Search NASA⌕ Search

SEARCH · Search NASA

Results for “RF source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

A novel photonic oscillator

We report a novel oscillator for photonic RF systems. This oscillator is capable of generating high-frequency signals up to 70 GHz in both electrical and optical domains and is a special voltage-controlled oscillator with an optical output port. It can be used to make a phase-locked loop (PLL) and perform all functions that a PLL is capable of for photonic systems. It can be synchronized to a reference source by means of optical injection locking, electrical injection locking, and PLL. It can also be self-phase locked and self-injection locked to generate a high-stability photonic RF reference. Its applications include high-frequency reference regeneration and distribution, high-gain frequency multiplication, comb-frequecy and square-wave generation, carrier recovery, and clock recovery. We anticipate that such photonic voltage-controlled oscillators (VCOs) will be as important to photonic RF systems as electrical VCOs are to electrical RF systems.

Yao, X. S.↗

Semiconductor Laser Low Frequency Noise Characterization

This work summarizes the efforts in identifying the fundamental noise limit in semiconductor optical sources (lasers) to determine the source of 1/F noise and it's associated behavior. In addition, the study also addresses the effects of this 1/F noise on RF phased arrays. The study showed that the 1/F noise in semiconductor lasers has an ultimate physical limit based upon similar factors to fundamental noise generated in other semiconductor and solid state devices. The study also showed that both additive and multiplicative noise can be a significant detriment to the performance of RF phased arrays especially in regard to very low sidelobe performance and ultimate beam steering accuracy. The final result is that a noise power related term must be included in a complete analysis of the noise spectrum of any semiconductor device including semiconductor lasers.

SEMICONDUCTOR LASERS↗

A rack-mounted precision waveguide-below-cutoff attenuator with an absolute electronic readout

A coaxial precision waveguide-below-cutoff attenuator is described which uses an absolute (unambiguous) electronic digital readout of displacement in inches in addition to the usual gear driven mechanical counter-dial readout in decibels. The attenuator is rack-mountable and has the input and output RF connectors in a fixed position. The attenuation rate for 55, 50, and 30 MHz operation is given along with a discussion of sources of errors. In addition, information is included to aid the user in making adjustments on the attenuator should it be damaged or disassembled for any reason.

Cook, C. C.↗

X-33 Integrated Test facility, Extended Range Simulation

In support of the X-33 Single Stage To Orbit program, NASA Dryden Flight Research Center was selected to provide continuous communications coverage of the X-33 vehicle from launch, through landing at Malmstrom Air Force Base, Montana and Michaels Army Air Field, Utah. An extensive real-time range simulation capability is being developed to ensure successful communications with the autonomous X-33 vehicle. This paper will provide an overview of the various levels of simulation being developed to support the X-33 extended range subsystems. These subsystems include the Flight Termination System, L-Band command uplink subsystem and the S-Band telemetry downlink subsystem. In addition, the radar model developed provides continuous azimuth, elevation and range information based on the flight trajectory. The Dynamic Ground Station Analysis model developed by NASA Goddard Space Flight Center, calculate the received signal strength at each ground station. This model takes into consideration Radio Frequency (RF) link parameters such as frequency, antenna gain, space loss, plasma effects and the vehicle's position and attitude at any point in time during the flight path. All three RF links are then attenuated based on this calculated level and the RF signals are sent into telemetry receivers to emulate remote sites, or the power incident on the vehicle from uplinked signals. The best source received telemetry data is then passed back to the Launch and Mission Control Monitoring System (LMCMS) resident in the Operations Control Center. The LMCMS also provides the range simulation system the uplink command combined with differential GPS corrections. Later stages will require the progressive integration of actual range hardware with this simulation effort, leading to communication between telemetry, uplink and FTS antennas at NASA Dryden Flight Research Center, with vehicle antennas mounted on the Walter C. Williams Research Aircraft Integration Facility (RAIF). Decommutated Pulse Code Modulated (PCM) data is displayed on one of the four monitors that comprise the Range Safety Officer's (RSO) station. Also displayed are instantaneous impact prediction models, and Federal Aviation Administration (FAA) data for notification of other traffic in the area. Aside from initiating the flight termination command and validating communication links, the RSO station with the range simulation will be used to provide both range control and range safety officers training. The training is necessary to perform their respective functions with greater levels of confidence prior to first flight.

Sharma, Ashley↗

Stability and Phase Noise Tests of Two Cryo-Cooled Sapphire Oscillators

A cryocooled Compensated Sapphire Oscillator (CSO), developed for the Cassini Ka-band Radio Science experiment, and operating in the 8K - 10K temperature range was previously demonstrated to show ultra-high stability of sigma(sub y) = 2.5 x 10 (exp -15) for measuring times 200 seconds less than or equal to tau less than or equal to 600 seconds using a hydrogen maser as reference. We present here test results for a second unit which allows CSO short-term stability and phase noise to be measured for the first time. Also included are design details of a new RF receiver and an intercomparison with the first CSO unit. Cryogenic oscillators operating below about 10K offer the highest possible short term stability of any frequency sources. However, their use has so far been restricted to research environments due to the limited operating periods associated with liquid helium consumption. The cryocooled CSO is being built in support of the Cassini Ka-band Radio Science experiment and is designed to operate continuously for periods of a year or more. Performance targets are a stability of 3-4 x 10 (exp -15) (1 second less than or equal to tau less than or equal to 100 seconds) and phase noise of -73dB/Hz @ 1Hz measured at 34 GHz. Installation in 5 stations of NASA's deep space network (DSN) is planned in the years 2000 - 2002. In the previous tests, actual stability of the CSO for measuring times tau less than or equal to 200 seconds could not be directly measured, being masked by short-term fluctuations of the H-maser reference. Excellent short-term performance, however, could be inferred by the success of an application of the CSO as local oscillator (L.O.) to the JPL LITS passive atomic standard, where medium-term stability showed no degradation due to L.O. instabilities at a level of (sigma)y = 3 x 10 (exp -14)/square root of tau. A second CSO has now been constructed, and all cryogenic aspects have been verified, including a resonator turn-over temperature of 7.907 K, and Q of 7.4 x 10 (exp 8). These values compare to a turn-over of 8.821 K and Q of 1.0 x 10 (exp 9) for the first resonator. Operation of this second unit provides a capability to directly verify for the first time the short-term (1 second less than or equal to tau less than or equal to 200 seconds) stability and the phase noise of the CSO units. The RF receiver used in earlier tests was sufficient to meet Cassini requirements for tau greater than or equal to 10 seconds but had short-term stability limited to 2-4 x 10 (exp -14) at tau = 1 second, a value 10 times too high to meet our requirements. A new low-noise receiver has been designed to provide approximately equal to 10-15 performance at 1 second, and one receiver is now operational, demonstrating again short-term CSO performance with H maser-limited stability. Short-term performance was degraded in the old receiver due to insufficient tuning bandwidth in a 100MHZ quartz VCO that was frequency-locked to the cryogenic sapphire resonator. The new receivers are designed for sufficient bandwidth, loop gain and low noise to achieve the required performance.

Dick, G. John↗

Ion Manipulation from Liquid Xe to Vacuum: Ba-Tagging for a nEXO Upgrade and Future 0 νββ Experiments

Neutrinoless double beta decay (0𝜈𝛽𝛽) provides a way to probe physics beyond the Standard Model of particle physics. The upcoming nEXO experiment will search for 0𝜈𝛽𝛽 decay in 136 Xe with a projected half-life sensitivity exceeding 10 28 years at the 90% confidence level using a liquid xenon (LXe) Time Projection Chamber (TPC) filled with 5 tonnes of Xe enriched to ∼90% in the 𝛽𝛽-decaying isotope 136 Xe. In parallel, a potential future upgrade to nEXO is being investigated with the aim to further suppress radioactive backgrounds and to confirm 𝛽𝛽-decay events. This technique, known as Ba-tagging, comprises extracting and identifying the 𝛽𝛽-decay daughter 136 Ba ion. One tagging approach being pursued involves extracting a small volume of LXe in the vicinity of a potential 𝛽𝛽-decay using a capillary tube and facilitating a liquid-to-gas phase transition by heating the capillary exit. The Ba ion is then separated from the accompanying Xe gas using a radio-frequency (RF) carpet and RF funnel, conclusively identifying the ion as 136 Ba via laser-fluorescence spectroscopy and mass spectrometry. Simultaneously, an accelerator-driven Ba ion source is being developed to validate and optimize this technique. The motivation for the project, the development of the different aspects, along with the current status and results, are discussed here.

a-tagging↗

Preliminary Assessment of Detection Efficiency for the Geostationary Lightning Mapper Using Intercomparisons with Ground-Based Systems

As part of the calibration/validation (cal/val) effort for the Geostationary Lightning Mapper (GLM) on GOES-16, we need to assess instrument performance (detection efficiency and accuracy). One major effort is to calculate the detection efficiency of GLM by comparing to multiple ground-based systems. These comparisons will be done pair-wise between GLM and each other source. A complication in this process is that the ground-based systems sense different properties of the lightning signal than does GLM (e.g., RF vs. optical). Also, each system has a different time and space resolution and accuracy. Preliminary results indicate that GLM is performing at or above its specification.

GL↗

Improvements to the Simulated CubeSpark Satellite Constellation and Their Effects on Lightning Geolocation Accuracy from Orbit

The CubeSpark mission concept is being developed as a constellation of up to six satellites in low-Earth orbit (LEO) for high resolution 3D lightning mapping using optical and radio frequency (RF) sensors. Individual lightning VHF signals are simulated from Earth’s atmosphere through the ionosphere to each satellite, using their arrival times to reconstruct source locations. Here we present recent updates to these simulations based on improved ionospheric modeling, with a focus on the expected three-dimensional resolution. These studies include testing from the equator up to high latitudes, with varying vertical total electron content (vTEC), and using between one and six orbiting stations. In addition to the more robust ionosphere model, the constellation formation has also been updated to reduce its resulting errors and increase the effective range of VHF geolocation from space. The goals of CubeSpark include mapping thundercloud charge structure as well as lightning channel lengths relevant to climatology, meteorology, and more. These applications require location uncertainty less than 1-2 km in each dimension. This improved algorithm shows sufficient resolution up to high latitudes, including significantly larger areas having 3D resolution less than 1 km. Analysis of the distributions of biases in simulated arrival times has also revealed the unexpected relationship between the shape of those distributions and the resulting uncertainties. This work helps to refine our understanding of the sources of error in lightning geolocation and reinforces the potential for post-processing improvements in this and other similar systems.

Lightning↗

Atomic oxygen beam source for erosion simulation

A device for the production of low energy (3 to 10 eV) neutral atomic beams for surface modification studies is described that reproduces the flux of atomic oxygen in low Earth orbit. The beam is produced by the acceleration of plasma ions onto a negatively biased plate of high-Z metal; the ions are neutralized and reflected by the surface, retaining some fraction of their incident kinetic energy, forming a beam of atoms. The plasma is generated by a coaxial RF exciter which produces a magnetically-confined (4 kG) plasma column. At the end of the column, ions fall through the sheath to the plate, whose bias relative to the plasma can be varied to adjust the beam energy. The source provides a neutral flux approximately equal to 5 x 10(exp 16)/sq cm at a distance of 9 cm and a fluence approximately equal to 10(exp 20)/sq cm in five hours. The composition and energy of inert gas beams was diagnosed using a mass spectometer/energy analyzer. The energy spectra of the beams demonstrate energies in the range 5 to 15 eV, and qualitatively show expected dependences upon incident and reflecting atom species and potential drop. Samples of carbon film, carbon-based paint, Kapton, mylar, and teflon exposed to atomic O beams show erosion quite similar to that observed in orbit on the space shuttle.

Cuthbertson, J. W.↗

Ion Storage Tests with the High Performance Antimatter Trap (HiPAT)

The NASA/Marshall Space Flight Centers (NASA/MSFC) Propulsion Research Center (PRC) is evaluating an antiproton storage system, referred to as the High Performance Antiproton Trap (HiPAT). This interest stems from the sheer energy represented by matter/antimatter annihilation process with has an energy density approximately 10 order of magnitude above that of chemical propellants. In other terms, one gram of antiprotons contains the equivalent energy of approximately 23 space shuttle external tanks or ET's (each ET contains roughly 740,000 kgs of fuel and oxidizer). This incredible source of stored energy, if harnessed, would be an enabling technology for deep space mission where both spacecraft weight and propulsion performance are key to satisfying aggressive mission requirements. The HiPAT hardware consists of a 4 Tesla superconductor system, an ultra high vacuum test section (vacuum approaching 10(exp -12) torr), and a high voltage confinement electrode system (up to 20 kvolts operation). The current laboratory layout is illustrated. The HiPAT designed objectives included storage of up to 1 trillion antiprotons with corresponding lifetimes approaching 18 days. To date, testing has centered on the storage of positive hydrogen ions produced in situ by a stream of high-energy electrons that passes through the trapping region. However, due to space charge issues and electron beam compression as it passes through the HiPAT central field, current ion production is limited to less then 50,000 ions. Ion lifetime was determined by counting particle populations at the end of various storage time intervals. Particle detection was accomplished by destructively expelling the ions against a micro-channel plate located just outside the traps magnetic field. The effect of radio frequency (RF) stabilization on the lifetime of trapped particles was also examined. This technique, referred to as a rotating wall, made use of a segmented electrode located near the center of the trap on which various phases of a particular frequency were applied. Various experiments were performed illustrating the ability of an RF drive to both prolong and reduced the lifetimes of various ion species depending on the selected frequency. HiPAT is now being reconfigured for testing with an ion source that will provide both positive and negative hydrogen ions from an external source. This ion system shall provide higher fill capacity (order of million of ions per shot), stacking of multiple shots, and injection schemes typical of a realistic antiproton delivery system.

Martin, James J.↗

Magnetic Compensation for Second-Order Doppler Shift in LITS

The uncertainty in the frequency of a linear-ion-trap frequency standard (LITS) can be reduced substantially by use of a very small magnetic inhomogeneity tailored to compensate for the residual second-order Doppler shift. An effect associated with the relativistic time dilatation, one cause of the second-order Doppler shift, is ion motion that is attributable to the trapping radio-frequency (RF)electromagnetic field used to trap ions. The second-order Doppler shift is reduced by using a multi-pole trap; however it is still the largest source of systematic frequency shift in the latest generation of LITSs, which are among the most stable clocks in the world. The present compensation scheme reduces the frequency instability of the affected LITS to about a tenth of its previous value. The basic principles of prior generation LITSs were discussed in several prior NASA Tech Briefs articles. Below are recapitulated only those items of basic information necessary to place the present development in context. A LITS includes a microwave local oscillator, the frequency of which is stabilized by comparison with the frequency of the ground state hyperfine transition of 199Hg+ ions. The comparison involves a combination of optical and microwave excitation and interrogation of the ions in a linear ion trap in the presence of a nominally uniform magnetic field. In the current version of the LITS, there are two connected traps (see figure): (1) a quadrupole trap wherein the optical excitation and measurement take place and (2) a 12-pole trap (denoted the resonance trap), wherein the microwave interrogation takes place. The ions are initially loaded into the quadrupole trap and are thereafter shuttled between the two traps. Shuttling ions into the resonance trap allows sensitive microwave interrogation to take place well away from loading interference. The axial magnetic field for the resonance trap is generated by an electric current in a finely wound wire coil surrounded by magnetic shields. In the quadrupole and 12-pole traps, the potentials are produced by RF voltages applied to even numbers (4 and 12, respectively) of parallel rods equally spaced around a circle. The polarity of the voltage on each rod is opposite that of the voltage on the adjacent rod. As a result, the amplitude of the RF trapping field is zero along the centerline and increases, with radius, to a maximum value near the rods.

Burt, Eric↗

Tunable Microwave Cavity For Ion Source

Movable probe and tuning wall adjusted to obtain resonance at microwave frequency used to generate plasma in cell at one end of microwave cavity. Electroless discharge without disadvantages of dc-cathode-discharge and RF-induction methods. To achieve precise positioning, coaxial probe extends into microwave cavity through tube.

Nakanishi, Shigeo↗

Thermal evaluation method for Klystron RF power

The feasibility of adding instrumentation to the cooling system of a microwave transmitter for use as a calorimetric power measurement calibration is examined. It considers the accuracy of the basic measurements as well as heat sources and losses not measured. Experimental results are presented in support of the theory.

Conroy, B. L.↗

Formation of niobium hydride precipitates in superconducting qubits

We report evidence for the formation of niobium hydride phase within niobium films on silicon substrates in superconducting qubits fabricated at Rigetti Computing. For this study, we combined complementary techniques—including room-temperature and cryogenic atomic force microscopy (AFM), synchrotron x-ray diffraction, and time-of-flight secondary ion mass spectroscopy (ToF-SIMS)—to directly reveal the existence of niobium hydride precipitates on the surface of superconducting qubits. Upon cryogenic cooling, we observed variation in the size and morphology of the hydrides, ranging from small (∼5 nm) irregular shapes to large (∼10–100 nm) domains within the Nb grains, which were fully converted to niobium hydrides. Since niobium hydrides are nonsuperconducting and can easily change in size and location upon different cooldowns to cryogenic temperature, our finding highlights a previously unknown source of decoherence in superconducting qubits. This contributes to quasiparticle losses, offering a potential explanation for changes in qubit performance upon cooldowns. Finally, by leveraging the RF performance of a 3D bulk Nb resonator, we quantify RF dissipation in a superconducting qubit caused by hydrogen concentration variation, and propose a practical engineering pathway to mitigate the formation of Nb hydrides for superconducting qubit applications.

Sung, Zuhawn [Fermi National Accelerator Laborator↗

The TWERLE balloon-to-satellite data transmitting system

This paper describes the balloon instrumentation system which provides the one-way link for data gathering and navigation in the Tropical Wind, Energy conversion and Reference Level Experiment (TWERLE). In this experiment, 400 instrumented constant-level balloons will be launched at the southern hemisphere during 1975. The Random Access Measurement System (RAMS) on board the Nimbus-F satellite, will comprise the receiving end of the link. The data encoder, stable oscillator, transmitter and antenna are described, as well as two supporting components, the power source and the magnetic cutdown. These six items weigh 850 g. The oscillator-transmitter consume 1.9 W dc power to provide 0.6 W phase modulated RF power.

Levanon, N.↗

Phase Drifts and Signal Dispersion in Coaxial Cables

Phase reference distribution is a critical challenge in modern linear particle accelerators, such as European Spallation Source (ESS), European X-ray Free Electron Laser (E-XFEL), or Proton Improvement Plan II (PIP-II). Similar issues may also arise in other RF systems that need to synchronize many independent circuits. Achieving low phase drift of the reference signal requires careful selection of cables and their environmental operating conditions. Due to the limited data provided by cable manufacturers, it is necessary to characterize the cable performance. This article investigates the phase drifts in coaxial cables and presents a dedicated measurement methodology. The dispersion characteristics of the cables are also examined. The measurement results of various coaxial cables are presented, along with conclusions and practical guidelines for designers of phase reference distribution lines.

coaxial cables↗

Ferroelectric Emission Cathodes for Low-Power Electric Propulsion

Low- or no-flow electron emitters are required for low-power electric thrusters, spacecraft plasma contactors, and electrodynamic tether systems to reduce or eliminate the need for propellant/expellant. Expellant-less neutralizers can improve the viability of very low-power colloid thrusters, field emission electric propulsion devices, ion engines, Hall thrusters, and gridded vacuum arc thrusters. The NASA Glenn Research Center (GRC) is evaluating ferroelectric emission (FEE) cathodes as zero expellant flow rate cathode sources for the applications listed above. At GRC, low voltage (100s to approx. 1500 V) operation of FEE cathodes is examined. Initial experiments, with unipolar, bipolar, and RF burst applied voltage, have produced current pulses 250 to 1000 ns in duration with peak currents of up to 2 A at voltages at or below 1500 V. In particular, FEE cathodes driven by RF burst voltages from 1400 to 2000 V peak to peak, at burst frequencies from 70 to 400 kHz, emitted average current densities from 0.1 to 0.7 A/sq cm. Pulse repeatability as a function of input voltage has been initially established. Reliable emission has been achieved in air background at pressures as high as 10(exp -6) Torr.

Kovaleski, Scott D.↗

Ion-Atom Cold Collisions and Atomic Clocks

Collisions between ultracold neutral atoms have for some time been the subject of investigation, initially with hydrogen and more recently with laser cooled alkali atoms. Advances in laser cooling and trapping of neutral atoms in a Magneto-Optic Trap (MOT) have made cold atoms available as the starting point for many laser cooled atomic physics investigations. The most spectacularly successful of these, the observation of Bose-Einstein Condensation (BEC) in a dilute ultra-cold spin polarized atomic vapor, has accelerated the study of cold collisions. Experimental and theoretical studies of BEC and the long range interaction between cold alkali atoms is at the boundary of atomic and low temperature physics. Such studies have been difficult and would not have been possible without the development and advancement of laser cooling and trapping of neutral atoms. By contrast, ion-atom interactions at low temperature, also very difficult to study prior to modern day laser cooling, have remained largely unexplored. But now, many laboratories worldwide have almost routine access to cold neutral atoms. The combined technologies of ion trapping, together with laser cooling of neutrals has made these studies experimentally feasible and several very important, novel applications might come out of such investigations . This paper is an investigation of ion-atom interactions in the cold and ultra-cold temperature regime. Some of the collisional ion-atom interactions present at room temperature are very much reduced in the low temperature regime. Reaction rates for charge transfer between unlike atoms, A + B(+) approaches A(+) + B, are expected to fall rapidly with temperature, approximately as T(sup 5/2). Thus, cold mixtures of atoms and ions are expected to coexist for very long times, unlike room temperature mixtures of the same ion-atom combination. Thus, it seems feasible to cool ions via collisions with laser cooled atoms. Many of the conventional collisional interactions, exploited as a useful tool at room temperature and higher, are greatly enhanced at low energy. For example, collisional spin transfer from one species of polarized atoms to another has long been a useful method for polarizing a sample of atoms where no other means was available. Because optical pumping cannot be used to polarize the nuclear spin of Xe-129 or He-3 (for use in nmr imaging of the lungs), the nuclear spins are polarized via collisions with an optically pumped Rb vapor in a cell containing both gases. In another case, a spin polarized thermal Cs beam was used to polarize the hyperfine states of trapped He(+)-3 ions in order to measure their hyperfine clock transition frequency. The absence of an x-ray light source to optically pump the ground state of the He(+)-3 ion necessitated this alternative state preparation. Similarly, Cd(+) and Sr(+) ions were spin-oriented via collisions in a cell with optically pumped Rb vapor. Resonant RF spin changing transitions in the ground state of the ions were detected by changes in the Rb resonance light absorption. Because cold collision spin exchange rates scale with temperature as T(sup -1/2) this technique is expected to be a far more powerful tool than the room temperature counterpart. This factor of 100 or more enhancement in spin exchange reaction rates at low temperatures is the basis for a novel trapped ion clock where laser cooled neutrals will cool, state select and monitor the ion clock transition. The advantage over conventional direct laser cooling of trapped ions is that the very expensive and cumbersome UV laser light sources, required to excite the ionic cooling transition, are effectively replaced by simple diode lasers.

Prestage, John D.↗