Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiation Tolerance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Assessment of coated cladding impact on large-break LOCA with TRACE-DAKOTA

Since 2011, the U.S. Department of Energy has launched new research and development (R&D) programs for developing new accident tolerant fuels (ATFs). These new fuel concepts are expected to bring several advancements in terms of plant safety. However, development, licensing, as well as deployment of ATF require a substantial investment among fuel vendors, operating utilities, and regulatory authorities. For ATF to be economically feasible, credited safety benefits may be necessary to provide an economic incentive for transition of nuclear power plants from Zr/UO2-based fuel technologies to ATFs. As a result, it is essential to evaluate the economic viability of ATF by conducting a comprehensive safety benefits study informed by R&D and demonstration studies. In the present work, based on the best estimate plus uncertainty methodology, sensitivity analysis and uncertainty quantification for key safety quantities under LB-LOCA are performed for the Peach Bottom boiling water reactor (BWR) with GE14 nuclear fuel design adopting the ATF concepts. A coupled TRACE-DAKOTA analysis framework is adopted to perform the uncertainty quantification. Based on the computational results and obtained statistics, the coping time increase, fuel performance improvement as well as the most dominating phenomena during the accident for Cr-coated cladding are investigated in detail. Overall, the results obtained are useful for subsequent plant PRA study and support a move to more modernized performance-based regulatory requirements to realize plant economic benefits.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Pool boiling critical heat flux studies of accident tolerant fuel cladding materials

Pool boiling experiments have been performed at atmospheric pressure on potential accident tolerant fuel (ATF) cladding materials (Zirlo®, Cr coated Zirlo®, FeCrAl coated Zirlo®, and monolithic SiC) to evaluate the Critical Heat Flux (CHF) points. Corrosion resistant coatings of Cr and FeCrAl alloy were deposited on flat Zirlo® samples using cold spray technology. The as-prepared samples after uniform surface polishing were subjected to autoclave tests at 360 °C water and 18.6 MPa for 360 h to simulate prototypic corrosion of the ATF cladding materials in LWR normal operation. Surface characteristics potentially influencing CHF such as surface morphology, roughness, static contact angle, and surface chemistry were characterized using a suite of characterization methods including scanning electron microscopy, 3D optical profilometry, optical contact angle measurements, and x-ray photoelectron spectroscopy (XPS). Thermo-physical properties of the samples such as density, thermal conductivity, and heat capacity were measured by differential scanning calorimetry and laser flash thermal diffusivity measurement. FeCrAl coatings showed CHF values comparable to bare Zirlo® samples, while slightly lower CHF values were observed for Cr coated samples and bulk SiC flats (produced by chemical vapor deposition, CVD). As-deposited Cr coatings showed 67% higher CHF than the as-polished Cr coatings due to its higher surface roughness level. The autoclave testing for the prepared samples generally increased the CHF except for the surface polished Cr coatings. Similar CHF values of bare Zirlo®, FeCrAl coating, and CVD SiC samples were observed after autoclave test but there were negligible change CHF of Cr coatings. XPS studies indicated that the formation or deposition of a few monolayers of hydrophobic carbonaceous species on surface can affect CHF values. The trends in CHF data are discussed in terms of evolution of the surface characteristics of the ATF materials.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

System code evaluation of near-term accident tolerant claddings during pressurized water reactor station blackout accidents

Following the Fukushima Daiichi nuclear accident in 2011, researches on Accident-tolerant fuels (ATFs) are currently of high interest in not only the nuclear industry but also governmental and international organizations. In this work, a quantitative evaluation of the performance of monolithic FeCrAl cladding and Cr-coated Zircaloy cladding has been performed for Pressurized Water Reactor (PWR) Station Blackout (SBO) accidents. A generic PWR model has been built in system thermal-hydraulics code TRACE based on the Surry Nuclear Power Station with counter-current natural circulation modelling capability for hotleg and steam generator U-tube components during the accidents. The base model results are then compared to MELCOR and RELAP simulations to verify the system component implementation in TRACE. Two PWR SBO scenarios were investigated, including: short-term SBO and long-term SBO with early reactor coolant pump (RCP) seal failure. These scenarios are defined to be very similar to the accidents studied in the State-of-the-Art Reactor Consequence Analysis (SOARCA) project. TRACE code is modified to reflect the oxidation kinetics of FeCrAl and Cr-coating. Larson-Miller creep rupture model is also implemented in TARCE using its built-in control systems to simulate the creep rupture of hotlegs. Additionally, the comparison between the TRACE models with and without the counter-current flow modeling resulted in significant difference when comparing ATF cladding to Zircaloy for short term SBO, while it marginal impacted the performance during long term SBO with RCP seal failure. For short term SBO, both ATF cladding underwent hot leg creep rupture ~20 min after Zircaloy cladding. While Zircaloy and Cr-coated cladding had generated significant amount of hydrogen gas (>10 kg) before the creep rupture event, FeCrAl cladding had only generated <0.5 kg of hydrogen gas. For long term SBO with RCP seal failure, significant hydrogen generation and fuel melting was predicted before hot leg creep rupture for the ATF cladding while providing only 10–20 min additional coping time compared to Zircaloy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Electron pulse-dilation diagnostic instruments

During the past decade, a number of diagnostic instruments have been developed that utilize electron pulse-dilation to achieve temporal resolution in the 5–30 ps range. These development efforts were motivated by the need for advanced diagnostics for high-energy density physics experiments around the world. The new instruments include single- and multi-frame gated imagers and non-imaging detectors that record continuous data streams. Electron pulse-dilation provides high-speed detection capability by converting incoming signals into a free electron cloud and manipulating the electron signal with electric and magnetic fields. In this paper we discuss design details and applications of these instruments along with issues and challenges associated with employing the electron pulse-dilation technique. Additionally, methods to characterize instrument performance and improve tolerance to gamma and neutron background radiation are discussed.

47 OTHER INSTRUMENTATION↗

Combination of Olaparib and Radiation Therapy for Triple Negative Breast Cancer: Preliminary Results of the RADIOPARP Phase 1 Trial

Preclinical studies have evidenced that triple-negative breast cancer (TNBC) cell lines are more sensitive to poly (ADP-ribose) polymerase inhibitors. This provides a strong rationale for developing a new therapeutic approach for TNBC management based on poly (ADP-ribose) polymerase inhibition. The primary goal of the RADIOPARP phase 1 trial was to evaluate the dose-limiting toxicities (DLT) and the maximum tolerated dose of olaparib combined with locoregional radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of radiation exposure on survival after first solid cancer diagnosis in A-bomb survivors

Comparison of the estimated effect of atomic bomb radiation exposure on solid cancer incidence and solid cancer mortality in the RERF Life Span Study (LSS) reveals a difference in the magnitude and shape of the excess relative risk dose response. A possible contributing factor to this difference is pre-diagnosis radiation effect on post-diagnosis survival. Pre-diagnosis radiation exposure theoretically could influence post-diagnosis survival by affecting the genetic makeup and possibly aggressiveness of cancer, or by compromising tolerance for aggressive treatment for cancer. We analyze the radiation effect on post-diagnosis survival in 20,463 LSS subjects diagnosed with first-primary solid cancer between 1958 and 2009 with particular attention to whether death was caused by the first-primary cancer, other cancer, or non-cancer diseases. From multivariable Cox regression analysis of cause-specific survival, the excess hazard at 1 Gy (EH 1Gy ) for death from the first primary cancer was not significantly different from zero – p = 0.23, EH 1Gy = 0.038 (95 % CI: –0.023, 0.104). Death from other cancer and death from non-cancer diseases both were significantly associated with radiation dose: other cancer EH 1Gy = 0.38 (95 % CI: 0.24, 0.53); non-cancer EH 1Gy = 0.24 (95 % CI: 0.13, 0.36), both p < 0.001. There is no detectable large effect of pre-diagnosis radiation exposure on post-diagnosis death from the first primary cancer in A-bomb survivors. A direct effect of pre-diagnosis radiation exposure on cancer prognosis is ruled out as an explanation for the difference in incidence and mortality dose response in A-bomb survivors.

60 APPLIED LIFE SCIENCES↗

Radiation Stability of Mixed Tin-Lead Halide Perovskites: Implications for Space Applications

Mixed organic-inorganic halide perovskite solar cells (PSCs) have received considerable attention in recent years for their impressive solar to electrical power efficiency gains and potentially lower material and processing costs for optoelectronic applications. In addition to terrestrial applications, PSCs are of interest to the space power markets for their low cost, low weight, adaptability to flexible architectures, and tolerance to high energy particle irradiation (mainly protons and electrons). Here we investigate the properties of mixed formamidinium-methylammonium tin-lead iodide (FASn)0.6(MAPb)0.4I3 perovskites which lower the lead content as well as the bandgap, making them attractive for the low bandgap absorber material in tandem PSCs. Through current density-voltage (JV) characterization at lower temperatures, majority carrier transport is hindered and a barrier to photogenerated carrier extraction is evident. This is attributed to the thermally induced change of the bandgap of the absorber layer relative to the energy selective contacts in the device. We find that although the architecture used here hinders the performance at temperatures below 225 K, the tolerance to high energy (3.7 MeV) protons is impressive, considerably out-performing commercially available thin-film CIGS. These results suggest further improvements to structural and interface stability as well as lightweight encapsulation could lead to all perovskite flexible tandem arrays deployed for power generation on missions to low Earth orbit, the moon, Mars, and beyond.

perovskite solar cells↗

Establishment of Microbeam Radiation Therapy at a Small-Animal Irradiator

Microbeam radiation therapy is a preclinical concept in radiation oncology. It spares normal tissue more effectively than conventional radiation therapy at equal tumor control. The radiation field consists of peak regions with doses of several hundred gray, whereas doses between the peaks (valleys) are below the tissue tolerance level. Widths and distances of the beams are in the submillimeter range for microbeam radiation therapy. A similar alternative concept with beam widths and distances in the millimeter range is presented by minibeam radiation therapy. Although both methods were developed at large synchrotron facilities, compact alternative sources have been proposed recently.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

PI3Kαδ Inhibitor Combined With Radiation Enhances the Antitumor Immune Effect of Anti-PD1 in a Syngeneic Murine Triple-Negative Breast Cancer Model

The poor response of breast cancer to immune checkpoint blockade might result from low immunogenicity and the immune-suppressive tumor microenvironment. We hypothesized that in situ tumor vaccination via radiation therapy (RT) and suppression of immune tolerance via phosphoinositide 3-kinase δ (PI3Kδ) inhibition would enhance the efficacy of immune checkpoint blockade.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of ionizing radiation on superconducting qubit coherence

The practical viability of any qubit technology stands on long coherence times and high-fidelity operations, with the superconducting qubit modality being a leading example. However, superconducting qubit coherence is impacted by broken Cooper pairs, referred to as quasiparticles, with a density that is empirically observed to be orders of magnitude greater than the value predicted for thermal equilibrium by the Bardeen-Cooper-Schrieffer (BCS) theory of superconductivity. Previous work has shown that infrared photons significantly increase the quasiparticle density, yet even in the best isolated systems, it still remains higher than expected, suggesting that another generation mechanism exists. In this Letter, we provide evidence that ionizing radiation from environmental radioactive materials and cosmic rays contributes to this observed difference, leading to an elevated quasiparticle density that would ultimately limit superconducting qubits of the type measured here to coherence times in the millisecond regime. We further demonstrate that introducing radiation shielding reduces the flux of ionizing radiation and positively correlates with increased coherence time. Albeit a small effect for today’s qubits, reducing or otherwise mitigating the impact of ionizing radiation will be critical for realizing fault-tolerant superconducting quantum computers.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fiber-optic bolometers with high-temperature tolerance and reduced time constants for fusion plasma diagnostics

Fiber-optic bolometers (FOBs) designed for plasma radiation measurement in magnetically confined fusion environments have been previously developed and tested at the DIII-D tokamak. These FOBs utilize a silicon Fabry–Perot interferometer at the fiber tip for temperature measurement and a gold disk as a radiation absorber. This paper presents recent advancements in the development of FOBs with reduced cooling time constants and enhanced temperature tolerance. We also demonstrate high-temperature operation and report findings from irradiation tests. By incorporating a copper sensor holder as a thermal sink and integrating two closely packed sensor heads into a compact design, the cooling time constants were reduced to ∼100 ms in vacuum, while minimizing uncertainties caused by temperature gradients. The FOBs were subjected to heating at 400 °C for five hours, with no observed degradation in noise performance post-heating. High-temperature operation tests were conducted at ∼220 °C using a 404 nm square-wave modulated laser to simulate the plasma radiation. In addition, four FOBs constructed from copper-coated pure-silica fibers were fabricated and underwent irradiation testing, enduring a total γ-radiation dose of 15.2 MGy and a neutron fluence of 1.6 × 10 18 n/cm 2 . As a result, the FOBs maintained their physical integrity and the optical signal shows high visibility throughout the test.

42 ENGINEERING↗

Cryo-electron tomography related radiation-damage parameters for individual-molecule 3D structure determination

To understand the dynamic structure–function relationship of soft- and biomolecules, the determination of the three-dimensional (3D) structure of each individual molecule (nonaveraged structure) in its native state is sought-after. Cryo-electron tomography (cryo-ET) is a unique tool for imaging an individual object from a series of tilted views. However, due to radiation damage from the incident electron beam, the tolerable electron dose limits image contrast and the signal-to-noise ratio (SNR) of the data, preventing the 3D structure determination of individual molecules, especially at high-resolution. Although recently developed technologies and techniques, such as the direct electron detector, phase plate, and computational algorithms, can partially improve image contrast/SNR at the same electron dose, the high-resolution structure, such as tertiary structure of individual molecules, has not yet been resolved. Here, we review the cryo-electron microscopy (cryo-EM) and cryo-ET experimental parameters to discuss how these parameters affect the extent of radiation damage. This discussion can guide us in optimizing the experimental strategy to increase the imaging dose or improve image SNR without increasing the radiation damage. With a higher dose, a higher image contrast/SNR can be achieved, which is crucial for individual-molecule 3D structure. With 3D structures determined from an ensemble of individual molecules in different conformations, the molecular mechanism through their biochemical reactions, such as self-folding or synthesis, can be elucidated in a straightforward manner.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Challenges in solving structures from radiation-damaged tomograms of protein nanocrystals assessed by simulation

Structure-determination methods are needed to resolve the atomic details that underlie protein function. X-ray crystallography has provided most of our knowledge of protein structure, but is constrained by the need for large, well ordered crystals and the loss of phase information. The rapidly developing methods of serial femtosecond crystallography, micro-electron diffraction and single-particle reconstruction circumvent the first of these limitations by enabling data collection from nanocrystals or purified proteins. However, the first two methods also suffer from the phase problem, while many proteins fall below the molecular-weight threshold required for single-particle reconstruction. Cryo-electron tomography of protein nanocrystals has the potential to overcome these obstacles of mainstream structure-determination methods. Here, a data-processing scheme is presented that combines routines from X-ray crystallography and new algorithms that have been developed to solve structures from tomograms of nanocrystals. This pipeline handles image-processing challenges specific to tomographic sampling of periodic specimens and is validated using simulated crystals. The tolerance of this workflow to the effects of radiation damage is also assessed. The simulations indicate a trade-off between a wider tilt range to facilitate merging data from multiple tomograms and a smaller tilt increment to improve phase accuracy. Since phase errors, but not merging errors, can be overcome with additional data sets, these results recommend distributing the dose over a wide angular range rather than using a finer sampling interval to solve the protein structure.

59 BASIC BIOLOGICAL SCIENCES↗

Impact of ionizing radiation on superconducting qubit coherence

The practical viability of any qubit technology stands on long coherence times and high-fidelity operations with the superconducting qubit modality being an auspicious example, However, superconducting qubit coherence is impacted by broken Cooper pairs referred to as quasiparticles, with a density that is empirically observed to be orders of magnitude greater than the value predicted for thermal equilibrium by the Bardeen-Cooper-Schrieffer (BCS) theory of superconductivity. Previous work has shown that infrared photons significantly increase the quasiparticle density, yet even in the best isolated systems, it still remains higher than expected, suggesting that another generation mechanism exists. In this Letter, we provide evidence that ionizing radiation from environmental radioactive materials and cosmic rays contributes to this observed difference, leading to an elevated quasiparticle density that would ultimately limit superconducting qubits of the type measured here to coherence times in the millisecond regime. Additionally, we further demonstrate that introducing radiation shielding reduces the flux of ionizing radiation and positively correlates with increased coherence time. Albeit a small effect for today’s qubits, reducing or otherwise mitigating the impact of ionizing radiation will be critical for realizing fault-tolerant superconducting quantum computers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Radiation response of FeCrAl-coated Zircaloy-4

Coating the surface of Zircaloy-4 light water reactor fuel cladding tube is of considerable interest for enhancing its accident tolerance. In this study, thermal annealing of FeCrAl-coated Zircaloy-4 at 725 °C for 500 h, was used to induce interfacial reactions between Zircaloy-4 and FeCrAl. The interface zones were then irradiated by 3.5 MeV Zr ions at 400 °C, up to 50, 100, 150 peak dpa values. Transmission electron microscopy (TEM) and scanning TEM were used to characterize microstructural and composition changes before and after ion irradiation. Three interfacial phases were identified: FeZr 3 , (Fe,Cr) 2 Zr, and ZrC. The widest intermetallic layer, FeZr3, had large grains. The narrower phases, (Fe,Cr)2Zr and ZrC, contained small grains and were often mixed. The unexpected observation of the ZrC phase was attributed to the presence of very small impurity level concentrations of carbon in the powder material. No void swelling was observed in any of the phases, including the FeCrAl coating and Zircaloy-4 substrate. (Fe,Cr) 2 Zr, however, fully amorphized after irradiation, even at the lowest dpa.

36 MATERIALS SCIENCE↗

International Recommendations on Reirradiation by Intensity Modulated Radiation Therapy for Locally Recurrent Nasopharyngeal Carcinoma

Reirradiation for locally recurrent nasopharyngeal carcinoma (NPC) is challenging because prior radiation dose delivered in the first course is often close to the tolerance limit of surrounding normal structures. A delicate balance between achieving local salvage and minimizing treatment toxicities is needed. However, high-level evidence is lacking because available reports are mostly retrospective studies on small series of patients. Pragmatic consensus guidelines, based on an extensive literature search and the pooling of opinions by leading specialists, will provide a useful reference to assist decision-making for these difficult decisions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Helium effects and bubbles formation in irradiated Ti 3 SiC 2

Ti 3 SiC 2 is a potential structural material for nuclear reactor applications. However, He irradiation effects in this material are not well understood, especially at high temperatures. Here, we compare the effects of He irradiation in Ti 3 SiC 2 at room temperature (RT) and at 750 °C. Irradiation at 750 °C was found to lead to extremely elongated He bubbles that are concentrated in the nano-laminate layers of Ti 3 SiC 2 , whereas the overall crystal structure of the material remained intact. In contrast, at RT, the layered structure was significantly damaged and highly disordered after irradiation. Our study reveals that at elevated temperatures, the unique structure of Ti 3 SiC 2 can accommodate large amounts of He atoms in the nano-laminate layer, without compromising the structural stability of the material. The structure and the mechanical tests results show that the irradiation induced swelling and hardening at 750 °C are much smaller than those at RT. Overall, these results indicate that Ti 3 SiC 2 has an excellent resistance to accumulation of radiation-induced He impurities and that it has a considerable tolerance to irradiation-induced degradation of mechanical properties at high temperatures.

36 MATERIALS SCIENCE↗