanding possible correlated effects over time and distance due to this radiation. In this study‚ for the first time‚ we directly compare the response of a transmon qubit measured initially at the SQMS above-ground facility (Fermilab‚ Illinois‚ USA) and then at the deep underground Gran Sasso Laboratory (INFN-LNGS‚ Italy). We observe the same average qubit lifetime of roughly 80 microseconds at both facilities. We then apply a fast decay detection protocol and investigate the time structure and relative rates of triggered events due to radiation versus intrinsic noise‚ comparing the above and underground performance of several high-coherence qubits. Using gamma sources of variable intensity we calibrate the response of the qubit to different levels of radiation in an environment with minimal background radiation. Results indicate that qubits respond to a strong gamma source‚ and it is possible to detect particle impacts. However‚ we do not observe a difference in radiation-induced-like events when comparing the above and underground results for niobium-based transmon qubits with sapphire substrates. We conclude that the majority of these events are not radiation-related and are attributed to other noise sources‚ which by far dominate single-qubit errors in modern transmon qubits. [1] Dominicis‚ Roy et al. arXiv:2405.18355

Roy, Tanay↗

Investigation of divertor detachment induced through neon seeding and density ramp on HL-3

A new self-consistent 1D scrape-off layer model has been recently developed in BOUT++ framework, named SD1D, which includes equations for various particle species (e.g. main plasma, neutrals and impurities) and couples open databases like ADAS and AMJUEL. It is able to quickly and effectively simulate divertor detachment experiments. In this work, a typical detachment experiment (shot #6270) on HL-3 with neon seeding is simulated using the SD1D code. It is found that the target electron temperature and the target ion saturation current in the simulations are consistent with experimental results measured by Langmuir probes on the target plate. The variation of D α radiation intensity in the divertor is qualitatively similar to the measured D α signal. Following the experimental validations, different upstream densities are set in the simulations to study the impurity distribution under different plasma density conditions. It is found that increasing upstream density can be helpful for the control of the neon radiation front (closer to the target). In this work we also compare two detachment regimes in simulations. Based on the same initial experimental parameters (shot #6270) on HL-3, a scan of upstream density and a scan of neon seeding rate are carried out respectively. It is found that the role of atomic and molecular processes is different in the two detachment regimes. The current density roll-over is ascribed to a drop in the divertor ion source, and the variation of D α radiation intensity via different excitation channels is associated with the relevant collisional reaction sources.

BOUT++↗

Radiation-resilient InAs quantum dot lasers

Displacement damage from particle radiation increases the threshold current of semiconductor lasers, impeding the deployment of photonic systems in harsh radiation environments. Replacing conventional quantum well (QW) gain regions with quantum dots (QDs) has been shown to suppress the radiation-induced increase in threshold current owing to three-dimensional carrier confinement, which effectively segregates charge carriers away from radiation-induced defects. However, radiation-induced change in threshold current is also affected by extrinsic design elements of a laser, such as photon lifetime, and therefore provides only a partial assessment of the radiation hardness. In this work, we advance the understanding of the radiation resiliency of InAs QD lasers by extracting the change in the nonradiative recombination rate after radiation exposure, which provides a more fundamental assessment of the intrinsic radiation hardness of InAs QD gain regions. We find that carriers that populate InAs QD states have a nonradiative recombination rate that is over an order-of-magnitude less sensitive to neutron radiation relative to carriers in InGaAsP QWs. InAs QD lasers must be designed such that carriers primarily occupy QD states, preventing carrier spillover into surrounding barrier layers to obtain the maximum benefit. Furthermore, we show that enhanced radiation hardness is observed in InAs QD lasers grown on both highly lattice-mismatched silicon substrates and native GaAs substrates, further broadening the appeal of InAs QD lasers as reliable light sources for photonic systems operating in harsh radiation environments.

47 OTHER INSTRUMENTATION↗

Evaluating Radiation Impact on Transmon Qubits in Above and Underground Facilities

Superconducting qubits can be sensitive to abrupt energy deposits caused by cosmic rays and ambient radioactivity. Previous studies have focused on understanding possible correlated effects over time and distance due to cosmic rays. In this study, for the first time, we directly compare the response of a transmon qubit measured initially at the Fermilab SQMS above-ground facilities and then at the deep underground Gran Sasso Laboratory (INFN-LNGS, Italy). We observe same average qubit lifetime T$_1$ of roughly 80 microseconds at above and underground facilities. We then apply a fast decay detection protocol and investigate the time structure, sensitivity and relative rates of triggered events due to radiation versus intrinsic noise, comparing above and underground performance of several high-coherence qubits. Using gamma sources of variable activity we calibrate the response of the qubit to different levels of radiation in an environment with minimal background radiation. Results indicate that qubits respond to a strong gamma source and it is possible to detect particle impacts. However, when comparing above and underground results, we do not observe a difference in radiation induced-like events for these sapphire and niobium-based transmon qubits. We conclude that the majority of these events are not radiation related and to be attributed to other noise sources which by far dominate single qubit errors in modern transmon qubits.

Roy, Tanay↗

Fixed Source Sensitivity Calculations for Inertial Confinement Fusion Applications

A numerical code library was developed for the radiation transport code MCNP6.3 to calculate generalized response sensitivity coefficients for fixed source neutron transport problems with applications to inertial confinement fusion (ICF) experiments. The new MCNP6.3 dependency is used to generate a novel time convolution response that represents a neutron time-of-flight (nToF) signal. The traditional suite of macroscopic cross-section sensitivities and constrained fixed source probability distribution sensitivities are available for both the standard and the new response tallies in this library. However, novel sensitivity coefficients for the constrained hyperparameters of analytic fixed source probability distributions are emphasized in this work for their connection to ICF neutron transport models. Particularly, advanced Monte Carlo methods are developed for calculating the sensitivity of a nToF signal to perturbations in an ICF plasma’s ion temperature and burn history as well as perturbations in the target liner mass density and the shape parameters of the nToF detector’s impulse response function. Together, these capabilities form an advanced suite of computational tools that can be used to analyze and extract information from any ICF experimental platform.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Emission and Suppression of Line Features in Luminous Transients

Featureless optical and ultraviolet (UV) spectra are a puzzling signature to emerge from recent observations of luminous fast blue optical transients (LFBOTs) and some tidal disruption events (TDEs). We describe the landscape of source and gas properties that are expected to form H, He I , and He II emission lines, and map spectral types to the parameter space of luminosity and system radius. Using one-dimensional radiative transfer calculations, we show that high source luminosities (L > 10 44 erg s −1 ) and compact ejecta radii (r < 10 14 cm) produce featureless spectra, due to the high temperature and ionization state of the emitting medium. Intermediate luminosities and moderately compact systems can generate He II -dominated spectra, while lower luminosities and more extended atmospheres result in conspicuous H and He I emission. Large expansion velocities (v ≥ 0.1c) can further broaden lines such that they blend into the continuum. Featureless UV spectra may require even more extreme ionization environments or velocities in order to suppress the many intrinsically strong metal lines at those wavelengths. Applying this framework to understand the absence of features observed in LFBOTs and featureless TDEs, we find that, under the optically thick, quasi-thermal conditions considered here, nonhomologous, compact outflows are likely necessary for featurelessness to persist in optical and UV spectra.

Aspegren, Olivia [University of California, Berkel↗

Commissioning a time-gated camera for fast neutron beamline spatial-energy characterization at LANSCE-WNR spallation source

An energy-resolved fast neutron beam imaging diagnostic has been successfully commissioned at the Weapons Neutron Research (WNR) spallation source within the Los Alamos Neutron Science Center (LANSCE) facility. This diagnostic replaces the existing analog phosphor image plates, which integrate across all neutron energies, as well as other particles, with a near-real-time energy-sensitive imaging capability. The system uses a fast plastic scintillator coupled with an intensified CCD camera. Specifically, the Teledyne Pi-MAX4 camera is coupled with either a 4 mm thick Eljen (EJ) 204 or 228 plastic scintillator. These scintillators are most sensitive to the fast neutrons (0.8-800 MeV) directly from the spallation source rather than low energy background radiation. Experimentally, these plastic scintillators were shown to have sufficiently fast decay to differentiate the bright gamma flash from the spallation neutrons. The spatial resolution is dominated by neutron beam divergence, with minimal additional contributions from scatter and light divergence. The system successfully resolved changes in neutron beam characteristics caused by intentional proton steering variations. Additionally, simulations of scintillator light yield as a function of thickness conducted using PHITS (with Scinful-QMD package) found that increasing scintillator thickness from 4 mm to 6 or 8 mm could potentially increase brightness ~ 3x. This may be explored if there is a need to reduce image acquisition time from several minutes to under one minute.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗