Search NASA⌕ Search

SEARCH · Search NASA

Results for “Site occupancy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Managing Hanford's Direct Feed Low Activity Waste Program - 20002

The Office of River Protection (ORP) is responsible for the management and completion of the River Protection Project (RPP) mission, which comprises both the Hanford Site tank farms operations and the completion and operation of the Waste Treatment and Immobilization Plant Project. The RPP mission is to safely retrieve, treat, and immobilize Hanford's high-level and low-activity tank waste and close the tank farms to protect the Columbia River. The Direct-Feed Low-Activity Waste (DFLAW) Program is a major subset of the overall RPP mission, providing disposition of low-activity waste. The scope is to retrieve, treat, and immobilize the low-activity waste at the Low-Activity Waste Facility. DFLAW will begin operations no later than December 2023. The DFLAW Program overarches a suite of individual projects, activities, and infrastructure upgrades. The major projects and activities include multiple contractors under both ORP and the Richland Operations Office, underscoring the need for effective integration, coordination, and collaboration. The objectives of the DFLAW Program leadership team are to: - Effectively coordinate and integrate the projects that comprise the DFLAW Program - Manage the interfaces between the projects so that the integrated DFLAW Program is completed successfully - Ensure the DFLAW portfolio of projects operate as required without gaps or conflicts at the interfaces. DOE is accomplishing these objectives through a newly established leadership model that integrates the DOE and contractor work streams and promotes a teamwork model to enable collaborative success. Long considered one of the most formidable cleanup challenges at Hanford, the Department of Energy and its contractors are on the verge of achieving a cleanup commitment that has been decades in the making. DOE is preparing to vitrify (turn to glass) Hanford's chemical and radioactive tank waste using the DFLAW process. The Modified Consent Decree milestone for completing hot commissioning of the Hanford Site's Low- Activity Waste Facility is Dec. 31, 2023. While this milestone may seem distant under normal project management circumstances, it is a relatively short period of time for the operational and cultural transformation necessary to successfully begin treating tank waste at Hanford. Direct feed means separating the waste at a tank farm to remove the more radioactive portion (i.e., solids and cesium) so that the resulting low-activity (less radioactive) waste can be fed directly to the Waste Treatment and Immobilization Plant's Low-Activity Waste Facility. Starting DFLAW will require a singular, intensive leadership focus, along with a sustained, collective commitment to excellence and teamwork by the Department and its contractors. Major upgrades to Hanford's infrastructure will occur prior to startup. Supporting DFLAW operations requires significant integration between the DFLAW facilities - the Waste Treatment Plant, Hanford's tank farms, effluent treatment facilities, disposal facilities - and between all of the site contractors to achieve success. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Creb5 controls its own expression and directly induces the joint interzone regulatory program

Prior studies have indicated that the transcription factor Creb5 is expressed in the joint interzone, which contains the progenitors for all synovial joint tissues in both mouse and human embryos. In the absence of Creb5 function, most synovial joint interzones fail to form and the cartilage templates in the long bones remain fused. This earlier work did not clarify whether Creb5 initiates a cascade of signaling molecules, such as growth and differentiation factor 5 (Gdf5) and Wnt-family members, that in turn induce the formation of the joint interzone, or instead directly activates the expression of joint interzone markers. In the present study, an integrative analysis of the transcriptome, chromatin accessibility, and Creb5-occupancy in joint progenitors revealed that Creb5 directly binds to both its own two promoters and to the regulatory regions of Gdf5 and Sfrp2, each of whose expression in the joint interzone is Creb5-dependent. Functional enhancer analysis indicated that Creb5 binding sites in either the two Creb5 promoters, or in Gdf5 and Sfrp2 regulatory elements are necessary for these sequences to drive transgene expression in the developing synovial joints. While Creb5 directly drives Gdf5 and Sfrp2 expression in the inner joint interzone, Creb5 activates Barx1 expression specifically in the outer joint interzone. Our findings indicate that Creb5 initiates a regulatory network that both promotes the formation of synovial joints, and subsequently activates distinct transcriptional targets in the inner versus the outer regions of the joint interzone, thus regionalizing gene expression in the developing joint.

Zhang, Cheng-Hai↗

Integrated and Advanced Lighting Controls: The Next Frontier in Energy Savings?

Lighting energy use has significantly declined as a portion of overall building energy usage due largely to the uptake of more efficient light-emitting diode technology. Although the per unit cost of lighting controls has declined, the installation and use of lighting controls are low and the installation and use of advanced controls are abysmally low. Increased use of advanced and connected lighting controls, and the ability to integrate lighting with other building systems (e.g., heat and air, plug loads, miscellaneous loads) that make the building “smarter,” offer the potential for additional energy savings. Studies into the performance of new, advanced lighting control technologies in commercial buildings have generated new findings. Although each field evaluation has interesting results individually, an analysis of their collective findings across a spectrum of commercial building types will help establish the current state of the technology and implications related to market readiness. This paper will analyze results from available field evaluation studies (recently completed as well as ongoing) of retrofit sites and share findings and insights including: • The amount of energy savings that may be expected from these systems. • Cost effectiveness, monetization, and cost points of these systems. • Ideal characteristics of these systems the most viable. • Lessons learned from the installation, commissioning, and occupant response of these systems. The results will support Department of Energy research investments and help inform efficiency programs of the potential of these emerging technologies and how they may fit within the clean energy future.

Myer, Michael↗

Occupational Radiation Exposure Report for Calendar Year 2023

The U.S. Department of Energy Occupational Radiation Exposure Report for Calendar 2023 presents the results of analyses of occupational radiation exposures at the U.S. Department of Energy (DOE), including the National Nuclear Security Administration (NNSA) operations, during calendar year 2023. This report includes occupational radiation exposure data for over 80,000 DOE Federal employees, contractors, and subcontractors as well as members of the public who have worked in or entered controlled areas monitored for exposure to radiation. DOE publishes this annual report to provide DOE Management, Program Offices, workers, health physicists, and other stakeholders an evaluation of DOE-wide performance regarding compliance with Title 10 of the Code of Federal Regulations (CFR) Part 835, Occupational Radiation Protection (10 CFR 835) radiation exposure limits and adherence to as low as reasonably achievable principles. This report provides a discussion regarding radiation protection and exposure reporting requirements. It also includes calendar year (CY) 2023 information and analyses regarding aggregate, individual, site, DOE Program, transient individuals’ dose, as well as a historical review of DOE exposure data. DOE continues to be diligent in protecting its workers and the public from exposure to radiation from DOE operations as illustrated by the results contained in this report.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Impact Noise Monitoring at Site 9940: RD-24 Shots

The purpose of this sampling event was to determine if the observation point (inside the MFCP) could be relocated from 74 feet away to 21 feet from ground zero and to determine how much attenuation is provided by the MFCP. The MFCP provides noise attenuation to ensure Members of the Workforce (MOW) exposure to impact noise is below the Occupational Exposure Limit (OEL) of 140 dBC. The MFCP will be used for future tests under similar configurations. Please note that during each test shot, MOW was located inside MFCP that was 74 feet from ground zero and donned hearing protection (e.g., ear plugs with a minimum noise reduction rating of 23).

42 ENGINEERING↗

From models to reality: a systematic review on simulated and measured residential heat pump energy savings

High-performance HVAC solutions are central to residential energy management. A substantial share of these are electric, reversible-cycle systems, with heat pumps representing the largest portion of current and near-term adoption. This review synthesizes peer-reviewed and grey literature on residential space heating and cooling heat pumps. The academic literature is dominated by modeling (73.8%), with limited field measurement (13.1%). Grey literature from United States serve as a supplemental resource providing measured savings. Conversions from electric-resistance heating consistently show the largest site energy reductions, while oil/propane baselines yield moderate savings, and gas baseline scenario often deliver small and region-dependent savings. This study cross-checks the grey literature measured data with simulation data filtered from the ResStock dataset. The comparison indicates a discrepancy between simulations and measured data: simulated site EUIs are typically lower than measured EUIs, but percentage energy savings fall in similar ranges, implying simulations capture directional effects while underestimating energy use. Factors associated with variability and model–measurement differences include system characterization and control representation (e.g., backup heat engagement, thermostat/setpoint strategies, commissioning/installation quality), occupant behavior, weather normalization, metering scope, and envelope characterization. This paper also outlines the proposed methodology for comparing simulation and measured data for heat pumps. It emphasizes the metrics used for comparison and units harmonization, building characteristics matching, and compact metadata are needed for simulations to match measured data. The proposed methodology is expected to improve the credibility of simulated savings as measured evidence grows.

Yu, Lili↗

Challenges and Opportunities Specific to Microreactors: Compact and Light-Weight Shielding During Operation and Transportation

The problem of designing a shield for a mobile microreactor has been addressed. The principal challenges encountered in this endeavor are the dual goals of increasing radiation protection and decreasing weight. It is recognized that these two goals are contradictory. Increasing shielding naturally increases weight. Conversely, decreasing weight naturally calls for decreasing material inventory, including possibly decreasing shield mass. The operational and regulatory drivers for shielding and transportation constraints are identified and summarized. The main constraints pertain to volume, mass, radiation dose, material feasibility and availability, and decommissioning expectations. The latter are limits on residual contamination and dose rates after the reactor is removed. Progress toward solving the challenge of shielding a transportable microreactor is made by considering a tungsten tetraboride (WB4) shell surrounding the reactor vessel. The shield and a generic microreactor were modeled using the MCNP code. It was determined that the presence of a 16-cm-thick WB4 shield reduces the dose equivalent rate during operations to 3.6 mrem/h just outside of a concrete vault and dome and soil berm surrounding the reactor, which is very near the occupational dose rate limits. Without the WB4 layer, the dose rate at the same location outside the berm would be 120 mrem/h. Most importantly, the presence of the WB4 shield substantially protects the surrounding concrete and soil from activation, thus decreasing the duration of administrative control for the site following removal of the reactor from 16 to 3.4 years. At that point, the site may be decommissioned and returned to unrestricted public access. A limitation on the incorporation of a WB4 shield as an intrinsic component of a microreactor is that it results in a design that is transportable only by using the largest road conveyances and that the load would require special permits for transit through the U.S. highway system. New directions for further improvements and possibly more effective solutions to the shielding problem of a mobile microreactor are discussed in the conclusion section.

Microreactor↗

Extending the Gutzwiller approximation to intersite interactions

In this work, we develop an extension of the Gutzwiller approximation (GA) formalism that includes the effects of Coulomb interactions of arbitrary range (including density density, exchange, pair hopping, and Coulomb-assisted hopping terms). This formalism reduces to the ordinary GA formalism for the multiband Hubbard models in the presence of only local interactions. This is accomplished by combining the 1 / z expansion—where z is the coordination number, and only the leading-order terms contribute in the limit of infinite dimensions—with a P R † P R - I expansion, where P R is the Gutzwiller projector on the site R . Furthermore, the method is conveniently formulated in terms of a Gutzwiller Lagrange function. We apply our theory to the extended single-band Hubbard model. Similarly to the usual Brinkman-Rice mechanism, we find a Mott transition. A valence skipping transition is observed, where the occupation of the empty and doubly occupied states for the Gutzwiller wave function is enhanced with respect to the uncorrelated Slater determinant wave function.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

End-Use Savings Shapes Measure Documentation: Demand Control Ventilation

This documentation focuses on a single end-use savings shape measure - Demand Control Ventilation (DCV). DCV can save energy by reducing the rate at which outdoor air (OA) is delivered during periods of less-than-design occupancy. This measure will enable DCV for air loops using applicable HVAC system types (all except dedicated outdoor air systems [DOAS], packaged systems, or that have an energy recovery ventilator [ERV]) and serving applicable space types (all except kitchens, dining areas, patient spaces, mechanical rooms, stairwells and corridors, or high exhaust space types) using model occupancy schedules to control the DCV. The measure is applicable to 72.7% of the stock floor area. As office buildings outside of California in ComStock are modeled using a single, whole-building space type, DCV is not applied to these building types. The DCV measure demonstrates 2.6% total site energy savings (119 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Singleplex, multiplex and pooled sample real-time RT-PCR assays for detection of SARS-CoV-2 in an occupational medicine setting

Abstract For workplaces which cannot operate as telework or remotely, there is a critical need for routine occupational SARS-CoV-2 diagnostic testing. Although diagnostic tests including the CDC 2019-Novel Coronavirus (2019-nCoV) Real-Time RT-PCR Diagnostic Panel (CDC Diagnostic Panel) (EUA200001) were made available early in the pandemic, resource scarcity and high demand for reagents and equipment necessitated priority of symptomatic patients. There is a clearly defined need for flexible testing methodologies and strategies with rapid turnaround of results for (1) symptomatic, (2) asymptomatic with high-risk exposures and (3) asymptomatic populations without preexisting conditions for routine screening to address the needs of an on-site work force. We developed a distinct SARS-CoV-2 diagnostic assay based on the original CDC Diagnostic Panel (EUA200001), yet, with minimum overlap for currently employed reagents to eliminate direct competition for limited resources. As the pandemic progressed with testing loads increasing, we modified the assay to include 5-sample pooling and amplicon target multiplexing. Analytical sensitivity of the pooled and multiplexed assays was rigorously tested with contrived positive samples in realistic patient backgrounds. Assay performance was determined with clinical samples previously assessed with an FDA authorized assay. Throughout the pandemic we successfully tested symptomatic, known contact and travelers within our occupational population with a ~ 24–48-h turnaround time to limit the spread of COVID-19 in the workplace. Our singleplex assay had a detection limit of 31.25 copies per reaction. The three-color multiplexed assay maintained similar sensitivity to the singleplex assay, while tripling the throughput. The pooling assay further increased the throughput to five-fold the singleplex assay, albeit with a subtle loss of sensitivity. We subsequently developed a hybrid ‘multiplex-pooled’ strategy to testing to address the need for both rapid analysis of samples from personnel at high risk of COVID infection and routine screening. Herein, our SARS-CoV-2 assays specifically address the needs of occupational healthcare for both rapid analysis of personnel at high-risk of infection and routine screening that is essential for controlling COVID-19 disease transmission. In addition to SARS-CoV-2 and COVID-19, this work demonstrates successful flexible assays developments and deployments with implications for emerging highly transmissible diseases and future pandemics.

60 APPLIED LIFE SCIENCES↗

A Rapid Population Assessment Method for Wild Pigs Using Baited Cameras at 3 Study Sites

ABSTRACT Reliable and efficient population estimates are a critical need for effective management of invasive wild pigs ( Sus scrofa ). We evaluated the use of 10‐day camera grids for rapid population assessment (RPA) of wild pigs at 3 study sites that varied in vegetation communities and wild pig densities. Study areas included Buck Island Ranch, Florida; Tejon Ranch, California; and the Savannah River Site, South Carolina, USA, during 2016–2018. Rapid population assessments grids were composed of baited camera traps spaced approximately 500 or 750 m apart. Two RPA grids were deployed per study site and each grid was deployed twice (4–6 months apart) to assess changes in response to season or population control efforts. We assessed the ability of RPA grids to track population trends, how camera number influenced estimate precision, and how relative abundance indices related to density estimates. We detected changes in occupancy probability, detection probability, and N‐mixture estimates following removal operations and between seasons, but the ability of RPA grids to track population trends was dependent on the statistical method used and number of cameras traps. Increasing the number of cameras traps used in RPA grids increased precision, and these results can be used in determining survey design and estimate choice. We found that estimates of occupancy probability, detection probability, and N‐mixture estimates were positively correlated with spatially explicit capture–recapture density estimates. Thus, these less labor‐intensive estimates from RPA grids showed potential to index the relative abundance of wild pigs in some systems. Our evaluation of RPAs indicates that using study‐specific combinations of statistical method and number of cameras can provide a useful tool for monitoring wild pig presence, tracking population trends, and evaluating the effectiveness of management actions. © 2020 The Wildlife Society.

Schlichting, Peter E.↗

TA-03-0016 Ion Beam Facility D&D: Sphere of Influence [Slides]

TA-03-0016 Ion Beam Facility: This structure is 70 years old and has been vacant since 1994 and was excessed in 1999. The Ion Beam Facility (IBF) was built in 1953 to support essential post-World War II scientific research and houses LANL's original vertical and tandem Van de Graaff accelerators. The vertical Van de Graaff accelerator was built under the direction of Joseph McKibben from 1948 to 1952 and was used for applied nuclear physics experiments. The Ion Beam facility is considered by NNSA as one of its highest risk process contaminated facilities within the complex. Ion Beam is a radiological facility adjacent to the LANL Occupational Medicine Facility on the south side of TA-3, the most populated technical area at LANL. It poses an undesirable fire risk, especially given its close location to a rugged wooded canyon and difficulties in fighting a wildland fire in such a location. Demolition of this structure will provide a constructable site for critical mission radiological laboratory spaces.

99 GENERAL AND MISCELLANEOUS↗

Energy impacts of nationwide window upgrades in commercial buildings

This report presents comprehensive estimates of the energy impacts of nationwide commercial building window upgrades in the United States, using a conservative approach. Windows play a substantial role in determining building energy use and occupant experience. Estimates point to commercial building windows impacting loads that represent more than 6 quads (approximately 6%) of annual primary energy use in the U.S. (Harris, 2022). Beyond heating and cooling loads, windows also have effects on lighting and occupant comfort. The fastest route to improving the energy efficiency of windows in U.S. buildings is upgrading or replacing windows in existing buildings. This is due to poor performance of windows in older existing buildings compared to most new construction, low levels of window replacement, and long window service life compared to energy-using building components. Nationwide window upgrades were considered using the following technologies: • Secondary glazing systems • Double pane (clear and tinted) • Triple pane (clear and tinted) • Electrochromic glazing Nationwide upgrades provide on the order of 4%–6% site energy savings in typical buildings, or up to 26% in buildings with the highest savings potential. Electrochromic windows, with their ability to adapt dynamically to environmental conditions, can provide additional benefits, ranging from median savings of 7.2% in buildings with window to wall ratio (WWR) greater than 10% and up to 28% for some buildings. Savings increase substantially for buildings with higher WWR. This study’s approach focused on isolating the direct energy benefits from improvement in window performance, and does not take into account the following additional benefits from window retrofits, which are likely to be substantial: • Managing peak demand and enabling HVAC equipment downsizing. • Energy savings from customizing upgrades to building type and climate. • Energy savings and comfort improvements resulting from post-retrofit reductions in air leakage. • Non-energy benefits, such as occupant comfort and resilience during extreme weather.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Remote operation of the DIII-D National Fusion Facility

Abstract Full remote scientific operation of the DIII-D National Fusion Facility is now possible through significant advances in the computer science hardware and software infrastructure made over the last decade. Capabilities around information visualization, data movement, and communication have all been enhanced. The level of capability deployed to remotely operate DIII-D required an infrastructure advancement over what had previously been achieved in the fusion community. The large quantity of real-time data that is automatically displayed on DIII-D’s control room screens can now be visualized by remote participants via web-based applications. New audio/video solutions using the VoIP and instant messaging application Discord have been implemented to mimic the dynamic and ad-hoc scientific conversations that are critical in successfully operating an experimental campaign. Discord’s ability for a user to rapidly move between audio channels, text with images, and share screens is a significant enhancement over traditional videoconferencing tools. In addition, multiple combinations of broadcast audio are made available via a web-based application to allow remote participants to simultaneously listen to general announcements/sounds while conducting their own specific conversations. Secure methodologies have been put into place to allow remote control of hardware including DIII-D’s plasma control system application. Secure methods also included the ability of the on-site team to closely coordinate their work with remote team members which has been enhanced through extensions to the wireless network and the use of tablet computers for audio/video/screen sharing. However, no amount of software can fully replace the need for ‘hands on hardware.’ This infrastructure was severely stress tested during the COVID-19 pandemic where occupancy of the DIII-D control room was restricted. Operational efficiency during the pandemic, measured in discharges per hour, remained high (3.8 ± 0.8) compared to values obtained pre-pandemic (3.7 ± 0.8).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

HIVE™ [SWR-19-36]

The HIVE™ platform is a mobility services simulation platform developed to provide insight on the energy, infrastructure, service, and economic outcomes of various mobility as a service (MaaS) options. The HIVE platform takes a set of spatiotemporal travel origin-destination pairs and simulates the operation of a predefined mobility service fleet, incorporating request pooling, and various operational and charging behaviors. Hive specializes at modeling fleets of automated electric vehicles (AEVs) and can be used to site and size direct current fast charge (DCFC) stations and measure grid impacts of large-scale AEV fleets serving real-world MaaS trip demand (similar to taxis, Uber, Lyft, etc.). Potential outcomes from a Hive simulation include level of service, total vehicle miles traveled (VMT), deadheading (zero passenger) miles, simultaneous and total energy loads, average occupancy, and more. Hive is developed to generalize to new regions and can be customized to handle many scenarios and operating conditions.

Rames, Clement↗

Competing Interests and Creating Value - Balancing Durable and Enforceable Institutional Controls with Beneficial Reuse - 20320

US DOE LM has various real property interests at the 100 sites within its current portfolio, with an anticipated total of 127 sites within the next 5 years. Each site has its own narrative with respect to the real property assets. Since the regulatory time frame for long-term surveillance and maintenance activities at some sites can be in perpetuity, durable and effective instruments and documentation are necessary to support LM's unique mission as a federal land manager and steward. More than half of the sites currently in LM's inventory do not allow unrestricted use, and institutional controls (ICs) are required to limit human and environmental exposures to residual contamination. LM's Asset Management program balances protection of human health and the environment with a goal of optimizing its land portfolio through mitigation of risk, limiting liability, and creating value, whether tangible or intangible, in these types of assets. The IC layering strategy utilizes multiple types, restrictions, and legal authorities to protect human health and the environment. This layering strategy influences the transition of these properties into LM's portfolio to assess potential beneficial reuses. The LM's beneficial reuse program aims to repurpose former contaminated sites to restore the environment, protect the public health, revitalize communities, and spur economic growth. LM strives to create value in a perceived valueless asset and reevaluates and revisits the potential opportunities for these sites as long-term surveillance and maintenance activities are performed and objectives are achieved. Beneficial reuse also promotes protectiveness by ensuring activities are compatible with long-term maintenance and protection of public health and the environment as well as ensuring activities are environmentally sound by retaining good stewardship of natural resources. LM has recently revised both the Institutional Control Program Guidance and its Beneficial Reuse Management Plan to integrate the issues of land use with ICs, creating value in these impaired assets. This paper presents the following topics: (1) a general overview of LM's IC and beneficial reuse programs; (2) the unique aspects of each of these programs as a result of the multiple regulatory requirements and programs that affect LM sites; (3) case studies of LM sites to show examples of how LM created value while complying with the ICs and layering strategies; and (4) the most common challenges to beneficial reuses at LM sites and potential options for value creation in impaired assets. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ecological information and approaches needed for risk communication dialogs for acute or chronic environmental crises

Scientists, social scientists, risk communicators, and many others are often thrust into a crisis situation where they need to interact with a range of stakeholders, including governmental personnel (tribal, U.S. federal, state, local), local residents, and other publics, as well as other scientists and other risk communicators in situations where information is incomplete and evolving. This paper provides: (1) an overall framework for thinking about communication during crises, from acute to chronic, and local to widespread, (2) a template for the types of ecological information needed to address public and environmental concerns, and (3) examples to illustrate how this information will aid risk communicators. The main goal is providing an approach to the knowledge needed by communicators to address the challenges of protecting ecological resources during an environmental crisis, or for an on-going, chronic environmental issue. To understand the risk to these ecological resources, it is important to identify the type of event, whether it is acute or chronic (or some combination of these), what receptors are at risk, and what stressors are involved (natural, biological, chemical, radiological). For ecological resources, the key information a communicator needs for a crisis is whether any of the following are present: threatened or endangered species, species of special concern, species groups of concern (e.g., neotropical bird migrants, breeding frogs in vernal ponds, rare plant assemblages), unique or rare habitats, species of commercial and recreational interest, and species/habitats of especial interest for medicinal, cultural, or religious activities. Communication among stakeholders is complicated with respect to risk to ecological receptors because of differences in trust, credibility, empathy, perceptions, world view valuation of the resources, and in many cases, a history of misinformation, disinformation, or no information. Exposure of salmon spawning in the Columbia River to hexavalent chromium from the Hanford Site is used as an example of communication challenges with different stakeholders, including Native Americans with Tribal Treaty rights to the land.

54 ENVIRONMENTAL SCIENCES↗

Data-driven evaluation of HVAC operation and savings in commercial buildings

Commercial buildings consumed 36% of electricity, or 1.35 trillion kWh, in the United States in 2017, and almost 30% of this energy was wasted. Much of this loss can be attributed to inefficient heating ventilation and air con­ditioning (HVAC) systems. By improving the operational conditions of HVAC, significant savings can be achieved. However, most buildings and building equipment do not use costly sub-meters to monitor and address performance issues, and on-site auditing can be expensive and insufficient. Alternatively in this study, we propose a data-driven method to identify savings opportunities using only whole building meter data and without setting foot in the building. For this purpose, we introduced two algorithms that virtually quantify the value of a thermostat setpoint setback and HVAC rescheduling. Additionally, we developed novel methods for detecting occupancy patterns and quantifying the baseload of the HVAC operation. Using a clustering algorithm, we identified those buildings for which HVAC savings was significant and further categorized the buildings based on their potential for savings. A population study of over 432 commercial buildings demonstrated a median percentage energy savings of 1.6% from a baseload reduction and 2.1% from HVAC rescheduling. Additionally, results indicate that retail buildings have the highest potential for savings among the building types studied.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗