Search NASA⌕ Search

SEARCH · Search NASA

Results for “STORAGE UNIT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Using energy storage systems to extend the life of hydropower plants

Despite their advantages, distributed energy resources (DERs) bring inherent uncertainty and variability into the landscape of modern power systems. As DER penetration grows, conventional generators like hydropower plants have to respond more often to arrest the imbalance in the net load. Hydropower turbines provide their best operational performance with minimal wear and tear when operating at regions of maximum efficiency. However, the current needs for hydropower plants require them to operate under varying load conditions and thus sub-optimal operating points leading to additional stress. To relieve the hydropower plants, this paper proposes a hybridization strategy where a hydropower unit is paired with an energy storage system (ESS) to increase operational flexibility and mitigate damage to the hydro plant. Models are developed to represent the operation of the hybrid system, quantify degradation, and assess economic benefits. Moreover, an innovative controller disaggregates the market dispatch signal into separate control setpoints for the ESS and hydropower unit. In case studies performed on a real-world hydropower facility, it was found that the ESS-based hybridization can extend the life of the hydropower plant by 5% on average. Notably, the economic benefits from reduced maintenance and deferred investment are estimated to be around $3.6 million.

13 HYDRO ENERGY↗

Investigation into Sizing Photovoltaic with Energy Storage for Off-Grid Transactive Scenarios

In this study, a novel sizing methodology was developed for centralized and interconnected operating strategies of transactive microgrids and several variables were investigated including starting month, initial charge of battery, load variability, unit cost of solar panels and energy storage, number of systems, climate, and required reliability to determine their effect on total cost. The centralized strategy improved cost by seven to ten percent compared to the isolated strategy in every case. The interconnected strategy saved an incremental amount of money consistently compared to the isolated standard. The number of connected systems was not a strong effect. It was thought that increasing the number of systems would increase the benefit of energy sharing. Climate zones studied (“Cold”; “Hot-Dry/Mixed Dry”; “Mixed Humid”; and “Cold but with lower solar irradiation”) showed a large variation on cost with the Hot-Dry/Mixed Dry being the least expensive and Cold, with lower solar irradiation being the most expensive. Cost sensitivity analysis was performed showing that the unit cost of solar has a greater effect on the total cost. Required reliability of power, measured in outage hours, exhibited an inverse relation with cost.

14 SOLAR ENERGY↗

Impact of Rock Wettability and Mineralization on CO 2 Storage Efficiency in Basalt Reservoirs

Basalt formations have emerged as highly promising targets for geological CO 2 storage due to their abundance of reactive silicate minerals that can rapidly convert dissolved CO 2 into stable carbonate minerals. The efficiency of CO 2 trapping in basalts, however, depends not only on their geochemical reactivity but also on reservoir wettability, which governs how CO 2 partitions among structural, residual, solubility, and mineral trapping mechanisms. However, wettability and mineral kinetics have largely been examined separately, wettability for plume migration and kinetics in terms of mineralization, leaving their coupled impact unquantified. Here, we systematically integrate th ese processes in a reservoir-scale reactive transport model to quantify the impact of three distinct wettability conditions (water-wet, mixed-wet, and CO 2 -wet) on plume migration, mineral precipitation, pore-scale blockage, and long-term immobilization. Results show that under ideal conditions (no mineralization), water-wet systems exhibited plume aspect ratios up to 28% higher than CO 2 -wet systems and promoted at least 60% greater residual trapping. When mineralization was incorporated, mineral trapping accounted for 57%, 53%, and 46% of the total immobilized CO 2 in water-wet, mixed-wet, and CO 2 -wet systems, respectively. Dissolved CO 2 contributed 43-46%, while residual trapping remained below 5%, and mobile CO 2 was substantially reduced due to mineralization, demonstrating that as the system becomes more water-wet, CO 2 is more effectively converted into stable carbonate minerals, although extensive mineral precipitation may lead to pore clogging. A global Sobol-Morris sensitivity analysis further reveals that the kinetic parameters of reactive minerals are the most influential factor, followed by wettability, while salinity has only a minor influence. Furthermore, these findings highlight that wettability is not merely a flow property but a fundamental control on CO 2 mineralization in basalts, with direct implications for site selection for storage projects.

Basalts↗

Techno-Economic Analysis for the Addition of Thermal Energy Storage to a Campus With Existing Battery Storage

Rising global temperatures and increasing energy demands pose significant challenges for energy management, particularly in institutional and commercial settings. As cooling needs grow, campuses must balance operational efficiency, cost control, and grid stability. Energy storage solutions, such as thermal energy storage (TES) systems, offer a promising approach to shifting energy consumption from peak to off-peak periods, alleviating peak demand, reducing utility costs, and enhancing grid resilience. When integrated with existing battery energy storage systems (BESS), TES can further optimize load management and improve energy savings, especially in buildings with diverse energy needs. This article presents a techno-economic analysis of integrating a chilled water TES system into the central plant at California State University, Dominguez Hills, which already operates a BESS. We assess three TES sizing strategies—full storage, load leveling, and peak demand limiting—by modeling and simulations based on historical energy loads. Our findings show that we can control TES systems to complement BESS operation, with campus-level load leveling providing the greatest cost savings by reducing peak demands. Furthermore, the study also evaluates the long-term economic viability of TES, considering installation costs, energy savings, and payback periods under varying tariffs. This research offers practical guidance for institutions seeking to enhance energy resilience and reduce operational costs through energy storage solutions.

25 ENERGY STORAGE↗

Advanced Energy Storage for Extreme Conditions (AESTEC) (Abbreviated Final Report)

This project developed a new capability for designing and fabricating energy storage devices that function in extreme conditions detrimental to conventional devices (e.g. temperature, mechanical stress, etc.). This new toolset tackled critical phenomenological challenges which led to materials and designs that enable high performance energy storage in conditions relevant to national security missions and the broader energy storage community.

25 ENERGY STORAGE↗

Benefits of Energy Storage for Washington, D.C.: Analysis for the Department of Energy and Environment

This report analyzes the potential for using energy storage to create energy savings for residents of Washington, D.C. in light of recent increases in energy market prices. It describes the role of energy storage in avoiding market costs, quantifies the specific benefits that could be achieved with energy storage deployments in Washington, D.C., and then presents case studies of how utilities and other states have created programs to achieve cost savings with energy storage.

25 ENERGY STORAGE↗

Deposition, Diagenesis, and Sequence Stratigraphy of the Pennsylvanian Morrowan and Atokan Intervals at Farnsworth Unit

Farnsworth Field Unit (FWU), a mature oilfield currently undergoing CO2-enhanced oil recovery (EOR) in the northeastern Texas panhandle, is the study area for an extensive project undertaken by the Southwest Regional Partnership on Carbon Sequestration (SWP). SWP is characterizing the field and monitoring and modeling injection and fluid flow processes with the intent of verifying storage of CO2 in a timeframe of 100–1000 years. Collection of a large set of data including logs, core, and 3D geophysical data has allowed us to build a detailed reservoir model that is well-grounded in observations from the field. This paper presents a geological description of the rocks comprising the reservoir that is a target for both oil production and CO2 storage, as well as the overlying units that make up the primary and secondary seals. Core descriptions and petrographic analyses were used to determine depositional setting, general lithofacies, and a diagenetic sequence for reservoir and caprock at FWU. The reservoir is in the Pennsylvanian-aged Morrow B sandstone, an incised valley fluvial deposit that is encased within marine shales. The Morrow B exhibits several lithofacies with distinct appearance as well as petrophysical characteristics. The lithofacies are typical of incised valley fluvial sequences and vary from a relatively coarse conglomerate base to an upper fine sandstone that grades into the overlying marine-dominated shales and mudstone/limestone cyclical sequences of the Thirteen Finger limestone. Observations ranging from field scale (seismic surveys, well logs) to microscopic (mercury porosimetry, petrographic microscopy, microprobe and isotope data) provide a rich set of data on which we have built our geological and reservoir models.

04 OIL SHALES AND TAR SANDS↗

A dynamically bare metal interface enables reversible magnesium electrodeposition at 50 mAh cm −2

Understanding and facilitating pure magnesium nucleation/growth electrodeposition behavior with ultrahigh Coulombic efficiency is complicated by the phenomenon of solid electrolyte interphase (SEI) formation in state-of-the-art, halogen-free magnesium electrolytes. Defining the electrolyte properties necessary to achieve ideal electrodeposition/stripping (E/S) thus remains elusive. Here, in this work, we reveal for the first time, rapid magnesium electrodeposition behavior that forms densely aligned, micron-sized thin platelets by establishing a dynamic bare magnesium/electrolyte interface during high-rate net plating. This effectively “SEI-free” interface allows facile magnesium diffusion and migration in stripping with near-unity E/S efficiency under demanding conditions over long-term cycling. The intrinsic electrolyte stability of the salt/solvent at the molecular level is the key to forming such an interface. The efficacy of the dynamic bare interface and an electrodeposited, free-standing magnesium anode is demonstrated in a high-areal-capacity full cell. These findings provide new design principles and fundamental understanding of interfacial chemistry in multivalent metal batteries.

Mg full cell↗

An assessment of existing barriers to market adoption of thermal energy storage in buildings based on interviews with stakeholders

The United States administration recently established a goal of reducing greenhouse gas emissions by half below 2005 levels by 2030 and becoming a carbon-neutral economy by 2050. The transition to renewable energy sources may be significantly aided by energy storage. Energy storage could smooth the delivery of variable or intermittent renewable energy sources such as wind, hydro, and sun by storing excess renewable energy when it’s available and delivering it back when renewable energy production is low. Thermal energy storage (TES) is a way that stores thermal energy by heating or cooling a storage medium, which is then used for space heating and cooling, industrial processes, or power generation purposes later. This TES operation could lessen the demand for electricity in both the winter's and the summer's peak hours of electricity. While there are various studies that focus on the advancements and successes of TES technology, less attention is placed on its market adoption. Therefore, the current study undertakes survey-based interview research to understand the existing market barriers hindering TES application in buildings. A series of interviews were performed in this study with individuals from various backgrounds, ranging from homeowners to market specialists who work for TES manufacturers and utility companies. According to the responses obtained during the interviews, they strongly believe that TES has a high potential to contribute to the nation's grid stability and decarbonization goals, however, there are several barriers that prevent homeowners and heat pump manufacturers from investing in TES applications. The current study divided the responses from various background groups into categories to better understand the current challenges for TES applications in buildings. These responses range from payback concerns from homeowners to the need to develop a new metric to represent the benefits of TES from the heat pump and TES manufacturers. The findings from this study can be used by policymakers, utility companies, and manufacturers to better understand present obstacles and develop strategies to overcome them.

Prem Anand Jayaprabha, Jyothis Anand↗

Solar Photovoltaic and Storage Supply Chains and Technology and Market Opportunities

This talk will highlight the most recent efforts from the National Renewable Energy Laboratory (NREL) to track solar photovoltaic (PV) and storage supply and demand in the United States and globally, as well as bottom-up calculations of manufacturing costs for facilities across the globe. We will begin with an overview of the global solar PV supply chain and 2022 benchmark input data used for NREL's bottom-up crystalline silicon (c-Si) and thin film PV module manufacturing cost models. For the polysilicon, wafer, cell conversion, and module assembly steps of the c-Si supply chain, and for thin film modules, we will review the industry-collected input data and methods used for calculating the costs of goods sold (COGS); research and development (R&D) expenses; and sales, general, and business administration (S, G, and A) expenses. This 2022 benchmark analysis is compiled for state-of-the-art c-Si and thin film PV module manufacturing in several countries and regions; and will also include a quantified summary of the impacts of the manufacturing incentives and tax credits that are available for solar manufacturing and installations within the United States. Next generation technologies that lower PV manufacturing and installation costs, reduce operations and maintenance (O&M) expenses, and improve system energy yield will also be highlighted. We will conclude with projections of solar market penetration to 2050 from NREL's Solar Futures Study and Annual Technology Baseline (ATB) model, which includes solar coupled with lower-cost storage scenarios as well as the range of future cost scenarios for other power generation sources. We look forward to sharing NREL's extensive work in these areas and discussing ideas for future directions.

economics↗

Decoding the Effect of Anion Identity on the Solubility of N -(2-(2-Methoxyethoxy)ethyl)phenothiazine (MEEPT)

Variations in the solubility of redox-active organic molecules (ROM) of interest for nonaqueous redox flow batteries (RFB), especially as the ROM state-of-charge changes during charge-discharge cycling, present significant molecular design challenges. The situation is further complicated as ROM solubility can be regulated by the choice of electrolyte salt and solvent that together with the ROM comprise the catholyte or anolyte (redox electrolyte) formulation, presenting materials design challenges. The ROM N-(2-(2-methoxyethoxy)ethyl)phenothiazine (MEEPT) is a viscous liquid at room temperature and is miscible in several organic solvents, including acetonitrile and propylene carbonate. The MEEPT radical cation (MEEPT +· ) paired with tetrafluoroborate (BF 4 - ) in acetonitrile presents a 0.5 M solubility, a dramatic decrease when compared to the viscous liquid of neutral MEEPT. Here, in this study, we present a joint experimental, regression modeling, and molecular dynamics (MD) simulations investigation to explore MEEPT-X (where X represents the counteranion) salt solubility variability as a function of concentration and counteranion chemistry in acetonitrile. We find a strong dependence of the salt solubility on the counteranion and relate these findings to explicit intermolecular interactions between MEEPT +· and the counteranion in the electrolyte solution.

Perera, Anton S. [Univ. of Kentucky, Lexington, KY↗

Prospective Seal Unit Spatial Extent Database for U.S. Sedimentary Basins

The Prospective Seal Unit Spatial Extent Database for U.S. Sedimentary Basins contains a series of spatial datasets representing spatial extents of publicly available data for caprock and seal rock units within the Appalachian Basin, Denver-Julesburg Basin, Great Valley Basin (Sacramento and San Joaquin Basins), Illinois Basin, Michigan Basin, San Juan Basin, U.S. Gulf Coast Basin, and Williston Basin. The database is designed to support carbon storage feasibility and resources assessment for carbon transport and storage (CTS) projects while displaying the spatial extent of prospective seal units and provide a guide to the original data source. This database leverages publicly available data resources from authoritative sources (e.g. U.S. Geological Survey, State Geologic Surveys, and published reports), and aims to help guide users to understand the seal unit's spatial coverage and data gaps from the regional to sub-basin/field scale. The database is organized by seal unit/formation, including the spatial extent for data found to be available for the seal unit. The various datasets represented include spatial extents of the lithologic formation, depth to top structural contour maps, and thickness/isopach maps. Included in this submission are the following resources: 1. Geodatabase/Dataset: “prospective-seal-unit-extents-2025.gdb” 2. ReadMe: “readme-prospective-seal-unit-spatial-extent-dataset-2025.pdf” 3. Data Catalog: “prospective-seal-unit-spatial-extents-data-catalog-2025.xlsx” 4. Data Sources Key: “data-source.csv” Please see NETL disclaimers here: https://netl.doe.gov/home/disclaimer

Basin↗

Modeling the influence of the solid electrolyte interphase on the sand’s time and dendrite formation on lithium metal electrodes

Lithium metal is a sought after battery material for its high energy density due to the low electrochemical potential and density. However, lithium metal is also highly reactive, which results in a strong propensity for dendrite formation. The Sand’s time has previously been used to predict the time of dendrite initiation on metals that do not form a solid-electrolyte interphase (SEI), but it has been shown that the Sand’s time is not accurate for lithium electrodes when using transport parameters associated with the electrolyte. Thus, we built a numerical model to simulate lithium ion transport through a growing SEI to predict the Sand’s time. The numerical model is shown to be more accurate than previous analytical solutions, especially for low current densities. We then analyze the sensitivity of the Sand’s time to different SEI properties and the chemical potential gradients present in the SEI, driving lithium transport. The results showed that high lithium concentration has a greater impact at high current density, while fast diffusivity is more important at low current density. Lastly, we modeled the influence of surface roughness on the plating evolution and chemical potential gradients when an SEI is present in comparison to the electrolyte. As a result, we demonstrate that the SEI plays a critical role in lithium electrode stability, and that improved characterization techniques are needed to better understand transport through the SEI and increase lithium metal utilization in energy storage devices.

Chemistry↗

Influence of Electrolyte Additives on Interfacial Stability of Manganese-Rich Lithium-Ion Battery Cathodes

Affordable, long-lasting energy storage has become critical to support increased electricity demand in recent years. Cobalt-free, lithium- and manganese-rich lithium nickel manganese oxide (LMR-NM) cathodes stand to reduce cost and supply-chain concerns associated with traditional cobalt-containing cathodes for lithium-ion batteries by leveraging more earth-abundant materials; however, they have shown issues with long-term cycling stability. Here, we investigate lithium difluoro(oxalate)borate (LiDFOB), tris(trimethylsilyl) phosphite (TMSPi), and vinylene carbonate (VC) electrolyte additives for their ability to improve cycling performance of LMR-NM (0.3 Li 2 MnO 3 + 0.7 LiMn 0.5 Ni 0.5 0 2 ) cells. Cryogenic scanning transmission electron microscopy (cryo-STEM) with electron energy loss spectroscopy enables the construction of a structure–function relationship between cathode electrolyte interphase (CEI) characteristics and the electrochemical performance of cells aged with these additives. We find the combination of 2 wt % TMSPi + 1 wt % LiDFOB performs better than any single additive, achieving a 28% improvement in specific capacity over the baseline electrolyte after long-term cycling. We attribute this to LiDFOB mitigating Mn ion dissolution, with cryo-STEM showing Mn stabilized up to the CEI surface, coupled with improved CEI structure and chemistry enabled by TMSPi, evidenced by a moderately thick (∼7–15 nm) CEI that appears to protect against further electrolyte reactions with the particle. These results, achieved through site-specific nanoscale characterization, directly reveal mechanisms through which electrolyte engineering can improve the performance of earth-abundant cathodes, enabling informed development of more affordable and reliable batteries to meet future energy storage needs.

25 ENERGY STORAGE↗

West Africa Battery Energy Storage Systems (BESS) Capacity Building - Discussion of BESS Tariffs: Payment Structures and Case Studies [Slides]

Battery Energy Storage Systems (BESS) are emerging as critical assets for enhancing grid reliability, integrating renewable energy, and enabling system flexibility. Yet, the regulatory and financial frameworks that determine how BESS projects are compensated vary widely across jurisdictions. This presentation explores international case studies - from Honduras, Costa Rica, Chile, South Africa, Mexico, and Brazil - to illustrate how tariff design and payment structures are evolving to support large-scale BESS deployment. The cases highlight a range of ownership and revenue models, including cost-of-service mechanisms, energy and capacity payments, and market-based arbitrage, as well as hybrid approaches under development. The discussion will examine key challenges such as defining remuneration for ancillary services, addressing double charging, and accounting for efficiency losses and degradation over time. By comparing experiences across markets, the presentation identifies emerging best practices for valuing BESS and designing tariffs that align technical performance with economic incentives, providing insights for regulators, utilities, and policymakers pursuing storage integration.

25 ENERGY STORAGE↗

Regulations, Codes, and Standards Review for Underground Hydrogen Storage

Hydrogen continues to show promise as a viable contributor to achieving energy storage goals such as energy security and decarbonization in the United States. However, many new and expanded hydrogen use applications will require identifying methods of larger-scale storage than the solutions that currently exist for smaller storage applications. One possibility is to store large quantities of gaseous hydrogen below ground level. Underground storage of other fuels such as natural gas is already currently utilized, so much of the infrastructure and basic technologies can be used as a basis for underground hydrogen storage (UHS). A few commercial UHS facilities currently exist in the United States, including salt caverns owned and operated by Air Liquide, Linde, and Conoco Philips, but UHS is still a relatively new concept that has not been widely deployed. It is necessary to understand the safety risks and hazards associated with UHS before its use can be expanded and accepted more broadly. Many of these risks are addressed through regulations, codes, and standards (RCS) issued by governing bodies and organizations with expertise in certain hazards. This report is a review of RCS documents relevant to UHS, with a particular lens on potential technical gaps in existing guidance. These gaps may be specific to the physical properties of hydrogen or due to the different technologies relevant for hydrogen vs. natural gas storage. This is meant to be a high-level review to identify relevant documents and potential gaps. Formally addressing the individual gaps identified here within the codes and standards themselves would involve a more intensive analysis and differ based on the code or standard revision processes of the various publishing organizations. Therefore, presenting specific recommendations for revising the verbiage of the documents for UHS applications is left for future work and other publications.

08 HYDROGEN↗

Economically Viable Intermediate to Long Duration Hydrogen Energy Storage Solutions for Fossil Fueled Assets

This report was prepared as an account of work sponsored by the Office of Fossil Energy and Carbon Management of U.S. Department of Energy under Funding Opportunity Announcement Number DE-FOA-0002332 “Energy Storage for Fossil Power Generation”. The work aimed to explore and advance an innovative hydrogen energy storage system – the synergistically integrated hydrogen energy storage system (SIHES) – that has the following characteristics: • Compatible with existing or new coal and gas fuel electricity generation units, • best suited for intermediate to long duration energy storage, from 12 hours to weeks even months, and • capable of storing energy at the utility scale – hundreds of MWh to GWh energy storage with power output level in tens to hundreds of MW. Preliminary front-end engineering design (Pre-FEED) studies was carried out to develop and refine a site-specific SIHES as peaking power generation units (so named as HyPeaker) as the first market entry point, to demonstrate both the technical feasibility and the economic viability to integrate the HyPeaker “within the fence” of a fossil power plant. This specific site was TVA’s Johnsonville Combustion Turbine Plant. The HyPeaker was designed and engineered to integrate with a 60MW aeroderivative gas turbine unit already available at TVA’s Johnsonville site. This site-specific HyPeaker consists of an alkaline electrolyzer to produce hydrogen from CO 2 free electricity sources, an innovative low-cost high-pressure hydrogen storage system (Big-Ton) and the aero gas turbine to generate electricity using blend of hydrogen and natural gas. A holistic system level technoeconomic analysis tool specific to HyPeaker was developed to optimize the engineering design of the Johnsonville site-specific HyPeaker for cost and performance. The optimal design and specification of the Johnsonville site-specific HyPeaker are the following: • Alkaline electrolyzer: 3MW • Big-Ton storage vessel: 11,000kg H 2 at 3000psi. • 4-stage diaphragm hydrogen compressor: 55kg-H 2 /hr from 150psi to 3000psi. The HyPeaker is designed to provide sufficient hydrogen for 90% continuous operation of the HyPeaker. All major components have design life of 30 years. The capex of HyPeaker is estimated at $\$$7.1M. This included $\$$1.5M for the electrolyzer, $\$$5.6M for the storage vessel and compressor. The cost of aero gas turbine was included as it is already available at the site. Key findings are: • HyPeaker can be designed, manufactured, installed and integrated with the fossil power plants, with sub-systems and components commercially available on the market today, even when it is scaled up to an order of magnitude larger than the one at the Johnsonville site. HyPeaker is a technologically viable solution to cover a wide range of energy storage duration needs, from daily peaking operation to seasonal shifting for fossil fueled assets. • The cost advantage of SCCV based Big-Ton H 2 storage vessel made it possible to “oversize” the H 2 storage subsystem to achieve overall system level cost optimization. The benefits are two-fold. First, it allows to significantly reduce the capacity and cost of electrolyzer by spreading H 2 production over a much longer period of time when the fuel cost for electricity production is low. Second, it allows to balance the hydrogen production and usage shift over weeks to months to meet the peak demands. As such, the capital cost of HyPeaker system using the Big-Ton was less than half of the cost of a system with today’s steel tube based H 2 storage system. The HyPeaker has even better cost advantage Li-ion battery based energy storage system. The estimated capital cost of Li-Ion battery system would be at $\$$38M, under the same projected 20-year electricity generation profile of the Johnsonville site. This is over 5 times more expensive than the HyPeaker system. • Since industry scale energy storage systems do not have 100% energy conversion and storage efficiency, energy storage systems using fossil fuel generated electricity would increase the CO 2 emission. This is particularly the case for HyPeaker due to its low round trip efficiency. Therefore, a more sensible solution would be to the excessive or curtailed electricity from CO 2 emission free sources such as solar farms, wind farms or nuclear power plants, to produce hydrogen, and integrate them with the HyPeaker. Electricity from TVA’s nuclear power plants was used for the Johnsonville HyPeaker. • The economic viability of HyPeaker is expected to be further improved when global supply chains are taken into consideration. For the same Johnsonville site specific HyPeaker, the capex would be reduced to ~$\$$3.6M from ~$\$$7.1M, and the added LCOE is reduced to ~$\$$85/MWh. With the bipartisan Infrastructure Investment and Jobs Act, the cost of domestically produced HyPeaker sub-systems would be at the level of today’s global suppliers. Since the peaking units generally operate at peak usage period, thereby demanding higher price, the projected $\$$85/MWh LCOE would be within the realm of financial viability for utility operators.

08 HYDROGEN↗