Search NASA⌕ Search

SEARCH · Search NASA

Results for “SIGNAL DISCRIMINATOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

246 records · Page 14

Measurement of muon neutrino charged-current quasielasticlike cross section using off-axis NuMI beam at ICARUS

This paper presents the first neutrino cross-section measurement from the ICARUS detector at Fermilab, using Neutrinos at the Main Injector (NuMI) beam data collected from two beam operation periods corresponding to 2.5 × 10 20 protons-on-target in neutrino beam mode. The signal is defined by events with no pions produced in the final state, a topology dominated by charged-current quasielasticlike signatures. The measurement is reported as flux-averaged differential cross sections as functions of kinematic variables that provide sensitivity to the complex nuclear effects that often dominate the systematic uncertainty budgets of neutrino oscillation measurements. Specifically, this work reports cross sections in two angular variables—the angle of the outgoing lepton and the opening angle between the lepton and leading proton—and two variables characterizing the kinematic imbalance between the muon and proton in the plane transverse to the incoming neutrino. These results are compared against predictions from a variety of neutrino event generators, with p values calculated between the extracted cross sections and each prediction. Overall, the predictions agree with the data; however, the current budget of uncertainties does not yet provide sufficient discriminating power to favor a specific model.

Abd Alrahman, F. [Houston U.]↗

Scalability Analysis of Quantum Models for Stress and Emotion Detection

Stress and emotion detection from high-dimensional physiological signals is a challenging task, particularly when aiming for accurate classification across diverse behavioral states. Quantum machine learning (QML) is promising for modeling such high-dimensional data, but scalability is limited by qubit resources and the exponential cost of classical statevector simulation. This work studies the scalability of quantum support vector machines (QSVMs) for binary stress detection and three-class emotion recognition (Negative/Neutral/Positive) under varying qubit counts and angle-encoding strategies. We also present a comparison study with one-feature-per-qubit (1:1) and two-features-per-qubit (2:1) mappings. Experiments are executed on HPC infrastructure using NVIDIA CUDA-Q to evaluate performance, variance, and class-dependent separability at higher-qubit setups. Results show that larger Hilbert spaces can improve peak accuracy but may increase instability. At the same time, dense 2:1 encoding yields more consistent stress detection performance. For emotion recognition, scaling improves discrimination for classes like Negative and Positive more than Neutral. We find that effective QML scaling is task-dependent and benefits more from encoding design than simply increasing qubit count.

Onim, Md. Saif Hassan [University of Tennessee, Kn↗

Super resolution for root imaging

Premise High‐resolution cameras are very helpful for plant phenotyping as their images enable tasks such as target vs. background discrimination and the measurement and analysis of fine above‐ground plant attributes. However, the acquisition of high‐resolution images of plant roots is more challenging than above‐ground data collection. An effective super‐resolution (SR) algorithm is therefore needed for overcoming the resolution limitations of sensors, reducing storage space requirements, and boosting the performance of subsequent analyses. Methods We propose an SR framework for enhancing images of plant roots using convolutional neural networks. We compare three alternatives for training the SR model: (i) training with non‐plant‐root images, (ii) training with plant‐root images, and (iii) pretraining the model with non‐plant‐root images and fine‐tuning with plant‐root images. The architectures of the SR models were based on two state‐of‐the‐art deep learning approaches: a fast SR convolutional neural network and an SR generative adversarial network. Results In our experiments, we observed that the SR models improved the quality of low‐resolution images of plant roots in an unseen data set in terms of the signal‐to‐noise ratio. We used a collection of publicly available data sets to demonstrate that the SR models outperform the basic bicubic interpolation, even when trained with non‐root data sets. Discussion The incorporation of a deep learning–based SR model in the imaging process enhances the quality of low‐resolution images of plant roots. We demonstrate that SR preprocessing boosts the performance of a machine learning system trained to separate plant roots from their background. Our segmentation experiments also show that high performance on this task can be achieved independently of the signal‐to‐noise ratio. We therefore conclude that the quality of the image enhancement depends on the desired application.

Ruiz‐Munoz, Jose F.↗

Development of a Convolutional Neural Network Classifier for Data Starved Spectra - 20199

The Institute for Clean Energy Technology (ICET) at Mississippi State University is exploring the utility of machine learning in augmenting its mobile radiation surveying platforms, which are currently being developed as means to survey depleted uranium contaminated areas in support of remediation and decommissioning efforts. Mobile survey platforms provide a means to efficiently scan large areas of interest while reducing human exposure to radiation and other hazards. The survey platforms can also be used for scanning for any gamma emitting isotope in addition to depleted uranium. The spectral data that the platforms collect may be data starved with relatively low counts and poorly defined spectral features depending on the speed of the platforms and scintillation detector selection. Such data-starved spectra are difficult to use for isotope identification, requiring advanced knowledge of the possible radionuclides that could be present and environmental factors that could attenuate signals or introduce background noise. These factors in combination with the volume of survey data increases the time it takes to perform analysis of survey data when the source type is unknown. There are a number of algorithms in the field of machine learning that can be used to classify data that would be challenging and time-consuming for a human to identify. Supervised machine learning algorithms train models based on extensive amounts of human-labeled training data. Once sufficiently trained, these models can be used to quickly make high-fidelity predictions on new data. Convolutional neural networks are machine learning algorithms that excel in learning representations of 'shapes'. They do this by taking numerical input data and convolving them with spatial feature detectors referred to as filters. These filters are incrementally adjusted to reduce the prediction error on the data during the backpropagation step of training. Discussed in this paper is the development of a convolutional neural network classifier (CNNC) that can utilize spectral survey data for source discrimination and isotope identification. Bench-top laboratory experiments data using LaBr{sub 3}(Ce) scintillation detectors were used to train and evaluate the performance of the developed CNNC. The CNNC is capable of discriminating a variety of gamma emitting source types, differentiating different forms of uranium (depleted vs. natural), and estimating the amount of uranium for a known geometry. The discussed CNNC may be useful in scenarios where survey systems are deployed in situations where hazardous radioactive material maybe present, but the type is unknown. When used in remediation applications the CNNC can be used to screen-out false positives, helping reduce remediation costs. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Performance of the ATLAS RPC detector and Level-1 muon barrel trigger at √(s)=13 TeV

The ATLAS experiment at the Large Hadron Collider (LHC) employs a trigger system consisting of a first-level hardware trigger (L1) and a software-based high-level trigger. The L1 muon trigger system selects muon candidates, assigns them to the correct LHC bunch crossing and classifies them into one of six transverse-momentum threshold classes. The L1 muon trigger system uses resistive-plate chambers (RPCs) to generate the muon-induced trigger signals in the central (barrel) region of the ATLAS detector. The ATLAS RPCs are arranged in six concentric layers and operate in a toroidal magnetic field with a bending power of 1.5 to 5.5 Tm. The RPC detector consists of about 3700 gas volumes with a total surface area of more than 4000 m2. This paper reports on the performance of the RPC detector and L1 muon barrel trigger using 60.8 fb-1 of proton-proton collision data recorded by the ATLAS experiment in 2018 at a centre-of-mass energy of 13 TeV. Detector and trigger performance are studied using Z boson decays into a muon pair. Measurements of the RPC detector response, efficiency, and time resolution are reported. Measurements of the L1 muon barrel trigger efficiencies and rates are presented, along with measurements of the properties of the selected sample of muon candidates. Measurements of the RPC currents, counting rates and mean avalanche charge are performed using zero-bias collisions. Finally, RPC detector response and efficiency are studied at different high voltage and front-end discriminator threshold settings in order to extrapolate detector response to the higher luminosity expected for the High Luminosity LHC.

47 OTHER INSTRUMENTATION↗

High-bandwidth frequency domain multiplexed readout of transition-edge sensors for neutrinoless double beta decay searches

The next-generation of cryogenic neutrinoless double-beta decay experiments require increasingly fast readout in order to improve background discrimination. These experiments, operated as cryogenic calorimeters at ∼ 10 mK, are usually read out by high-impedance neutron transmutation doped (NTD) thermistors, which provide good energy resolution, but are limited by ∼ 1 ms response times. Superconducting detectors, such as transition-edge sensors (TESs) with a time resolution of ∼ 100 μs, offer superior timing performance over NTD semiconductor bolometers. To make this technology viable for an application to a thousand or more channels, multiplexed readout is necessary in order to minimize the thermal load and radioactive contamination induced by the readout. Frequency-domain multiplexing readout (fMUX) for TESs, previously developed at Berkeley Lab and McGill University, is currently in use for mm-wave telescopes with detector sampling rates in the order of 100 Hz. We demonstrate a new readout system, based on the McGill/Berkeley digital fMux readout, to satisfy the higher bandwidth and noise requirements of the next generation of TES-instrumented cryogenic calorimeters. Each multiplexing readout module comprises 10 superconducting resonators in the 1–5 MHz range and a DC superconducting quantum interference device (DC-SQUID), interfaced to high-speed field programmable gate array (FPGA)-based electronics for digital signal processing and low-latency SQUID feedback. The new readout samples detectors at 156 kHz, three orders of magnitude faster than its cosmology-oriented predecessor, and demonstrates a stable feedback bandwidth of 3 kHz in a real TES-based system.

47 OTHER INSTRUMENTATION↗

Characterization of a Pixelated Cadmium Telluride Detector System Using a Polychromatic X-Ray Source and Gold Nanoparticle-Loaded Phantoms for Benchtop X-Ray Fluorescence Imaging

In this paper, the imaging dose and scan time have been considered as the two major constraints for routine benchtop x-ray fluorescence computed tomography (XFCT) imaging. One way to address this issue is to acquire x-ray fluorescence (XRF) signals in parallel through a 2D array of single-crystal detectors or a pixelated detector along with the cone-beam x-ray source. To identify a detector system suitable for this purpose, a commercially available, fully spectroscopic cadmium telluride (CdTe) pixelated detector, HEXITEC (High-Energy X-ray Imaging Technology), was tested under the experimental conditions optimized for benchtop XFCT imaging of gold nanoparticles (GNPs). Specifically, two different parallel-hole stainless steel collimators were fabricated and coupled with the detector for seamless integration into our existing benchtop cone-beam XFCT system. After the detector deployment, this benchtop XFCT system was used to detect XRF photons from GNP-loaded phantoms. A pixel-merging algorithm was introduced to enhance the sensitivity of XRF photon detection thereby minimizing the scan time. The effect of pixel-level charge sharing correction algorithms was investigated within the context of benchtop XFCT imaging. The detector energy resolution, in terms of the full width at half maximum (FWHM) values at different gold K-shell XRF energies, was also determined. Of the two charge sharing correction algorithms examined, the charge sharing addition gave better sensitivity than the charge sharing discrimination (csd). On the other hand, under the current experimental conditions, the energy resolution of the HEXITEC detector was the best with the csd and estimated to be 1.56 keV FWHM at 66-69 keV photon energy. Overall, despite some degradation of the detector energy resolution (compared with typical single crystal CdTe detectors), the HEXITEC detector enabled parallel data acquisition under the experimental conditions typical of benchtop XFCT imaging and operated well within our benchtop XFCT setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mid-Atlantic US observations of radiocarbon in CO 2 : fossil and biogenic source partitioning and model evaluation

Accurately quantifying regional anthropogenic CO 2 fluxes is fundamental to improving our understanding of the carbon cycle and for creating effective carbon mitigation policies, and the radiocarbon to total carbon ratio in atmospheric CO 2 (Δ 14 CO 2 ) is a robust tracer of fossil fuel CO 2 that can discriminate between biogenic and fossil fuel CO 2 sources. NASA's Atmospheric Carbon and Transport-America (ACT-America) airborne mission between 2016 and 2019 aimed to improve the accuracy of regional greenhouse gas flux estimates, through refining our understanding and characterization of fluxes and flux uncertainties in models. Δ 14 CO 2 observations from 26 flights are presented for examining seasonal CO 2 source partitioning in the Mid-Atlantic USA. Observed variability in boundary layer CO 2 at timescales ranging from intra-day to seasonal was largely driven by biogenic CO 2 (CO 2bio ) variability that ranged from −19.7 ppm in summer to 16.2 ppm in fall, while fossil fuel CO 2 (CO 2ff ) variability remained at 3.3±2.0 ppm. Carbonyl sulfide uptake was well-correlated with CO 2bio uptake, and examining this relationship, as well as that between CO 2 and CO 2bio variability reinforces the seasonal extent of gross primary productivity response throughout ACT-America. We use airborne Δ 14 CO 2 flask sampling alongside in situ carbon monoxide measurements to calculate high-frequency CO 2ff and evaluate the magnitude and diurnal variability of modeled CO 2ff , deducing likely transport errors in an example flight. Although ACT-America CO 2ff signals were attenuated due to the broad source regions sampled, results illustrate the value of Δ 14 CO 2 sampling and observation-based methodologies for regional CO 2 flux attribution, evaluation and improvement of modeled CO 2 .

Baier, Bianca C. [National Oceanic and Atmospheric↗

Contrasting Time-Frequency Representations for Unknown Waveform Detection

In real-world applications like spectrum management and interference detection, dealing with unseen electromagnetic waveforms is critical. Although some methods attempt to simulate open set data using generator models, they face challenges in generating synthetic samples for open set while simultaneously selecting an optimal discriminator for accurate classification. This results in difficulties capturing distinctive features across classes, especially in dynamic scenarios where new classes emerge. To detect unseen waveforms, we propose combining time and frequency domain features with cosine similarity loss to enhance feature distinctiveness and enabling more accurate predictions. This approach efficiently captures more comprehensive information than single-domain representations or approaches without cosine loss. Additionally, our model avoids generic feature vectors by extracting class-specific features during training, resulting in improved class representation. The experiment results show that this combined feature approach with cosine loss outperforms single-domain models and improves accuracy by 10\% over models without cosine loss.

99 - GENERAL AND MISCELLANEOUS↗

High-Spectral Resolution Lidar (HSRL) Instrument Handbook

High-spectral-resolution lidar (HSRL) systems provide vertical profiles of optical depth, backscatter cross-section, depolarization, and backscatter phase function. All HSRL measurements are calibrated by reference to molecular scattering, which is measured at each point in the lidar profile. Like the Raman lidar (RL), but unlike simple backscatter lidars such as the micropulse lidar (MPL), this enables the HSRL to measure backscatter cross-sections and optical depths without prior assumptions about the scattering properties of the atmosphere. The depolarization observations allow robust discrimination between ice and water clouds. Rigorous error estimates can be computed for all measurements. A very narrow angular field of view reduces multiple scattering contributions. The small field of view, coupled with a narrow optical bandwidth, nearly eliminates noise due to scattered sunlight. The laser transmitter is a diode-pumped, frequency-doubled Nd:YAG laser. Narrow-band, single-frequency operation is provided by injection seeding with a single-frequency, cw-diode-pumped diode laser. The main laser cavity is maintained in resonance with the seed laser by adjusting the cavity length to minimize the time between the Q-switch trigger and the emission of the laser pulse. The emission wavelength is tuned via temperature control of the seed laser crystal and is locked to line #1109 of the iodine absorption spectra. Locking is accomplished by minimizing the transmission through a 2-cm-long iodine absorption cell. Use of a high-repetition-rate laser and expansion of the transmitted beam through a 400-mm telescope reduces the transmitted energy density to eye-safe levels. It is possible to look directly into the output beam without hazard. The receiver and transmitter use the same afocal telescope, simplifying the maintenance of stable alignment of the transmitter and receiver although the angular FOV is only 100 μrad. The small FOV and the 4-kHz repetition rate also limit the near-field signal strength, making it possible to record continuous profiles that start at an altitude of ~100 m and extend to 30 km using photon counting detectors. The small FOV also suppresses multiple scattering contributions.

54 ENVIRONMENTAL SCIENCES↗

Technical Report on Waveform Fit Metrics for Global Models

The new WAVEFORMS Initiative in the Ground-based Nuclear Detonation Detection (GNDD) program includes an increased emphasis on the development of Earth models and methods to predict entire seismic and acoustic waveforms more accurately. In general, this increased emphasis is predicated on the need to better characterize seismic events and provide improved model-based discrimination between event types including earthquakes and explosions. More specifically, while current moment tensor inversion methods tend to work well for larger events (M>~4) using tuned 1-D Earth models, the development of state-of-the-art 3-D models and methods is required for the prediction of shorter period waves over large areas for discrimination of smaller events. There is no standard metric for model-based waveform prediction accuracy used in the waveform modeling/inversion community. However, there are several popular waveform misfit definitions; and minimizing the corresponding objective functions is the goal of waveform inversion. Some example misfit definitions employed for adjoint waveform tomography include measures of simple travel time differences (e.g. Tape et al., 2010), cross-correlation travel time differences (e.g. Luo and Schuster, 1991), multi-taper frequency dependent methods (e.g. Lei et al., 2020), time-frequency phase misfit functions (e.g. Fichtner 2010; Rodgers et al., 2022), normalized cross-correlation methods (e.g. Tao et al., 2018), and others. In some cases, these misfit definitions also involve complicated weighting schemes and summations over multiple frequency bands making it difficult to duplicate the misfit measurement with alternative models and datasets. Although each of the misfit definitions mentioned above are useful for developing waveform models, the actual misfit values are not usually meaningful outside of a given project, model, and/or dataset. Therefore, it is difficult to understand and communicate model performance for predicting waveforms and comparing to other models and/or new model iterations with a different dataset. Therefore, there is a need for a generalized method for evaluating overall model performance that is independent from the specific misfit chosen to develop the waveform models that is also intuitive and meaningful. In this report, we describe a new metric we refer to as ‘Percent of Correlated Signal’. The following sections describe and demonstrate the metric with a case study event and a more rigorous test using a random selection of globally distributed events. While the focus here is on global tomography models, the metric is meant to applicable to regional ‘wiggle-for-wiggle’ waveform models/studies as well.

58 GEOSCIENCES↗

Exploring the Effects of Emplacement Conditions on Explosion P/S Ratios across Local to Regional Distances

High-frequency (~> 2 Hz) seismic P/S amplitude ratios are well-established as a discriminant to distinguish between natural earthquakes and underground explosions at regional distances (~200–1500 km). As research shifts toward identifying lower-yield events, work has begun to investigate the potential of this discriminant for use at local distances (<200 km), in which initial results raise questions about its effectiveness. Here, we utilize data from several chemical explosion experiment series at the Nevada National Security Site in southern Nevada in the United States to study explosion Pg/Lg ratios across the range of local to regional distances. Additionall, the experiments are conducted over differing emplacement conditions, with contrasting geologies and a variety of yields and depths of burial, including surface explosions. We first establish the similarities of Pg/Lg ratios from chemical explosions to those from historic nuclear tests and conclude that, as previous data have suggested, chemical explosion ratios are good proxies for nuclear tests. We then examine Pg/Lg ratios from the new experiment series as functions of distance, yield, depth of burial, and scaled depth of burial (SDOB). At far-local and regional distances, we observe consistently higher ratios from hard-rock explosions compared to ones in a weaker dry alluvium medium, consistent with prior regional distance results. No other trends with yield, depth of burial, or SDOB are strongly evident. Scatter in the observed ratios is very high, particularly at the shortest event-to-station distances, suggesting that small-scale path effects play a significant role. On average, the local distance explosion Pg/Lg ratios show remarkable consistency across all the variations in emplacement. Explosion source models will need to reproduce these results.

58 GEOSCIENCES↗