Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reference Standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Combining RNA-SEQ Datasets from NASA GENELAB: An Evaluation of Correction Methods

Background: Conducting space biology experiments aboard the International Space Station, particularly those utilizing complex model organisms like mice, is expensive and difficult due to limited crew availability, hardware, and space. As a result, sample numbers from these studies are low, reducing the statistical power of any one experiment. Aggregating spaceflight datasets serves as a method to increase sample numbers, allowing for novel insights through bioinformatic analysis of ‘omics data from merged datasets. However, aggregating datasets can introduce unwanted variation including 1) differences in sample handling, processing, and sequencing platforms between datasets (technical variation) as well as 2) differences in experimental design between datasets. Methods: In the present study, NASA GeneLab-hosted RNAseq datasets from mouse liver tissues were used to evaluate several statistical methods to correct for this unwanted variation through two approaches, reference-based and standard. The following correction algorithms were applied with (reference-based) and/or without (standard) considering Universal Mouse RNA Reference samples: ComBat and ComBat_seq from the SVA package, the median polish, empirical Bayes, and ANOVA-based algorithms from the MBatch package, and negative binomial regression normalization in the DESeq2 package. For each approach, after the correction algorithm was applied, differential gene expression (DGE) analysis of flight and ground control samples was performed with the combined data. The robustness of each tool was evaluated using BatchQC to determine statistical differences between datasets before and after correction, Principal Component Analysis to evaluate global gene expression in samples before and after correction, and by comparing DGE analysis of individual datasets and combined datasets before and after correction. Results: The results showed that the reference-based approach introduced several additional (and likely artificial) differentially expressed genes when compared with the respective standard approach. Conclusions: Of the methods tested, standard ComBat_seq and DESeq2 were identified as the most robust correction methods for combining spaceflight mouse liver RNAseq datasets hosted on GeneLab.

Finsam Samson↗

Application of IRIG 106 Digital Data Recorder Standards for Flight Test

During flight tests, data is acquired from different sources and in different formats. Sensor data, aircraft avionics bus data, time, voice and video are essential for analysis of these flight tests. IRIG 106 standards exist for recording and transferring these data types. However, to enhance interoperability of flight test data between (multinational) test teams, a standard was needed to encapsulate all these data types. For this purpose the Telemetry Group of the Range Commanders Council (RCC) first published in 2004 the IRIG 106 Chapter 10 Standard, “Solid-State On-Board Recorder Standard”. This standard is evolving up to present. This AGARDograph gives an introduction to the standard, explains how the standard is positioned among other relevant standards, and describes the equipment and their application in flight tests with some examples. The topics covered include IRIG 106 Chapter 10 compatible recording of (multiple) data streams, synchronization of data, data recorders, data retrieval, data processing, and examples of flight test programs. Further development of the standard, originally published for on-board recorders, is described for extending the requirements for ground-based data recorders. The last chapter addresses a number of issues related to the application of the Chapter 10 standard with references to information and possible solutions. This document shows how data acquisition and data processing in accordance to IRIG 106 Chapter 10 standard can be applied in NATO flight tests and will thereby contribute to collaboration and cost efficiency.

flight test instrumentation↗

The NASA Marshall Space Flight Center Earth Global Reference Atmospheric Model-2010 Version

Reference or standard atmospheric models have long been used for design and mission planning of various aerospace systems. The NASA Marshall Space Flight Center Global Reference Atmospheric Model was developed in response to the need for a design reference atmosphere that provides complete global geographical variability and complete altitude coverage (surface to orbital altitudes), as well as complete seasonal and monthly variability of the thermodynamic variables and wind components. In addition to providing the geographical, height, and monthly variation of the mean atmospheric state, it includes the ability to simulate spatial and temporal perturbations.

Leslie, F. W.↗

Portable Wireless LAN Device and Two-way Radio Threat Assessment for Aircraft Navigation Radios

Measurement processes, data and analysis are provided to address the concern for Wireless Local Area Network devices and two-way radios to cause electromagnetic interference to aircraft navigation radio systems. A radiated emission measurement process is developed and spurious radiated emissions from various devices are characterized using reverberation chambers. Spurious radiated emissions in aircraft radio frequency bands from several wireless network devices are compared with baseline emissions from standard computer laptops and personal digital assistants. In addition, spurious radiated emission data in aircraft radio frequency bands from seven pairs of two-way radios are provided, A description of the measurement process, device modes of operation and the measurement results are reported. Aircraft interference path loss measurements were conducted on four Boeing 747 and Boeing 737 aircraft for several aircraft radio systems. The measurement approach is described and the path loss results are compared with existing data from reference documents, standards, and NASA partnerships. In-band on-channel interference thresholds are compiled from an existing reference document. Using these data, a risk assessment is provided for interference from wireless network devices and two-way radios to aircraft systems, including Localizer, Glideslope, Very High Frequency Omnidirectional Range, Microwave Landing System and Global Positioning System. The report compares the interference risks associated with emissions from wireless network devices and two-way radios against standard laptops and personal digital assistants. Existing receiver interference threshold references are identified as to require more data for better interference risk assessments.

Nguyen, Truong X.↗

Alignment verification procedures

In alignment verification procedures each laboratory is required to align its test machines and gripping fixtures to produce a nearly uniform tensile stress field on an un-notched sheet specimen. The blank specimens (50 mm w X 305 mm l X 2.3 mm th) supplied by the coordinators were strain gauged. Strain gauge readings were taken at all gauges (n = 1 through 10). The alignment verification procedures are as follows: (1) zero all strain gauges while specimen is in a free-supported condition; (2) put strain-gauged specimen in the test machine so that specimen front face (face 1) is in contact with reference jaw (standard position of specimen), tighten grips, and at zero load measure strains on all gauges. (epsilon sub nS0 is strain at gauge n, standard position, zero load); (3) with specimen in machine and at a tensile load of 10 kN measure strains (specimen in standard position). (Strain = epsilon sub nS10); (4) remove specimen from machine. Put specimen in machine so that specimen back face (face 2) is in contact with reference jaw (reverse position of specimen), tighten grips, and at zero load measure strains on all gauges. (Strain - epsilon sub nR0); and (5) with specimen in machine and at tensile load of 10 kN measure strains (specimen in reverse position). (epsilon sub nR10 is strain at gauge n, reverse position, 10 kN load).

Edwards, P. R.↗

Standard surface-reflectance model and illuminant estimation

A vector analysis technique was adopted to test the standard reflectance model. A computational model was developed to determine the components of the observed spectra and an estimate of the illuminant was obtained without using a reference white standard. The accuracy of the standard model is evaluated.

Tominaga, Shoji↗

Wintertime density perturbations near 50 km in relation to latitude

Standard and reference atmospheres which depict the horizontal distribution of air density in the stratosphere and mesosphere are not realistic in that they do not provide information on the large departures from standard that may occur during a given month, nor on the time- and space-scales of atmospheric perturbations responsible for these departures. In the present paper, it is shown how this information can be obtained from a special analysis of satellite radiance measurements. Plots of the mean zonal radiance, obtained with the VTPR instrument, and the corresponding 50-km density show not only the expected strong poleward gradient of density, but also a strong density surge from late December to early January, affecting all latitudes.

Quiroz, R. S.↗

Definition of spacecraft standard interfaces by the NASA Space Assembly and Servicing Working Group (SASWG)

The purpose of the NASA Space Assembly and Servicing Working Group (SASWG) is to study enabling technologies for on-orbit spacecraft maintenance and servicing. One key technology required for effective space logistics activity is the development of standard spacecraft interfaces, including the 'Basic Set' defined by NASA, the U.S. Space Command, and industry panelists to be the following: (1) navigation aids; (2) grasping, berthing, and docking; and (3) utility connections for power, data, and fluids. Draft standards have been prepared and referred to professional standards organizations, including the AIAA, EIA, and SAE space standards committee. The objective of the SASWG is to support these committees with the technical expertise required to prepare standards, guidelines, and recommended practices which will be accepted by the ANSI and international standards organizations, including the ISO, IEC, and PASC.

Radtke, Robert↗

A two-year history of atomic frequency standards syntonization in the Deep Space Network

The frequency and timing system (FTS) of the Deep Space Network (DSN) consists of a collection of three sets of clocks driven by independent atomic oscillators. The synchronization of the output frequencies (syntonization) of these oscillators (reference frequency standards) is reported. There is an implied specification of a + or - 5.5 X 10 to the 12th power related to the DSN time synchronization specification of a + or - 100 microseconds. Both the syntonization within the three sets and the syntonization of the sets to the international standard (International Atomic Time) are considered.

Ward, S. C.↗

An Optimal Control Modification to Model-Reference Adaptive Control for Fast Adaptation

This paper presents a method that can achieve fast adaptation for a class of model-reference adaptive control. It is well-known that standard model-reference adaptive control exhibits high-gain control behaviors when a large adaptive gain is used to achieve fast adaptation in order to reduce tracking error rapidly. High gain control creates high-frequency oscillations that can excite unmodeled dynamics and can lead to instability. The fast adaptation approach is based on the minimization of the squares of the tracking error, which is formulated as an optimal control problem. The necessary condition of optimality is used to derive an adaptive law using the gradient method. This adaptive law is shown to result in uniform boundedness of the tracking error by means of the Lyapunov s direct method. Furthermore, this adaptive law allows a large adaptive gain to be used without causing undesired high-gain control effects. The method is shown to be more robust than standard model-reference adaptive control. Simulations demonstrate the effectiveness of the proposed method.

Nguyen, Nhan T.↗

Evaluation of the Applicability of Solar and Lamp Radiometric Calibrations of a Precision Sun Photometer Operating Between 300 and 1025 nm

Over a period of 3 year a precision Sun photometer (SPM) operating between 300 and 1025 nm was calibrated four times at three different high-mountain sites in Switzerland, Germany, and the United States by means of the Langley-plot technique. We found that for atmospheric window wavelengths the total error (2 sigma-statistical plus systematic errors) of the calibration constants V(sub 0)(lambda), the SPM voltage in the absence of any attenuating atmosphere, can be kept below 1.60% in the UV-A and blue, 0.9% in the mid-visible, and 0.6% in the near-infra red spectral region. For SPM channels within strong water-vapor or ozone absorption bands a modified Langley-plot technique was used to determine V(sub 0)(lambda) with a lower accuracy. Within the same period of time, we calibrated the SPM five times using irradiance standard lamps in the optical labs of the Physikalisch-Meteorologisches Observatorium Davos and World Radiation Center, Switzerland, and of the Remote Sensing Group of the Optical Sciences Center, University of Arizona, Tucson, Arizona. The lab calibration method requires knowledge of the extraterrestrial spectral irradiance. When we refer the standard lamp results to the World Radiation Center extraterrestrial solar irradiance spectrum, they agree with the Langley results within 2% at 6 or 13 SPM wavelengths. The largest disagreement (4.4%) is found for the channel centered at 610 nm. The results of these intercomparisons change significantly when the lamp results are referred to two different extraterrestrial solar irradiance spectra that have become recently available.

Schmid, Beat↗

Wireless Phone Threat Assessment and New Wireless Technology Concerns for Aircraft Navigation Radios

To address the concern for cellular phone electromagnetic interference to aircraft radios, a radiated emission measurement process was developed for two dominant digital standards of wireless handsets. Spurious radiated emissions were efficiently characterized from devices tested in either a semi-anechoic or reverberation chamber, in terms of effective radiated power. Eight representative handsets (four from each digital standard) were commanded to operate while varying their radio transmitter parameters (power, modulation, etc.). This report provides a detailed description of the measurement process and resulting data, which may subsequently be used by others as a basis of consistent evaluation of other portable transmitters using a variety of wireless transmission protocols. Aircraft interference path loss and navigation radio interference threshold data from numerous reference documents, standards, and NASA partnerships were compiled. Using these data, a preliminary risk assessment is provided for wireless phone interference to aircraft Localizer, Glideslope, Very High Frequency Omni directional Range, and Global Positioning Satellite radio receivers on typical transport airplanes. The report identifies where existing data for device emissions, interference path loss, and navigation radio interference thresholds need to be extended for an accurate risk assessment for wireless transmitters in aircraft.

Ely, Jay J.↗

Influence of sky radiance distribution on the ratio technique for estimating bidirectional reflectance

The technique of ratioing scene radiance to the radiance obtained from standard Lambertian reference panels in order to estimate bidirectional reflectance factors may depend on the angular distribution of the diffuse irradiance field as well as the direct solar irradiance. A simulation study was performed to estimate the magnitude of this effect for differing clear sky irradiance distributions for a variety of vegetated surfaces. For the seven surfaces and wavelengths analyzed, the error induced in the estimation of bidirectional reflectance factors using the standard ratio technique was less than 5 percent for zenith view and sun angles less than 55 degrees.

Kirchner, J. A.↗

Interpretation and classification of microvolt T wave alternans tests

Measurement of microvolt-level T wave alternans (TWA) during routine exercise stress testing now is possible as a result of sophisticated noise reduction techniques and analytic methods that have become commercially available. Even though this technology is new, the available data suggest that microvolt TWA is a potent predictor of arrhythmia risk in diverse disease states. As this technology becomes more widely available, physicians will be called upon to interpret microvolt TWA tracings. This review seeks to establish uniform standards for the clinical interpretation of microvolt TWA tracings.

NASA Discipline Cardiopulmonary↗

Venus Global Reference Atmospheric Model (Venus-GRAM) Upgrades

Introduction: The Venus Global Reference Atmospheric Model (Venus-GRAM) is one of the most widely used engineering models of Venus’ atmosphere. The Venus-GRAM upgrades are being developed by NASA Marshall Space Flight Center (MSFC) and NASA Langley Research Center (LaRC). This presentation will provide details regarding the upgrades that have been made to Venus-GRAM and the ongoing objectives, tasks, and milestones related to the GRAM upgrades funded by the NASA Science Mission Directorate (SMD). Venus-GRAM: Venus-GRAM is an engineering-oriented atmospheric model that estimates mean values and statistical variations of the atmospheric properties of Venus. Venus-GRAM provides mean values and variability for any point in the atmosphere as well as seasonal, geographic, and altitude variations. Venus-GRAM outputs include atmospheric density, temperature, pressure, winds, and chemical composition along a user-defined path. It is extensively used by the engineering community because of its ability to create realistic dispersions. GRAMs have been integrated into high fidelity flight dynamic simulations of launch, entry, descent and landing (EDL), aerobraking and aerocapture. GRAMs are currently available for Earth, Mars, Venus, Neptune, Titan, and Uranus. The lower atmosphere model in Venus-GRAM (up to 250 km) is based on the Venus International Reference Atmosphere (VIRA) [1]. The Venus-GRAM thermosphere (250 to 1000 km) is based on a MSFC-developed model [2] which assumes an isothermal temperature profile initialized using VIRA conditions at 250 km [3]. The VIRA version included in Venus-GRAM includes Pioneer Venus Orbiter and Probe data as well as Venera probe data, but it does not include a solid planet model or a high-resolution gravity model [4]. Venus-GRAM Upgrade Status: Code Modernization. Venus-GRAM has been rearchitected from Fortran to a common object-oriented C++ framework called the GRAM Suite. This new architecture creates a common GRAM library of data models and utilities. The first C++ release of the rearchitected Venus-GRAM is a straight conversion from the latest Fortran version. Model Upgrades. The focus of the model upgrade task is to improve the atmosphere models in the existing GRAMs and to establish a foundation for developing GRAMs for additional destinations. The GRAM ephemeris has been upgraded to the NASA Navigation and Ancillary Information Facility (NAIF) SPICE toolkit (version N0066). The calculation of the speed of sound has also been improved in the GRAMs. In FY20, the GRAM project established contracts to improve the model data within Venus-GRAM. Hampton University is developing an empirical global model for Venus. The University of Wisconsin is reanalyzing the Venus Express radio occultation observations and analyzing the Akatsuki thermal imaging data. Upgraded Venus-GRAM Release. GRAM Suite Version 1.3 will be released in September 2021 and will contain the rearchitected Venus-GRAM, including the common GRAM framework and planet–specific code. A User Guide and Programmer’s Manual are released with all GRAMs. Conclusions: GRAMs are frequently used toolsets and vital in assessing effects of atmospheres on interplanetary spacecraft during the program life cycle process. Releases of the GRAM Suite, upgrades of the existing planetary GRAMs, and development of new planetary GRAMs are ongoing. Venus-GRAM atmosphere model upgrades will be included in the next phase of GRAM tasks. References: [1] Kliore, A. J. et al. (1985) ASR, 5, 11, 1-304. [2] Justh, H. L. et al. (2006) AIAA/AAS Astrodynamics Specialist Conference & Exhibit, Abstract AIAA-2006-6394. [3] Guide to Reference and Standard Atmosphere Models, BSR/AIAA G-003-2010. [4] Limaye, S. S. (2012), LPSC VEXAG Townhall Meeting. Acknowledgments: The authors gratefully acknowledge support from the NASA SMD.

atmospheric models↗

Mercury Trapped Ion Frequency Standard for Ultra-Stable Reference Applications

An atomic clock including an ion trap assembly, a C-field coil positioned for generating a first magnetic field in the interrogation region of the ion trap assembly, a compensation coil positioned for generating a second magnetic field in the interrogation region, wherein the combination of the first and second magnetic fields produces an ion number-dependent second order Zeeman shift (Zeeman shift) in the resonance frequency that is opposite in sign to an ion number-dependent second order Doppler shift (Doppler shift) in the resonance frequency, the C-field coil has a radius selected using data indicating how changes in the radius affect an ion-number-dependent shift in the resonance frequency, such that a difference in magnitude between the Doppler shift and the Zeeman shift is controlled or reduced, and the resonance frequency, including the adjustment by the Zeeman shift, is used to obtain the frequency standard.

Burt, Eric A.↗

Calibrated Noise Measurements with Induced Receiver Gain Fluctuations

The lack of well-developed techniques for modeling changing statistical moments in our observations has stymied the application of stochastic process theory in science and engineering. These limitations were encountered when modeling the performance of radiometer calibration architectures and algorithms in the presence of non stationary receiver fluctuations. Analyses of measured signals have traditionally been limited to a single measurement series. Whereas in a radiometer that samples a set of noise references, the data collection can be treated as an ensemble set of measurements of the receiver state. Noise Assisted Data Analysis is a growing field of study with significant potential for aiding the understanding and modeling of non stationary processes. Typically, NADA entails adding noise to a signal to produce an ensemble set on which statistical analysis is performed. Alternatively as in radiometric measurements, mixing a signal with calibrated noise provides, through the calibration process, the means to detect deviations from the stationary assumption and thereby a measurement tool to characterize the signal's non stationary properties. Data sets comprised of calibrated noise measurements have been limited to those collected with naturally occurring fluctuations in the radiometer receiver. To examine the application of NADA using calibrated noise, a Receiver Gain Modulation Circuit (RGMC) was designed and built to modulate the gain of a radiometer receiver using an external signal. In 2010, an RGMC was installed and operated at the National Institute of Standards and Techniques (NIST) using their Noise Figure Radiometer (NFRad) and national standard noise references. The data collected is the first known set of calibrated noise measurements from a receiver with an externally modulated gain. As an initial step, sinusoidal and step-function signals were used to modulate the receiver gain, to evaluate the circuit characteristics and to study the performance of a variety of calibration algorithms. The receiver noise temperature and time-bandwidth product of the NFRad are calculated from the data. Statistical analysis using temporal-dependent calibration algorithms reveals that the natural occurring fluctuations in the receiver are stationary over long intervals (100s of seconds); however the receiver exhibits local non stationarity over the interval over which one set of reference measurements are collected. A variety of calibration algorithms have been applied to the data to assess algorithms' performance with the gain fluctuation signals. This presentation will describe the RGMC, experiment design and a comparative analysis of calibration algorithms.

Racette, Paul↗

High performance liquid chromatographic assay for the quantitation of total glutathione in plasma

A simple and widely used homocysteine HPLC procedure was applied for the HPLC identification and quantitation of glutathione in plasma. The method, which utilizes SBDF as a derivatizing agent utilizes only 50 microl of sample volume. Linear quantitative response curve was generated for glutathione over a concentration range of 0.3125-62.50 micromol/l. Linear regression analysis of the standard curve exhibited correlation coefficient of 0.999. Limit of detection (LOD) and limit of quantitation (LOQ) values were 5.0 and 15 pmol, respectively. Glutathione recovery using this method was nearly complete (above 96%). Intra-assay and inter-assay precision studies reflected a high level of reliability and reproducibility of the method. The applicability of the method for the quantitation of glutathione was demonstrated successfully using human and rat plasma samples.

Non-NASA Center↗