Search NASA⌕ Search

SEARCH · Search NASA

Results for “Signal Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

A Saturn launched X-ray astronomy experiment. Volume 2: S-150

In order to develop an experiment which would provide previously unknown information at the projected new launch period, a decision was made to modify the S-027 experiment to allow detection of lower energies which had previously not been mapped. The modification basically required that the static counters be replaced with a thin film entrance window gas flow counter which would allow detection of X-ray energies as low as 150 ev. The new experiment designated S-150 was designed to detect X-ray energies over a spectrum of 150 ev to 10 Kev. Photographs of the S-150 experiment are shown. Basically the same signal detection and processing techniques were used on the S-150 experiment as were used on the S-027. For economic reasons much of the S-027 subassembly hardware was used on the new experiment. The main design changes were in the signal detection system and the high energy veto system.

Source record↗

Sleuthing the MSL EDL Performance from an X Band Carrier Perspective

During the Entry, Descent, and Landing (EDL) of NASA's Mars Science Laboratory (MSL), or Curiosity, rover to Gale Crater on Mars on August 6, 2012 UTC, the rover transmitted an X-band signal composed of carrier and tone frequencies and a UHF signal modulated with an 8kbps data stream. During EDL, the spacecraft's orientation is determined by its guidance and mechanical subsystems to ensure that the vehicle land safely at its destination. Although orientation to maximize telecom performance is not possible, antennas are especially designed and mounted to provide the best possible line of sight to Earth and to the Mars orbiters supporting MSL's landing. The tones and data transmitted over these links are selected carefully to reflect the most essential parameters of the vehicle's state and the performance of the EDL subsystems for post-EDL reconstruction should no further data transmission from the vehicle be possible. This paper addresses the configuration of the X band receive system used at NASA / JPL's Deep Space Network (DSN) to capture the signal spectrum of MSL's X band carrier and tone signal, examines the MSL vehicle state information obtained from the X band carrier signal only and contrasts the Doppler-derived information against the post-EDL known vehicle state. The paper begins with a description of the MSL EDL sequence of events and discusses the impact of the EDL maneuvers such as guided entry, parachute deploy, and powered descent on the frequency observables expected at the DSN. The range of Doppler dynamics possible is derived from extensive 6 Degrees-Of-Freedom (6 DOF) vehicle state calculations performed by MSL's EDL simulation team. The configuration of the DSN's receive system, using the Radio Science Receivers (RSR) to perform open-loop recording for both for nominal and off-nominal EDL scenarios, is detailed. Expected signal carrier power-to-noise levels during EDL are shown and their impact on signal detection is considered. Particular attention is given to the selection of the appropriate RSR processing bandwidths and to its configuration for real-time signal detection. The X-band carrier frequency obtained through post-processing of the open-loop recorded spectrum is given. Detection of spacecraft status and completion of key vehicle events through their Doppler signature is discussed and illustrated. This Doppler-derived information is compared against the very accurate vehicle data obtained post-EDL via MSL's UHF radio subsystem. The paper concludes with a discussion on the advantages and disadvantages of transmitting the X-band carrier and tone signal in the general context of EDL communications and lessons learned for future missions with EDL sequences are given

Mars Science Laboratory (MSL)↗

WE-AB-BRB-02: Development of a Micro-Sized Dosimeter for Real-Time Dose Monitoring and Small Field Dosimetry

Purpose: To investigate a miniature optical dosimeter for real-time, high-resolution dosimetry, and explore its potential applications for in vivo measurements and small field dosimetry. Methods: A micro-sized hemispherical (400 µm radius) scintillating detector was constructed from lanthanide activated phosphors doped with Europium (GOS:Eu) and encapsulated in a 17 gauge plastic catheter. A photon counting PMT and CCD-chip spectrometer were used to detect signals emitted from the detector. A single band-passing spectral approach (630nm) was implemented to discriminate the micro-phosphor optical signal from background signals (Cerenkov radiation) in the optical fiber. To test real-time monitoring capabilities, a 3D-printed phantom was used to detect an 192Ir HDR brachytherapy source at locations ranging from 1 to 4 cm radially and 12 cm along the travel axis of the HDR wire. To test the application of the micro-sized detector for small field dosimetry, the linearity of detector was characterized through irradiation of 6MV photon beam at dose-rates ranging from 100 to 600 MU, and the effect of field size was characterized through detections of beams ranging from 30×30 to 1×1 cm2 size. Results: With a 1 second integration time for the spectrometer, the recorded measurements indicated that the micro-sized detector allowed accurate detection of source position at distances of up to 6 cm along the axis of travel in water. EB measurements showed that the detected signal was linearly correlated with dose rate (R{sup 2} = 0.99). The crossbeam profile was determined with a step size of ∼500 µm. Conclusion: Miniaturization of optical dosimeters is shown to be possible through the construction of lanthanide activated doped phosphors detectors. The small size of the detector makes it amenable to a variety of applications, including real-time dose delivery verification during HDR brachytherapy and EB beam calibrations in small fields.

60 APPLIED LIFE SCIENCES↗

Prospects for observing and localizing gravitational-wave transients with Advanced LIGO, Advanced Virgo and KAGRA

We present possible observing scenarios for the Advanced LIGO, Advanced Virgo and KAGRA gravitational-wave detectors over the next decade, with the intention of providing information to the astronomy community to facilitate planning for multi-messenger astronomy with gravitational waves. We estimate the sensitivity of the network to transient gravitational-wave signals, and study the capability of the network to determine the sky location of the source. We report our findings for gravitational-wave transients, with particular focus on gravitational-wave signals from the inspiral of binary neutron star systems, which are the most promising targets for multi-messenger astronomy. The ability to localize the sources of the detected signals depends on the geographical distribution of the detectors and their relative sensitivity, and 90% credible regions can be as large as thousands of square degrees when only two sensitive detectors are operational. Determining the sky position of a significant fraction of detected signals to areas of 5– 20 deg 2 requires at least three detectors of sensitivity within a factor of ~2 of each other and with a broad frequency bandwidth. When all detectors, including KAGRA and the third LIGO detector in India, reach design sensitivity, a significant fraction of gravitational-wave signals will be localized to a few square degrees by gravitational-wave observations alone.

79 ASTRONOMY AND ASTROPHYSICS↗

Prospects for Observing and Localizing Gravitational-Wave Transients with Advanced LIGO and Advanced Virgo

We present a possible observing scenario for the Advanced LIGO and Advanced Virgo gravitational-wave detectors over the next decade, with the intention of providing information to the astronomy community to facilitate planning for multi-messenger astronomy with gravitational waves. We determine the expected sensitivity of the network to transient gravitational-wave signals, and study the capability of the network to determine the sky location of the source. We report our findings for gravitational-wave transients, with particular focus on gravitational-wave signals from the inspiral of binary neutron-star systems, which are considered the most promising for multi-messenger astronomy. The ability to localize the sources of the detected signals depends on the geographical distribution of the detectors and their relative sensitivity, and 90% credible regions can be as large as thousands of square degrees when only two sensitive detectors are operational. Determining the sky position of a significant fraction of detected signals to areas of 5 sq. deg to 20 sq. deg will require at least three detectors of sensitivity within a factor of approximately 2 of each other and with a broad frequency bandwidth. Should the third LIGO detector be relocated to India as expected, a significant fraction of gravitational-wave signals will be localized to a few square degrees by gravitational-wave observations alone.

counterparts↗

On a New Detection Scheme for M-ary Orthogonal Coherent State Signal

We propose a new receiver for M-ary orthogonal coherent-state signal. It is shown that the proposed receiver performs better than a photon counting receiver as to signal detection error probability criterion. It is also shown that the error probability of the proposed receiver is almost minimum for the signal.

Yamazaki, Kouichi↗

Detecting 1mm/Year Signals in Altimetric Global Sea Level: Effect of Atmospheric Water Vapor and Precipitation

Several research efforts exist to use Topography Experiment (TOPEX)/ Projet d'Observatorie de Surveillance et d'Etudes Integrees de la Dynamique des Oceans (Poseidon) (T/P) to detect changes in global sea level possibly associated with climate change. This requires much better than 1 mm/yr accuracy, something that none of the instruments in T/P [or the European Remote Sensing (ERS-2) satellite, or the U.S. Navy's Geosat Follow-On (GFO) satellite] were designed for. This work focuses on the ability of the T/P microwave radiometer (TMR) to retrieve the path delay due to atmospheric water vapor along the altimeter's path with accuracy in the time changes below 1 mm/yr on global average. In collaboration with Stephen Keihm of JPL and Christopher Ruf of Pennsylvania State University, we compared TMR path delay (PD) estimates with atmospheric precipitable water (PW) from the Special Sensor Microwave Imager (SSMI) aboard the Defense Meteorological Satellite Program (DMSP) series of satellites for 1992-1998 to selected radiosondes, and we also looked at the brightness temperatures measured by TMR in the lowest 1% of the histogram. The conclusion is that TMR had a slow instrumental drift, associated with the 18-GHz channel, which causes an approximate underestimation of water vapor at a rate equivalent to 1.2 mm/yr in path delay between 1992 and 1996; this effect stopped and no drift is detected in 1997. The same study concluded that there is no detectable scale error (one which is proportional to measured vapor) in TMR. In related work, carried out with graduate student Damien Cailliau, we investigated the relative abilities of TMR, SSMI and the UP dual-frequency radar altimeter to detect rain, relative to a climatology of shipborne observations. Rain is a crucial but poorly measured variable in studies of the climate system, and a dedicated mission, Tropical Rainfall Measuring Mission (TRMM), was recently launched to measure it. However, the climatologies built over the past 10 years used passive radiometers, such as SSMI, or infrared observation from National Oceanic and Atmospheric Administration (NOAA) geostationary satellites. We concluded that the dual-frequency altimeter does an excellent job at retrieving rain on scales much smaller than the passive radiometer, and a better job at retrieving total precipitation (rain as well as snow) at high latitudes. This work improves the sea level observations by allowing better flagging of observations contaminated by rain, and more importantly, provides an alternative way to measure rainfall over the oceans.

Zlotnicki, Victor↗

Dark freeze-out cogenesis

We propose a new mechanism where a multi-component dark sector generates the observed dark matter abundance and baryon asymmetry and thus addresses the coincidence between the two. The thermal freeze-out of dark matter annihilating into meta-stable dark partners sets the dark matter relic abundance while providing the out-of-equilibrium condition for baryogenesis. The meta-stable state triggers baryon asymmetry production by its decay well after the freeze-out and potentially induces a period of early matter domination before its decay. The dark matter and baryon abundances are related through number conservation within the dark sector (cogenesis). The “coincidence” is a natural outcome with GeV- to TeV-scale symmetric dark matter and the dark sector’s interactions with the Standard Model quarks. We present a UV-complete model and explore its phenomenological predictions, including dark matter direct detection signals, LHC signatures of new massive particles with color charges and long-lived particles with displaced vertices, dark matter-induced nucleon conversions, (exotic) dark matter indirect detection signals, and effects on the cosmological matter power spectrum. As a side result, we provide a novel analytical treatment for dark sector freeze-out, which may prove useful in the study of related scenarios.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Windshear detection radar signal processing studies

This final report briefly summarizes research work at Clemson in the Radar Systems Laboratory under the NASA Langley Research Grant NAG-1-928 in support of the Antenna and Microwave Branch, Guidance and Control Division, program to develop airborne sensor technology for the detection of low altitude windshear. A bibliography of all publications generated by Clemson personnel is included. An appendix provides abstracts of all publications.

Baxa, Ernest G., Jr.↗

Stimulus configuration determines the detectability of motion signals in noise

We measured the detectability of moving signal dots in dynamic noise to determine whether local motion signals are preferentially combined along an axis parallel to the direction of motion. Observers were asked to detect a signal composed of three dots moving in a linear trajectory among dynamic noise dots. The signal dots were collinear and equally spaced in a configuration that was either parallel to or perpendicular to their trajectory. The probability of detecting the signal was measured as a function of noise density, over a range of signal dot spacings from 0.5 degrees to 5.0 degrees. At any given noise density, the signal in the parallel configuration was more detectable than that in the perpendicular configuration. Our four observers could tolerate 1.5-2.5 times more noise in the parallel configuration. This improvement is not due merely to temporal summation between consecutive dots in the parallel trajectory. Temporal summation functions measured on our observers indicate that the benefit from spatial coincidence of the dots lasts for no more than 50 ms, whereas the increased detectability of the parallel configuration is observed up to the largest temporal separations tested (210 ms). These results demonstrate that dots arranged parallel to the signal trajectory are more easily detected than those arranged perpendicularly. Moreover, this enhancement points to the existence of visual mechanisms that preferentially organize motion information parallel to the direction of motion.

Non-NASA Center↗

Quantum Enhanced Probes of Magnetic Circular Dichroism

Magneto-optical microscopies, including optical measurements of magnetic circular dichroism, are increasingly ubiquitous tools for probing spin-orbit coupling, charge-carrier g-factors, and chiral excitations in matter, but the minimum detectable signal in classical magnetic circular dichroism measurements is fundamentally limited by the shot-noise limit of the optical readout field. Here, a two-mode squeezed light source is used to improve the minimum detectable signal in magnetic circular dichroism measurements by 3 decibels compared with state-of-the-art classical measurements, even with relatively lossy samples like terbium gallium garnet. Furthermore, these results provide a framework for new quantum-enhanced magneto-optical microscopies that are particularly critical for environmentally sensitive materials and for low temperature measurements where increased optical power can introduce unacceptable thermal perturbations.

42 ENGINEERING↗

Signal processing in SETI

It is believed that the Galaxy might contain ten billion potential life sites. In view of the physical inaccessibility of extraterrestrial life on account of the vast distances involved, a logical first step in a search for extraterrestrial intelligence (SETI) appears to be an attempt to detect signals already being radiated. The characteristics of the signals to be expected are discussed together with the search strategy of a NASA program. It is pointed out that all presently planned searches will use existing radio-astronomy antennas. If no extraterrestrial intelligence signals are discovered, society will have to decide whether SETI justifies a dedicated facility of much greater collecting area. Attention is given to a multichannel spectrum analyzer, CW signal detection, pulse detection, the pattern detector, and details of SETI system operation.

Cullers, D. K.↗

Eye-tracking of nodule detection in lung CT volumetric data

Purpose: Signal detection on 3D medical images depends on many factors, such as foveal and peripheral vision, the type of signal, and background complexity, and the speed at which the frames are displayed. In this paper, the authors focus on the speed with which radiologists and naïve observers search through medical images. Prior to the study, the authors asked the radiologists to estimate the speed at which they scrolled through CT sets. They gave a subjective estimate of 5 frames per second (fps). The aim of this paper is to measure and analyze the speed with which humans scroll through image stacks, showing a method to visually display the behavior of observers as the search is made as well as measuring the accuracy of the decisions. This information will be useful in the development of model observers, mathematical algorithms that can be used to evaluate diagnostic imaging systems. Methods: The authors performed a series of 3D 4-alternative forced-choice lung nodule detection tasks on volumetric stacks of chest CT images iteratively reconstructed in lung algorithm. The strategy used by three radiologists and three naïve observers was assessed using an eye-tracker in order to establish where their gaze was fixed during the experiment and to verify that when a decision was made, a correct answer was not due only to chance. In a first set of experiments, the observers were restricted to read the images at three fixed speeds of image scrolling and were allowed to see each alternative once. In the second set of experiments, the subjects were allowed to scroll through the image stacks at will with no time or gaze limits. In both static-speed and free-scrolling conditions, the four image stacks were displayed simultaneously. All trials were shown at two different image contrasts. Results: The authors were able to determine a histogram of scrolling speeds in frames per second. The scrolling speed of the naïve observers and the radiologists at the moment the signal was detected was measured at 25–30 fps. For the task chosen, the performance of the observers was not affected by the contrast or experience of the observer. However, the naïve observers exhibited a different pattern of scrolling than the radiologists, which included a tendency toward higher number of direction changes and number of slices viewed. Conclusions: The authors have determined a distribution of speeds for volumetric detection tasks. The speed at detection was higher than that subjectively estimated by the radiologists before the experiment. The speed information that was measured will be useful in the development of 3D model observers, especially anthropomorphic model observers which try to mimic human behavior.

60 APPLIED LIFE SCIENCES↗

Analysis of Technology for Compact Coherent Lidar

In view of the recent advances in the area of solid state and semiconductor lasers has created new possibilities for the development of compact and reliable coherent lidars for a wide range of applications. These applications include: Automated Rendezvous and Capture, wind shear and clear air turbulence detection, aircraft wake vortex detection, and automobile collision avoidance. The work performed by the UAH personnel under this Delivery Order, concentrated on design and analyses of a compact coherent lidar system capable of measuring range and velocity of hard targets, and providing air mass velocity data. The following is the scope of this work. a. Investigate various laser sources and optical signal detection configurations in support of a compact and lightweight coherent laser radar to be developed for precision range and velocity measurements of hard and fuzzy targets. Through interaction with MSFC engineers, the most suitable laser source and signal detection technique that can provide a reliable compact and lightweight laser radar design will be selected. b. Analyze and specify the coherent laser radar system configuration and assist with its optical and electronic design efforts. Develop a system design including its optical layout design. Specify all optical components and provide the general requirements of the electronic subsystems including laser beam modulator and demodulator drivers, detector electronic interface, and the signal processor. c. Perform a thorough performance analysis to predict the system measurement range and accuracy. This analysis will utilize various coherent laser radar sensitivity formulations and different target models.

Amzajerdian, Farzin↗

Detection of signals in the ion cyclotron frequency range at the edge during ICRF heating on ASDEX Upgrade

The ICRF system on ASDEX Upgrade is equipped with an arc detector based on the observation of frequencies between 5 and 25 MHz in the RF feeding line [R1]. On some shots, the detector was triggered in an anomalous way: tenths of detections over several hundreds of milliseconds on detectors of all antennas at the same time [R2]. It was suggested that these frequencies were not excited by arcs but came from the plasma. We installed a RF probe inside the vacuum vessel and connected it to a fast acquisition system. We indeed observed frequencies during ICRF heating of several shots. We present here the features of these frequencies, their possible conditions of existence in terms of plasma and RF parameters (magnetic field, density, temperature, RF frequency, power injected) and we compare the source of these frequencies with known phenomena like ICE, CAE and surface waves.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Detection and Signal Processing for Near-Field Nanoscale Fourier Transform Infrared Spectroscopy

Researchers from a broad spectrum of scientific and engineering disciplines are increasingly using scattering-type near-field infrared spectroscopic techniques to characterize materials non-destructively with nanoscale spatial resolution. However, a sub-optimal understanding of a technique's implementation can complicate data interpretation and act as a barrier to entering the field. Here the key detection and processing steps involved in producing scattering-type near-field nanoscale Fourier transform infrared spectra (nano-FTIR) are outlined. The self-contained mathematical and experimental work derives and explains: i) how normalized complex-valued nano-FTIR spectra are generated, ii) why the real and imaginary components of spectra qualitatively relate to dispersion and absorption respectively, iii) a new and generally valid equation for spectra which can be used as a springboard for additional modeling of the scattering processes, and iv) an algebraic expression that can be used to extract an approximation to the sample's local extinction coefficient from nano-FTIR. The algebraic model for weak oscillators is validated with nano-FTIR and attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectra on samples of polystyrene and Kapton and further provides a pedagogical pathway to cementing some of the technique's key qualitative attributes.

36 MATERIALS SCIENCE↗