Search NASA⌕ Search

SEARCH · Search NASA

Results for “RF acceleration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

FEbeam: Cavity and electron emission data conversion, processing, and analysis. A freeware toolkit for rf injectors

FEbeam is an all-in-one field emission data processing interface with the capability to analyze the field emission cathode performance in an rf injector by extracting the field enhancement factor, local field, and effective emission area from the Fowler–Nordheim equations. It also has the capability of processing beam imaging micrographs using its sister software, FEpic. Furthermore, the current version of FEbeam was designed for the Argonne Cathode Test-stand of the Argonne Wakefield Accelerator facility switch yard. With slight modifications, FEbeam could work for many rf field emission injectors. This software is open-source and can be found at GitHub.

43 PARTICLE ACCELERATORS↗

Measurement of internal dark current in a 17 GHz accelerator structure with an elliptical sidewall

A 17 GHz single cell, standing wave, copper accelerator structure with an axisymmetric elliptical central cell sidewall was tested for internal and downstream dark current as a function of gradient up to 93 MV/m. The elliptical sidewall was predicted to suppress the internal dark current and the lower order multipactor modes as compared with a previously tested structure having a straight sidewall. During the conditioning phase of the elliptical sidewall structure, strong internal dark current generated by an N = 1 multipactor mode was observed at gradients in the 10 to 20 MV/m range. After conditioning with 2.2x10^5 pulses to 93 MV/m, the N = 1 mode was completely suppressed and no multipactor resonances were observed. The internal dark current was reduced to a comparatively low level, much smaller than in the previously studied, straight sidewall structure, in good agreement with simulations. The energy spectrum of the electrons colliding with the sidewall was measured using an isolated side dark current monitor and a bias voltage. As the conditioning progressed, the electron energy spectrum showed an increase in the concentration of lower energy electrons, also in good agreement with simulations. Studies of internal dark current may help to understand the rf conditioning and ultimate performance of high gradient accelerator structures.

43 PARTICLE ACCELERATORS↗

PIP-II LLRF Master Oscillator and Precision Reference Line - Station Level Design and Testing

The PIP-II superconducting linac at Fermilab requires a highly stable RF Reference Line to maintain phase syn- chronization throughout the accelerator. Temperature- induced changes in the electrical length of long coaxial cables can introduce phase drift and measurement errors. The reference-line architecture mitigates these effects by phase averaging the forward and reflected RF signals, while a phase-locked loop anchors the system to the mas- ter oscillator. This work focuses on the characterization, validation, and mechanical integration of station-level RF assemblies using CAD modeling, vector network analyzer measurements, and spectrum analyzer testing. PID-controlled thermal plates will stabilize critical RF components and further reduce temperature-dependent phase and amplitude variations. These methods sup- port repeatable, standardized designs that can be reliably integrated across the different reference-line stations.

Mosher, Alexander [U. Illinois, Chicago]↗

ACCELERATOR CHALLENGES OF THE LHeC PROJECT

The LHeC project studies the design of a future electron-proton collider at CERN that will run in parallel to the standard LHC operation. For this purpose, the existing LHC storage ring will be combined with an Energy Recovery Linac (ERL), to accelerate electrons up to kinetic energy of 50 GeV. This concept - also applicable to the FCC-eh collider and studied at the PERLE project as prototype version - allows a peak luminosity of 10³⁴ cm⁻² s⁻¹. A sophisticated design of the RF structures, linacs, arcs, and interaction region is required. The electrons are accelerated and, after the interaction point, their energy is recovered through the same RF structures. While this energy recovery concept is a very promising approach, severe challenges are set by the layout of the interaction region, the beam separation concept and the design of the linac and arc lattice for the highest possible momentum acceptance. Emittance control and beam-beam effect of both, electron and proton beams, have been studied in front-to-end simulations and will be presented. We summarise the design principles of the ERL, the optimization of the arc lattice, and the main parameters of the project.

Holzer, B. J.↗

Machine learning enhanced predictions of ICRF heating: Overcoming numerical limitations via data curation

In this work, we present the development of robust surrogate models for Ion Cyclotron Range of Frequencies (ICRF) and High-Harmonic Fast Wave (HHFW) heating predictions in fusion plasmas. Building upon our previous efforts to achieve real-time capable models, we identify the cause of the outliers found using TORIC in certain HHFW heating scenarios. The outliers are observed to be spurious ion Bernstein wave (IBW)-like modes caused by a wavelength control algorithm designed to address challenging scenarios with high perpendicular wavenumbers. The effect arises from the modulation in the perpendicular susceptibility, which can induce sign reversal and IBW-like propagation for scenarios featuring normalized ion Larmor radius λ i ≫ 1. We use TORIC with this algorithm disabled to generate a novel HHFW-NSTX database that is free of outliers. Surrogate models trained on this database, including Random Forest Regressor (RFR), Multi-Layer Perceptrons, and Gaussian Process Regressors (GPR), demonstrate the ability to accurately predict HHFW heating profiles, with regression scores of R 2 ∈[0.93−0.99]. Additionally we demonstrate that it is possible to generalize predictions beyond training data by the use of both RFR and GPR models, enabling the prediction of scenarios previously limited to the original model. GPR models also provide uncertainty quantification, offering insights into model confidence. This work introduces a comprehensive Verification, Validation, and Uncertainty Quantification methodology for surrogate modeling, applicable not only to ICRF heating but also to other RF heating challenges and fusion physics problems. Beyond accelerated inference, these models show effective extrapolation capabilities, providing an alternative for addressing numerical challenges.

Artificial neural networks↗

Data-driven gradient optimization for field emission management in a superconducting radio-frequency linac

Field emission can cause significant problems in superconducting radio-frequency linear accelerators (linacs). When cavity gradients are pushed higher, radiation levels within the linacs may rise exponentially, causing degradation of many nearby systems. This research aims to utilize machine learning with uncertainty quantification to predict radiation levels at multiple locations throughout the linacs and ultimately optimize cavity gradients to reduce field emission-induced radiation while maintaining the total linac energy gain necessary for the experimental physics program. The optimized solutions show over 40% reductions for both neutron and gamma radiation from the standard operational settings. Published by the American Physical Society 2025

43 PARTICLE ACCELERATORS↗

Stagger Tuning Summary [Slides]

Beam Breakup (BBU) is dangerous for high-current linear induction accelerators (LIA) used for flash radiography. Cavity mode RF is coupled to the beam. For frequencies lower than the beam-pipe cutoff, the cavities only communicate via RF on the beam. This cumulative mode BBU grows exponentially with a number of e-foldings proportional to (Number of cavities) X (Beam current) X (Coupling factor) / (Magnetic focusing field).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SRF Cavity Fault Classification and Prediction at Jefferson Lab

Over the last few years several machine learning projects at Jefferson Lab have had a common focus to optimize operation of superconducting RF (SRF) cavities in the Continuous Electron Beam Accelerator Facility (CEBAF). In this talk we highlight work to identify and classify types of faults from C100-type cavities and then to extend those capabilities to provide real-time fault prediction. Early prediction may enable mitigation strategies to prevent some types of faults. In our approach we apply a two-step fault prediction pipeline. In the first step, a model distinguishes between faulty and normal signals. In the second step, signals flagged as faulty by the first model are classified into one of seven fault types based on learned signatures in the data. Initial results show that our model can successfully predict most fault types 200 ms before onset. In additional to model performance, we also highlight challenges in working with real-world data and challenges for deploying models.

Tennant, C.↗

Microscopic Understanding of the Effects of Impurities in Low RRR SRF Cavities

The SRF community has shown that introducing certain impurities into high-purity niobium can improve quality factors and accelerating gradients. We question why some impurities improve RF performance while others hinder it. The purpose of this study is to characterize the impurities of niobium coupons with a low residual resistance ratio (RRR) and correlate these impurities with the RF performance of low RRR cavities so that the mechanism of impurity-based improvements can be better understood and improved upon. The combination of RF testing, temperature mapping, frequency vs temperature analysis, and materials studies reveals a microscopic picture of why low RRR cavities experience low BCS resistance behavior more prominently than their high RRR counterparts. We evaluate how differences in the mean free path, grain structure, and impurity profile affect RF performance. The results of this study have the potential to unlock a new understanding on SRF materials and enable the next generation of high Q/high gradient surface treatments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of a Traveling-Wave (TW) SRF cavity

Traveling-wave technology can push the accelerator field gradient of niobium SRF cavity to 70MV/m or higher beyond the fundamental limit of 50~60MV/m in Standing-Wave regime. The 1st demonstration of TW resonance excitation in a proof-of-principle 3-cell SRF cavity in 2K liquid helium was successfully carried out at Fermilab in collaboration with Euclid Techlabs. In parallel with that, to advancing TW technologies necessary more for future accelerator-scale one, Fermilab has proposed a preliminary RF design of a half-meter scale TW SRF cavity by considering the physical dimensions of existing SRF facilities and the lessons learned from the 3-cell,. It consists of a 7-cell structure and a power feedback waveguide (WG) loop with new RF configurations to control TW resonance. Development efforts toward a TW 7-cell has been in progress. Here we report the recent activities and progresses of those.

Furuta, F.↗

Mock-Up Waveguide Loop Development toward a Half-Meter Scale Traveling-Wave SRF Cavity

Mock-up waveguide loop development toward a half-meter scale traveling-wave SRF cavity ABSTRACT = Traveling-Wave (TW) technology can push the accelerator field gradient of niobium SRF cavity to 70MV/m or higher beyond the fundamental limit of 50~60MV/m in Standing-Wave regime. The success of TW resonance excitation in a proof-of-principle 3-cell SRF cavity in 2K liquid helium encouraged to advance TW technologies necessary more for future accelerator-scale one. Fermilab has proposed a preliminary RF design of a half-meter scale TW cavity by considering the physical dimensions of existing SRF facilities and the lessons learned from the 3-cell. It consists of a 7-cell structure and a power feedback waveguide (WG) loop with new TW excitation and control schemes such as, double directional coupler and two WG tuners. Mock-up waveguide loop development was launched under Fermilab LDRD program to demonstrate those new RF schemes at a room temperature. Fabrication drawings of a mock-up loop were completed. More details and plans of the development will be presented.

Furuta, Fumio [Fermilab]↗

The Collaborative Effects of Intrinsic and Extrinsic Impurities in Low RRR SRF Cavities

The SRF community has shown that introducing certain impurities into high-purity niobium can improve quality factors and accelerating gradients. We question why some impurities improve RF performance while others hinder it. The purpose of this study is to characterize the impurity profile of niobium coupons with a low residual resistance ratio (RRR) and correlate these impurities with the RF performance of low RRR cavities so that the mechanism of impurity-based improvements can be better understood and improved upon. The combination of RF testing and material analysis reveals a microscopic picture of why low RRR cavities experience low BCS resistance behavior more prominently than their high RRR counterparts. We performed surface treatments, low temperature baking and nitrogen-doping, on low RRR cavities to evaluate how the intentional addition of oxygen and nitrogen to the RF layer further improves performance through changes in the mean free path and impurity profile. Th e results of this study have the potential to unlock a new understanding on SRF materials and enable the next generation of high Q/high gradient surface treatments.

Howard, K.↗

The Collaborative Effects of Intrinsic and Extrinsic Impurities in Low RRR SRF Cavities

The SRF community has shown that introducing certain impurities into high-purity niobium can improve quality factors and accelerating gradients. We question why some impurities improve RF performance while others hinder it. The purpose of this study is to characterize the impurity profile of niobium coupons with a low residual resistance ratio (RRR) and correlate these impurities with the RF performance of low RRR cavities so that the mechanism of impurity-based improvements can be better understood and improved upon. The combination of RF testing and material analysis reveals a microscopic picture of why low RRR cavities experience low BCS resistance behavior more prominently than their high RRR counterparts. We performed surface treatments, low temperature baking and nitrogen-doping, on low RRR cavities to evaluate how the intentional addition of oxygen and nitrogen to the RF layer further improves performance through changes in the mean free path and impurity profile. The results of this study have the potential to unlock a new understanding on SRF materials and enable the next generation of high Q/high gradient surface treatments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Microscopic Understanding of the Effects of Impurities in Low RRR SRF Cavities

The SRF community has shown that introducing certain impurities into high-purity niobium can improve quality factors and accelerating gradients. We question why some impurities improve RF performance while others hinder it. The purpose of this study is to characterize the impurities of niobium coupons with a low residual resistance ratio (RRR) and correlate these impurities with the RF performance of low RRR cavities so that the mechanism of impurity-based improvements can be better understood and improved upon. The combination of RF testing, temperature mapping, frequency vs temperature analysis, and materials studies reveals a microscopic picture of why low RRR cavities experience low BCS resistance behavior more prominently than their high RRR counterparts. We evaluate how differences in the mean free path, grain structure, and impurity profile affect RF performance. The results of this study have the potential to unlock a new understanding on SRF materials and enable the next generation of high Q/high gradient surface treatments.

Howard, K.↗

Microscopic understanding of the effects of impurities in low RRR SRF cavities

The SRF community has shown that introducing certain impurities into high-purity niobium can improve quality factors and accelerating gradients. We question why some impurities improve RF performance while others hinder it. The purpose of this study is to characterize the impurities of niobium coupons with a low residual resistance ratio (RRR) and correlate these impurities with the RF performance of low RRR cavities so that the mechanism of impurity-based improvements can be better understood and improved upon. The combination of RF testing, temperature mapping, frequency vs temperature analysis, and materials studies reveals a microscopic picture of why low RRR cavities experience low BCS resistance behavior more prominently than their high RRR counterparts. We evaluate how differences in the mean free path, grain structure, and impurity profile affect RF performance. The results of this study have the potential to unlock a new understanding on SRF materials and enable the next generation of high Q/high gradient surface treatments.

Howard, K.↗

Mock-up Waveguide Loop Development toward a half-meter scale Traveling-Wave (TW) SRF cavity

Traveling-Wave (TW) technology can push the accelera-tor field gradient of niobium SRF cavity to 70MV/m or higher beyond the fundamental limit of 50~60MV/m in Standing-Wave regime. The success of TW resonance excitation in a proof-of-principle 3-cell SRF cavity in 2K liquid helium encouraged to advance TW technologies necessary more for future accelerator-scale one. Fermilab has proposed a preliminary RF design of a half-meter scale TW cavity by considering the physical dimensions of existing SRF facilities and the lessons learned from the 3-cell. It consists of a 7-cell structure and a power feed-back waveguide (WG) loop with new TW excitation and control schemes such as, double directional coupler and two WG tuners. Mock-up waveguide loop development was launched under Fermilab LDRD program to demon-strate those new RF schemes at a room temperature. Fab-rication drawings of a mock-up loop were completed. Here details and plans of the development are reported.

Furuta, F. [Fermilab] (ORCID:0009000072218576)↗