Spontaneous Phase Balancing in Delta-Connected Single-Phase Droop-Controlled Inverters
Not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not provided.
As part of the Cyclotron Road program, Laminera Inc. worked towards development of atomic layer deposition process customizations and tool modifications to produce synthetic metal films at commercial scale and improve the film quality. Today's state-of-the-art in atomic layer deposited synthetic metal technology is only possible at a research-scale because current tools have practical limitations for scaling industrially and generating high conductivity films. Ultrathin, conformal synthetic metal films have many possible applications such as high surface area nanoporous electrodes for supercapacitors and water desalination devices; protective electrode coatings for electrochemical devices; seed layers for semiconductor device fabrication; or metallic component stabilizing coatings that enable enhanced storage density in next generation hard disk drives. The best synthetic metal conductive and plasmonic properties have been demonstrated using sputtering, which relies on high temperature sputtering with substrate dependent and directional growth limiting usage. This work explored refining process and tool modifications to create ultrathin, conformal, synthetic metal films that can be deposited with high quality over complex three-dimensional surfaces.
A paint binder is described which uses a potassium or sodium silicate dispersion having a silicon dioxide to alkali-metal oxide mol ratio of from 4.8:1 to 6.0:1. The binder exhibits stability during both manufacture and storage. The process of making the binder is predictable and repeatable and the binder may be made with inexpensive components. The high mol ratio is achieved with the inclusion of a silicon dioxide hydrogel. The binder, which also employs a silicone, is in the final form of a hydrogel sol.
This presentation gives a comparative analysis of degradation processes, failure modes and mechanisms in MnO2 and polymer technology capacitors. Analyzed conditions include effects of vacuum and radiation, soldering (pop-corning), long-term storage, operation at high temperatures, stability at low and high temperatures, and anomalous transients. Screening and qualification procedures to assure space-grade quality of CPTCs are suggested.
The integration of renewable energy sources into power grids necessitates solutions for grid support and stability during fluctuations in electricity generation and demand. Gravity energy storage systems (GESS) are emerging as a promising technology for managing the balance between the energy supply and demand. However, their capacity to optimize energy flow and offer voltage and frequency regulation amid generation-demand imbalances is less reported. This paper investigates the control of GESS for optimizing energy flow during voltage and frequency regulation. The study evaluates the regulation capabilities of GESS with different motor inertias during a Texas grid event: one with a high-speed, low-inertia motor and another with a low-speed, high-inertia motor. Results indicate that both GESS systems provide fast frequency response by converting potential energy into kinetic energy and vice versa, with a response time of 1.5 seconds from the frequency variation. This aligns with grid requirements for primary frequency response from traditional synchronous generators and motors with large inertia. Furthermore, a GESS with a high-inertia motor may be able operate over a broader range of frequency variations whereas a low-inertia system may be limited by thermal constraints of the motor.
This paper presents a stability analysis of parallel-connected bi-directional series-series resonant network wireless power transfer (WPT), optimized for Electric Vehicle (EV) charging and vehicle-to-grid (V2G) applications. The study addresses critical stability challenges in systems integrated with diverse distributed energy resources (DERs), including photovoltaics, fuel cells, wind turbines, energy storage systems, and the AC grid. The stability of such integrated DC grid systems is paramount for ensuring reliable operation, particularly under varying power flow conditions and dynamic interactions between parallel WPT systems. The analysis included system impedance characterization, state-space modeling, and open and closed-loop stability evaluations. The results demonstrated that the integration of a robust control architecture effectively mitigates instability risks and supports scalable, efficient operation. This work underscores the converter's adaptability and its potential for large-scale deployment in wireless EV charging infrastructures and integrated DC grid systems.
Energy storage is fundamental to ensuring the reliability, stability, and resilience of the grid, essential for meeting the energy demands now and in the future. Pumped storage stands out as a proven energy storage solution. There are 43 pumped-storage plants operating in the USA today, and they offer unparalleled scalability, rapid-response capabilities, and long-term reliability at a competitive cost. With a history of successful operation spanning decades, and approximately 60 sites proposed at various stages of permitting and development, this technology is a critical component for the US energy sector. However, its development involves some complex engineering and regulatory challenges.
Prior to the deployment of prolonged deep space missions which may carry increased crew health risks, it is essential to determine the effect that missions beyond the Van Allen Belt will have on physiology. Historically the National Aeronautics and Space Administration (NASA), Human Research Program (HRP) has developed, conducted, and delivered research findings and countermeasures that will maintain the health and safety of crews aboard the International Space Station (ISS) in anticipation of future exploration class missions. To support these objectives, research operations on ISS typically include the collection and storage of human physiological samples and their return to Earth for analysis. Transition to Gateway and Artemis lunar exploration will limit the available up mass and biosample return capability resulting in new challenges to monitor crew health during the mission. The Artemis lunar missions provide a perfect opportunity to assess new technology that could support crew biosample return that is compatible with the severe operational constraints of Artemis mission design. Dried biosample chemistry analysis is a potential technology that can enable the collection of samples and tracking of crew health during these exploration class missions. The development and implementation of dried biosample chemistry technology for tracking immune health, viral reactivation and hormone fluctuations provide a simple alternative strategy for sample collection and sample return (light weight non-conditioned stowage option) for the continuation of human research during Artemis missions. Saliva is established as an informative biosample that has both its own unique available analytes as well as others that are also present in blood. Saliva is already routinely collected from ISS astronauts for the detection of stress hormones and latent virus DNA. The ‘Dry Saliva’ book sample collection/storage protocol, already successfully deployed to ISS, represents a perfect method for collecting biosamples from Gateway and Artemis astronauts because it requires a simple, non-invasive sample collection protocol, minimum volume, and uses non-conditioned storage. We are currently conducting an expanded stability study of the dry saliva analyte platform to include additional stress hormones, cytokines, antimicrobial proteins, and latent virus DNA as well as other markers of immunity and inflammation. Validation testing on parabolic flight will establish collection methods for saliva and blood to dry sampling substrates to finalize the collection protocols for flight. For the new expanded analyte stability study, a short-term stability study with time points out to 14 days has been completed with analysis underway to determine whether additional analytes could be recovered, as well as assessing the best storage conditions for the samples collected. In parallel, a long-term stability study is being conducted out to 1 year to improve the stability of some unstable analytes. To this end, the NASA Johnson Space Center’s Immunology/Virology lab is currently finalizing the saliva dry chemistry platform, including assay compatibility and stability studies. This technology is approved to be implemented, as part of the ‘Biomarkers’ study, during Artemis II through Artemis IV lunar missions.
Successful implementation of forest management as a nature-based climate solution is dependent on the durability of management-induced changes in forest carbon storage and sequestration. As forests face unprecedented stability risks in the face of ongoing climate change, much remains unknown regarding how management will impact forest stability, or how interactions with climate might shift the response of forests to management across spatiotemporal scales. Here, we used a process-based model to simulate multidecadal projections of forest dynamics in response to changes in management and climate. Simulations were conducted across gradients in forest type, edaphic factors, and management intensity under two alternate radiative forcing scenarios (RCP4.5 and RCP8.5). This allowed for the quantification of forest stability shifts in response to climate change, and the role of management in modulating that response, where ecosystem stability is characterized as the resilience and temporal stability of net primary production, aboveground biomass, and soil carbon. Our results indicate that forest structure is primarily shaped by management, but the same management strategy often produced divergent structures over time, due to interactions with regional climate change. We found that management can be used to increase stability and minimize the release of stored carbon by reducing mortality, but also highlight the regional dependency of management-induced changes in resilience to climate change.
Solid amine sorbents are one of the primary components of DAC technologies that allow for the removal of ultradilute CO 2 from the atmosphere. A main drawback in the implementation of solid amine sorbents in industrial-scale DAC applications is their instability under certain operational or storage conditions over an extended period. In this work, the effect of storage temperature and gas composition in the storage headspace on the long-term stability of a poly(ethylenimine)-alumina (PEI/γ-Al 2 O 3 ) sorbent is explored. PEI/γ-Al 2 O 3 sorbents with 70 and 100% pore filling are aged under varying gases (N 2 , O 2 , Ar, 0.04% CO 2 −N 2 , CO 2 , and ambient air) in an oven (40 °C), at common ambient indoor temperature conditions (23 °C), or in a freezer (−4 °C). The CO 2 sorption capacity, as measured by thermogravimetric analysis (TGA), along with FTIR spectra of the fresh and aged sorbents, reveal that at 23 and −4 °C, storage under ambient air or inert gas (Ar) provides reasonable long-term stability, with <13% degradation over 12 and 5 months of storage. Interestingly, with storage at 40 °C, similar levels of deactivation were observed under pure O 2 and N 2 after 4 months of storage, which suggests that nonoxidative thermal reactions can occur under prolonged storage conditions under N 2 . In contrast, with storage under CO 2 , sorbent degradation is substantially suppressed compared to storage under N 2 , ambient air, O 2 , or Ar, yielding sorbents with no observable loss in capacity after 2 months, compared to a 66, 63, and 62% loss under N 2 , ambient air, and N 2 in the same period at 40 °C, respectively. Overall, these findings provide guidance for practical amine sorbent storage in academic or industrial settings where amine sorbents are used for carbon capture.
The viewgraphs of a discussion on the stability of recording media presented at the National Space Science Data Center (NSSDC) Mass Storage Workshop is included. An overview of archival stability of recording media is presented. Co-gamma-Fe2O3 tape is discussed. Other topics covered are magnetic tape components, dimensional stability and crossply, acetone extraction, coercivity, and phi R percent change.
High-nickel layered oxides (LiNi 1-x-y Mn x Co y O 2 ) are the prevailing cathode materials for high-energy-density lithium-based batteries, but they are plagued with deleterious surface air instabilities stemming from residual lithium formation. These issues severely hinder mass production as cathode calcination is limited to a flowing oxygen atmosphere, which entails high manufacturing costs as opposed to simpler and more economical air calcination. Here, while higher Ni contents are known to worsen air instabilities, the influence of Mn and Co contents on impacting these phenomena are less elucidated. We herein present the synthesis in ambient air and flowing oxygen atmospheres of three cathode variants with the same Ni contents, but varying Mn and Co contents: LiNi 0.7 Mn 0.3 O 2 , LiNi 0.7 Mn 0.15 Co 0.15 O 2 , and LiNi 0.7 Co 0.3 O 2 . It is found that the critical parameter influencing the air stability of the cathodes is the average Ni oxidation state, which is greatly dependent on the Mn and Co contents. Substitution of Mn for Ni drives down the Ni oxidation state as Mn exists as Mn4 + and reduces surface residual lithium formation, which vastly improves the overall air stability and, therefore, the synthesizability in air, but with a penalty of lowered capacity. In contrast, substitution of Co for Ni maintains Ni 3+ as Co exists as Co 3+ , offering increased initial capacity, but worsens the air stability and cyclability as the driving force for residual lithium formation and surface reactivity is increased.
The NASA BioNutrients missions seek to understand the suitability of microorganisms for bioproduction during space flight. One topic of interest is the stability of microbial genomes during long-term ambient storage and subsequent rehydration and growth. To address these questions, samples from 8 species were flown to ISS for 5 years of desiccated storage at ambient temperature (Stasis Packs) and 2 species were packaged along with powdered media inside a bioreactor system to allow hydration and growth in microgravity (Production Packs). For both systems, Whole Genome Sequencing (WGS) of the DNA extracted from the returned samples and paired ground controls will be conducted to identify changes in genome stability due to time, storage conditions and growth in space. Across the technical replicates, ground controls, 10 timepoints, and multiple experimental conditions, ~300 samples have been selected for initial analysis with WGS sequencing to 100x coverage. A flexible and resource efficient mutation calling pipeline is needed to process this large dataset and allow for comparisons between species. Many bioinformatics tools for calling Indels and Single Nucleotide Variants (SNVs) are designed for use with pure isolates, where true variations from the reference genome are expected to dominate the reads aligning to the location of mutation. In contrast, DNA from the Stasis Pack (SP) samples was collected directly after recovery from desiccated storage and the Production Pack (PP) samples were collected after fermentation. In this context, reads with mutations are expected to be less frequent than reads that align with the reference genome, as each sample will include multiple lines of cells. Thus, BioNutrients samples are expected to be similar to samples from cancer cell or “pooled” sequencing approaches. In preparation for the analysis of the BioNutrients samples, we have tested three mutation calling tools (GATK for Microbes, BreSeq and DiscoSNP) designed for complex samples. A challenge of validating mutation identification pipelines is a lack of “Ground Truth” datasets, especially for complex samples. To compare these three tools, we sought to identify mutations in pre-existing WGS data collected from populations of Chlamydomonas reinhardtii that were exposed to UV mutagenesis and growth in LEO as part of the Space Algae-1 mission. Here we present a summary of these tools against the analysis originally conducted using the CRISP tool. Critical metrics are compared such as runtime, the number of SNPs, the number and size of Indels, and patterns of transversion and transitions identified by each tool are reported. By sharing these benchmarking results collected in support of the BioNutrients mission, we aim to guide others seeking to identify SNVs in similarly complex microbial samples.
Graphite is the preferred anode material in commercial lithium-ion batteries (LIBs), but its limited compatibility with various organic molecules restricts the electrolyte solvent options. The primary challenge is solvent co-intercalation with Li ions, leading to graphite layer exfoliation. As a result, electrolyte selection often relies on ethylene carbonate (EC)-based solvents. Here, in this study, we introduce electrolytes featuring a nanoscale anion network ordering that hinders the liquid-phase exfoliation of graphite. This network, formed from concentrated long-chain lithium salts, traps free dioxolane (DOL) molecules, reducing the interactions between graphite particles and solvents during Li intercalation. Our findings reveal a mechanism that stabilizes graphite in otherwise unstable solvents with concentrated salts like LiTFSI, providing key insights for improving LIB performance by addressing electrolyte limitations on graphite anodes.
Practical Mg batteries require electrolytes that are stable both toward reduction by Mg metal and oxidation by high voltage cathodes. State-of-the-art Mg electrolytes based on weakly-coordinating Mg salts utilize standard ether-type solvents (usually glymes) due to their reductive stability. However, the oxidative stabilities of these solvents are less than ideal, leading to difficulties in realizing the high oxidative stabilities of novel salts. On the other hand, alternative solvents with greater oxidative stability are typically unable to support Mg cycling. Here, in this work, we report a selective solvation approach involving the combination of glyme and hydrofluoroether solvents. Selective solvation of Mg 2+ by the glyme solvent component increases the oxidative stability of the glyme while maintaining sufficient reductive stability of the noncoordinating hydrofluoroether. We show that this approach enables the design of electrolytes with greater oxidative stability than glyme-only electrolytes while retaining enough reductive stability to cycle Mg metal. We also relate the influence of various coordination interactions among the solvents and anions with Mg 2+ to their electrochemical stabilities to better inform the design of future electrolytes.
We demonstrate the application of fluorescence optical fiber coupled to a telecom grade fiber as a sensor for alpha particles using alpha-specific ZnS(Ag) scintillation materials whose wavelength is down-shifted into a low-loss region of the telecom grade fiber transmission band. Telecom-grade fiber optics offer a solution for sensing alpha radiation in deep repositories and cask storage for radioactive materials due to the stability of SiO 2 under normal environmental conditions and its relative radiation hardness at low radiation doses. Long-term nuclear waste storage facilities require sensors for the detection of leakage of radioactive materials that are maintenance-free, do not require power and can survive with no ‘wear out’ mechanisms for decades. By accomplishing the wavelength transformation, we maximize efficiencies in the detection of α-particles and signal transport and can detect alpha scintillation at distances on the order of >1 km with a sensor that is ~3% efficient and can be easily scaled as a sensor array. This paper describes the construction and testing of the sensor including manufacture of the controlled thickness films, verification of the wavelength shift from 450 to 620 nm and optimization of the sensitivity as a function of thickness. We also model the relative sensitivity of the film as a function of film thickness, and we demonstrate a signal-to-noise ratio of 10 at a range of greater than 1 km.
An assessment and verification of previous analytic results on the long term risk of earth reentry for hazardous payloads is presented. The two areas were studied: (1) stability of nominal, near-circular storage orbits in the regions between Venus and earth and between earth and Mars, and (2) probability of earth reentry for off-nominal planet-crossing orbits resulting from deployment system failures. In the first area, numerical integrations of the equations of motion are compared with stability predications based on secular perturbation theory. The agreement is good in terms of the heliocentric distances covered and the general behavior of the orbital history, although certain near-resonance situations can lead to difficulty. In the second area, a Monte Carlo simulation of orbital evolution is used and the results compared with Opik's analytic theory of planetary encounters and collision statistics, with data verified to within a close order-of-magnitude.