Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sampling device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Ultrafast (1‐5 sec) Lamination of Perovskite Solar Cells With Self‐Encapsulation Using Rapid Joule Heating

Perovskite solar cells (PSCs) are traditionally fabricated using sequential layer‐by‐layer deposition, in which each layer of the device is processed on top of the preceding layer. This constrains the processing techniques and selection of transport layer materials that can be used in the solar cell. To overcome these challenges, two half‐cells can be processed independently and then diffusion‐bonded through a lamination process. However, current lamination processes for perovskite solar cells suffer from relatively long process times, which can limit throughput when moving toward high‐volume manufacturing. In this study, a custom platform was designed for rapid‐joule heating of perovskite materials and devices. This enabled more than a 99% reduction in lamination time from 26 min to 1 s. Perovskite samples that were laminated in 1 s exhibited comparable values of percent bonded area, interfacial toughness, grain domain size, and X‐ray diffraction spectra to those laminated in greater than 10 min. As a proof‐of‐concept, 18.3% efficient devices were successfully laminated in 5 s. A transient heat transfer model was developed to describe the relationship between the perovskite temperature and the electrical power supplied to the heaters, establishing a baseline for predicting processing conditions in large‐scale manufacturing systems. Ultra‐fast lamination provides a pathway toward scalable roll‐to‐roll or sheet‐to‐sheet manufacturing of PSCs.

heat transfer↗

Precision Measurement of the Microwave Dielectric Loss of Sapphire in the Quantum Regime with Parts-per-Billion Sensitivity

Dielectric loss is known to limit state-of-the-art superconducting qubit lifetimes. Recent experiments imply upper bounds on bulk dielectric loss tangents on the order of 100 parts per billion but because these inferences are drawn from fully fabricated devices with many loss channels, these experiments do not definitely implicate or exonerate the dielectric. To resolve this ambiguity, we devise a measurement method capable of separating and resolving bulk dielectric loss with a sensitivity at the level of 5 ×10 –9 . The method, which we call the dielectric dipper, involves the in situ insertion of a dielectric sample into a high-quality microwave cavity mode. Smoothly varying the participation of the sample in the cavity mode enables a differential measurement of the dielectric loss tangent of the sample. The dielectric dipper can probe the low-power behavior of dielectrics at cryogenic temperatures and does so without the need for any lithographic process, enabling controlled comparisons of substrate materials and processing techniques. We demonstrate the method with measurements of sapphire grown by edge-defined film-fed growth (EFG) in comparison to high-grade sapphire grown by the heat-exchanger method (HEMEX). For EFG sapphire, we infer a bulk loss tangent of 63⁢(8) ×10 –9 and a substrate-air interface loss tangent of 15⁢(3) ×10 –4 (assuming a sample surface thickness of 3 nm). For a typical transmon, this bulk loss tangent would limit device quality factors to Q ≲20 ×10 6 , suggesting that bulk loss is likely the dominant loss mechanism in the longest-lived transmons on sapphire. We also demonstrate this method on HEMEX sapphire and bound its bulk loss tangent to be less than 19⁢(6) ×10 –9 . As this bound is about 3 times smaller than the bulk loss tangent of EFG sapphire, the use of HEMEX sapphire as a substrate would lift the bulk dielectric coherence limit of a typical transmon qubit to several milliseconds.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Atomic-resolution lithography with an on-chip scanning tunneling microscope

In this work, atomic-resolution lithography with a Microelectromechanical-System (MEMS) based Scanning Tunneling Microscope (STM) is demonstrated for the first time. The microscope consists of a commercial UltraHigh-Vacuum (UHV) STM whose regular tip is replaced with a 1-Degree-of-Freedom (1-DOF) MEMS nanopositioner. This results in a hybrid STM system where XY-plane motions are provided by the piezotube of the original system and Z-axis motion by the MEMS with a higher bandwidth. Sharp tips made of Pt or W are added to the MEMS devices with postfabrication techniques. With this hybrid system, STM-based lithography is demonstrated on an H-passivated Si (100)-2×1 sample under UHV condition. Results prove the capability of the hybrid STM system for atomic-scale lithography. This capability, paired with the small footprint of the MEMS device, makes this approach a candidate for building a high-throughput parallel STM lithography platform by incorporating an array of 1-DOF MEMS devices that perform lithography in parallel.

Alipour, Afshin (ORCID:0000000263252067)↗

Scale–Bridging in Three–Dimensional Fracture Networks: Characterizing the Effects of Variable Fracture Apertures on Network–Scale Flow Channelization

Here, we incorporate observations of real fracture aperture variability observed in laboratory experiments into an ensemble of three-dimensional discrete fracture network (DFN) simulations to characterize how variations of this micro-scale feature can influence flow and transport behavior at the network scale. A shear fracture is created within a Marcellus shale sample, and the fracture aperture is measured using a triaxial direct-shear device coupled with real-time X-ray imaging at in-situ stress conditions. We construct an ensemble of fracture networks based on natural fractures in Marcellus shale and project regions of the experimental aperture field onto each fracture in the networks. Our calculations demonstrate that the degree of flow channelization, a network-scale flow field structure, is dramatically increased by local changes in the aperture field that in turn affects flow and transport properties.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Development and Evaluation of a Cost-Effective Behind-the-Meter Synchronized Measurement Unit for Enhanced Grid Integration

This paper presents the development of the Inverter Based Resource Monitor (IBRM), an innovative behind-the-meter synchronized measurement unit (SMU) tailored for integration with inverter-based resources (IBRs). The IBRM distinguishes itself as a highly accurate and cost-effective SMU, offering facile deployment and connectivity to IBRs. It is equipped to conduct real-time voltage and current waveform analyses, serving as a phasor measurement unit (PMU) with exceptionally rapid synchrophasor transmission capabilities. The device incorporates a cutting-edge dual-core architecture designed to minimize sampling delays inherent to its microprocessor, thereby enhancing the precision of synchronized waveform measurements. Moreover, the IBRM is adept at recording high-fidelity waveform data, capturing nuances such as waveform distortions, high-order harmonics, and wide-band oscillations prevalent in power grids with substantial IBR presence. A prototype of the IBRM has been constructed and subjected to rigorous testing to assess its functional capabilities and measurement precision, utilizing both idealized signal generators and a real-world off-grid inverter setup as benchmarks.

Wu, Ori [ORNL] (ORCID:0000000326723410)↗

Performance of the AstroPix Prototype Module for the Barrel Imaging Calorimeter at the ePIC Detector and in Space-Based Payloads

AstroPix is a high-voltage CMOS (HV-CMOS) monolithic active pixel sensor originally developed to enable precision gamma-ray imaging and spectroscopy in the medium-energy regime (~100 keV–100 MeV) based on the groundwork laid by ATLASpix and MuPix. It features a 500 μm pixel pitch, in-pixel amplification and digitization, and low power consumption (~3-4 mW/cm2), making it scalable for large-area, multilayer telescope detector planes. The detectors have a designed dynamic range of 25 keV to 700 keV. With these features, AstroPix meets the requirements of future space-based high-energy telescopes and the imaging layers of the Barrel Imaging Calorimeter (BIC) in the Electron-Proton/Ion Collider (ePIC) detector at the future Electron-Ion Collider (EIC). For the space-based payload, AstroPix is being integrated into sounding rocket and balloon payloads to demonstrate the technical readiness of the devices. For BIC, AstroPix-based imaging layers interleaved within the lead/scintillating-fiber (Pb/SciFi) sampling calorimeter provide granular shower imaging, enabling key performance features such as electron/pion or gamma/neutral pion separation. As part of the ongoing detector R&D efforts, we have been testing various AstroPix_v3 configurations: the single chip, a quad-chip assembly, a three-layer stack of quad chips, and a 9-chip module that represents the smallest prototype unit of the BIC imaging layer. This presentation will highlight recent performance test results from these AstroPix detector configurations.

Kim, Bobae (ORCID:0000000295396815)↗

Influence of Resonances on the Noise Performance of SQUID Susceptometers

Scanning Superconducting Quantum Interference Device (SQUID) Susceptometry simultaneously images the local magnetic fields and susceptibilities above a sample with sub-micron spatial resolution. Further development of this technique requires a thorough understanding of the current, voltage, and flux ( I V Φ ) characteristics of scanning SQUID susceptometers. These sensors often have striking anomalies in their current–voltage characteristics, which we believe to be due to electromagnetic resonances. The effect of these resonances on the performance of these SQUIDs is unknown. To explore the origin and impact of the resonances, we develop a model that qualitatively reproduces the experimentally-determined I V Φ characteristics of our scanning SQUID susceptometers. We use this model to calculate the noise characteristics of SQUIDs of different designs. We find that the calculated ultimate flux noise is better in susceptometers with damping resistors that diminish the resonances than in susceptometers without damping resistors. Such calculations will enable the optimization of the signal-to-noise characteristics of scanning SQUID susceptometers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Device for residue handling minimization with vacuum-assisted separations

A device for collection of residue from separation columns. A manifold provides for multiple sample ports that are fluidly connected to a vacuum port by at least one channel. Residue from the separation columns is pulled through the sample ports, into the channel, and then to the vacuum port. From the vacuum port the residue can be moved, under the force of the vacuum, directly to a drain or to a collection vessel connected with a drain.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigation of properties of CdSeTe/Sb and Sb/CdSeTe stacks

The effect of Sb inclusion in CdSeTe thin films was examined. CdSeTe alloys were grown by co-evaporation, either on 5 nm thick electron-beam evaporated Sb layers (Sb/CdSeTe) or coated with Sb post-deposition (CdSeTe/Sb). Sb inclusion improved CdSeTe grain structure, a critical factor for device performance, with average grain size increasing from 0.6 to 1.5 μm. All samples crystallized on annealing to the cubic structure, with a change in film orientation from (111) to random or (220). The presence of Sb in CdSeTe/Sb or Sb/CdSeTe samples, however, had a limited effect on the carrier concentration compared to Sb-free samples. Time resolved photoluminescence showed Sb inclusion increased decay lifetimes, with τ1 = 0.8 ns for and τ2 = 6.9 ns for the Sb/CdSeTe sample.

14 SOLAR ENERGY↗

VitroJet: new features and case studies

Single-particle cryo-electron microscopy has become a widely adopted method in structural biology due to many recent technological advances in microscopes, detectors and image processing. Before being able to inspect a biological sample in an electron microscope, it needs to be deposited in a thin layer on a grid and rapidly frozen. The VitroJet was designed with this aim, as well as avoiding the delicate manual handling and transfer steps that occur during the conventional grid-preparation process. Since its creation, numerous technical developments have resulted in a device that is now widely utilized in multiple laboratories worldwide. It features plasma treatment, low-volume sample deposition through pin printing, optical ice-thickness measurement and cryofixation of pre-clipped Autogrids through jet vitrification. This paper presents recent technical improvements to the VitroJet and the benefits that it brings to the cryo-EM workflow. A wide variety of applications are shown: membrane proteins, nucleosomes, fatty-acid synthase, Tobacco mosaic virus, lipid nanoparticles, tick-borne encephalitis viruses and bacteriophages. These case studies illustrate the advancement of the VitroJet into an instrument that enables accurate control and reproducibility, demonstrating its suitability for time-efficient cryo-EM structure determination.

59 BASIC BIOLOGICAL SCIENCES↗

Three-Dimensional Mass Spectrometric Imaging of Biological Structures Using a Vacuum-Compatible Microfluidic Device

Three-dimensional (3D) molecular imaging of biological structures is important for a wide range of research. In recent decades, secondary ion mass spectrometry (SIMS) has been recognized as a powerful technique for both two-dimensional (2D) and 3D molecular imaging. Sample fixations (e. g., chemical fixation and cryogenic fixation methods) are necessary to adapt biological samples to the vacuum condition in the SIMS chamber, which has been demonstrated to be non-trivial and less controllable, thus limiting the wider application of SIMS on 3D molecular analysis of biological samples. Our group recently developed in situ liquid SIMS that offers great opportunities for the molecular study of various liquids and liquid interfaces. In this work, we demonstrate that a further development of the vacuum-compatible microfluidic device used in in situ liquid SIMS provides a convenient freeze-fixation of biological samples and leads to more controllable and convenient 3D molecular imaging. The special design of this new vacuum-compatible liquid chamber allows an easy determination of sputter rates of ice, which is critical for calibrating the depth scale of frozen biological samples. Sputter yield of a 20 keV Ar 1800 + ion on ice has been determined as 1500 (± 8%) water molecules per Ar 1800 + ion, consistent with our results from molecular dynamics simulations. Moreover, using the information of ice sputter yield, we successfully conduct 3D molecular imaging of frozen homogenized milk and observe network structures of interesting organic and inorganic species. Finally, taken together, our results will significantly benefit various research fields relying on 3D molecular imaging of biological structures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

First lithium experiments in HIDRA and evidence of helium retention during quasi-steady-state stellarator plasma operations

Recent experiments in Hybrid Illinois Device for Research and Applications (HIDRA) have had operational discharges between t discharge = 60 and 1000 s using electron cyclotron resonant heating (ECRH) of the plasma. This means that quasi-steady-state plasma discharges reach conditions to study long-pulse plasma material interactions (PMIs). The newly commissioned HIDRA-Material Analysis Test-stand PMI diagnostic is used to place a drop of lithium onto a heated tungsten surface, transfer the sample in-vacuo and expose it in a helium plasma. Helium is of interest as there is an open question to whether lithium will be able to remove helium ash in real fusion devices. The introduction of the W-Li sample in HIDRA resulted in evaporation of lithium into the helium plasma during a 600 s pulse and caused a reduction of over 90% in neutral pressure during the discharge. It was also observed that the plasma density and temperature increased by over 2.5 times. Using spectroscopy and a helium collisional radiative model, the peak temperature and density of the helium plasma can be monitored during the discharge. During lithium evaporation, as significant lithium ionization occurs, there is a 85% drop in the HIDRA vessel neutral pressure, despite a constant flow rate of He gas. This reduction in neutral pressure is supported by spectroscopy data with corresponding reductions in He I line intensities (587 nm, 667 nm, 706 nm, and 728 nm), as well as those of other impurities. At one point in the discharge a lithium plasma is created, as indicated by an increase in Li + emission and a complete reduction in He + emission, but the electron density jumps from ne = 3 × 10 18 m –3 to over ne = 8 × 10 18 m –3 while the core temperature stays relatively constant between Te = 16 eV and 20 eV. Once lithium has completely evaporated from the sample and the majority of the ionized lithium has diffused from the plasma to the vessel walls, pressure and spectroscopy data paired with He collisional radiative model calculations shows a re-establishment of a helium plasma in a low recycling regime. In this regime, the density drops down to ne = 2 × 10 18 m –3 and the electron temperature increases from T e = 20 eV to over T e = 50 eV indicating an increase in helium heating efficiency. This is also indicated by the He+ emission re-establishing and having a higher intensity. Here, we show the results from the first lithium campaign in HIDRA. In the presence of lithium, and in particular when lithium ions are present, the helium disappears from the plasma via an as of yet unknown complex relationship that needs to be further studied. The most likely explanation is that the lithium ions are distributed around the vessel and able to trap helium to the surface turning HIDRA into a large gettering surface. These results have potential implications on future plasma facing component design using liquid lithium for impurity and recycling control using limiters and divertors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Conceptual Design and Analysis of In-Vessel Components for the Materials Plasma Exposure eXperiment (MPEX)

The materials plasma exposure experiment (MPEX) is a linear plasma divertor simulator currently undergoing conceptual design. The facility will expose material samples to steady-state plasma fluxes to examine plasma–material interactions (PMIs) that are expected in the next generation of fusion devices. The plasmas will be generated by a helicon source, with electron and ion heating sources of up to 800 kW possible. The peak heat fluxes of the target are expected to be up to 10 MW/m 2 . The facility will be capable of handling low-activation neutron-irradiated samples in order to examine the multivariate effects of neutron damage and plasma fluence. Neutron-irradiated samples are planned to be roughly of 10-mm diameter; however, plasma-facing components up to 60×600 mm can be accommodated. The steady-state nature of the device will require the magnetic confinement of the plasma to be achieved with superconducting magnets, with a maximum on-axis field of 2.5 T. In addition, since MPEX will be a steady-state device, in-vessel components need to be water cooled. The primary in-vessel components will be the target, the dump plate, the limiter, the skimmers, and the microwave absorber. The conceptual design of these components is presented here, including analyses that confirm that the designs are adequate to meet the requirements of MPEX operation.

Lumsdaine, Arnold↗

Large-Grained Cylindrical Block Copolymer Morphologies by One-Step Room-Temperature Casting

We report a facile method of ordering block copolymer (BCP) morphologies in which the conventional two-step casting and annealing steps are replaced by a single-step process where microphase separation and grain coarsening are seamlessly integrated within the casting protocol. This is achieved by slowing down solvent evaporation during casting by introducing a non-volatile solvent into the BCP casting solution what effectively prolongs the duration of the grain-growth phase. We demonstrate the utility of this solvent evaporation annealing (SEA) method by producing well-ordered large molecular-weight BCP thin films in a total processing time shorter than 3 minutes without resorting to any extra laboratory equipment other than a basic casting-device i.e., spin- or blade-coater. By analyzing the morphologies of the quenched samples, we identify a relatively narrow range of polymer concentration in the wet film, just above the order-disorder concentration, to be critical for obtaining large-grained morphologies. This finding is corroborated by the analysis of the grain-growth kinetics of horizontally-oriented cylindrical domains where relatively large growth exponents (1/2) are observed, indicative of a more rapid defect-annihilation mechanism in the concentrated BCP solution than in thermally-annealed BCP melts. Furthermore, the analysis of temperature-resolved kinetics data allows us to calculate the Arrhenius activation energy of the grain-coarsening in this one-step BCP ordering process.

36 MATERIALS SCIENCE↗

Bayesian Optimization of a Free-Electron Laser

The Linac Coherent Light Source X-ray free-electron laser is a complex scienti c apparatus which changes con gurations multiple times per day, necessitating fast tuning strategies to reduce setup time for successive experiments. To this end, we employ a Bayesian approach to maximizing X- ray laser pulse energy by controlling groups of quadrupole magnets. A Gaussian process model provides probabilistic predictions for the machine response with respect to control parameters, enabling a balance of exploration and exploitation in the search for the global optimum. We show that the model parameters can be learned from archived scans, and correlations between devices can be extracted from the beam transport. Furthermore, the result is a sample-e cient optimization routine, combining both historical data and knowledge of accelerator physics to signi cantly outperform existing optimizers.

47 OTHER INSTRUMENTATION↗

Enabling Interoperable SCADA Communications for PV Inverters through Embedded Controllers

The percentage integration of photovoltaic (PV) inverters in the field has increased significantly in the past 5 years. Regardless of the size of the PV plants and the inverters (residential vs. commercial), it is becoming crucial that these devices have the capability to communicate with peers (other smart devices) and with components that are at a hierarchy above the inverters (e.g., supervisory control and data acquisition (SCADA) systems, distributed controllers, and data managers). This project aims to develop a standard SCADA software code for inverters’ embedded controllers that will enable interoperability with other components in the system. To achieve this, the code will be developed using two different protocols: Distributed Network Protocol 3 and International Electrotechnical Commission 61850. The developed code is aimed to be deployed in simple embedded controllers. It will be tested in the National Renewable Energy Laboratory’s (NREL’s) Energy Systems Integration Facility. The tested code will then be made available through Triangle MicroWorks’s (TMW’s) software platform. The primary objectives of this project include training the NREL team with TMW’s embedded controller libraries, developing an interoperable communication code for embedded controllers, successfully testing and deploying the code, and demonstrating the newly developed code in a conference.

14 SOLAR ENERGY↗

Semi-supervised Bayesian Low-shot Learning

Deep neural networks (NNs) typically outperform traditional machine learning (ML) approaches for complicated, non-linear tasks. It is expected that deep learning (DL) should offer superior performance for the important non-proliferation task of predicting explosive device configuration based upon observed optical signature, a task which human experts struggle with. However, supervised machine learning is difficult to apply in this mission space because most recorded signatures are not associated with the corresponding device description, or “truth labels.” This is challenging for NNs, which traditionally require many samples for strong performance. Semi-supervised learning (SSL), low-shot learning (LSL), and uncertainty quantification (UQ) for NNs are emerging approaches that could bridge the mission gaps of few labels and rare samples of importance. NN explainability techniques are important in gaining insight into the inferential feature importance of such a complex model. In this work, SSL, LSL, and UQ are merged into a single framework, a significant technical hurdle not previously demonstrated. Exponential Average Adversarial Training (EAAT) and Pairwise Neural Networks (PNNs) are chosen as the SSL and LSL methods of choice. Permutation feature importance (PFI) for functional data is used to provide explainability via the Variable importance Explainable Elastic Shape Analysis (VEESA) pipeline. A variety of uncertainty quantification approaches are explored: Bayesian Neural Networks (BNNs), ensemble methods, concrete dropout, and evidential deep learning. Two final approaches, one utilizing ensemble methods and one utilizing evidential learning, are constructed and compared using a well-quantified synthetic 2D dataset along with the DIRSIG Megascene.

97 MATHEMATICS AND COMPUTING↗

Investigating Bacterial-Fungal Interactions using Fungal Highway Columns in Diverse Environments and Substrates

Bacterial-fungal interactions (BFIs) play an integral role in shaping microbial community composition, biogeochemical functions, spatial dynamics, and microbial dispersal. Mycelial networks created by filamentous fungi or other filamentous microorganisms (e.g., Oomycetes) act as 'fungal highways' that can be utilized by bacteria for transport throughout heterogeneous environments, greatly facilitating their mobility and granting them access to regions that may be challenging or impossible to reach on their own (e.g., due to air pockets within the soil). Several devices and experimental protocols have been created to study these fungal highways, including fungal highway columns. The fungal highway column designed by our group can be used for a variety of in situ or in vitro applications, as well as with diverse environmental and host-associated sample types. Herein, we describe the methods for performing experiments with these columns, including designing, printing, sterilizing, and preparing the devices. The options for analyzing data obtained from the use of these devices are also discussed here, and troubleshooting advice regarding potential pitfalls associated with experiments using fungal highway columns is offered. These devices can be used to gain a more comprehensive understanding of the diversity, mechanisms, and dynamics of fungal highway BFIs to provide valuable insights into the structural and functional dynamics within complex environments (e.g., soils) and across diverse habitats in which bacteria and fungi co-exist.

59 BASIC BIOLOGICAL SCIENCES↗