Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIOFREQUENCY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

249 records · Page 14

Fundamental investigation of unipolar and RF corona in atmospheric air

Here, unipolar (DC) and radio frequency (RF) corona at 3.3 MHz is studied at centimeter-sized gaps in a needle-plane geometry in atmospheric air at room temperature. Positive and negative corona using pure tungsten electrodes with varying tip angles revealed a lower onset voltage for the needle with the smaller included angle. The RF corona onset voltage and corresponding time delay were measured for a series of needles composed of pure tungsten or 2% lanthanated tungsten. The corona onset, established when the first instance of UV photon emission is detected via photomultiplier tube, occurred primarily during the negative half cycle of the applied RF voltage for pure tungsten needles. In contrast, with lanthanated tungsten needles, such preference was not observed. No distinguishable difference in onset voltage between pure tungsten and lanthanated tungsten was found, indicating that adding a small amount of lanthanum to tungsten has a negligible impact on the onset voltage at 3.3 MHz frequencies for electrodes at room temperature.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental observations of multiple modes of filamentary structures in the magnetized dusty plasma experiment (MDPX) device

Due to the small charge-to-mass ratio of dust particles, it is often necessary to use large magnetic fields of B ≥ 1 T, in order to observe the influence of magnetic forces in laboratory dusty plasmas. However, when experiments are performed at high magnetic fields in capacitively coupled, radio frequency discharges used for these dusty plasma experiments, the plasma is often observed to form filamentary structures between the electrodes that are aligned to the external magnetic field which disrupt the uniformity of the plasma and adversely impact some of our dusty plasma experiments. Recent experiments performed in the Magnetized Dusty Plasma Experiment device seek to identify and characterize these filamentary structures. This paper discusses the morphology of several distinct filamentary modes that are formed in low temperature argon plasmas. Three different spatial modes of filaments that appear to be strongly dependent on the magnetic field and neutral pressure are identified. There is strong evidence that each spatial mode has a threshold condition that is dependent on the ion Hall parameter. The criteria for the formation of the filaments are shown to be consistent with predictions of recent numerical simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Q-factor optimization for high-beta 650 MHz cavities for PIP-II

High Q-factors are of utmost importance to minimize losses of superconducting radio-frequency cavities deployed in continuous wave particle accelerators. This study elucidates the surface treatment that can maximize the Q-factors in high-beta 650 MHz elliptical niobium cavities. State-of-the-art surface treatments are applied in many single-cell cavities, and surface resistance studies are performed to understand the microwave dissipation at this unexplored frequency. The nitrogen doping treatment is confirmed to be necessary to maximize the Q-factors at medium RF fields. We applied this treatment in five-cell high-beta 650 MHz cavities and demonstrated that extremely high Q-factors were obtained at medium RF fields with this treatment. We also demonstrated that adding a cold electropolishing step after N-doping is crucial to push the quench field of multicell cavities to higher gradients.

43 PARTICLE ACCELERATORS↗

Characterization of self-magnetic pinch (SMP) radiographic diode performance on RITS-6 at Sandia National Laboratories. I. Diode dynamics, DC heating to extend radiation pulse

Radiographic diodes focus on an intense electron beam to a small spot size to minimize the source area of energetic photons for radiographic interrogation. The self-magnetic pinch (SMP) diode has been developed as such a source and operated as a load for the six-cavity radiographic integrated test stand (RITS-6) inductive voltage adder driver. While experiments support the generally accepted conclusion that a 1:1 aspect diode (cathode diameter equals anode–cathode gap) delivers optimum SMP performance, such experiments also show that reducing the cathode diameter, while reducing spot size, also results in reduced radiation dose, by as much as 50%, and degraded shot reproducibility. Analysis of the effective electron impingement angle on the anode converter with time made possible by a newly developed dose-rate array diagnostic indicates that fast-developing oscillations of the angle are correlated with early termination of the radiation pulse on many of the smaller-diameter SMP shots. This behavior as a function of relative cathode size persists through experiments with output voltages and currents up to 11.5 MV and 225 kA, respectively, and with spot sizes below approximately few millimeters. Since simulations to date have not predicted such oscillatory behavior, considerable discussion of the angle behavior of SMP shots is made to lend credence to the inference. We report there is clear anecdotal evidence that DC heating of the SMP diode region leads to stabilization of this oscillatory behavior. This is the first of two papers on the performance of the SMP diode on the RITS-6 accelerator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The ultrafast pixel array camera system and its applications in high energy density physics

Diagnostics in high energy density physics, shock physics, and related fields are primarily driven by a need to record rapidly time-evolving signals in single-shot events. These measurements are often limited by channel count and signal degradation issues on cable links between the detector and digitizer. Here we present the Ultrafast Pixel Array Camera (UPAC), a compact and flexible detector readout system with 32 waveform-recording channels at up to 10 Gsample/s and 1.8 GHz analog bandwidth. The compact footprint allows the UPAC to be directly embedded in the detector environment. A key enabling technology is the PSEC4A chip, an eight-channel switch-capacitor array sampling device with up to 1056 samples/channel. The UPAC system includes a high-density input connector that can plug directly into an application-specific detector board, programmable control, and serial readout, with less than 5 W of power consumption in full operation. We present the UPAC design and characterization, including a measured timing resolution of ~20 ps or better on acquisitions of sub-nanosecond pulses with minimal system calibrations. Example applications of the UPAC are also shown to demonstrate operation of a solid-state streak camera, an ultrafast imaging array, and a neutron time-of-flight spectrometer.

47 OTHER INSTRUMENTATION↗

Contactless excitation of acoustic resonance in insulating wafers

Contactless excitation and detection of high harmonic acoustic overtones in a thin insulator single crystal are described using radio frequency spectroscopy techniques. Single crystal [001] silicon wafer samples were investigated, one side covered with a Nb thin film, the common starting point for the fabrication of quantum devices. Additionally, the coupling between electromagnetic signals and mechanical oscillation is achieved from the Lorentz force generated by an external magnetic field. This method is suitable for any sample with a metallic surface or covered with a thin metal film. High resolution measurements of the temperature dependence of the sound velocity and elastic constants of silicon are reported and compared with known results.

47 OTHER INSTRUMENTATION↗

Similarity-based scaling networks for capacitive radio frequency discharge plasmas

We demonstrate similarity-based scaling networks for capacitive radio frequency (RF) plasmas, which extensively correlate discharge characteristics under varied conditions, incorporating the transition from original to similarity states. Based on fully kinetic particle-in-cell simulations, similar RF discharges in argon are demonstrated with three external control parameters (gas pressure, gap distance, and driving frequency) simultaneously tuned. A complete set of scaling pathways regarding fundamental discharge parameters is obtained, from which each plasma state finds its neighboring node with only one control parameter tuned. The results from this study provide a promising strategy for plasma multi-parameter mapping, enabling effective cross-comparisons, prediction, and manipulation of RF discharge plasmas.

36 MATERIALS SCIENCE↗

New generation bunch shape monitor for ion accelerators

Measuring longitudinal beam parameters is important for operation and development of high intensity linear accelerators, but it is notoriously difficult for proton and ion beams at non-relativistic energies. The Bunch Shape Monitor (BSM) is a device used for measuring the longitudinal bunch distribution in ion linacs. The existing BSM models have poor electron collection efficiency from the wire and are limited to one-dimensional measurements of the phase coordinate. In response to this problem, we have developed a new generation BSM with improved performance. The proposed design incorporates three major innovations: First, the collection efficiency was improved by adding a focusing field between the wire and the entrance slit, which will also allow measurements over a much wider dynamic range. Second, an improvement in the measurement speed was achieved by sampling longitudinal profiles of multiple energy slices simultaneously, where the BSM wire is placed at the exit of an ion spectrometer so that ions with different energies hit the wire at different horizontal coordinates along the wire. Finally, the design incorporates a motion system that can shift the wire and deflecting cavity together, enabling transverse profile measurements like a wire scanner. Here, in this paper, we will provide the design of the new BSM and report on its beam test results at the Spallation Neutron Source facility in Oak Ridge National Laboratory.

43 PARTICLE ACCELERATORS↗

Analysis of thermal grooving effects on vortex penetration in vapor-diffused Nb 3 Sn

While Nb 3 Sn theoretically offers better superconducting radio-frequency (RF) cavity performance (Q 0 and E acc ) to Nb at any given temperature, peak RF magnetic fields consistently fall short of the ~400 mT prediction. The relatively rough topography of vapor-diffused Nb 3 Sn is widely conjectured to be one of the factors that limit the attainable performance of Nb 3 Sn-coated Nb cavities prepared via Sn vapor diffusion. Here we investigate the effect of coating duration on the topography of vapor-diffused Nb 3 Sn on Nb and calculate the associated magnetic field enhancement and superheating field suppression factors using atomic force microscopy topographies. It is shown that the thermally grooved grain boundaries are major defects which may contribute to a substantial decrease in the achievable accelerating field. Further, the severity of these grooves increases with total coating duration due to the deepening of thermal grooves during the coating process.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Niobium's intrinsic coherence length and penetration depth revisited using low-energy muon spin spectroscopy and secondary-ion mass spectrometry

Here, we report direct, simultaneous measurements of the London penetration depth (𝜆 𝐿 ) and Bardeen-Cooper-Schrieffer coherence length (𝜉 0 ) in oxygen-doped niobium, with impurity concentrations spanning the “clean” to “dirty” limits. Two depth-resolved techniques—low-energy muon spin spectroscopy and secondary-ion mass spectrometry—were used to quantify the element's Meissner screening profiles, analyzed within a framework that accounts for nonlocal electrodynamics. The analysis indicates intrinsic length scales of 𝜆 𝐿 = 29.1⁢ (10)⁢ nm and 𝜉 0 = 39.9 ⁢(25)⁢ nm, corresponding to a Ginzburg-Landau parameter 𝜅 = 0.70⁢ (5). The obtained 𝜆 𝐿 and 𝜅 values, accurately quantified at the nanoscale, are smaller than those commonly used in applications and modeling, and indicate that clean niobium lies at the boundary between type-I and type-II superconductivity, supporting the contemporary view that its intrinsic state may be type I.

Particle Accelerator↗

Loop Antennas for Use On/Off Ground Planes

Many applications benefit from the ability of an RFID tag to operate both on and off a conducting ground plane. This paper presents an electrically small loop antenna at 433 MHz that passively maintains its free-space tune and match when located a certain distance away from a large conducting ground plane. The design achieves this using a single radiation mechanism (that of a loop) in both environments without the use of a ground plane or EBG/AMC structure. An equivalent circuit model is developed that explains the dual-environment behavior and shows that the geometry balances inductive and capacitive parasitics introduced by the ground plane such that the free-space loop reactance, and thus resonant frequency, does not change. A design equation for balancing the inductive and capacitive parasitic effects is derived. Finally, experimental data showing the design eliminates ground plane detuning in practice is presented. The design is suitable for active, “hard” RFID tag applications.

42 ENGINEERING↗

FEgen (v.1): Field Emission Distribution Generator Freeware Based on Fowler–Nordheim Equation

This work presents an open-source code, FEgen, that generates initial field emission distributions based on the time-dependent Fowler–Nordheim equation. Current in-demand and open-source beam tracking software—such as ASTRA, IMPACT-T, and GPT—do not contain native distribution generator functions suitable for field emitted electron tracking and phase space analysis. Furthermore, the intuitive graphical user interface of FEgen generates input files shown to be fully compatible with both ASTRA and GPT. Here, detailed application examples demonstrating a subset of FEgen’s capabilities are given by creating a customized emitter pattern with application to transverse beam shaping and longitudinal beam dynamic experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dynamic Interference Management for UAV-Assisted Wireless Networks

Here, we investigate a transmission mechanism aiming to improve the data rate between a base station (BS) and a user equipment (UE) through deploying multiple relaying UAVs. We consider the effect of interference incurred by another established communication network, which makes our problem challenging and different from the state of the art. We aim to design the 3D trajectories and power allocation for the UAVs to maximize the data flow of the network while keeping the interference on the existing communication network below a threshold. We utilize the mobility feature of the UAVs to evade the (un)-intended interference caused by (un)-intentional interferers. To this end, we propose an alternating-maximization approach to jointly obtain the 3D trajectories and the UAVs transmission powers. We handle the 3D trajectory design by resorting to spectral graph the power allocation through convex optimization techniques. We also approach the problem from the intentional interferer’s perspective where smart jammers chase the UAVs to effectively degrade the data flow of the network. We also extend our work to the case for multiple UEs. Finally, we demonstrate the efficacy of our proposed method through extensive simulations.

42 ENGINEERING↗

Nb 3 Sn coating of SRF cavity by cosputtering from a composite target

Here, we deposited an Nb 3 Sn film on the inner surface of a 2.6 GHz Nb superconducting radio frequency cavity by cosputtering using a composite of Nb and Sn tube targets in a DC cylindrical magnetron sputtering system, followed by the thermal annealing of the coated cavity. An aluminum mockup cavity, replicating a 2.6 GHz Nb SRF cavity geometry, was utilized to optimize deposition parameters, resulting in cosputtered Nb–Sn films with an Sn content of 32–42 at. % on the beam tubes and equator positions. Several annealing conditions were investigated to improve the surface homogeneity of the Nb 3 Sn film. The best cosputtered Nb–Sn film was achieved after annealing at 600 °C for 6 h, followed by annealing at 950 °C for 1 h. The best process was applied to a Nb cavity, which was RF tested in a cryogenic dewar. RF testing of the Nb 3 Sn-coated cavity demonstrated a superconducting transition temperature of 17.78 K. The Nb 3 Sn cavity underwent light Sn recoating, followed by additional RF testing, resulting in the enhancement of the RF performance, primarily due to the improved surface homogeneity of the Nb 3 Sn coating.

Nb3Sn film↗