Search NASA⌕ Search

SEARCH · Search NASA

Results for “SODIUM COOLING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Steam Generators: Thermal Hydraulic Measurements and Instrumentation

Steam generators are integral components of both conventional and advanced reactors utilizing steam power cycles, as they influence the power conversion performance. Steam generator designs are highly influenced by the type of reactor coolant used, which mainly governs the different control, monitoring, and safety system actuation requirements. Therefore, the present work reviews the thermal hydraulics instrumentation within steam generators designed for pressurized water reactors (PWRs), high-temperature gas-cooled reactors (HTGRs), sodium fast reactors (SFRs), and molten salt cooled reactors (MSRs). Emphasis is given to measurement techniques that are either unique or particularly important to specific reactor types. Lastly, a discussion is provided on the instrumentation and measured parameters. The work identifies standard parameters of interest and is expected to aid the development of test beds and novel measurements techniques.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Survey and Assessment of Computational Capabilities for Advanced (Non-LWR) Reactor Mechanistic Source Term Analysis.

A vital part of the licensing process for advanced (non-LWR) nuclear reactor developers in the United States is the assessment of the reactor’s source term, i.e., the potential release of radionuclides from the reactor system to the environment during normal operations and accident sequences. In comparison to source term assessments which follow a bounding approach with conservative assumptions, a mechanistic approach to modeling radionuclide transport, which realistically accounts for transport and retention phenomena, is expected to be used for advanced reactor systems. As the designs of advanced reactors increase in maturity and progress towards licensing, there is a need to advance modeling and simulation capabilities in analyzing the mechanistic source term (MST) of a prospective reactor concept. In the present work, a survey is provided of existing computational capabilities for the modeling of advanced reactors MSTs. The following reactors are considered: high temperature gas reactors (HTGR); molten salt reactors (MSR) which include salt-fueled reactors and fluoride salt-cooled high temperature reactors (FHR); and sodium- and lead-cooled fast reactors (SFR, LFR). A review of relevant codes which may be useful in providing information to MST analyses is also completed, including codes that have been used for source term analyses of LWRs, as well as those being developed for other aspects of advanced reactor system modeling such as reactor physics, thermal hydraulics, and chemistry. A discussion of MST modeling capabilities for each reactor type is provided with additional focus on important phenomena and functional requirements. Additionally, a comprehensive survey is provided of tools for consequence modeling such as atmospheric transport and dispersion (ATD).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Laser refrigeration of optically levitated sodium yttrium fluoride nanocrystals

Solid state laser refrigeration can cool optically levitated nanocrystals in an optical dipole trap, allowing for internal temperature control by mitigating photothermal heating. This work demonstrates cooling of ytterbium-doped cubic sodium yttrium fluoride nanocrystals to 252 K on average with the most effective crystal cooling to 241 K. The amount of cooling increases linearly with the intensity of the cooling laser and is dependent on the pressure of the gas surrounding the nanocrystal. Furthermore, cooling optically levitated nanocrystals allows for crystals prone to heating to be studied at lower pressures than currently achievable and for temperature control and stabilization of trapped nanocrystals

36 MATERIALS SCIENCE↗

The Use of Long-wave Infrared Cameras for Hazardous Waste Remediation - 20457

For over fifty years, infrared cameras have been used in military applications, nondestructive testing, condition monitoring, and predictive maintenance. As infrared cameras continue to become more sophisticated and less expensive, they are providing value in an ever-increasing variety of unique applications, including hazardous waste remediation. This paper describes several instances of how infrared cameras have been used within the US Department of Defense and the US Department of Energy in support of waste remediation projects, including the author's recent use of an infrared camera in support of the Calcine Retrieval Project at the Idaho National Laboratory. Infrared cameras provide images of infrared radiation, or heat energy, which is otherwise invisible to the unaided eye. Infrared radiation is part of the electromagnetic spectrum, which includes visible light. But unlike visible light, infrared has wavelengths longer than the human eye can detect. Infrared is emitted by everything with a temperature above absolute zero (-273 deg. C, or -459 deg. F); the higher the temperature, the greater the infrared thermal radiation, or heat, that is emitted. Even objects that feel cold to us, like ice, emit thermal radiation and can be imaged by infrared cameras. These cameras are typically used to look for abnormally hot or cold spots on a component or target area under normal operating conditions. The method provides a rapid, wide-area, noncontact technique for identifying problems associated with a temperature differential. All infrared cameras can provide qualitative thermal information by displaying relative differences in temperatures within a two-dimensional image. More expensive infrared cameras can also provide quantitative information where an absolute temperature value is assigned to each pixel associated with the displayed two-dimensional image. Proper camera calibration and a solid understanding of heat transfer and thermography techniques are required when using an infrared camera to obtain quantitative information. Case studies outlined in this paper include the rapid, non-intrusive detection of hazardous decontamination solution within one-ton shipping containers at Pine Bluff Arsenal, the non-intrusive identification of residual elemental sodium within the cooling loops of the Experimental Breeder Reactor II (EBR-II) reactor at the Idaho National Laboratory, process monitoring of heat exchanger melt-and-drain efforts during EBR-II decommissioning, and the remote detection of internal steel supports within calcine storage bins prior to bin penetration. For each use of thermography, the author describes a summary of the waste remediation effort, the infrared camera used, the thermal imaging technique employed, and the results obtained. The paper concludes with a discussion on common mistakes to avoid for similar applications of thermography. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advanced Reactor Supply Chain Assessment (GAIN Report)

Several net-zero scenario evaluations predict a rapid ramp up of nuclear energy in the coming decades. If this materializes, it will most likely strain the supply chains associated with the potential advanced reactor concepts awaiting deployment. To help assess the current and potential capacities of the various advanced reactor supply chains, the Gateway for Accelerated Innovation in Nuclear (GAIN) conducted a survey of companies able to produce components for advanced reactors in the near future (namely for sodium, gas-cooled, and molten salt reactors). Using an aggressive nuclear deployment scenario, the objective was to assess the ability of the various supply chains to meet the considerable demand projections for certain key components (vessels, heat exchangers, pumps, graphite, and sensors) and identify potential challenges. While individual companies were unable to meet the most optimistic nuclear deployment rate projections, it was found that on aggregate, a United States-based supply chain projected that expansion could be ramped up to meet a larger future demand of these components. However, meeting projected demand for several more complex items (namely gas or salt heat exchangers) was found to be more challenging. Deploying new reactors at scale necessitates the production of more and more supply chain components, requiring a ramp up in production. Supply chain companies were surveyed, and respondents appeared less able to meet short term demand (next year) versus longer-term demand projections (5 and 10 years). This reflects the need to obtain orders with adequate lead times (can range from 3 to 30 months). Future demand will need to be met by expanding existing capacity. These expansions will require suppliers to raise capital or secure other types of support (federal loans or grants) to invest in facilities, equipment, and workforce. Individual suppliers indicated financial investments could be in the range of $\$ $100 million to $\$ $1 billion for their own facilities (depending on the type of facility). The biggest risk, according to respondents, related to general uncertainties surrounding the future nuclear industry and whether the potential demand projections will materialize into real demand that is actionable from a business perspective. Businesses do not seem willing to take investments risks without clear orders. If businesses are not able to invest to expand the supply, it will either delay the deployment of advanced nuclear technology, or the supply chain will be met by suppliers outside of the United States. This report only focuses on the domestic supply chain’s ability to meet the various projections stipulated here for the specific assessed components (vessels, heat exchangers, pumps, graphite, and sensors). The report does not cover all reactor designs or all components that may ultimately be needed for any one reactor design. It also does not address whether any specific aspect of the supply chain will be cost competitive in the global market, nor how potential state-backed entities could affect the expansion of a United States-based supply chain. The largest challenges in ramping up capacity among respondents appear to be workforce related. This includes workforce availability, experience, training, and turnover. In addition to facility investment, suppliers will also need to invest heavily in long-term workforce training to meet production goals. This issue is not nuclear-specific, and the expansion of any supply chain will likely face similar challenges. While suppliers evaluated expected normal business demand from other markets outside of nuclear, it is possible that other market segments could expand more than predicted and compete for the same suppliers. One potential market that may compete for the same supplier resources is the United States military, as many of these suppliers support both the commercial nuclear sector as well as the Navy with reactors and components. In summary, suppliers in the United States believe that there is a way to increase production in order to begin meeting the demand which will exist for advanced reactors—as long as appropriate investments can be made in the supply chain in an appropriate timeframe. Based on the capacity projections and lead times, investment will be needed to meet the 5-year and 10-year production targets. Therefore, if significant nuclear deployment is to occur in the 2030s, investment and ramp up of the advanced nuclear supply chain will need to begin in the near future for the United States to successfully deploy these advanced reactors with domestic supply chains.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SPC-2918 Rev 0 MARVEL Test Loop Flowmeters

This specification contains the requirements for the design, manufacture, testing, and delivery of magnetic flowmeters to be installed on the MARVEL Primary Coolant Apparatus Test (PCAT) system. The PCAT system is a heated test loop which will be used to simulate the coolant system of a proposed sodium or NaK cooled microreactor. The system has four identical cooling loops. Installation of flowmeters on all four loops is anticipated at this time, however, the number of flowmeters may be reduced by the Project. Note that the number of flowmeters described herein is not a commitment to a particular number of procured units. The number of flowmeter units procured shall be identified on the purchase order. The MARVEL reactor is still under design, so the PCAT flowmeter design may not be directly transferrable to the reactor. It is intended that the design and development effort for the PCAT flowmeters be leveraged to the extent practical for the reactor flowmeter design.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Design of Microwave Resonant Cavity Transducer. Development of sensor performance model of microwave cavity flow meter for advanced reactor high temperature fluids

High-temperature fluid reactors, such as molten salt cooled reactors (MSCR) and sodium fast reactors (SFR), are a promising advanced reactor option. Measurement of high-temperature fluid process variables, in particular the flow inside the pressure vessel, is a challenging task because of harsh environment, which includes high radiation, high temperature, and contact with highly corrosive coolant fluid. We are investigating a microwave cavity-based transducer for high-temperature fluid flow sensing. This sensor is a hollow metallic cylindrical cavity, which can be fabricated from stainless steel, and as such is expected to be resilient to radiation, high temperature and corrosive environment of MSCR and SFR. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. A cavity is characterized by its resonant frequencies. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. Feasibility of the flow sensor is evaluated with signal sensitivity using COMSOL computer simulations. A right cylinder geometry stainless steel cavity with dimeter of 0.8in was investigated. We choose membrane thickness of 10mil, so that corrosion anticipated to proceed at the rate of 1mil/year in liquid sodium would affect no more than 10% of the membrane. Using the properties of liquid sodium fluid, and stainless-steel material property values at 500oC, we calculate frequency shift for a range of values of fluid velocity from 0.5m/s to 2m/s. Results of computer simulations indicate measurable sensitivity to flow for this cavity design. Following these simulations, we have developed a preliminary design for fabrication of a transducer operating in microwave K-band for proof-of-principle tests.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fabrication and Preliminary Demonstration of Microwave Resonant Cavity Transducer Performance

We are investigating a microwave cavity-based transducer for in-core high-temperature fluid flow sensing in molten salt cooled reactors (MSCR) and sodium fast reactors (SFR). This sensor is a hollow metallic cylindrical cavity, which can be fabricated from stainless steel, and as such is expected to be resilient to radiation, high temperature and corrosive environment of MSCR and SFR. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. We have developed an initial design for proof-of-principle testing of the flow sensor performance in microwave K-band. A cylindrical resonator prototype was fabricated from brass for initial tests in water. The cavity size is matched to the flange of a standard WR-42 waveguide. Microwave field is coupled into the resonant cavity through a subwavelength-size aperture. A test article was developed, consisting of a piping Tee with bulkhead WR-42 microwave waveguide installed in leak-proof design. In the test article, the cylindrical cavity is positioned in the center of the pipe. A microwave waveguide circulator was installed in the setup to suppress microwave reflections at the cavity entrance. Preliminary spectral characterization of cavity spectral response was performed with microwave VNA. Applying mechanical pressure to cavity membrane showed a measurable shift in the microwave resonant frequency. We also investigate mechanical integrity of the flowmeter’s membrane through computer simulations. By calculating the stress on the plate due to deflection and, comparing the stress to the material ultimate tensile strength and yield strength, it can be estimated if the plate will fail. The stress on the plate was calculated with an analytic closed form solution model, and with COMSOL Structural Mechanics Module which does not involve any approximations. Both the analytic model and COMSOL model showed that maximum stresses on the plate, which are at the radial boundary of the plate, are three orders of magnitude smaller than the yield strength and ultimate tensile strength. This indicates that the sensor is at a low risk of mechanical failure.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

First Annual Report on Development of Microwave Resonant Cavity Transducer for Fluid Flow Sensing: Development of Sensor Performance Model of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave cavity-based transducer for in-core high-temperature fluid flow sensing in molten salt cooled reactors (MSCR) and sodium fast reactors (SFR). This sensor is a hollow metallic cylindrical cavity, which can be fabricated from stainless steel, and as such is expected to be resilient to radiation, high temperature and corrosive environment of MSCR and SFR. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. Feasibility of the sensor was initially investigated with analytical derivations and with COMSOL RF Module computer simulations of resonant frequency spectral shift due to uniform load. We also investigated the mechanical integrity of the flowmeter’s membrane through analytical modelling and COMSOL Structural Mechanics Module computer simulations. Both the analytic model and COMSOL model showed that maximum stresses on the plate, which are at the radial boundary of the plate, are three orders of magnitude smaller than the material’s yield strength and ultimate tensile strength. This indicates that the sensor is at a low risk of mechanical failure. Using results from models, we have developed an initial design for a microwave K-band sensor. A cylindrical resonator prototype was fabricated from brass for the initial tests. The external dimensions of the cavity are matched to the flange of a standard WR-42 waveguide. Microwave field is coupled into the resonant cavity through a subwavelength-size aperture. A test article was developed consisting of a piping Tee with a bulkhead WR-42 microwave waveguide installed in a leak-proof assembly. A microwave waveguide circulator was installed in the setup to suppress the effect of reflections at the cavity entrance by increasing the isolation between the input and the output port. Preliminary spectral characterization of cavity spectral response was performed with a portable PXIe chassis microwave VNA with a custom GUI. Preliminary dry tests of the transducer response were conducted with a set of calibrated weights. Transducer frequency shift was shown to be monotonically increasing with increasing pressure. The next steps will involve investigation of the transducer performance for water flow sensing.

42 ENGINEERING↗

Demonstration of Microwave Resonant Cavity Transducer Performance in Fluid Flow Sensing: Development of Sensor Performance Model of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave cavity-based transducer for in-core high-temperature fluid flow sensing in molten salt cooled reactors (MSCR) and sodium fast reactors (SFR). This sensor is a hollow metallic cylindrical cavity. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. To validate sensor physics, we have performed proof-of-principle test of flow sensing in water. For this test, we have developed a cylindrical resonator for K-band, which was machined from brass. The cavity was excited through WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder. To increase the spectral signal visibility, we developed a signal processing method for baseline subtraction. A flow loop for proof-of-principle test of transducer performance in water was assembled. A commercial flow meter was installed in the loop for reference measurements. Cylindrical cavity was excited in the TEM 011 mode with resonant frequency f ≈ 17.8GHz. Frequency shift of cavity spectral response was obtained by gradually increasing water flow rate from 0 to 60gpm. Corresponding monotonic increase of resonant frequency shift by several MHz was observed.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Assessment of Nuclear Data Needs for Advanced Reactor Demonstrations: Application to the Molten Chloride Reactor Experiment (MCRE)

A number of advanced reactor concepts are planned for near-term demonstrations including microreactors, larger demonstrations and space nuclear systems. These reactor concepts are based on a wide variety of reactor technologies, including sodium, gas, and salt cooling. An overlooked area in the development and ultimate startup of these reactors is addressing nuclear data needs that allow confident prediction of the criticality, safety requirements, and operation of the reactors. In this paper we try to address the problem of assessing nuclear data needs and possible remedies to reduce the existing uncertainties for advanced nuclear reactors. A methodology for defining these needs is described. The case of the Molten Chloride Reactor Experiment (MCRE) has been considered and the related investigation highlights the specific needs for reducing uncertainty on the 235U capture and 35Cl (n,p) reactions. Integral experiments relatively inexpensive are indicated as possible solution for significantly reduce the current associated uncertainties.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Assessment of nuclear data needs for advanced reactor demonstrations: application to the molten chloride reactor experiment (MCRE)

A number of advanced reactor concepts are planned for near-term demonstrations including micro-reactors, larger demonstrations and space nuclear systems. These reactor concepts are based on a wide variety of reactor technologies, including sodium, gas, and salt cooling. An overlooked area in the development and ultimate startup of these reactors is addressing nuclear data needs that allow confident prediction of the criticality, safety requirements, and operation of the reactors. In this paper we try to address the problem of assessing nuclear data needs and possible remedies to reduce the existing uncertainties for advanced nuclear reactors. A methodology for defining these needs is described. The case of the Molten Chloride Reactor Experiment (MCRE) has been considered and the related investigation highlights the specific needs for reducing uncertainty on the {sup 235}U capture and {sup 35}Cl (n,p) reactions. Relatively inexpensive integral experiments are indicated as possible solutions for significantly reducing the current associated uncertainties. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Miniature DC electromagnetic pumps of molten lead and sodium to support development of Gen-IV nuclear reactors

This work developed designs of submerged, dual-regions, miniature DC-EM pumps for circulating molten lead and liquid sodium at ≤500 °C without active cooling for use in ex-pile and in-pile test loops to support of materials and fuel developments for Gen-IV sodium and molten lead fast nuclear reactor. These pumps with two pumping regions are 57 mm, 66.8 mm, 95.4 mm, and 133.5 mm in diameter and have two Alnico 5 permanent magnets with Hiperco-50 pole pieces for focusing the magnetic field lines in the flow duct. The Equivalent Circuit Model (ECM) linked to the Finite Element Method Magnetics (FEMM) software in MATLAB platform calculated the pumps characteristics for a wide range of parameters. Also determined are the pumps dimensions for the highest cumulative pumping power and peak efficiency. These dimensions are the height, width, and length of the flow duct, the thickness of the Alnico magnets, the length of current electrodes, and the separation distance between the two pumping regions. For molten lead, the pumping power increases from 368 W to 728 W, and the peak efficiency from 14.7% to 31.6% with increased pump diameter from 57 mm to 133.5 mm. In conclusion, for liquid sodium, both the pumping power and peak efficiency are higher, increasing from 392 W to 767 W and from 44.3 to 51.2%, respectively, with increased pump diameter from 57 mm to 133.5 mm.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Improving to the neutron fluence rate monitor measurement system at the Advanced Test Reactor [Poster]

The existing fluence monitor wire scanning system at the Advanced Test Reactor (ATR) was designed and installed for use in the Engineering Test Reactor (ETR) when it began operation in 1958. The wire scanner was operated in ETR for over 20 years until ATR began operation, when it was moved to the ATR west canal area in 1971 and subsequently moved to the west canal in 2006 where it presently resides. With a continued service life of 65 years the system is well beyond the typical design life of 20 years for these types of systems. The need to update the data acquisition and control system was identified, and the benefits of replacing the existing sodium iodide (NaI) detector with an electronically cooled high-purity germanium (HPGe) detector are discussed. The wirescanner system in the ATR canal is utilized after every reactor cycle by the ATR Radiation Measurements Laboratory (RML) to assess the activation of cobalt and nickel dosimeter wires during the cycle. These wires become activated through exposure to thermal and fast neutrons respectively during the irradiation cycle and are highly radioactive upon shutdown. It is for this reason that the wirescanner is used in the ATR canal rather than transporting the dosimeters to another facility. A scoping study was performed to develop a base-line design to ensure that existing capabilities could be replaced with a new system. The new hardware will enable automated measuring of several flux monitor holders without necessitating the removal of the flux wires. In this way, flux wire measurements will be performed with minimal dose to the technicians and will not be limited by canal operations as is presently the case. The new control and acquisition software will be based on commercially available and supported systems that have a wide user-base to provide long-term stability. An electronically cooled HPGe detector will be used to provide high-resolution gamma-ray measurements, an improvement from the low-resolution sodium-iodide detector that is presently deployed. The electronic cooler eliminates the need for liquid nitrogen to cool the detector head. A new collimator has been designed to house the new detector and allow for sufficient counting rates.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Strength stability at high temperatures for additively manufactured alumina forming austenitic alloy

Several fast-spectrum nuclear reactors designed to generate high power (~450 MWe) rely on forced convection of media such as supercritical CO 2 , sodium, or liquid lead to cool the nuclear core, operating at temperatures up to 600 °C. Cost-effective, high-strength Fe-based alumina forming austenitic (AFA) alloys are a promising candidate for the fabrication of critical nuclear components. This study investigated laser powder bed fusion (LPBF) processing of an AFA alloy composition optimized for improved creep resistance. Electron microscopy revealed an elongated grain structure along the build direction with a fine sub-grain cellular structure decorated with (Cr,Fe,Nb) 23 C 6 carbide precipitates at the intercellular boundaries. Finally, at temperatures of 20–900 °C, the LPBF alloy's superior tensile properties compared to its arc-melted counterpart and other advanced steels (e.g., SS316) were attributed to the distribution of nano-sized carbide precipitates, whereas the high ductility was attributed to the LPBF alloy's elongated grain structure.

36 MATERIALS SCIENCE↗

Uniaxial compressive creep tests by spark plasma sintering of 70% theoretical density α -uranium and U-10Zr

Metallic fuels hold numerous advantages over conventional uranium dioxide fuels and are a key component of several liquid metal-cooled advanced reactor concepts including sodium fast reactors. These fuels undergo rapid swelling during early burnup; consequently, they spend most of their reactor lifetime in a porous state. The presence of this porosity alters many of the mechanical properties of the fuel including creep impacting fuel deformation during axial swelling. This work investigates the creep behavior of the porous fuel using a spark plasma sintering technique. Creep tests were performed for the first time on porous α-phase uranium and uranium with 10 wt. % zirconium (U-10Zr) samples. The samples of α-phase uranium and U-10Zr were fabricated from depleted uranium by spark plasma sintering and subjected to uniaxial compressive creep testing. Calculated stress exponents were found to be 2.6±1.6 and 5.7±1.4 for α-U and U-10Zr, respectively, and calculated activation energies were found to be 61.6±1.1kJ/mol for α-U. The creep data were also used to evaluate existing porosity inclusive in creep models.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analysis of Microwave Resonant Cavity Transducer Degradation Mechanisms

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with the flat wall of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the resonant frequency, which can be detected with a spectrum analyzer. Because the transducer is intended for immersion in a high temperature corrosive fluid, understanding of material degradation is crucial for estimation of transducer performance lifetime, and development of measurement interpretation algorithms. We conducted a preliminary computational investigation of relevant damage mechanisms of a stainless steel 316 cylindrical resonator in FLiBe salt. The two main damage mechanisms, creep and corrosion, were modeled using multiphysics COMSOL software. Degradation was modeled for a temperature range 500°C to 700°C. Coupling of the damage mechanisms was not considered. These models predict significant inelastic deformation at most temperatures due to creep, and qualitatively predict chromium depletion both along the liquid/solid interface and along the grain boundaries. An algorithmic approach for compensation of these degradation effects during fluid flow measurements will be developed in the future work.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Second Annual Report on Development of Microwave Resonant Cavity Transducer for Fluid Flow Sensing

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with the flat wall of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the resonant frequency, which can be detected with a spectrum analyzer. Because the transducer is intended for immersion in a high temperature corrosive fluid, understanding of material degradation is crucial for estimation of transducer performance lifetime, and development of measurement interpretation algorithms. We conducted a preliminary computational investigation of relevant damage mechanisms of a stainless steel 316 cylindrical resonator in FLiBe salt. The two main damage mechanisms, creep and corrosion, were modeled using multiphysics COMSOL software. Degradation was modeled for a temperature range 500°C to 700°C. Coupling of the damage mechanisms was not considered. These models predict significant inelastic deformation at most temperatures due to creep, and qualitatively predict chromium depletion both along the liquid/solid interface and along the grain boundaries. An algorithmic approach for compensation of these degradation effects during fluid flow measurements will be developed in the future work. To validate sensor physics, we have performed proof-of-principle test of flow sensing in water. For this test, we have developed a cylindrical resonator for K-band, which was machined from brass. The cavity was excited through WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder. To increase the spectral signal visibility, we developed a signal processing method for baseline subtraction. A flow loop for proof-of-principle test of transducer performance in water was assembled. A commercial flow meter was installed in the loop for reference measurements. Cylindrical cavity was excited in the TE 011 mode with resonant frequency f ≈ 17.8GHz. Frequency shift of cavity spectral response was obtained by gradually increasing water flow rate from 0 to 60gpm. Corresponding monotonic increase of resonant frequency shift by several MHz was observed. Approximate figure of merit of sensitivity to flow rate is 100KHz/GPM. In addition, we have identified an existing liquid sodium experimental setup for demonstration of flow sensing in environment similar to that of an advanced reactor. The setup consists of a cylindrical vessel and center feed line, where transducer inserted through the lid will measure velocity of the impinging liquid jet. As a calibration experiment, we have assembled a water vessel with center feed with the same dimensions as those of the liquid sodium setup. We have also developed and insertion probe consisting of a 50cm brass waveguide enclosed in protective SS316 tube. Using the water loop, we have demonstrated feasibility of sensing the impinging liquid jet in the vessel.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗