ToF-SIMS Investigation of the Effectiveness of Acid-Cleaning procedures for Genesis Solar Wind Collectors

ToF-SIMS images of Genesis sample surfaces contain an incredible amount of important information, but they also show that the crash-derived surface contamination has many components, presenting a challenge to cleaning. Within the variability, we have shown that there are some samples which appear to be clean to begin with, e.g. 60471, and some are more contaminated. Samples 60493 and 60500 are a part of a focused study of the effectiveness of aqua regia and/or sulfuric acid cleaning of small flight Si implanted with Li-6 using ToF-SIMS.

Goreva, Y. S.↗

SIM Lite Detection of Habitable Planets in P-Type Binary-Planetary Systems

Close binary stars like spectroscopic binaries create a completely different environment than single stars for the evolution of a protoplanetary disk. Dynamical interactions between one star and protoplanets in such systems provide more challenges for theorists to model giant planet migration and formation of multiple planets. For habitable planets the majority of host stars are in binary star systems. So far only a small amount of Jupiter-size planets have been discovered in binary stars, whose minimum separations are 20 AU and the median value is about 1000 AU (because of difficulties in radial velocity measurements). The SIM Lite mission, a space-based astrometric observatory, has a unique capability to detect habitable planets in binary star systems. This work analyzed responses of the optical system to the field stop for companion stars and demonstrated that SIM Lite can observe exoplanets in visual binaries with small angular separations. In particular we investigated the issues for the search for terrestrial planets in P-type binary-planetary systems, where the planets move around both stars in a relatively distant orbit.

Pan, Xiaopei↗

SIM Interferometer Testbed (SCDU) Status and Recent Results

SIM Lite is a space-borne stellar interferometer capable of searching for Earth-size planets in the habitable zones of nearby stars. This search will require measurement of astrometric angles with sub micro-arcsecond accuracy and optical pathlength differences to 1 picometer by the end of the five-year mission. One of the most significant technical risks in achieving this level of accuracy is from systematic errors that arise from spectral differences between candidate stars and nearby reference stars. The Spectral Calibration Development Unit (SCDU), in operation since 2007, has been used to explore this effect and demonstrate performance meeting SIM goals. In this paper we present the status of this testbed and recent results.

Dispersion↗

Mitigation of Angle Tracking Errors Due to Color Dependent Centroid Shifts in SIM-Lite

The SIM-Lite astrometric interferometer will search for Earth-size planets in the habitable zones of nearby stars. In this search the interferometer will monitor the astrometric position of candidate stars relative to nearby reference stars over the course of a 5 year mission. The elemental measurement is the angle between a target star and a reference star. This is a two-step process, in which the interferometer will each time need to use its controllable optics to align the starlight in the two arms with each other and with the metrology beams. The sensor for this alignment is an angle tracking CCD camera. Various constraints in the design of the camera subject it to systematic alignment errors when observing a star of one spectrum compared with a start of a different spectrum. This effect is called a Color Dependent Centroid Shift (CDCS) and has been studied extensively with SIM-Lite's SCDU testbed. Here we describe results from the simulation and testing of this error in the SCDU testbed, as well as effective ways that it can be reduced to acceptable levels.

Spectral↗

A Multi-Sims Investigation of Water Content and D/H Ratios in Roberts Massif 04262 with Insight to Sources of Hydrogen in Maskelynite

We want to define the H2O content ([H2O]) and hydrogen (H) isotope composition of meteoritic material from Mars [1-3] with motivation to understand Mars’ volatile history, constrain geochemical signatures of interior water reservoirs (i.e. the Martian mantle) and explore effects of planetary (e.g. planet formation, magma ocean degassing) and local (e.g. volcanic degassing, impact melting and degassing) processes on H incorporated in minerals. Secondary ion mass spectrometry (SIMS) allows multiple avenues to address these questions. However, application to (1) precious astromaterials and (2) low level H measurements, pose specific challenges that are further complicated when combined. We present preliminary data of a multi-approach (SIMS vs. NanoSIMS) study of H in Roberts Massif 04262 (RBT 04262), an enriched lherzolitic shergottite with nonpoikilitic (NP) and poikilitic (P) lithologies [4]. We analyze olivine, pyrox-ene, and melt inclusions to compare indigenous mantle water, with impact-generated maskelynite to investigate H signatures due to shock.

Dudley, J. M.↗

SIM white light on-board processing algorithms

Interferometry in optical astronomy is an important and growing field of astronomical observation. A number of stellar interferometers have come online over the past several years, and several more are due to be operational in the near future. In addition, space based interferometers are also planned missions of NASA's Origins program, including the Space Interferometry Mission (SIM), the focus of the present paper. The fundamental measurement made by each of these interferometers is the white light fringe measurement to determine the optical pathlength delay between the two arms of the interferometer. SIM makes white light measurements with three independent interferometers observing three different objects. Two of these are the "guide" interferometers that observe bright objects (approximately 7th magnitude) to track the rigid body motion of the instrument. The third interferometer, the "science" interferometer, observes the science targets of interest.

interferometry↗

Precision linear actuator for Space Interferometry Mission (SIM) Siderostat pointing

“SIM PlanetQuest will exploit the classical measuring tool of astrometry (interferometry) with unprecedented precision to make dramatic advances in many areas of astronomy and astrophysics.” (1) In order to obtain interferometric data two large steerable mirrors, or Siderostats, are used to direct starlight into the interferometer. A gimbaled mechanism actuated by linear actuators is chosen to meet the unprecedented pointing and angle tracking requirements of SIM.

Moore, Don↗

Boundary and Initial Condition Issues for Computational Fluid Dynamics (CFD) and Modeling and Simulation (Mod-Sim)

For many important classes of Mod-Sim problems, even quantum computing will not enable accurate predictions/computation vis-à-vis the real world due to boundary/initial condition shortfalls in terms of both range of parameters and requisite amplitudes/coverage. The Mod-Sim community needs to consider going forward the knowability of initial and boundary conditions.

Dennis M. Bushnell↗

Solar Temperature Variations Computed from SORCE SIM Irradiances Observed During 2003-2020

NASA’s Solar Radiation and Climate Experiment (SORCE) Spectral Irradiance Monitor (SIM) instrument produced about 17 years of daily average Spectral Solar Irradiance ( SSI ) data for wavelengths 240 nm – 2416 nm. We choose a day of minimal solar activity, 2008-08-24, during the 2008 − 2009 minimum between cycles 23 and 24, and compute the brightness temperature (𝑇 o ) from that day’s solar spectral irradiance (𝑆𝑆𝐼 o ). We consider small variations of T and SSI about these reference values, and derive linear and quadratic analytic approximations by Taylor expansion about the reference day values. To determine approximation accuracy, we compare to exact brightness temperatures T computed from the Planck spectrum, by solving analytically for T , or equivalent root-finding in Wolfram Mathematica. We find that the linear analytic approximation overestimates, while the quadratic underestimates the exact result. This motivates search for statistical “fit” models “in between” the two analytic models, with minimum root-mean-square-error RMSE. We make this search using open-source statistical R software, determine coefficients for linear and quadratic fit models, and compare statistical with analytic RMSE’s. When only linear analytic and fit models are compared, the fit model is superior at ultraviolet, visible, and near infrared wavelengths. This again holds true when comparing only quadratic models. Quadratic is superior to linear for both analytic and statistical models, and statistical fits give smallest RMSE’s. Lastly, we use linear analytic and fit models to find an interpolating function in wavelength, useful in case the SIM results need adjustment to another choices of wavelengths, to compare or extend to any other instrument.

SORCE↗

Combination of ToF-SIMS imaging and AFM to study the early stages of corrosion in Al-Cu thin films

The pitting corrosion of Al-Cu thin film alloys was investigated using samples that were heat treated in air to form through-thickness Al2Cu particles within an Al-0.5%Cu matrix. Time-of-Flight SIMS (ToF-SIMS) analysis revealed Cu-rich regions 250 - 800 nm in lateral extent near the metal/oxide interface. Following exposure that generated pitting corrosion, secondary electron, secondary ion, and AFM images showed pits with size and density similar to those of the Cu-rich regions. The role of the Cu-rich regions is addressed.

36 MATERIALS SCIENCE↗

SIMS and TEM Analysis of Niobium Bicrystals

The behaviour of interstitial impurities(C,O,N,H) on the Nb surface with respect to grain boundaries may affect cavity performance. Large grain Nb makes possible the selection of bicrystal samples with a well defined grain boundary. In this work, Dynamic SIMS was used to analyze two Nb bicrystal samples, one of them heat treated and the other non heat treated (control). H levels were found to be higher for the non heat treated sample and a difference in the H intensity and sputtering rate was also observed across the grain boundary for both the samples. TEM results showed that the bicrystal interface showed no discontinuity and the oxide layer was uniform across the grain boundary for both the samples. TOF-SIMS imaging was also performed to analyze the distribution of the impurities across the grain boundary in both the samples. C was observed to be segregated along the grain boundary for the control sample, while H and O showed a difference in signal intensity across the grain boundary. Crystal orientation appears to have an important role in the observed sputtering rate and impurity ion signal differences both across the grain boundary and between samples

36 MATERIALS SCIENCE↗

\texttt{qec\_code\_sim}: An open-source Python framework for estimating the effectiveness of quantum-error correcting codes on superconducting qubits

Quantum computers are highly susceptible to errors due to unintended interactions with their environment. It is crucial to correct these errors without gaining information about the quantum state, which would result in its destruction through back-action. Quantum Error Correction (QEC) provides information about occurred errors without compromising the quantum state of the system. However, the implementation of QEC has proven to be challenging due to the current performance levels of qubits -- break-even requires fabrication and operation quality that is beyond the state-of-the-art. Understanding how qubit performance factors into the success of a QEC code is a valuable exercise for tracking progress towards fault-tolerant quantum computing. Here we present \texttt{qec\_code\_sim}, an open-source, lightweight Python framework for studying the performance of small quantum error correcting codes under the influence of a realistic error model appropriate for superconducting transmon qubits, with the goal of enabling useful hardware studies and experiments. \texttt{qec\_code\_sim} requires minimal software dependencies and prioritizes ease of use, ease of change, and pedagogy over execution speed. As such, it is a tool well-suited to small teams studying systems on the order of one dozen qubits.

Lopez, Santiago↗

Influence of Bulk Chemical Composition on Relative Sensitivity Factors for 55Mn/52Cr by SIMS: Implications for the 53Mn-53Cr Chronometer

The {sup 53}Mn-{sup 53}Cr systematics of meteorite samples provide an important high resolution chronometer for early solar system events. Accurate determination of the initial abundance of {sup 53}Mn ({tau}{sub 1/2} = 3.7 Ma) by secondary ion mass spectrometry (SIMS) is dependent on properly correcting for differing ion yields between Mn and Cr by use of a relative sensitivity factor (RSF). Ideal standards for SIMS analysis should be compositionally and structurally similar to the sample of interest. However, previously published Mn-Cr studies rely on few standards (e.g., San Carlos olivine, NIST 610 glass) despite significant variations in chemical composition. We investigate a potential correlation between RSF and bulk chemical composition by determining RSFs for {sup 55}Mn/{sup 52}Cr in 11 silicate glass and mineral standards (San Carlos olivine, Mainz glasses KL2-G, ML3B-G, StHs6/80-G, GOR128-G, BM90/21-G, and T1-G, NIST 610 glass, and three LLNL pyroxene-composition glasses). All standards were measured on the Cameca ims-3f ion microprobe at LLNL, and a subset were also measured on the Cameca ims-1270 ion microprobe at the Geological Survey of Japan. The standards cover a range of bulk chemical compositions with SiO{sub 2} contents of 40-71 wt.%, FeO contents of 0.05-20 wt.% and Mn/Cr ratios between 0.4 and 58. We obtained RSF values ranging from 0.83 to 1.15. The data obtained on the ims-1270 ion microprobe are within {approx}10% of the RSF values obtained on the ims-3f ion microprobe, and the RSF determined for San Carlos olivine (0.86) is in good agreement with previously published data. The typical approach to calculating an RSF from multiple standard measurements involves making a linear fit to measured {sup 55}Mn/{sup 52}Cr versus true {sup 55}Mn/{sup 52}Cr. This approach may be satisfactory for materials of similar composition, but fails when compositions vary significantly. This is best illustrated by the {approx}30% change in RSF we see between glasses with similar Mn/Cr ratios but variable Fe and Na content. We are developing an approach that uses multivariate analysis to evaluate the importance of different chemical components in controlling the RSF and predict the RSF of unknowns when standards of appropriate composition are not available. Our analysis suggests that Fe, Si, and Na are key compositional factors in these silicate standards. The RSF is positively correlated with Fe and Si and negatively correlated with Na. Work is currently underway to extend this analysis to a wider range of chemical compositions and to evaluate the variability of RSF on measurements obtained by NanoSIMS.

58 GEOSCIENCES↗

In Situ Oxygen Isotope Determination in Serpentine Minerals by SIMS: Addressing Matrix Effects and Providing New Insights on Serpentinisation at Hole BA1B (Samail ophiolite, Oman)

The ability to constrain the petrogenesis of multiple serpentine generations recorded at the microscale is crucial for estimating the extent and conditions of modern versus fossil serpentinisation in ophiolites. To address matrix bias effects during oxygen isotope analysis by SIMS, we present the first investigation analysing antigorite in the compositional range Mg# = 77.5–99.5 mole %, using a CAMECA IMS–1280 secondary ion mass spectrometer. Spot–to–spot homogeneity is ≤ 0.5‰ (2s) for the new antigorite reference materials. The relative bias between antigorite reference materials with different Mg/Fe ratios is described by a second order polynomial, and a maximum difference in bias of ~ 1.8‰ was measured for Mg# ~ 78 to 100. We observed a bias up to ~ 1.0‰ between lizardite and antigorite attributed to their different crystal structure. Orientation effects up to ~ 1‰ were observed in chrysotile. The new analytical protocol allowed the identification of oxygen isotope zoning up to ~ 7‰ in serpentine minerals from two serpentinites recovered from an area of active serpentinisation in the Samail ophiolite. Furthermore in situ analysis is capable of resolving isotopic heterogeneity that may directly reflect changes in the physical and chemical conditions of multiple serpentinisation events in the Samail ophiolite.

47 OTHER INSTRUMENTATION↗

The SIM astronmetric grid

The Space Interferometry Mission (SIM) is fundamentally a one-dimensional instrument with a 15-degree field-of-regard. Mission objectives require a global reference grid of thousands of well-understood stars with positions known to 4 microarcseconds which will be used to establish the instrument baseline vector during scientific observations. This accuracy will be achieved by frequently observing a set of stars throughout the mission and performing a global fit of the observations to determine position, proper motion and parallax for each star. Each star will be observed approximately 200 times with about 6.5 stars per single instrument field on the sky. We describe the nature of the reference grid, the candidate objects, and the results of simulations demonstrating grid performance, including estimates of the grid robustness when including effects such as instrument drift and possible contamination of the grid star sample by undetected binaries.

SIM grid astrometry Space Interferometry Mission S↗

SIM Test-bed 3 real-time control software

This paper describes the design of interacting software control loops and how they work together to accomplish SIM System Testbed 3 objectives.

SIM SIM System Testbed 3 STB3 real-time avalanche ↗

ToF-SIMS Depth Profiling Of Insulating Samples, Interlaced Mode Or Non-interlaced Mode?

Dual beam depth profiling strategy has been widely adopted in ToF-SIMS depth profiling, in which two basic operation modes, interlaced mode and non-interlaced mode, are commonly used. Generally, interlaced mode is recommended for conductive or semi-conductive samples, whereas non-interlaced mode is recommended for insulating samples, where charge compensation can be an issue. Recent publications, however, show that the interlaced mode can be used effectively for glass depth profiling, despite the fact that glass is an insulator. In this study, we provide a simple guide for choosing between interlaced mode and non-interlaced mode for insulator depth profiling. Two representative cases are presented: (1) depth profiling of a leached glass sample, and (2) depth profiling of a single crystal MgO sample. In brief, the interlaced mode should be attempted first, because (1) it may provide reasonable-quality data, and (2) it is time-saving for most cases, and (3) it introduces low H/C/O background. If data quality is the top priority and measurement time is flexible, non-interlaced mode is recommended because interlaced mode may suffer from low signal intensity and poor mass resolution. A big challenge is tracking trace H/C/O in a highly insulating sample (e.g., MgO), because non-interlaced mode may introduce strong H/C/O background but interlaced mode may suffer from low signal intensity. Meanwhile, a C or Au coating is found to be very effective to improve the signal intensity. Surprisingly, the best analyzing location is not on the C or Au coating, but at the edge (outside) of the coating.

Environmental Molecular Sciences Laboratory↗