Search NASA⌕ Search

SEARCH · Search NASA

Results for “SPECTRAL BANDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Dual-Polarization, Multi-Frequency Antenna Array for use with Hurricane Imaging Radiometer

Advancements in common aperture antenna technology were employed to utilize its proprietary genetic algorithmbased modeling tools in an effort to develop, build, and test a dual-polarization array for Hurricane Imaging Radiometer (HIRAD) applications. Final program results demonstrate the ability to achieve a lightweight, thin, higher-gain aperture that covers the desired spectral band. NASA employs various passive microwave and millimeter-wave instruments, such as spectral radiometers, for a range of remote sensing applications, from measurements of the Earth's surface and atmosphere, to cosmic background emission. These instruments such as the HIRAD, SFMR (Stepped Frequency Microwave Radiometer), and LRR (Lightweight Rainfall Radiometer), provide unique data accumulation capabilities for observing sea surface wind, temperature, and rainfall, and significantly enhance the understanding and predictability of hurricane intensity. These microwave instruments require extremely efficient wideband or multiband antennas in order to conserve space on the airborne platform. In addition, the thickness and weight of the antenna arrays is of paramount importance in reducing platform drag, permitting greater time on station. Current sensors are often heavy, single- polarization, or limited in frequency coverage. The ideal wideband antenna will have reduced size, weight, and profile (a conformal construct) without sacrificing optimum performance. The technology applied to this new HIRAD array will allow NASA, NOAA, and other users to gather information related to hurricanes and other tropical storms more cost effectively without sacrificing sensor performance or the aircraft time on station. The results of the initial analysis and numerical design indicated strong potential for an antenna array that would satisfy all of the design requirements for a replacement HIRAD array. Multiple common aperture antenna methodologies were employed to achieve exceptional gain over the entire spectral frequency band while exhibiting superb VSWR (voltage standing wave ratio) values. Element size and spacing requirements were addressed for a direct replacement of the thicker, lower-performance, stack ed patch antenna array currently employed for the HIRAD application. Several variants to the multiband arrays were developed that exhibited four, equally spaced, high efficiency, "sweet spot" frequency bands, as well as the option for a high-performance wideband array. The 0.25-in. (≈6.4- mm) thickness of the antenna stack-up itself was achieved through the application of specialized antenna techniques and meta-materials to accomplish all design objectives.

Little, John↗

An infrared heterodyne radiometer for high-resolution measurements of solar radiation and atmospheric transmission

A tunable, Dicke-switched, infrared heterodyne radiometer (IHR) has been designed, fabricated, tested, and used to observe solar radiation and determine the atmospheric transmissivity in the 9-11-micron spectral band. The IHR provides a spectral resolution of 0.0067 reciprocal cm, a minimum detectable power level of 2.9 times ten to the minus twenty-third power W/Hz, and a temperature resolution of less than 1 K for a source temperature of 1000 K, an IF predetection bandwidth of 100 MHz, and an integration time of 30 s. Detailed design equations and measured IHR performance are presented. The IHR was used to make solar and atmospheric transmission measurements, and a vertical-path atmospheric attenuation of 2.3 dB has been established under favorable weather conditions. The attenuation of solar radiation due to cloud cover and haze has also been investigated.

Peyton, B. J.↗

Characterization of tropospheric desert aerosols at solar wavelengths by multispectral radiometry from Landsat

Characteristics of tropospheric desert aerosols are derived by comparing nadir spectral reflectivities computed from the radiative transfer models with reflectivities measured from Landsat. Over the ocean, reflectivities are compared, but over land the comparison is carried out by determining the ratios of the nadir reflectivity of the surface-atmosphere system over heavy aerosol concentration to the reflectivity of the underlying surface. This remote sensing technique is found to be a sensitive approach for measuring n sub 2, the imaginary part of the refractive index. The desert aerosols under study, in the Iran and Pakistan area, are essentially pure scatterers, inasmuch as an n sub 2 value of 0.001 + or - 0.001 was determined for each of the four Landsat spectral bands, that is, for a spectral interval from 0.5 to 1.1 microns.

Otterman, J.↗

An evaluation of simulated Thematic Mapper data and Landsat MSS data for discriminating suburban and regional land use and land cover

An airborne multispectral scanner, operating in the same spectral channels as the Landsat Thematic Mapper (TM), was used in a region east of Denver, CO, for a simulation test performed in the framework of using TM to discriminate the level I and level II classes. It is noted that at the 30-m spatial resolution of the Thematic Mapper Simulator (TMS) the overall discrimination for such classes as commercial/industrial land, rangeland, irrigated sod, irrigated alfalfa, and irrigated pasture was superior to that of the Landsat Multispectral Scanner, primarily due to four added spectral bands. For residential and other spectrally heterogeneous classes, however, the higher resolution of TMS resulted in increased variability within the class and a larger spectral overlap.

Toll, D. L.↗

Acousto-optic tunable filter (AOTF) imaging spectrometer for NASA applications - System issues

A recently developed AOTF operating in the visible, 0.4-0.8 micron bandpass is presently compared with other spectrometer designs, with a view to the advantages it may uniquely offer for prospective NASA missions. Since spectral identification is accomplished by this system through the scanning of a few spectral bands, data storage requirements for spectral image analysis can be significantly reduced. Attention is given to spectral and imaging capabilities and their applicability to defense, remote sensing, and industrial uses.

Yu, Jeffrey↗

Preliminary Assessment of Suomi-NPP VIIRS On-orbit Radiometric Performance

The Visible-Infrared Imaging Radiometer Suite (VIIRS) is a key instrument on-board the Suomi National Polar-orbiting Partnership (NPP) spacecraft that was launched on October 28th 2011. VIIRS was designed to provide moderate and imaging resolution of most of the globe twice daily. It is a wide-swath (3,040 km) cross-track scanning radiometer with spatial resolutions of 370.and 740 m at nadir for imaging and moderate bands, respectively. It has 22 spectral bands covering the spectrum between 0.412 11m and 12.01 11m, including 14 reflective solar bands (RSB), 7 thermal emissive bands (TEB), and 1 day-night band (ON B). VIIRS observations are used to generate 22 environmental data products (EORs). This paper will briefly describe NPP VIIRS calibration strategies performed by the independent government team, for the initial on-orbit Intensive Calibration and Validation (ICV) activities. In addition, this paper will provide an early assessment of the sensor on-orbit radiometric performance, such as the sensor signal to noise ratios (SNRs), dual gain transition verification, dynamic range and linearity, reflective bands calibration based on the solar diffuser (SO) and solar diffuser stability monitor (SOSM), and emissive bands calibration based on the on-board blackbody calibration (OBC). A comprehensive set of performance metrics generated during the pre-launch testing program will be compared to VIIRS on-orbit early performance, and a plan for future cal/val activities and performance enhancements will be presented.

Oudrari, Hassan↗

JPSS-1 VIIRS Radiometric Characterization and Calibration Based on Pre-Launch Testing

The Visible Infrared Imaging Radiometer Suite (VIIRS) on-board the first Joint Polar Satellite System (JPSS) completed its sensor level testing on December 2014. The JPSS-1 (J1) mission is scheduled to launch in December 2016, and will be very similar to the Suomi-National Polar-orbiting Partnership (SNPP) mission. VIIRS instrument has 22 spectral bands covering the spectrum between 0.4 and 12.6 m. It is a cross-track scanning radiometer capable of providing global measurements twice daily, through observations at two spatial resolutions, 375 m and 750 m at nadir for the imaging and moderate bands, respectively. This paper will briefly describe J1 VIIRS characterization and calibration performance and methodologies executed during the pre-launch testing phases by the government independent team to generate the at-launch baseline radiometric performance and the metrics needed to populate the sensor data record (SDR) Look-Up-Tables (LUTs). This paper will also provide an assessment of the sensor pre-launch radiometric performance, such as the sensor signal to noise ratios (SNRs), radiance dynamic range, reflective and emissive bands calibration performance, polarization sensitivity, spectral performance, response-vs-scan (RVS), and scattered light response. A set of performance metrics generated during the pre-launch testing program will be compared to both the VIIRS sensor specification and the SNPP VIIRS pre-launch performance.

VIIRS↗

An Overall Assessment of JPSS-2 VIIRS Radiometric Performance Based on Pre-Launch Testing

The Visible Infrared Imaging Radiometer Suite (VIIRS) on-board the second Joint Polar Satellite System (JPSS) completed its sensor level testing in February 2018. The JPSS-2 (J2) mission is scheduled to launch in 2022 and will be very similar to its two predecessor missions, the Suomi National Polar-orbiting Partnership (SNPP) mission, launched on 28 October 2011 and JPSS-1 (renamed NOAA-20) launched on 18 November 2017. VIIRS instrument has 22 spectral bands covering the spectrum between 0.4 and 12.6 μm: 14 reflective solar bands (RSB), 7 thermal emissive bands (TEB) and one day-night band (DNB). It is a cross-track scanning radiometer capable of providing global measurements through observations at two spatial resolutions, 375 m and 750 m at nadir for the imaging bands and moderate bands, respectively. This paper will provide an overview of J2 VIIRS characterization methodologies and calibration performance during the pre-launch testing phases performed by the National Aeronautics and Space Administration (NASA) VIIRS Characterization Support Team (VCST) to evaluate the at-launch baseline radiometric performance and generate the parameters needed to populate the sensor data record (SDR) Look-Up-Tables (LUTs). Our analysis results confirmed the good performance of J2 VIIRS, in general as good as previous VIIRS instruments and all non-compliances are expected to have low impact on data quality. Key sensor performance metrics include the signal to noise ratio (SNR), radiance dynamic range, reflective and emissive bands calibration performance, polarization sensitivity, spectral performance, response versus scan-angle (RVS) and scattered light response. A set of performance metrics generated during the pre-launch testing program will be compared to both the SNPP and JPSS-1 VIIRS sensors.

Oudrari, Hassan↗

Imaging spectrometry: Aircraft and space program

Imaging spectrometry for the remote sensing of the Earth is introduced. Reflected solar energy from the surface is dispersed in a spectrometer and used to form up to 200 registered spectral images. Each pixel has associated with it sufficient information for the reconstruction of a complete reflectance spectrum. The technique allows the diagnostic narrow band spectral features that are characteristic of many surface materials to be used to identify those materials. These spectral features are typically 20 to 40 nm wide; spectral imaging systems which acquire data in contiguous 10 nm bands therefore have sufficient resolution for direct identification of those materials with diagnostic spectral bands.

Abrams, M. J.↗

SNPP and N20 VIIRS Thermal Emissive Bands Calibration Comparison Using the GEO-LEO Double Difference Method

The VIIRS instruments onboard the SNPP and NOAA-20 satellites have identical spatial resolutions and the same spectral bands. Similar prelaunch tests and identical on-orbit calibration algorithms established the foundation for their consistent Earth measurements. Calibration assessment and consistency comparisons are useful to maintain their performance and measurement accuracy. Simultaneous nadir overpasses (SNO) between two satellites are commonly used for a direct calibration comparison between sensors. However, there are no SNO between SNPP and NOAA20. Hence, a reference sensor or Earth measurements are normally used to bridge the comparison. As a reference, we focus on the Advanced Baseline Imager (ABI) onboard the GOES-R series spacecraft and its application to the SNPP and NOAA-20 VIIRS comparison. GOES16 and GOES17are the first two satellites of the GOES-R series and were launched on November 19, 2016, and March 12, 2018, respectively. Their operational positions are on the equator with longitudes of 75.2° West over land and 137.2° West over ocean, respectively. The ABI is the primary imaging instrument of these spacecrafts for the Earth’s weather, oceans, and environment, with observations (every 10 minutes) that provide vast data for GEO-Low Earth orbit (LEO)and LEO-LEO comparisons utilizing it as an intermediate reference sensor. VIIRS and ABI have spectrally matched bands and can have simultaneous measurements over any selected site every day. The simultaneous measurements over the same site also have various scan angles. These features provide advantages for a VIIRS-to-ABI comparison. The spectral response function difference between instruments, sites selected, and view angles will have effects on the instrument measurements. Their impacts on the calibration comparison, including the use of double differences, will be discussed. By collecting VIIRS measurements over a large range of view angles, the view angle effect will also be investigated. The collection of an ample amount of data provides an advantage for statistical analyses and potential big data applications to sensor calibration assessments. This method can also be applied to other sensor calibration comparison and performance assessments, such as GOES16 and GOES17 ABI, and Terra and Aqua MODIS.

Tiejun Chang↗

Changes in vegetation spectra with leaf deterioration under two methods of preservation

Changes in leaf spectra caused by mineralization under different conditions of preservation are measured using a three-band portable radiometer which simulates three Thematic Mapper bands 3, 4, and 5. Daily spectral measurements of white oak (Quercus alba) leaves did not distinguish among the fresh, bottled, and bagged vegetation in the spectral bands 3 and 5 for up to four days after collection. The reflected energy of the preserved vegetation increased thereafter, reportedly due to the loss of chlorophyll and dehydration. It is concluded that the measurement procedure is sufficiently sensitive as to discern documented patterns of variation in reflectance measurements.

Labovitz, M. L.↗

A Ground-Based 200/350 Micrometer Polarization-Sensitive Photometer

We describe a concept for a polarization-sensitive photometer for use at the South Pole and Atacama that employs Transition-Edge Sensor (TES) detectors. We will use two 8x8 element array architecture originally developed at NASA Goddard for a 3 mm camera.for the Green Bank Telescope. The elements will be tuned to have absorption peaks in both the 200 and 350 micron atmospheric windows. This instrument will provide a testbed for three major issues confronting a future far-infrared polarimeter for SOFIA. The first is the TES detector technology. The second is a polarization modulator that can be quickly reconfigured for different passbands. The third is the ability to optimize polarimetric and photometric detection capabilities in the same instrument. Scientifically, this instrument will explore the emission from Galactic star-forming regions in two spectral bands, giving valuable information concerning their spectral energy distributions. Polarimetrically, this instrument will allow coverage of the polarization spectrum for bright Galactic sources, giving new insights into dust grain physics.

Chuss, David T.↗

Noise Spectra and Directivity For a Scale-Model Landing Gear

An extensive experimental study has been conducted to acquire detailed noise spectra and directivity data for a high-fidelity, 6.3%-scale, Boeing 777 main landing gear. The measurements were conducted in the NASA Langley Quiet Flow Facility using a 41-microphone directional array system positioned at a range of polar and azimuthal observer angles with respect to the model. DAMAS (Deconvolution Approach for the Mapping of Acoustic Sources) array processing as well as straightforward individual microphone processing were employed to compile unique flyover and sideline directivity databases for a range of freestream Mach numbers (0.11 - 0.17) covering typical approach conditions. Comprehensive corrections were applied to the test data to account for shear layer ray path and amplitude variations. This allowed proper beamforming at different measurement orientations, as well as directivity presentation in free-field emission coordinates. Four different configurations of the landing gear were tested: a baseline configuration with and without an attached side door, and a noise reduction concept "toboggan" truck fairing with and without side door. DAMAS noise source distributions were determined. Spectral analyses demonstrated that individual microphones could establish model spectra. This finding permitted the determination of unique, spatially-detailed directivity contours of spectral band levels over a hemispherical surface. Spectral scaling for the baseline model confirmed that the acoustic intensity scaled with the expected sixth-power of the Mach number. Finally, comparison of spectra and directivity between the baseline gear and the gear with an attached toboggan indicated that the toboggan fairing may be of some value in reducing gear noise over particular frequency ranges.

Humphreys, William M., Jr.↗

Calibration of VIIRS F1 Sensor Fire Detection Band Using lunar Observations

Visible Infrared Imager Radiometer Suite (VIIRS) Fight 1 (Fl) sensor includes a fire detection band at roughly 4 microns. This spectral band has two gain states; fire detection occurs in the low gain state above approximately 345 K. The thermal bands normally utilize an on-board blackbody to provide on-orbit calibration. However, as the maximum temperature of this blackbody is 315 K, the low gain state of the 4 micron band cannot be calibrated in the same manner as the rest of the thermal bands. Regular observations of the moon provide an alternative calibration source. The lunar surface temperature has been recently mapped by the DIVINER sensor on the LRO platform. The periodic on-board high gain calibration along with the DIVINER surface temperatures was used to determine the emissivity and solar reflectance of the lunar surface at 4 microns; these factors and the lunar data are then used to fit the low gain calibration coefficients of the 4 micron band. Furthermore, the emissivity of the lunar surface is well known near 8.5 microns due to the Christiansen feature (an emissivity maximum associated with Si-O stretching vibrations) and the solar reflectance is negligible. Thus, the 8.5 micron band is used for relative calibration with the 4 micron band to de-trend any temporal variations. In addition, the remaining thermal bands are analyzed in a similar fashion, with both calculated emissivities and solar reflectances produced.

McIntire, Jeff↗

Detectors and Focal Plane Modules for Weather Satellites

Weather satellite instruments require detectors with a variety of wavelengths ranging from the visible to VLWIR. One of the remote sensing applications is the geostationary GOES-ABI imager covering wavelengths from the 450 to 490 nm band through the 13.0 to 13.6 micron band. There are a total of 16 spectral bands covered. The Cross-track infrared Sounder (CrIS) is a Polar Orbiting interferometric sensor that measures earth radiances at high spectral resolution, using the data to provide pressure, temperature and moisture profiles of the atmosphere. The pressure, temperature and moisture sounding data are used in weather prediction models that track storms, predict levels of precipitation etc. The CrIS instrument contains SWIR (lamba(sub c) approximately 5 micron at 98K), MWIR (lambda(sub c) approximately 9 micron at 98K) and LWIRs (lamba(sub c) approximately 15.5 micron at 81K) bands in three Focal Plane Array Assemblies (FPAAs). GOES-ABI contains three focal plane modules (FPMs), (i) a visible-near infrared module consisting of three visible and three near infrared channels, (ii) a MWIR module comprised of five channels from 3.9 micron to 8.6 micron and (iii) a 9.6 micron to 13.3 micron, five-channel LWIR module. The VNIR FPM operates at 205 K, and the MWIR and LWIR FPMs operate at 60 K. Each spectral channel has a redundant array built into a single detector chip. Switching is thus permitted from the primary selected array in each channel to the redundant array, given any degradation in performance of the primary array during the course of the mission. Silicon p-i-n detectors are used for the 0.47 micron to 0.86 micron channels. The thirteen channels above 1 micron are fabricated in various compositions of Hg1-xCdxTe, and in this particular case using two different detector architectures. The 1.38 micron to 9.61 micron channels are all fabricated in Hg1-xCdxTe grown by Liquid Phase Epitaxy (LPE) using the HDVIP detector architecture. Molecular beam epitaxy (MBE)-grown Hg1-xCdxTe material are used for the LWIR 10.35 micron to 13.3 micron channels fabricated in Double layer planar heterostructure (DLPH) detectors. This is the same architecture used for the CrIS detectors CrIS detectors are 850 micron diameter detectors with each FPAA consisting of nine photovoltaic detectors arranged in a 3 x 3 pattern. Each detector has an accompanying cold preamplifier. SWIR and MWIR FPAAs operate at 98 K and the LWIR FPAA at 81 K, permitting the use of passive radiators to cool the detectors. D* requirements at peak wavelength are ≥ 5.0E+10 Jones for LWIR, ≥ 9.3E+10 Jones for MWIR and ≥ 3.0E+11 Jones for SWIR. All FPAAs exceeded the D* requirements. Measured mean values for the nine photodiodes in each of the LWIR, MWIR and SWIR FPAAs are D* = 5.3 x 10(exp 10) cm-Hz(exp 1/2)/W at 14.0 micron, 1.0 x 10(exp 11) cm-Hz(exp 1/2)/W at 8.0 micron and 3.1 x 10(exp 11) cm-Hz(exp 1/2)/W at 4.64 micron.

satellite instruments↗

High resolution derivative spectra in remote sensing

The use of derivative spectra is an established technique in analytical chemistry for the elimination of background signals and for resolving overlapping spectral features. Application of this technique for tackling analogous problems such as interference from soil background reflectance in the remote sensing of vegetation or for resolving complex spectra of several target species within individual pixels in remote sensing is proposed. Methods for generating derivatives of high spectral resolution data are reviewed. Results of experiments to test the use of derivatives for monitoring chlorosis in vegetation show that derivative spectral indices are superior to conventional broad-band spectral indices such as the near-infrared/red reflectance ratio. Conventional broad-band indices are sensitive to both leaf cover as well as leaf color. New derivative spectral indices which were able to monitor chlorosis unambiguously were identified. Potential areas for the application of this technique in remote sensing are considered.

Demetriades-Shah, Tanvir H.↗

On-Orbit Calibration and Performance of Aqua MODIS Reflective Solar Bands

Aqua MODIS has successfully operated on-orbit for more than 6 years since its launch in May 2002, continuously making global observations and improving studies of changes in the Earth's climate and environment. 20 of the 36 MODIS spectral bands, covering wavelengths from 0.41 to 2.2 microns, are the reflective solar bands (RSB). They are calibrated on-orbit using an on-board solar diffuser (SD) and a solar diffuser stability monitor (SDSM). In addition, regularly scheduled lunar observations are made to track the RSB calibration stability. This paper presents Aqua MODIS RSB on-orbit calibration and characterization activities, methodologies, and performance. Included in this study are characterizations of detector signal-to-noise ratio (SNR), short-term stability, and long-term response change. Spectral wavelength dependent degradation of the SD bidirectional reflectance factor (BRF) and scan mirror reflectance, which also varies with angle of incidence (AOI), are examined. On-orbit results show that Aqua MODIS onboard calibrators have performed well, enabling accurate calibration coefficients to be derived and updated for the Level 1B (L1B) production and assuring high quality science data products to be continuously generated and distributed. Since launch, the short-term response, on a scan-by-scan basis, has remained extremely stable for most RSB detectors. With the exception of band 6, there have been no new RSB noisy or inoperable detectors. Like its predecessor, Terra MODIS, launched in December 1999, the Aqua MODIS visible (VIS) spectral bands have experienced relatively large changes, with an annual response decrease (mirror side 1) of 3.6% for band 8 at 0.412 microns, 2.3% for band 9 at 0.443 microns, 1.6% for band 3 at 0.469 microns, and 1.2% for band 10 at 0.488 microns. For other RSB bands with wavelengths greater than 0.5 microns, the annual response changes are typically less than 0.5%. In general, Aqua MODIS optics degradation is smaller than Terra MODIS and the mirror side differences are much smaller. Overall, Aqua MODIS RSB on-orbit performance is better than Terra MODIS.

Xiong, Xiaoxiong↗