Search NASA⌕ Search

SEARCH · Search NASA

Results for “STRAIN GAUGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

STS-96 FD Highlights and Crew Activities Report: Flight Day 07

On this seventh day of the STS-96 Discovery mission, the flight crew, Commander Kent V. Rominger, Pilot Rick D. Husband, and Mission Specialists Ellen Ochoa, Tamara E. Jernigan, Daniel T. Barry, Julie Payette, and Valery Ivanovich Tokarev are seen completing the transfer of material and equipment to the International Space Station. The astronauts install parts of a wireless strain gauge system, clean filters and check smoke detectors. The crew participates in a variety of news conferences with media representatives. Payette accepts a congratulatory call from Canadian Prime Minister Jean Chretien and answers questions from schoolchildren in Ottawa.

Source record↗

STS-96 Mission Highlights

In this second part of a three-part video mission-highlights set, on-orbit spacecrew activities performed on the STS-96 Space Shuttle Orbiter Discovery and the International Space Station are reviewed. The flight crew consists of Kent V. Rominger, Commander; Rick D. Husband, Pilot; and Mission Specialists Ellen Ochoa, Tamara E. Jernigan, Daniel T. Barry, Julie Payette (Canadian), and Valery Ivanovich Tokarev (Russian). The primary goals of this mission were to work on logistics and resupply the International Space Station. This second part in the mission series features video from Flight Day 4-7 (FD 4-7). FD 4 of STS-96 presents astronauts Tammy Jernigan and Dan Barry completing the second longest space walk in shuttle history. Footage includes Jernigan and Barry transferring and installing two cranes from the shuttle's payload bay to locations on the outside of the station. The astronauts enter the International Space Station delivering supplies and prepare the outpost to receive its first resident crew, scheduled to arrive in early 2000 on FD 5. The video also captures the crew involved in logistics transfer activities within the Discovery/ISS orbiting complex. FD 6 includes footage of Valery Tokarev and Canadian astronaut Julie Payette charging out the final six battery recharge controller units for two of Zarya's power-producing batteries and all crew members' involvement in logistics transfer activities from the SPACEHAB module to designated locations in the International Space Station. With the transfer work of FD 6 all but complete, the astronauts conduct some additional work, installing parts of a wireless strain gauge system that will help engineers track the effects of adding modules to the station throughout its assembly. Moving the few remaining items from Discovery to the ISS, then closing a series of hatches within the station's modules leading back to the shuttle are the primary activities contained in FD 7. Final coverage features Discovery's astronauts finishing their work inside the International Space Station, closing all of the hatches and readying the shuttle's small thrusters to be fired to raise the entire complex's orbit in preparation for the undocking and departure set for FD 8.

Source record↗

Experimental Results of the 2.7% Reference H Nacelle Airframe Interference High Speed Civil Transport Model

Experiments were conducted in the NASA Ames 9-Ft by 7-Ft Supersonic and 11-Ft by 11-Ft Transonic Wind Tunnels of a 2.7% Reference H (Ref. H) Nacelle Airframe Interference (NAI) High Speed Civil Transport (HSCT) model. NASA Ames did the experiment with the cooperation and assistance of Boeing and McDonnell Douglas. The Ref. H geometry was designed by Boeing. The model was built and tested by NASA under a license agreement with Boeing. Detailed forces and pressures of individual components of the configuration were obtained to assess nacelle airframe interference through the transonic and supersonic flight regime. The test apparatus was capable of measuring forces and pressures of the Wing body (WB) and nacelles. Axisymmetric and 2-D inlet nacelles were tested with the WB in both the in-proximity and captive mode. The in-proximity nacelles were mounted to a nacelle support system apparatus and were individually positioned. The right hand nacelles were force instrumented with flow through strain-gauged balances and the left hand nacelles were pressure instrumented. Mass flow ratio was varied to get steady state inlet unstart data. In addition, supersonic spillage data was taken by testing the 2-D inlet nacelles with ramps and the axisymmetric inlet nacelles with an inlet centerbody for the Mach condition of interest. The captive nacelles, both axisymmetric and 2-D, were attached to the WB via diverters. The captive 2-D inlet nacelle was also tested with ramps to get supersonic spillage data. Boeing analyzed the data and showed a drag penalty of four drag counts for the 2-D compared with the axisymmetric inlet nacelle. Two of the four counts were attributable to the external bevel designed into the 2-D inlet contour. Boeing and McDonnell Douglas used these data for evaluating Computational Fluid Dynamic (CFD) codes and for evaluation of nacelle airframe integration problems and solutions.

Cappuccio, Gelsomina↗

Multimodality Instrument for Tissue Characterization

A system with multimodality instrument for tissue identification includes a computer-controlled motor driven heuristic probe with a multisensory tip is discussed. For neurosurgical applications, the instrument is mounted on a stereotactic frame for the probe to penetrate the brain in a precisely controlled fashion. The resistance of the brain tissue being penetrated is continually monitored by a miniaturized strain gauge attached to the probe tip. Other modality sensors may be mounted near the probe tip to provide real-time tissue characterizations and the ability to detect the proximity of blood vessels, thus eliminating errors normally associated with registration of pre-operative scans, tissue swelling, elastic tissue deformation, human judgement, etc., and rendering surgical procedures safer, more accurate, and efficient. A neural network, program adaptively learns the information on resistance and other characteristic features of normal brain tissue during the surgery and provides near real-time modeling. A fuzzy logic interface to the neural network program incorporates expert medical knowledge in the learning process. Identification of abnormal brain tissue is determined by the detection of change and comparison with previously learned models of abnormal brain tissues. The operation of the instrument is controlled through a user friendly graphical interface. Patient data is presented in a 3D stereographics display. Acoustic feedback of selected information may optionally be provided. Upon detection of the close proximity to blood vessels or abnormal brain tissue, the computer-controlled motor immediately stops probe penetration.

Mah, Robert W.↗

Fluid Redistribution and Heart Rate in Humans During Whole-Body Tilting, G(z) Centrifugation, and Lower Body Negative Pressure

Gravity creates blood pressure gradients which redistribute body fluids towards the feet. Positive G(z) centrifugation and lower body negative pressure (LBNP) have been proposed to simulate these and other effects of gravity during long-term existence in microgravity. We hypothesized that the magnitude of upper-to-lower body fluid redistribution would increase according to the following order: short-arm centrifugation (SAC), long-arm centrifugation (LAC), head-up tilt (HUT), and LBNP. To test this hypothesis, we employed strain gauge plethysmography of the neck, thigh and calf during HUT and supine SAC and LAC up to lG(z) at the feet, and during supine LBNP to 100 mm Hg. Supine 100 mm Hg LBNP generates footward force and produces transmural blood pressures in the foot approximately equal to 1 G(z) (90 deg) HUT. Heart rate was measured via cardiotachometry. Control measurements were made while supine. SAC and LAC elicited similar increases in thigh volume at 1 G(z) (2.3 +/- 0.4 and 2.1 +/- 0.1%, respectively; mean +/- se, n greater than or equal to 7). At 100 mm Hg LBNP, thigh volume increased (3.4 +/- 0.3%) significantly more than during l G(z) centrifugation (p less than 0.05). Surprisingly, due to a paradoxical 0.6% reduction of thigh volume between 0.8 and 1.0 G(z) HUT, thigh volume was increased only 0.6 +/- 0.3% at 1 G(z) HUT. The calf demonstrated similar, although less definitive, responses to the various gravitational stimuli. Neck volume tended to decrease less during HUT than during the other stimuli. Heart rate increased similarly during HUT (18 +/- 2 beats/min) and LAC (12 +/- 2 beats/min), and exhibited still greater elevation during LBNP (29 +/- 4 beats/min), yet did not increase during SAC. These results suggest upright posture activates mechanisms that counteract footward fluid redistribution which are not activated during supine applications of simulated gravity. LAC more closely approximated effects of normal gravity (HUT) than LBNP. Therefore, when considering LBNP to simulate gravity, these findings support efforts to reduce the cardiovascular stress imposed by LBNP, while preserving the gravity-like force generated by LBNP.

Watenpaugh, D. E.↗

Calf Venous Compliance in Supine Posture Equals that Measured with Head-up Tilt

Calf venous compliance is measured conventionally with venous occlusion, where compliance equals calf volume elevation per mmHg thigh occlusion pressure in relaxed legs of supine subjects. Compliance may also be measured during stepwise head-up tilt (HUT) as calf volume elevation per mmHg gravitational venous pressure elevation produced by HUT. Although HUT on a tilt table with a footplate activates calf muscles which could reduce compliance, this muscle activation is relatively small (less than or = 10% of maximal voluntary levels). Therefore, we hypothesized that calf compliance measured with HUT equals that measured with conventional supine venous occlusion. The venous occlusion protocol consisted of 20, 40, 60 and 80 mmHg thigh cuff inflations held for 1, 2, 3 and 4 min, respectively, in 14 supine subjects. One min of cuff deflation to 0 mmHg separated occlusions. Nine other subjects underwent HUT through the following angles held for 30s each: -12 deg., -6 deg., 0 deg., 12 deg., 30 deg., 54 deg., and 90 deg. HUT calf venous pressure data were interpolated from Katkov and Chestukhin; these data correspond to 70-80% of calculated calf venous pressure changes (pgh). Liquid metal-in-silastic strain gauges measured calf volume for both venous occlusion and HUT compliance. Relaxed calf compliance in supine subjects equaled 4.6 +/- 0.4 ml/mmHg (X +/- SE), as measured with venous occlusion. Calf compliance during HUT equaled 4.6 +/- 1.0 ml/mmHg. Therefore, calf compliance in supine, relaxed subjects equals that measured during head-up tilt. We conclude that the minimal calf muscle activation which occurs during HUT does not importantly affect calf compliance.

Watenpaugh, Donald E.↗

Inducer Hydrodynamic Load Measurement Devices

Marshall Space Flight Center (MSFC) has demonstrated two measurement devices for sensing and resolving the hydrodynamic loads on fluid machinery. The first - a derivative of the six-component wind tunnel balance - senses the forces and moments on the rotating device through a weakened shaft section instrumented with a series of strain gauges. This rotating balance was designed to directly measure the steady and unsteady hydrodynamic loads on an inducer, thereby defining both the amplitude and frequency content associated with operating in various cavitation modes. The second device - a high frequency response pressure transducer surface mounted on a rotating component - was merely an extension of existing technology for application in water. MSFC has recently completed experimental evaluations of both the rotating balance and surface-mount transducers in a water test loop. The measurement bandwidth of the rotating balance was severely limited by the relative flexibility of the device itself, resulting in an unexpectedly low structural bending mode and invalidating the higher-frequency response data. Despite these limitations, measurements confirmed that the integrated loads on the four-bladed inducer respond to both cavitation intensity and cavitation phenomena. Likewise, the surface-mount pressure transducers were subjected to a range of temperatures and flow conditions in a non-rotating environment to record bias shifts and transfer functions between the transducers and a reference device. The pressure transducer static performance was within manufacturer's specifications and dynamic response accurately followed that of the reference.

Skelley, Stephen E.↗

Inducer Hydrodynamic Load Measurement Devices

Marshall Space Flight Center (MSFC) has demonstrated two measurement devices for sensing and resolving the hydrodynamic loads on fluid machinery. The first - a derivative of the six component wind tunnel balance - senses the forces and moments on the rotating device through a weakened shaft section instrumented with a series of strain gauges. This "rotating balance" was designed to directly measure the steady and unsteady hydrodynamic loads on an inducer, thereby defining both the amplitude and frequency content associated with operating in various cavitation modes. The second device - a high frequency response pressure transducer surface mounted on a rotating component - was merely an extension of existing technology for application in water. MSFC has recently completed experimental evaluations of both the rotating balance and surface-mount transducers in a water test loop. The measurement bandwidth of the rotating balance was severely limited by the relative flexibility of the device itself, resulting in an unexpectedly low structural bending mode and invalidating the higher frequency response data. Despite these limitations, measurements confirmed that the integrated loads on the four-bladed inducer respond to both cavitation intensity and cavitation phenomena. Likewise, the surface-mount pressure transducers were subjected to a range of temperatures and flow conditions in a non-rotating environment to record bias shifts and transfer functions between the transducers and a reference device. The pressure transducer static performance was within manufacturer's specifications and dynamic response accurately followed that of the reference.

Skelley, Stephen E.↗

Balance System

TherEx Inc.'s AT-1 Computerized Ataxiameter precisely evaluates posture and balance disturbances that commonly accompany neurological and musculoskeletal disorders. Complete system includes two-strain gauged footplates, signal conditioning circuitry, a computer monitor, printer and a stand-alone tiltable balance platform. AT-1 serves as assessment tool, treatment monitor, and rehabilitation training device. It allows clinician to document quantitatively the outcome of treatment and analyze data over time to develop outcome standards for several classifications of patients. It can evaluate specifically the effects of surgery, drug treatment, physical therapy or prosthetic devices.

Source record↗

Damage Detection Using Holography and Interferometry

This paper reviews classical approaches to damage detection using laser holography and interferometry. The paper then details the modern uses of electronic holography and neural-net-processed characteristic patterns to detect structural damage. The design of the neural networks and the preparation of the training sets are discussed. The use of a technique to optimize the training sets, called folding, is explained. Then a training procedure is detailed that uses the holography-measured vibration modes of the undamaged structures to impart damage-detection sensitivity to the neural networks. The inspections of an optical strain gauge mounting plate and an International Space Station cold plate are presented as examples.

Decker, Arthur J.↗

The Integration of Fieldbus Devices to an Existing DCS

Existing analog strain gauge transducers and signal conditioners were replaced with new Foundation Fieldbus Transmitters in the Distributed Control System, DCS, at the NASA Glenn Research Center (GRC). The reasons for implementing this upgrade and an evaluation of the results of the project are the subjects of this paper. Problems and advantages with the original transducers and the newly installed transmitters are described and compared. Detail of the physical network layer between the Foundation Fieldbus Transmitters, Programmable Logic Controllers (PLCs), Multipurpose Micro-Processor (MMPs) and the operator workstations are illustrated. The complex nature of the facility and methods of future control of the associated processes are also discussed.

Sadhukhan, Debashis↗

Linear and Nonlinear Analyses of a Wind-Tunnel Balance

The NASA Langley Research Center (LaRC) has been designing strain-gauge balances for utilization in wind tunnels since its inception. The utilization of balances span a wide variety of aerodynamic tests. A force balance is an inherently critically stressed component due to the requirements of measurement sensitivity. Force balance stress analysis and acceptance criteria are under review due to LaRC wind tunnel operational safety requirements. This paper presents some of the analyses done at NASA LaRC. Research and analyses were performed in order to investigate the structural integrity of the balances and better understand their performance. The analyses presented in this paper are helpful in understanding the overall behavior of an existing balance and can also be used in design of new balances to enhance their performance. As a first step, maximum load combination is used for linear structural analysis. When nonlinear effects are encountered, the analysis is extended to include the nonlinearities. Balance 1621 is typical for LaRC designed balances and was chosen for this study due to its traditional high load capacity, Figure 1. Maximum loading occurs when all 6 components are applied simultaneously with their maximum value allowed (limit load). This circumstance normally will not occur in the wind tunnel. However, if it occurs, is the balance capable of handling the loads with an acceptable factor of safety? Preliminary analysis using Pro/Mechanica indicated that this balance might experience nonlinearity. It was decided to analyze this balance by using NASTRAN so that a nonlinear analysis could be conducted. Balance 1621 was modeled and meshed in PATRAN for analysis in NASTRAN. The model from PATRAN/NASTRAN is compared to the one from Pro/Mechanica. For a complete analysis, it is necessary to consider all the load cases as well as use a dense mesh near all the edges. Because of computer limitations, it is not feasible to analyze model with the dense mesh near all edges. In the present study, the dense mesh is limited to the surface on the end of the axial sections.

Karkehabadi, R.↗

Inducer Hydrodynamic Forces in a Cavitating Environment

Marshall Space Flight Center has developed and demonstrated a measurement device for sensing and resolving the hydrodynamic loads on fluid machinery. The device - a derivative of the six-component wind tunnel balance - senses the forces and moments on the rotating device through a weakened shaft section instrumented with a series of strain gauges. This rotating balance was designed to directly measure the steady and unsteady hydrodynamic loads on an inducer, thereby defining the amplitude and frequency content associated with operating in various cavitation modes. The rotating balance was calibrated statically using a dead-weight load system in order to generate the 6 x 12 calibration matrix later used to convert measured voltages to engineering units. Structural modeling suggested that the rotating assembly first bending mode would be significantly reduced with the balance s inclusion. This reduction in structural stiffness was later confirmed experimentally with a hammer-impact test. This effect, coupled with the relatively large damping associated with the rotating balance waterproofing material, limited the device s bandwidth to approximately 50 Hertz Other pre-test validations included sensing the test article rotating assembly built-in imbalance for two configurations and directly measuring the assembly mass and buoyancy while submerged under water. Both tests matched predictions and confirmed the device s sensitivity while stationary and rotating. The rotating balance was then demonstrated in a water test of a full-scale Space Shuttle Main Engine high-pressure liquid oxygen pump inducer. Experimental data was collected a scaled operating conditions at three flow coefficients across a range of cavitation numbers for the single inducer geometry and radial clearance. Two distinct cavitation modes were observed symmetric tip vortex cavitation and alternate-blade cavitation. Although previous experimental tests on the same inducer demonstrated two additional cavitation modes at lower inlet pressures, these conditions proved unreachable with the rotating balance installed due to the intense dynamic environment. The sensed radial load was less influenced by flow coefficient than by cavitation number or cavitation mode although the flow coefficient range was relatively narrow. Transition from symmetric tip vortex to alternate-blade cavitation corresponded to changes in both radial load magnitude and radial load orientation relative to the inducer. Sensed moments indicated that the effective load center moved downstream during this change in cavitation mode. An occurrence of "higher+rdex cavitation" was also detected in both the stationary pressures and the rotating balance data although the frequency of the phenomena was well above the reliable bandwidth of the rotating balance. In summary the experimental tests proved both the concept and device s capability despite the limitations and confirmed that hydrodynamically-induced forces and moments develop in response to the unbalanced pressure field, which is, in turn, a product of the cavitation environment.

Skelley, Stephen E.↗

Heterogeneous responses of human limbs to infused adrenergic agonists: a gravitational effect?

Unlike quadrupeds, the legs of humans are regularly exposed to elevated pressures relative to the arms. We hypothesized that this "dependent hypertension" would be associated with altered adrenergic responsiveness. Isoproterenol (0.75-24 ng x 100 ml limb volume-1 x min-1) and phenylephrine (0.025-0.8 microg x 100 ml limb volume-1 x min-1) were infused incrementally in the brachial and femoral arteries of 12 normal volunteers; changes in limb blood flow were quantified by using strain-gauge plethysmography. Compared with the forearm, baseline calf vascular resistance was greater (38.8 +/- 2.5 vs. 26.9 +/- 2.0 mmHg x 100 ml x min x ml-1; P < 0.001) and maximal conductance was lower (46.1 +/- 11.9 vs. 59.4 +/- 13.4 ml x ml-1 x min-1 x mmHg-1; P < 0.03). Vascular conductance did not differ between the two limbs during isoproterenol infusions, whereas decreases in vascular conductance were greater in the calf than the forearm during phenylephrine infusions (P < 0.001). With responses normalized to maximal conductance, the half-maximal response for phenylephrine was significantly less for the calf than the forearm (P < 0.001), whereas the half-maximal response for isoproterenol did not differ between limbs. We conclude that alpha1- but not beta-adrenergic-receptor responsiveness in human limbs is nonuniform. The relatively greater response to alpha1-adrenergic-receptor stimulation in the calf may represent an adaptive mechanism that limits blood pooling and capillary filtration in the legs during standing.

Clinical Trial↗

Mechanisms of action of light on circadian rhythms in the monkey

Light is considered by many investigators to be the primary Zeitgeber for most physiologic rhythms. In order to study the effects on biorhythms of changing photoperiods and to provide information on the nature of the wave forms and the mechanisms of entrainment, unrestrained male monkeys (Cebus albifrons, Macaca nemestrina) were maintained in a sound-proofed environmental chamber. The Cebus was initially maintained on a 12L:12D schedule; it was subjected to a 180 degrees phase shift for 14 days, then returned to the original photoperiod. In two experiments (24 days; 27 days each) the same monkey was again maintained on a 12L:12D schedule which was gradually altered to a constant light environment. Deep body temperature (DBT) data were obtained with miniature radiotransmitters. Locomotor activity (LMA) was measured by strain gauges. Under the 12L:12D regimens the Macaca DBT cycles were uniform as to phase and wave form for over 60 weeks. These wave forms were analyzed by the use of periodogram and correlogram analyses and by fitting to the Volterra Integro-Differential Equation. Phase angle relationships between Zeitgeber and physiologic parameters were characterized. After the photoperiod phase shift the DBT cycle rephased in about 9 days. During the rephasing process the wave form changed. The shapes of the wave forms of DBT and activity were maintained with increasing light until an 18L:6D photoperiod was reached. The rhythms were entrained to the onset of darkness rather than lights on. Major and minor periods of LMA were detected. Hysteresis diagrams showed that DBT led the onset of major LA by 6 hr and the end of major activity by 2 hr.

Light↗

Supine exercise during lower body negative pressure effectively simulates upright exercise in normal gravity

Exercise within a lower body negative pressure (LBNP) chamber in supine posture was compared with similar exercise against Earth's gravity (without LBNP) in upright posture in nine healthy male volunteers. We measured footward force with a force plate, pressure in soleus and tibialis anterior muscles of the leg with transducer-tipped catheters, calf volume by strain gauge plethysmography, heart rate, and systolic and diastolic blood pressures during two conditions: 1) exercise in supine posture within an LBNP chamber during 100-mmHg LBNP (exercise-LBNP) and 2) exercise in upright posture against Earth's gravity without LBNP (exercise-1 G). Subjects exercised their ankle joints (dorsi- and plantarflexions) for 5 min during exercise-LBNP and for 5 min during exercise-1 G. Mean footward force produced during exercise-LBNP (743 +/- 37 N) was similar to that produced during exercise-1 G (701 +/- 24 N). Peak contraction pressure in the antigravity soleus muscle during exercise-LBNP (115 +/- 10 mmHg) was also similar to that during exercise-1 G (103 +/- 13 mmHg). Calf volume increased significantly by 3.3 +/- 0.5% during exercise-LBNP compared with baseline values. Calf volume did not increase significantly during exercise-1 G. Heart rate was significantly higher during exercise-LBNP (99 +/- 5 beats/min) than during exercise-1 G (81 +/- 3 beats/min). These results indicate that exercise in supine posture within an LBNP chamber can produce similar musculoskeletal stress in the legs and greater systemic cardiovascular stress than exercise in the upright posture against Earth's gravity.

NASA Center ARC↗

Distributed Sensing of Composite Over-wrapped Pressure Vessel Using Fiber-Bragg Gratings at Ambient and Cryogenic Temperatures

Fiber Bragg gratings are use to monitor the structural properties of composite pressure vessels. These gratings optically inscribed into the core of a single mode fiber are used as a tool to monitor the stress strain relation in laminate structure. The fiber Bragg sensors are both embedded within the composite laminates and bonded to the surface of the vessel with varying orientations with respect to the carbon fiber in the epoxy matrix. The response of these fiber-optic sensors is investigated by pressurizing the cylinder up to its burst pressure of around 2800 psi. This is done at both ambient and cryogenic temperatures using water and liquid nitrogen. The recorded response is compared with the response from conventional strain gauge also present on the vessel. Additionally, several vessels were tested that had been damaged to simulate different type of events, such as cut tow, delimitation and impact damage.

Grant, Joseph↗

Distributed sensing of Composite Over-wrapped Pressure Vessel using Fiber-Bragg Gratings at Ambient and Cryogenic Temperatures

Fiber Bragg gratings are use to monitor the structural properties of composite pressure vessels. These gratings optically inscribed into the core of a single mode fiber are used as a tool to monitor the stress strain relation in laminate structure. The fiber Bragg sensors are both embedded within the composite laminates and bonded to the surface of the vessel with varying orientations with respect to the carbon fiber in the epoxy matrix. The response of these fiber-optic sensors is investigated by pressurizing the cylinder up to its burst pressure of around 2800 psi. This is done at both ambient and cryogenic temperatures using water and liquid nitrogen. The recorded response is compared with the response from conventional strain gauge also present on the vessel. Additionally, several vessels were tested that had been damaged to simulate different type of events, such as cut tow, delimitation and impact damage.

Grant, Joseph↗