Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scintillators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

The Scintillating Optical Fiber Calorimeter Instrument Performance (SOFCAL)

SOFCAL is a balloon-borne instrument designed to measure the P-He cosmic ray spectra from about 200 GeV/amu - 20 TeV/amu. SOFCAL uses a thin lead and scintillating-fiber ionization calorimeter to measure the cascades produced by cosmic rays interacting in the hybrid detector system. Above the fiber calorimeter is an emulsion chamber that provides the interaction target, primary particle identification and in-flight energy calibration for the scintillating fiber data. The energy measurement technique and its calibration are described, and the present results from the analysis of a 1 day balloon flight will be presented.

Christl, M. J.↗

SIFTER: Scintillating Fiber Telescopes for Energetic Radiation, Gamma-Ray Applications

The research project "SIFTER: Scintillating Fiber Telescopes for Energetic Radiation, Gamma-Ray Applications" approved under the NASA High Energy Astrophysics Research Program. The principal investigator of the proposal was Prof. Geoffrey N. Pendleton, who is currently on extended leave from UAH. Prof. William S. Paciesas administered the grant during Dr. Pendleton's absence. The project was originally funded for one year from 6/8/2000 to 6/7/2001. Due to conflicts with other commitments by the PI, the period of performance was extended at no additional cost until 6/30/2002. The goal of this project was to study scintillating fiber pair-tracking gamma-ray telescope configurations specifically designed to perform imaging and spectroscopy in the 5 - 250 MeV energy range. The main efforts were concentrated in two areas: 1) development of tracking techniques and event reconstruction algorithms, with particular emphasis on angular resolution; and 2) investigation of coded apertures as a means to improve the instrument angular resolution at low energies.

Paciesas, William S.↗

The Micro-Arcsecond Scintillation-Induced Variability (MASIV) Survey III. Optical Identifications and New Redshifts

Intraday variability (IDV) of the radio emission from active galactic nuclei is now known to be predominantly due to interstellar scintillation (ISS). The MASIV (The Microarcsecond Scintillation Induced Variability) survey of 443 at spectrum sources revealed that the IDV is related to the radio flux density and redshift. A study of the physical properties of these sources has been severely handicapped by the absence of reliable redshift measurements for many of these objects. This paper presents 79 new redshifts and a critical evaluation of 233 redshifts obtained from the literature. We classify spectroscopic identifications based on emission line properties, finding that 78% of the sources have broad emission lines and are mainly FSRQs. About 16% are weak lined objects, chiefly BL Lacs, and the remaining 6% are narrow line objects. The gross properties (redshift, spectroscopic class) of the MASIV sample are similar to those of other blazar surveys. However, the extreme compactness implied by ISS favors FSRQs and BL Lacs in the MASIV sample as these are the most compact object classes. We confirm that the level of IDV depends on the 5 GHz flux density for all optical spectral types. We find that BL Lac objects tend to be more variable than broad line quasars. The level of ISS decreases substantially above a redshift of about two. The decrease is found to be generally consistent with ISS expected for beamed emission from a jet that is limited to a fixed maximum brightness temperature in the source rest frame.

Pursimo, Tapio↗

ULF Wave-Associated Density Irregularities and Scintillation at the Equator

This paper presents independent multi-instrument observations that address the physical mechanisms of how ultralow-frequency (ULF) wave-associated electric fields initiate ionospheric density fluctuation and scintillation at the equator. Since the magnetic field at the equator is entirely embedded in a relatively high-collision and high-conductivity medium, the condition may not be possible for the geomagnetic field to fluctuate due to ULF wave activity. This implies that the fluctuating electric field at the equator may not be produced through equatorial dynamo action due to fluctuating magnetic fields. Instead, the electric field penetrates from high latitudes and produces fluctuating magnetic field as well as modulates the vertical drift and hence causes the density to fluctuate at the equatorial region. We demonstrate this by estimating the ULF associated fluctuating electric field at high latitudes and at the equatorial region by applying the appropriate attenuation factor as it penetrates to lower latitudes. The periodicity of both electric field and density fluctuations appears to be between 6 and 9 min, which is a typical period of ULF waves in the Pc5 range. Because of its large amplitude and long periods compared to other ULF wave frequency bands, the Pc5 wave-associated electric field, which can even be estimated using magnetograms with low sensitivity and low sampling rate (e.g., 1 min), can easily penetrate to the lower latitude region and produce significant ionospheric density fluctuations that can be strong enough to create scintillation at the equatorial region.

Yizengaw, E.↗

Gated-Dynode Photomultiplier Tube Assembly for the Boronated Scintillator Detector of the ISS-CREAM Experiment

We present the design of a four-photomultiplier tube (PMT) assembly for measuring light generation in theBoronated Scintillator Detector (BSD) of the Cosmic Ray Energetics And Mass experiment for the InternationalSpace Station (ISS-CREAM). The light produced in the scintillator includes a contribution from the captureof thermalized neutrons produced in cosmic ray interactions, as well as delayed fluorescence, in the range ofseveral microseconds following the incident cosmic ray impact. The BSD is held in an insensitive state until acosmic-ray trigger causes a rapid turn on of the PMTs to detect late light signals, several microseconds afterthe trigger. The design includes two pulsed high-voltage supplies, which serve to gate the first two dynodesof the Hamamatsu R1924A PMTs used in the assembly. When the dynode gates are held in the "off" state,this scheme is shown to suppress >105 photons from injection into the tube's multiplier stage, while beingcapable of rapid switching into a stable operating mode in less than 1 s. This mitigates any backgroundsfrom afterpulsing that might otherwise be present in the PMT response following the cosmic ray incidence.

Anderson, T.↗

Scintillating Bubble Chambers for Direct Dark Matter Detection, and an Update on SBC-LAr10

The Scintillating Bubble Chamber (SBC) Collaboration aims to use the liquid-noble bubble chamber technology as a low-threshold detector for dark matter particles of 1-10 GeV/c2. The detector combines the remarkable electron recoil (ER) discrimination of the bubble chamber with the event-by-event energy resolution provided by liquid argon (LAr) scintillation, with the crucial added benefit that ER discrimination in liquid-noble bubble chambers extends to much lower thresholds than in past freon-filled bubble chambers, with the potential for quasi-background-free operation at thresholds of 100 eV in nuclear recoil (NR) energy. SBC has developed two functionally identical 10 kg detectors: SBC-LAr10 at Fermilab will calibrate low-threshold performance, while the radio-pure SBC-SNOLAB chamber will execute SBC s first deep-underground dark matter search. SBC-LAr10 at Fermilab was recently installed in the MINOS tunnel 100 meters underground, and the first bubbles are expected this fall. I will present the current status of SBC-LAr10 and describe the suite of gamma and neutron calibrations we will execute. The calibrations will confirm the physics reach of this new technology, motivating not just the SBC-SNOLAB chamber now being assembled but also future searches into the solar neutrino fog at 1 GeV/c2.

Sheng, Zhiheng↗

Compounds and composition for preparation of lithium-loaded plastic scintillators

A scintillator material includes a polymer matrix, a primary dye in the polymer matrix, the primary dye being a fluorescent dye; a secondary dye, and a Li-containing compound in the polymer matrix, where the Li-containing compound is a Li salt of a short-chain aliphatic acid. In addition, the scintillator material exhibits an optical response signature for thermal neutrons that is different than an optical response signature for fast neutrons.

Zaitseva, Natalia P.↗

Scintillation light calibrations, systematic uncertainties, and triggering efficiency in the MicroBooNE detector

Scintillation light, produced alongside ionisation charge from particle interactions, plays a critical role in liquid argon time projection chamber (LArTPC) detectors. A detailed understanding of its production and detection mechanisms is essential for robust calibration, systematic uncertainty evaluation, and physics analysis. This article describes the MicroBooNE light simulation, light-based triggering schemes, photomultiplier tube gain calibration, light response stability, and light-based systematic uncertainties over the course of five years of data collection. In addition, we present a measurement of scintillation light triggering efficiency, focusing on the lowest-light regime relevant to rare-event searches and low-energy neutrino interactions. Finally, we discuss two notable observations in MicroBooNE's data, both reported here for the first time: an approximately 50% decline in MicroBooNE's light yield over time, concentrated in the first two years of running; and a higher than expected O(200 kHz) rate of single photoelectron noise. The results presented provide an important benchmark of long-term light detection performance in LArTPC neutrino detectors.

Abratenko, P. [Tufts U.]↗

From Detector Layout to Signal Analysis: Geometry Optimization and Neutron-Gamma Tagging in Plastic Scintillator Detectors

Neutrinos are elementary particles with many properties still unknown. Their masses so far have only upper and lower limits. Still, due to neutrino oscillations, it is clear that they are not massless, as stated by the Standard Model of Elementary Particles. Neutrinos are also present in the Universe in vast amounts, but they rarely interact with the surrounding matter. Their abundance makes them very interesting for many theories beyond the Standard Model, e.g., dark matter searches and CP symmetry violation in the leptonic sector, which could be (partially) responsible for the observed matter-antimatter asymmetry in today's Universe.\\ The Deep Underground Neutrino Experiment (DUNE) is a next-generation accelerator-based neutrino oscillation experiment that will study neutrinos with unprecedented precision and may answer many open questions. DUNE uses a powerful neutrino beam from Fermilab. It consists of a Near Detector (ND) complex to measure neutrinos before oscillat ion, and a Far Detector (FD) complex $1300\ \mathrm{km}$ away to measure them after oscillation. As part of the ND complex, measurements are also possible with different angles to the neutrino beam. This enables excellent control of systematic uncertainties of e.g., neutrino cross section measurements.\\ One detector in the near detector complex is The Muon Spectrometer (TMS), an extension of a Liquid Argon (LAr) detector that measures the charge and momentum of muons produced in neutrino interactions within the LAr. The design of this detector, which consists of alternating layers of steel and plastic scintillator bars, must be optimized for the expected muon energies.\\ In this thesis, a study of the optimal module orientation plan is presented, which is necessary for the physics performance of the near detector complex and, by extension, DUNE. As part of this study, the event reconstruction was also developed and improved. Simulated muons are then reconstructed, and the performan ce of different module orientation plans is tested.\\ As a second part, a study of neutron and gamma tagging using a Pulse Shape Discriminating (PSD) plastic scintillator is presented. The properties of this material allow particle differentiation based on the temporal distribution of emitted light. A novel approach to using the individual light signals was successfully tested using data from a small, local test setup.

Nehm, Asa [Mainz U.]↗

The effect of radiation damage on the light yield and uniformity of candidate plastic scintillator tiles for the CMS hadron calorimeter upgrade

A study has been performed to understand the effects of radiation damage on various plastic scintillator tiles considered for a possible upgrade of the hadron calorimeter of the CMS detector. Measurements were made with unirradiated tiles and with tiles that had been irradiated in the CMS collision hall to a dose of 44 kGy. Results are presented for the tiles of different shapes in terms of the energy spectrum, efficiency as a function of the position at which each tile was hit, as well as light yield. All the tiles showed a light reduction of up to about 50%. The tiles with the shape currently used in the CMS detector did not see increased non-uniformity of light collection, while a significant disuniformity was observed for the tiles considered as alternatives.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of the nat Ti(d,x) 49 V excitation function by liquid scintillation analysis

Here, the experimental cross-sections for deuteron-induced nuclear reactions on natural titanium were measured using the stacked-foil method. Deuteron beams were provided by a Pelletron tandem accelerator at incident energies up to 8 MeV. The cross-sections for the production of 49 V were determined by liquid scintillation analysis, with the highest measured value of 522(32) mb occurring at 5.59(9) MeV. Additionally, the cross-sections for the production of 44m,46,47,48 Sc and 48 V were evaluated using gamma-ray spectroscopy and compared to some available literature.

43 PARTICLE ACCELERATORS↗

Upgrade of the CAESium-iodide scintillator ARray (CAESAR) electronics and data acquisition system for optimized performance at FRIB

Here, we report on the upgrade of the electronics and data acquisition (DAQ) of the high-efficiency CAESium-iodide scintillator ARray (CAESAR) at the Facility for Rare Isotope Beams (FRIB). With the on-going capability ramp-up of FRIB, CAESAR is expected to continue to be an in-demand -ray spectrometer owing to its high detection efficiency, compactness, and modularity, enabling easy integration with additional detection and DAQ systems. Within this context, the CAESAR electronics and DAQ were upgraded to remove obsolete modules, enhance the ease of integration with external instruments, and optimize the DAQ live time. We present the comprehensive results from offline (γ-ray sources) and online (in-beam experiment) commissioning, characterizing the performance of CAESAR’s new electronics and DAQ.

CsI(Na) scintillator array↗

Doping liquid argon with xenon in ProtoDUNE Single-Phase: effects on scintillation light

Doping of liquid argon TPCs (LArTPCs) with a small concentration of xenon is a technique for light-shifting and facilitates the detection of the liquid argon scintillation light. In this paper, we present the results of the first doping test ever performed in a kiloton-scale LArTPC. From February to May 2020, we carried out this special run in the single-phase DUNE Far Detector prototype (ProtoDUNE-SP) at CERN, featuring 720 t of total liquid argon mass with 410 t of fiducial mass. A 5.4 ppm nitrogen contamination was present during the xenon doping campaign. The goal of the run was to measure the light and charge response of the detector to the addition of xenon, up to a concentration of 18.8 ppm. The main purpose was to test the possibility for reduction of non-uniformities in light collection, caused by deployment of photon detectors only within the anode planes. Light collection was analysed as a function of the xenon concentration, by using the pre-existing photon detection system (PDS) of ProtoDUNE-SP and an additional smaller set-up installed specifically for this run. In this paper we first summarize our current understanding of the argon-xenon energy transfer process and the impact of the presence of nitrogen in argon with and without xenon dopant. We then describe the key elements of ProtoDUNE-SP and the injection method deployed. Two dedicated photon detectors were able to collect the light produced by xenon and the total light. The ratio of these components was measured to be about 0.65 as 18.8 ppm of xenon were injected. We performed studies of the collection efficiency as a function of the distance between tracks and light detectors, demonstrating enhanced uniformity of response for the anode-mounted PDS. We also show that xenon doping can substantially recover light losses due to contamination of the liquid argon by nitrogen.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the liquid argon scintillation pulse shape using differentiable simulation in the coherent CAPTAIN-Mills experiment

The coherent CAPTAIN-Mills (CCM) experiment is a liquid argon (LAr) light collection detector searching for MeV-scale neutrino and beyond Standard Model physics signatures. Two hundred eight-inch photomultiplier tubes instrument the seven-ton fiducial volume with 50% photocathode coverage to detect light produced by charged particles. CCM’s light-based approach reduces requirements of LAr purity, compared to other detection technologies, such that sub-MeV particles can be reliably detected without additional LAr filtration and with 𝒪⁡(1) parts per million of common contaminants. We present a measurement of LAr light production and propagation parameters, with uncertainties, obtained from a sample of MeV-scale electromagnetic events. The optimization of this high-dimensional parameter space was facilitated by a differentiable optical photon Monte Carlo simulation and detailed photomultiplier tube response characterization. This result accurately predicts the timing and spatial distribution of light due to scintillation and Cherenkov emission in the detector. This is the first description of photon propagation in LAr to include several effects, including anomalous dispersion of the index of refraction near the ultraviolet resonance, Mie scattering from impurities, and Cherenkov light production.

Cherenkov detectors↗

Measurement of the sodium and iodine scintillation quenching factors across multiple NaI(Tl) detectors to identify systematics

The amount of light produced by nuclear recoils in scintillating targets is strongly quenched compared to that produced by electrons. A precise understanding of the quenching factor is particularly interesting for weakly interacting massive particles (WIMP) searches and coherent elastic neutrino-nucleus scattering ( CE ν NS ) measurements since both rely on nuclear recoils, whereas energy calibrations are more readily accessible from electron recoils. There is a wide variation among the current measurements of the quenching factor in sodium iodide (NaI) crystals, especially below 10 keV, the energy region of interest for dark matter and CE ν NS studies. A better understanding of the quenching factor in NaI(Tl) is of particular interest for resolving the decades-old puzzle in the field of dark matter between the null results of most WIMP searches and the claim for dark matter detection by the DAMA/LIBRA collaboration. In this work, we measured sodium and iodine quenching factors for five small NaI(Tl) crystals grown with similar thallium concentrations and growth procedures. Unlike previous experiments, multiple crystals were tested, with measurements made in the same experimental setup to control systematic effects. The quenching factors agree in all crystals we investigated, and both sodium and iodine quenching factors are smaller than those reported by DAMA/LIBRA. The dominant systematic effect was due to the electron equivalent energy calibration originating from the nonproportional behavior of the NaI(Tl) light yield at lower energies, potentially the cause for the discrepancies among the previous measurements. Published by the American Physical Society 2024

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Crystal Growth, Optical and Scintillation Properties of Eu 2+ -doped TlSr 2 Br 5

Crystals of undoped and Eu 2+ -doped TlSr 2 Br 5 of up to 16 mm in diameter and 50 mm in length were grown by the Vertical Bridgman technique. TlSr 2 Br 5 has the monoclinic crystal structure with space group P21/c. Its density and Z eff are 5.03 g/cm 3 and 58.6, respectively. Radioluminescence spectra of undoped and Eu 2+ -doped TlSr 2 Br 5 feature a broad emission band peaking at about 440 nm for undoped and 520 nm for Eu 2+ -doped crystals. The light yield of undoped TlSr 2 Br 5 is 42,000 ph/MeV, which increases to 55,000 ph/MeV for Eu 2+ -doped crystals. The energy resolution at 662 keV ( 137 Cs) is about 5 – 6% (FWHM). As a result, the scintillation decay of undoped and Eu 2+ -doped TlSr 2 Br 5 is of the order of 100s of nanoseconds.

Bridgman technique↗

Design and Performance of an InAs Quantum Dot Scintillator with Integrated Photodetector

A new scintillation material composed of InAs quantum dots (QDs) hosted within a GaAs matrix was developed, and its performance with different types of radiation is evaluated. A methodology for designing an integrated photodetector (PD) with a low defect density and that is optically matched to the QD’s emission spectrum is introduced, utilizing an engineered epitaxial InAlGaAs metamorphic buffer layer. The photoluminescence (PL) collection efficiency of the integrated PD is examined using two-dimensional scanning laser excitation. The detector response to 5.5 MeV α-particles and 122 keV photons is presented. Yields of 13 electrons/keV for α-particles and 30–60 electrons/keV for photons were observed. The energy resolution of 12% observed with α-particles was mainly limited by noise- and geometry-related optical losses. The radiation hardness of an InAs QDs hosted within GaAs and a wider band gap AlGaAs ternary alloy was studied under a 1 MeV proton implantation up to a 10 14 cm –2 dose. The integrated PL responses were compared to evaluate PL quenching due to non-radiative defects. The QDs embedded in the AlGaAs demonstrated improved radiation hardness compared to QDs in the GaAs matrix and in the InGaAs quantum wells.

36 MATERIALS SCIENCE↗