Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scanning techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Johnson-noise-limited cancellation-free microwave impedance microscopy with monolithic silicon cantilever probes

Abstract Microwave impedance microscopy (MIM) is an emerging scanning probe technique for nanoscale complex permittivity mapping and has made significant impacts in diverse fields. To date, the most significant hurdles that limit its widespread use are the requirements of specialized microwave probes and high-precision cancellation circuits. Here, we show that forgoing both elements not only is feasible but also enhances performance. Using monolithic silicon cantilever probes and a cancellation-free architecture, we demonstrate Johnson-noise-limited, drift-free MIM operation with 15 nm spatial resolution, minimal topography crosstalk, and an unprecedented sensitivity of 0.26 zF/ √ Hz. We accomplish this by taking advantage of the high mechanical resonant frequency and spatial resolution of silicon probes, the inherent common-mode phase noise rejection of self-referenced homodyne detection, and the exceptional stability of the streamlined architecture. Our approach makes MIM drastically more accessible and paves the way for advanced operation modes as well as integration with complementary techniques.

47 OTHER INSTRUMENTATION↗

Three-dimensional structure of self-excited dust density waves under microgravity conditions

Self-excited dust density waves in a dusty plasma, containing micrometer-sized particles, have been observed under microgravity conditions at low gas pressures and high dust densities. The waves emerge spontaneously and propagate from the void edge radially outwards to the plasma boundary. We found that the wave propagates obliquely to the local ion flow in regions with high electric fields close to the sheath, whereas it propagates parallel in the plasma bulk. So far the observation was limited to a fixed two-dimensional section through the discharge volume. Recent experiments were performed on parabolic flights in a parallel plate rf discharge, which used the technique of scanning video microscopy. This technique utilizes the high temporal coherence of the waves to reconstruct their full three-dimensional structure. The analysis yields a surprising global spatial coherence of the wave phenomenon.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The role of Sr doping on structure and microstructural properties of LaFeO{sub 3}

The doping of Strontium in LaFeO{sub 3} and its influence on the structural and microstructure properties were studied thoroughly. A few sets of Sr doping in La{sub (1-x)}Fe{sub x}O{sub 3}, where x=0.00, 0.02, and 0.06 were made through the solution combustion synthesis method using urea as fuel. X-ray diffraction was applied to get information about the structure and purity. The Rietveld refinement on X-ray diffraction peaks have been done, in order to calculate various structural parameters. The morphology of La{sub (1-x)}Sr{sub x}FeO{sub 3} nanoscale particles has been confirmed by field emission scanning electron microscopy (FESEM) technique. Differential scanning calorimetry (DSC) signals demonstrated the antiferromagnetic to paramagnetic transition (T{sub N}). The FTIR spectra was provided the information about various vibration modes in samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Imaging the flow of holes from a collimating contact in graphene

A beam of holes formed in graphene by a collimating contact is imaged using a liquid-He cooled scanning probe microscope (SPM). The mean free path of holes is greater than the device dimensions. A zigzag shaped pattern on both sides of the collimating contact absorbs holes that enter at large angles. The image charge beneath the SPM tip defects holes, and the pattern of flow is imaged by displaying the change in conductance between contacts on opposite sides, as the tip is raster scanned across the sample. Collimation is confirmed by bending hole trajectories away from the receiving contact with an applied magnetic field. The SPM images agree well with ray-tracing simulations.

36 MATERIALS SCIENCE↗

Molecular-Level Insights into Photocatalysis from Scanning Probe Microscopy Studies on TiO2(110)

The field of heterogeneous photocatalysis has grown considerably in the decades since Fujishima and Honda's ground-breaking publications of photoelectrochemistry on TiO2. Numerous review articles continue to point to both progress made in the use of heterogeneous materials (such as TiO2) to perform photoconversion processes, and the many opportunities and challenges in heterogeneous photocatalysis research such as solar energy conversion and environmental remediation. The past decade has also seen an increase in the use of molecular-level approaches applied to model single crystal surfaces in an effort to obtain new insights into photocatalytic phenomena. In particular, scanning probe techniques (SPM) have enabled researchers to take a ‘nanoscale’ approach to photocatalysis that includes interrogation of the reactivities of specific sites and adsorbates on a model photocatalyst surface. The rutile TiO2(110) surface has become the prototypical oxide single crystal surface for fundamental studies of many interfacial phenomena. In particular, TiO2(110) has become an excellent model surface for probing photochemical and photocatalytic reactions at the molecular level. A variety of experimental approaches have emerged as being ideally suited for studying photochemical reactions on TiO2(110), including desorption-oriented approaches and electronic spectroscopies, but perhaps the most promising techniques for evaluating site-specific properties are those of SPM. In this review, we highlight the growing use of SPM techniques in providing molecular-level insights into surface photochemistry on the model photocatalyst surface of rutile TiO2(110). Our objective is to both illustrate the unique knowledge that scanning probe techniques have already provided the field of photocatalysis, and also to motivate a new generation of effort into the use of such approaches to obtain new insights into the molecular level details of photochemical events occurring at interfaces. Discussion will start with an examination of how scanning probe techniques are being used to characterize the TiO2(110) surface in ways that are relevant to photocatalysis. We will then discuss specific classes of photochemical reaction on TiO2(110) for which SPM has proven indispensible in providing unique molecular-level insights, and conclude with discussion of future areas in which SPM studies may prove valuable to photocatalysis on TiO2. This work was supported by the US Department of Energy, Office of Basic Energy Sciences, Division of Chemical Sciences, Geosciences & Biosciences. I.L. was partially supported by a Pacific Northwest National Laboratory (PNNL) Chemical Imaging Initiative project. PNNL is a multiprogram national laboratory operated for DOE by Battelle.

photocatalysis↗

Band Excitation for Scanning Probe Microscopy

The Band Excitation (BE) technique for scanning probe microscopy uses a precisely determined waveform that contains specific frequencies to excite the cantilever or sample in an atomic force microscope to extract more information, and more reliable information from a sample. There are a myriad of details and complexities associated with implementing the BE technique. There is therefore a need to have a user friendly interface that allows typical microscopists access to this methodology. This software enables users of atomic force microscopes to easily: build complex band-excitation waveforms, set-up the microscope scanning conditions, configure the input and output electronics for generate the waveform as a voltage signal and capture the response of the system, perform analysis on the captured response, and display the results of the measurement.

Jesse, Stephen↗

Graphical template software for accurate micromanipulation in a scanning electron microscope

Micromanipulation techniques in a scanning electron microscope (SEM) have been utilized for assembling micrometer-sized structures. The precision of the assembled microstructures has been limited by the poor accuracy of the SEM image. We have developed a software to assist the operator in the accurate assembly of microstructures in a SEM, in which computer-generated outlines of the target structure [graphical templates (GTs)] are superimposed on the monitor. The displayed GTs are distorted on the basis of the image properties of the SEM evaluated in advance. As a consequence, the operator can construct microstructures with a high precision only by maneuvering the manipulator so that the outline of each object perfectly overlaps the GT without any alteration of the electron optics or circuits for improving the image accuracy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The role of boron segregation in enhanced thermoelectric power factor of CoSi{sub 1-x}B{sub x} alloys

We report on the influence of boron segregation on the thermoelectric properties of CoSi. Contrary to previous suggestions, and in stark contrast to aluminum substitution, boron does not enter the lattice on the Si site, but rather segregates to the grain boundaries in these alloys. Through a combination of x-ray diffraction, scanning electron microscope, and scanning Auger techniques, we present clear evidence of the formation of a CoB phase at the grain boundaries. Consistent with the failure of B to substitute for Si, we observe no changes in the electron concentration or the Seebeck coefficient under boron substitution. The electrical resistivity, on the other hand, displays a non-monotonic behavior with increasing boron concentration, first decreasing for small amounts of boron, before increasing at higher levels of substitution. We attribute this behavior to a combination of an initial healing effect of boron on microcracks, followed by the eventual increase in electron scattering by the secondary CoB phase at higher concentrations.

36 MATERIALS SCIENCE↗

Progress in Development of Electrochemical Methods in Corrosion Science and Engineering

The role and impact of four electrochemical techniques in the study of various corrosion applications are discussed, these are: scanning vibrating electrode technique (SVET), coupled multi-electrode array (CMEA) technique, scanning electrochemical microscope (SECM) and atomic emission spectroelectrochemistry (AESEC). A common theme is an ability to monitor corrosion phenomena in situ on a local electrochemical scale with high resolution of electrochemical and, in some cases, chemical reaction rates. In all cases, the techniques presented here are discussed in the context of specific corrosion problems carried out in full immersion conditions. Examples taken from the current literature, and new data, are presented to demonstrate the use and advantages of these techniques, or a combination of these techniques, as powerful tools for industrially important applications. Here, this includes: assessment of the galvanic interactions and throwing-power of metal-rich primer coatings for active corrosion protection, corrosion/corrosion resistance mechanisms of new metal alloys, the effect of pretreatments on coating integrity, current distributions within a crevice and pitting corrosion.

AESEC↗

Secondary carbides in high chromium cast irons: An alternative approach to their morphological and spatial distribution characterization

Highlights: • Systematic characterization of second phase particles by combining a variety of techniques • Comparison of morphological parameters obtained from SEM, BSE, etching+CLSM and EBSD • Quantitative analysis and degree of distribution of secondary carbides • Particle size, distribution and morphology from image analysis of CLSM, SEM and EBS images - Abstract: Secondary carbides precipitated in high chromium cast irons during thermal treatments were characterized by means of different characterization techniques, including scanning electron microscopy, energy dispersive X-ray spectroscopy, electron backscattered diffraction and a combination of chemical etching with confocal scanning laser microscopy. This set of techniques provides a full morphological, chemical and crystallographic description of the analysed phases. This work evaluated different methods for optimizing the image acquisition for a further image analysis (IA) based on the threshold binarization. Finally, the carbide size, distribution and morphology were determined after IA of the images acquired by aforementioned characterization techniques. Although the different techniques report some dispersion in the value for the average particle size, the particle inter-spacing and aspect ratio meet within the error value. The proposed characterization methodology provides statistically reliable data for a further evaluation of related physical properties in composites.

36 MATERIALS SCIENCE↗

Characterization of low alloy ferritic steel–Ni base alloy dissimilar metal weld interface by SPM techniques, SEM/EDS, TEM/EDS and SVET

The interface region of welded A508–Alloy 52 M is characterized by scanning probe microscope (SPM) techniques, scanning electron microscopy (SEM)/energy dispersive spectroscopy (EDS), transmission electron microscopy (TEM)/Energy Dispersive Spectroscopy (EDS) and scanning vibrate electrode technique (SVET). The regions along the welded A508–Alloy 52 M interface can be categorized into two types according to their different microstructures. In the type-I interface region, A508 and Alloy 52 M are separated by the fusion boundary, while in the type-II interface region, A508 and Alloy 52 M are separated by a martensite zone. A508, martensite zone and grain boundaries in Alloy 52 M are ferromagnetic while the Alloy 52 M matrix is paramagnetic. The Volta potentials measured by scanning Kelvin probe force microscopy (SKPFM) of A508, martensite zone and Alloy 52 M follow the order: V{sub 52} {sub M} > V{sub A508} > V{sub martensite}. The corrosion behavior of A508–Alloy 52 M interface region is galvanic corrosion, in which Alloy 52 M is cathode while A508 is anode. The martensite dissolves faster than Alloy 52 M, but slower than A508 in the test solution. - Highlights: • The A508–Alloy 52 M interface regions can be categorized into two types. • The chromium depleted region is observed along the Alloy 52 M grain boundary. • The Alloy 52 M grain boundaries which are close to the interface are ferromagnetic. • Martensite zone has lower Volta potential but higher corrosion resistance than A508.

36 MATERIALS SCIENCE↗

Evaluation of hybrid depth scanning for carbon-ion radiotherapy

Purpose: In radiotherapy with a scanned carbon-ion beam, its Bragg peak is shifted along the depth direction either by inserting the range shifter plates or by changing the beam-extraction energy of a synchrotron. In the former technique (range shifter scanning: RS), the range shifter plates broaden the beam size and produce secondary fragments through nuclear reactions. In the latter technique (active-energy scanning: ES), it may take several seconds to change the beam energy depending on the synchrotron operation cycle, leading to a long treatment time. The authors propose a hybrid depth scan technique (hybrid scanning: HS), where several beam energies are used in conjunction with the range shifter plates for finer range shift. In this study, HS is evaluated from the viewpoints of dose distribution and treatment time. Methods: Assuming realistic accelerator and beam-delivery systems, the authors performed computer simulations using GEANT4 Monte Carlo code for beam modeling and a treatment planning system to evaluate HS. Three target volumes with the same dimensions of 60 x 60 x 60 mm{sup 3} were generated at depths of 45, 85, and 125 mm in water phantom, and uniform clinical dose was planned for these targets. The sizes of lateral dose falloff and the peak to plateau ratio defined as the ratio of the clinical dose averaged over the target to the clinical dose at the entrance as well as the treatment time were compared among the three depth scan techniques. Results: The sizes of lateral dose falloffs at the center of SOBP are 11.4, 8.5, and 5.9 mm for the three targets in RS, while they are 5.7, 4.8, and 4.6 mm in ES and 6.6, 5.7, and 5.0 mm in HS, respectively. The peak to plateau ratios are 1.39, 1.96, and 2.15 in RS, while they are 1.48, 2.04, and 2.19 in ES and 1.47, 2.03, and 2.18 in HS, respectively. The treatment times are 128.7, 128.6, and 128.6 s in ES, while they are 61.2, 54.6, and 47.8 s in RS and 43.2, 44.1, and 44.7 s in HS, respectively. The multiple scattering and the nuclear reaction by range shifter degraded the beam qualities such as lateral dose falloff and peak to plateau ratio, which was especially pronounced for the shallow target in RS. The depth scan timing was limited by accelerator cycle in ES. That increased the treatment time by a few times. Conclusions: This study revealed that HS can provide dose distributions with steeper lateral dose falloffs and higher peak to plateau ratio comparing to RS and comparable to ES. In addition, the treatment time can be considerably reduced in HS compared to ES.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic elements for switching magnetization magnetic force microscopy tips.

Using combination of micromagnetic calculations and magnetic force microscopy (MFM) imaging we find optimal parameters for novel magnetic tips suitable for switching magnetization MFM. Switching magnetization MFM is based on two-pass scanning atomic force microscopy with reversed tip magnetization between the scans. Within the technique the sum of the scanned data with reversed tip magnetization depicts local atomic forces, while their difference maps the local magnetic forces. Here we propose the design and calculate the magnetic properties of tips suitable for this scanning probe technique. We find that for best performance the spin-polarized tips must exhibit low magnetic moment, low switching fields, and single-domain state at remanence. The switching field of such tips is calculated and optimum shape of the Permalloy elements for the tips is found. We show excellent correspondence between calculated and experimental results for Py elements.

36 MATERIALS SCIENCE↗

Self-sensing cantilevers with integrated conductive coaxial tips for high-resolution electrical scanning probe metrology

The lateral resolution of many electrical scanning probe techniques is limited by the spatial extent of the electrostatic potential profiles produced by their probes. Conventional unshielded conductive atomic force microscopy probes produce broad potential profiles. Shielded probes could offer higher resolution and easier data interpretation in the study of nanostructures. Electrical scanning probe techniques require a method of locating structures of interest, often by mapping surface topography. As the samples studied with these techniques are often photosensitive, the typical laser measurement of cantilever deflection can excite the sample, causing undesirable changes electrical properties. In this work, we present the design, fabrication, and characterization of probes that integrate coaxial tips for spatially sharp potential profiles with piezoresistors for self-contained, electrical displacement sensing. With the apex 100 nm above the sample surface, the electrostatic potential profile produced by our coaxial tips is more than 2 times narrower than that of unshielded tips with no long tails. In a scan bandwidth of 1 Hz–10 kHz, our probes have a displacement resolution of 2.9 Å at 293 K and 79 Å at 2 K, where the low-temperature performance is limited by amplifier noise. We show scanning gate microscopy images of a quantum point contact obtained with our probes, highlighting the improvement to lateral resolution resulting from the coaxial tip.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Automated ICRF heating surrogate modeling via machine learning

This work introduces automated machine learning workflows that address critical bottlenecks in surrogate model development for Ion Cyclotron Range of Frequencies (ICRF) heating applications. The automated framework includes data analysis tools that transform raw datasets into actionable insights in seconds, replacing weeks of manual exploratory effort and ensuring consistent, reproducible dataset characterization. By integrating advanced hyperparameter optimization (HPO) methods including Bayesian optimization via BoTorch and Tree-structured Parzen Estimators (TPE), the framework significantly reduces model development time from weeks to hours, decreasing computational cost and required expertise, while enabling high-accuracy surrogate models. Compared to traditional hyperparameter scanning (HPS) techniques such as methodical, randomized, and grid searches, HPO methods achieve superior convergence and predictive performance, even when compared to already well-tuned reference models. On NSTX High Harmonic Fast Wave (HHFW) heating datasets, both Random Forest Regressor (RFR) and neural network surrogates demonstrate improved accuracy, achieving R 2 values beyond 0.97 and 0.98, respectively. The results show that while HPO gains are modest for robust architectures like RFR, they become essential for more sensitive models such as neural networks, highlighting the trade-offs across optimization strategies. Through automated workflows that eliminate manual hyperparameter tuning and require minimal ML expertise, this work enables widespread adoption of high-fidelity surrogate models across the fusion community for real-time plasma control, uncertainty quantification, rapid experimental scenario development, and integrated system optimization.

Sanchez-Villar, Alvaro [Princeton Plasma Physics L↗

Evaluation of The Thermophysical Properties and Microstructure of UPu{sub 24}Zr{sub 15} Metallic Fuel

Featuring high burn-up, high fissile and fertile isotopic density, inherent safety characteristics, and favorable thermal response, actinide transmutation metallic fuels are considered to be among the most promising fuel classes for next generation fast reactors. During reactor operation, it is anticipated that fluctuations in chemical potential along the temperature gradient will lead to migration and redistribution of constituents between radial zones of the cylindrical fuel pin, resulting in compositional inhomogeneity and hence unpredictable fuel performance. Limited experimental fuel performance data is available for fuel selection and certification, therefore different compositions of options uranium-plutonium-zirconium (UPu- Zr) alloys have been investigated. Several complementary techniques, including scanning and transmission electron microscopy (SEM and TEM, respectively), differential scanning calorimetry (DSC), and laser flash diffusivity (LFD) techniques were used to characterize the phase distribution, microstructure, and thermophysical properties of unirradiated U-Pu-Zr fuels in both the as-cast and annealed condition. This information is necessary to understand the irradiated microstructure, properties, and performance of U-Pu-Zr fuels.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nanoscale Structure and Interfacial Electrochemical Reactivity of Moiré-Engineered Atomic Layers

Here, the electronic properties of atomically thin van der Waals (vdW) materials can be precisely manipulated by vertically stacking them with a controlled offset (for example, a rotational offset─i.e., twist─between the layers, or a small difference in lattice constant) to generate moiré superlattices. In recent years, the application of this “twistronics” concept to interfacial electrochemistry has unveiled unique pathways for tailoring the electrochemical reactivity. Furthermore, this Account provides an overview of our work that leveraged a suite of structural characterization methods, such as interferometric four-dimensional scanning transmission electron microscopy, dark-field transmission electron microscopy, and scanning tunneling microscopy, along with nanoscale electrochemical measurement techniques, namely, scanning electrochemical cell microscopy (SECCM), to uncover and dissect the profound impact of electrode electronic structure, controlled by interlayer twist, on interfacial electron transfer kinetics.

Charge transfer↗

SU-E-T-396: Dosimetric Accuracy of Proton Therapy for Patients with Metal Implants in CT Scans Using Metal Deletion Technique (MDT) Artifacts Reduction

Purpose: To evaluate the dosimetric accuracy for proton therapy patients with metal implants in CT using metal deletion technique (MDT) artifacts reduction. Methods: Proton dose accuracies under CT metal artifacts were first evaluated using a water phantom with cylindrical inserts of different materials (titanium and steel). Ranges and dose profiles along different beam angles were calculated using treatment planning system (Eclipse version 8.9) on uncorrected CT, MDT CT, and manually-corrected CT, where true Hounsfield units (water) were assigned to the streak artifacts. In patient studies, the treatment plans were developed on manually-corrected CTs, then recalculated on MDT and uncorrected CTs. DVH indices were compared between the dose distributions on all the CTs. Results: For water phantom study with 1/2 inch titanium insert, the proton range differences estimated by MDT CT were with 1% for all beam angles, while the range error can be up to 2.6% for uncorrected CT. For the study with 1 inch stainless steel insert, the maximum range error calculated by MDT CT was 1.09% among all the beam angles compared with maximum range error with 4.7% for uncorrected CT. The dose profiles calculated on MDT CTs for both titanium and steel inserts showed very good agreements with the ones calculated on manually-corrected CTs, while large dose discrepancies calculated using uncorrected CTs were observed in the distal end region of the proton beam. The patient study showed similar dose distribution and DVHs for organs near the metal artifacts recalculated on MDT CT compared with the ones calculated on manually-corrected CT, while the differences between uncorrected and corrected CTs were much pronounced. Conclusion: In proton therapy, large dose error could occur due to metal artifact. The MDT CT can be used for proton dose calculation to achieve similar dose accuracy as the current clinical practice using manual correction.

60 APPLIED LIFE SCIENCES↗