Search NASA⌕ Search

SEARCH · Search NASA

Results for “Soft thresholding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Evaluating iterative reconstruction performance in computed tomography

Purpose: Iterative reconstruction (IR) offers notable advantages in computed tomography (CT). However, its performance characterization is complicated by its potentially nonlinear behavior, impacting performance in terms of specific tasks. This study aimed to evaluate the performance of IR with both task-specific and task-generic strategies. Methods: The performance of IR in CT was mathematically assessed with an observer model that predicted the detection accuracy in terms of the detectability index (d′). d′ was calculated based on the properties of the image noise and resolution, the observer, and the detection task. The characterizations of image noise and resolution were extended to accommodate the nonlinearity of IR. A library of tasks was mathematically modeled at a range of sizes (radius 1–4 mm), contrast levels (10–100 HU), and edge profiles (sharp and soft). Unique d′ values were calculated for each task with respect to five radiation exposure levels (volume CT dose index, CTDI{sub vol}: 3.4–64.8 mGy) and four reconstruction algorithms (filtered backprojection reconstruction, FBP; iterative reconstruction in imaging space, IRIS; and sinogram affirmed iterative reconstruction with strengths of 3 and 5, SAFIRE3 and SAFIRE5; all provided by Siemens Healthcare, Forchheim, Germany). The d′ values were translated into the areas under the receiver operating characteristic curve (AUC) to represent human observer performance. For each task and reconstruction algorithm, a threshold dose was derived as the minimum dose required to achieve a threshold AUC of 0.9. A task-specific dose reduction potential of IR was calculated as the difference between the threshold doses for IR and FBP. A task-generic comparison was further made between IR and FBP in terms of the percent of all tasks yielding an AUC higher than the threshold. Results: IR required less dose than FBP to achieve the threshold AUC. In general, SAFIRE5 showed the most significant dose reduction potentials (11–54 mGy, 77%–84%), followed by SAFIRE3 (7–36 mGy, 50%–61%) and IRIS (6–26 mGy, 37%–50%). The dose reduction potentials highly depended on task size and task contrast, with tasks of lower contrasts and smaller sizes, i.e., more challenging tasks, indicating higher dose reductions. Softer edge profile showed higher dose reduction potentials with SAFIRE3 and SAFIRE5, but not with IRIS. The task-generic comparison between IR and FBP demonstrated the overall superiority of IR performance, as IR allowed a larger percent of tasks to exceed the threshold AUC: IRIS, 8%–12%; SAFIRE3, 10%–16%; and SAFIRE5, 20%–33%. The improvement with IR was generally more pronounced at lower dose levels. Conclusions: Expanding beyond traditional contrast and noise based assessments of IR, we performed both task-specific and task-generic evaluations of IR performance. The task-specific evaluation demonstrated the dependency of IR’s dose reduction potential on task attributes, which can be employed to optimize IR for clinical indications with specific range of size and contrast. The task-generic evaluation demonstrated IR’s overall superiority over FBP in terms of the range of tasks exceeding a threshold performance level, which can be employed for general comparisons between algorithms.

60 APPLIED LIFE SCIENCES↗

Formation of Power-law Electron Energy Spectra in Three-dimensional Low- β Magnetic Reconnection

While observations have suggested that power-law electron energy spectra are a common outcome of strong energy release during magnetic reconnection, e.g., in solar flares, kinetic simulations have not been able to provide definite evidence of power-laws in energy spectra of nonrelativistic reconnection. By means of 3D large-scale fully kinetic simulations, we study the formation of power-law electron energy spectra in nonrelativistic low-β reconnection. We find that both the global spectrum integrated over the entire domain and local spectra within individual regions of the reconnection layer have power-law tails with a spectral index p ~ 4 in the 3D simulation, which persist throughout the nonlinear reconnection phase until saturation. In contrast, the spectrum in the 2D simulation rapidly evolves and quickly becomes soft. We show that 3D effects such as self-generated turbulence and chaotic magnetic field lines enable the transport of high-energy electrons across the reconnection layer and allow them to access several main acceleration regions. This leads to a sustained and nearly constant acceleration rate for electrons at different energies. Here, we construct a model that explains the observed power-law spectral index in terms of the dynamical balance between particle acceleration and escape from main acceleration regions, which are defined based upon a threshold for the curvature drift acceleration term. This result could be important for explaining the formation of power-law energy spectrum in solar flares.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurements of Active-Region Global Nonpotentiality for Prediction of Coronal Mass Ejections

We introduce two quantitative measures of the global nonpotentiality of predominantly bipolar active regions and explore their usefulness as indicators of whether an active region is likely to produce coronal mass ejections. The two measures, length of strong-field strong-shear main neutral line (L (sub ss)) and global net current (I (sub N)), are obtained directly from vector magnetograms of the regions. From Marshall Space Flight Center vector magnetograms and Yohkoh Soft X-ray Telescope coronal X-ray images of four active regions, we find that (1) L (sub ss) and I (sub N) are each a useful indicator of an active region's likely CME (Coronal Mass Ejections) productivity, (2) L (sub ss) and I (sub N) may be more reliable predictors of the CME productivity of active regions than is the presence or absence of sigmoidal structure in X-ray images of the regions, and (3) L (sub ss) and I (sub N) may have threshold values above which CME production is likely and below which CME production is unlikely.

Falconer, D. A.↗

Threshold and flavor effects in the renormalization group equations of the MSSM: Dimensionless couplings

In a theory with broken supersymmetry, gaugino couplings renormalize differently from gauge couplings, as do higgsino couplings from Higgs boson couplings. As a result, we expect the gauge (Higgs boson) couplings and the corresponding gaugino (higgsino) couplings to evolve to different values under renormalization group evolution. We reexamine the renormalization group equations (RGEs) for these couplings in the minimal supersymmetric standard model (MSSM). To include threshold effects, we calculate the {beta} functions using a sequence of (nonsupersymmetric) effective theories with heavy particles decoupled at the scale of their mass. We find that the difference between the SM couplings and their SUSY cousins that is ignored in the literature may be larger than two-loop effects which are included, and further that renormalization group evolution induces a nontrivial flavor structure in gaugino interactions. We present here the coupled set of RGEs for these dimensionless gauge and Yukawa-type couplings. The RGEs for the dimensionful soft-supersymmetry-breaking parameters of the MSSM will be presented in a companion paper.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

General gauge mediation at the weak scale

We completely characterize General Gauge Mediation (GGM) at the weak scale by solving all IR constraints over the full parameter space. This is made possible through a combination of numerical and analytical methods, based on a set of algebraic relations among the IR soft masses derived from the GGM boundary conditions in the UV. We show how tensions between just a few constraints determine the boundaries of the parameter space: electroweak symmetry breaking (EWSB), the Higgs mass, slepton tachyons, and left-handed stop/sbottom tachyons. While these constraints allow the left-handed squarks to be arbitrarily light, they place strong lower bounds on all of the right-handed squarks. Meanwhile, light EW superpartners are generic throughout much of the parameter space. This is especially the case at lower messenger scales, where a positive threshold correction to m h coming from light Higgsinos and winos is essential in order to satisfy the Higgs mass constraint.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cooling of neutron stars in soft x-ray transients

Thermal states of neutron stars in soft x-ray transients (SXRTs) are thought to be determined by “deep crustal heating” in the accreted matter that drives the quiescent luminosity and cooling via emission of photons and neutrinos from the interior. In this work, we assume a global thermal steady state of the transient system and calculate the heating curves (quiescent surface luminosity as a function of mean accretion rate) predicted from theoretical models, taking into account variations in the equations of state, superfluidity gaps, thickness of the light element layer, and a phenomenological description of the direct Urca threshold. We further provide a statistical analysis on the uncertainties in these parameters, and compare the overall results with observations of several SXRTs, in particular the two sources containing the coldest (SAX J1808.4-3658) and the hottest (Aql X-1) neutron stars. Interpretation of the observational data indicates that the direct Urca process is required for the most massive stars and also suggests small superfluid gaps.

79 ASTRONOMY AND ASTROPHYSICS↗

Samarkand complex setup for investigation of cosmic ray variation in the energy range of 7 10 (9) - 10 (15) eV

The Samarkand complex setup is aimed at the study of cosmic ray variations in a wide energy range from 7 billion eV (which corresponds to the geomagnetic threshold in the region of Samarkand) up to approx 10 to the 15th power to 10 to the 16th power eV. The setup consists of four 6-counter sections of neutron supermonitor with counters SNM-15 and 48 scintillator detectors (1 sq m each) placed under and above the supermonitor. The effective area of the setup for recording neutrons and muons is 24 sq m. The setup can register time variations of the following cosmic ray components: (1) the total neutron counting rate, (2) counting rates for neutrons of different multiplicity, (3) soft-muon fluxes, (4) hard-muon fluxes at various zenith and azimuth angles, (5) electron-photon component, (6) extensive air showers (EAS) induced by primary particles in a wide energy range and accompanied or not accompanied by muons and neutrons.

Dorman, L. I.↗

Single event upset vulnerability of selected 4K and 16K CMOS static RAM's

Upset thresholds for bulk CMOS and CMOS/SOS RAMS were deduced after bombardment of the devices with 140 MeV Kr, 160 MeV Ar, and 33 MeV O beams in a cyclotron. The trials were performed to test prototype devices intended for space applications, to relate feature size to the critical upset charge, and to check the validity of computer simulation models. The tests were run on 4 and 1 K memory cells with 6 transistors, in either hardened or unhardened configurations. The upset cross sections were calculated to determine the critical charge for upset from the soft errors observed in the irradiated cells. Computer simulations of the critical charge were found to deviate from the experimentally observed variation of the critical charge as the square of the feature size. Modeled values of series resistors decoupling the inverter pairs of memory cells showed that above some minimum resistance value a small increase in resistance produces a large increase in the critical charge, which the experimental data showed to be of questionable validity unless the value is made dependent on the maximum allowed read-write time.

Kolasinski, W. A.↗

Identification and repair of intermittent cable faults in nuclear power plants - 131

The nuclear industry uses cable circuits as an integral part of a plant's reactor protection system (RPS), instrumentation and control (I and C) and power distribution systems. The reliability of these systems is critical for continued operation of the world's aging nuclear fleet, as well as for safe shutdown of the reactor. When intermittent faults occur in cable circuits, the symptom of the problem often appears and disappears in milliseconds while the aftereffects can result in spurious alarms and automatic actuation of safety systems. Problems are compounded when component degradation causes a cable circuit to transmit inaccurate information that does not represent actual plant operating conditions. The root cause of intermittent cable circuit operation can include degradation of cable and connectors from heat, humidity, radiation, and vibration. Unlike hard faults (which are constant open or short circuits), intermittent faults are defined as a temporary change in impedance that may only last for a few milliseconds. While less disruptive than hard faults, signal spiking from intermittent faults can often lead to alarm conditions and reactor trips. A soft fault is defined as a subtle variation the electrical characteristics of the circuit that still permit the continued operation of the circuit. A soft fault may be a precursor to a hard fault due to continued degradation of the fault over time. The focus of this paper is the description of a cable testing system that can be connected to an active, low frequency circuit and continuously monitor electrical characteristics using the time domain reflectometry (TDR) technique until an intermittent impedance change occurs. This technique uses the difference in frequency response of the circuit and the TDR to isolate the TDR signature from the active circuit data . When a momentary impedance change occurs that exceeds a preconfigured limit threshold, the distance to fault data is automatically overlaid with the healthy baseline reference and stored in a database for diagnosis and repair. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Spheres to jets tuning event shapes with 5d simplified models

Hidden sectors could give rise to a wide variety of events at the LHC. Confining hidden sectors are known to engender events with a small number of jets when they are weakly-coupled at high energies, and quasi-spherical soft unclustered energy patterns (SUEPs) when they are very strongly-coupled (large ‘t Hooft coupling) at high energies. The intermediate regime is murky, and could give rise to signals hiding from existing search strategies. While the intermediate coupling regime is not calculable, it is possible to pursue a phenomenological approach in which one creates signals that are intermediate between spherical and jetty. We propose a strategy for generating events of this type using simplified models in extra dimensions. The degree to which the event looks spherical is related to the number of decays produced near kinematic threshold. We provide an analytic understanding of how this is determined by parameters of the model. To quantify the shape of events produced with this model, we use a recently proposed observable - event isotropy - which is a better probe of the spherical regime than earlier event shape observables.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Arakelian 564: An XMM-Newton View

We report on two XMM-Newton observations of the bright narrow-line Seyfert 1 galaxy Ark 564 taken one year apart (2000 June and 2001 June). The 0.6-10 keV continuum is well described by a soft blackbody component (kTau approximately equal 140-150 eV) plus a steep power law (Tau approximately equal to 2.50-2.55). No significant spectral changes are observed between the two observations, although the X-ray flux in the second observation is approximately equal to 40-50 per cent lower. In both observations we detect a significant absorption edge at a rest-frame energy of approximately equal to 0.73 keV, corresponding to O VII. The presence of the absorption feature is confirmed by a simultaneous Chandra grating observation in 2000 June, although the best-fitting edge threshold is at a slightly lower energy in the Chandra data, possibly because of a different parameterization of the underlying X-ray continuum. We find tentative evidence for a broad iron emission line in the 2000 June observation. The results from an analysis of the power spectral density (PSD) function are also presented. The present XMM-Newton data support the idea that the PSD shown two breads, although the location of the high-frequency break requires further constraints.

Vignali, Cristian↗

Guiding thermomagnetic avalanches with soft magnetic stripes

Here, we demonstrate the potential for manipulating the ultrafast dynamics of thermomagnetic flux avalanches (TMA) in superconducting films with soft magnetic stripes deposited on the film. By tuning the in-plane magnetization of the stripes, we induce lines of strong magnetic potentials for Abrikosov vortices, resulting in guided slow motion of vortices along the stripe edges and preferential bursts of TMA along the stripes. Furthermore, we show that transversely polarized stripes can reduce the TMA size by diverting magnetic flux away from the major trunk of the TMA into interstripe gaps. Our data indicate that TMAs are launched from locations with enhanced vortex entry barrier, where flux accumulation followed by accelerated vortex discharge significantly reduces the threshold of the applied field ramping speed required for the creation of TMAs. Finally, vortex-antivortex annihilation at the moving front of an expanding TMA can account for the enhanced TMA activity in the receding branches of the sample's magnetization cycle and the preferred propagation of TMAs into maximum trapped flux regions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Correction of quantification errors in pelvic and spinal lesions caused by ignoring higher photon attenuation of bone in [{sup 18}F]NaF PET/MR

Purpose: MR-based attenuation correction (MRAC) in routine clinical whole-body positron emission tomography and magnetic resonance imaging (PET/MRI) is based on tissue type segmentation. Due to lack of MR signal in cortical bone and the varying signal of spongeous bone, standard whole-body segmentation-based MRAC ignores the higher attenuation of bone compared to the one of soft tissue (MRAC{sub nobone}). The authors aim to quantify and reduce the bias introduced by MRAC{sub nobone} in the standard uptake value (SUV) of spinal and pelvic lesions in 20 PET/MRI examinations with [{sup 18}F]NaF. Methods: The authors reconstructed 20 PET/MR [{sup 18}F]NaF patient data sets acquired with a Philips Ingenuity TF PET/MRI. The PET raw data were reconstructed with two different attenuation images. First, the authors used the vendor-provided MRAC algorithm that ignores the higher attenuation of bone to reconstruct PET{sub nobone}. Second, the authors used a threshold-based algorithm developed in their group to automatically segment bone structures in the [{sup 18}F]NaF PET images. Subsequently, an attenuation coefficient of 0.11 cm{sup −1} was assigned to the segmented bone regions in the MRI-based attenuation image (MRAC{sub bone}) which was used to reconstruct PET{sub bone}. The automatic bone segmentation algorithm was validated in six PET/CT [{sup 18}F]NaF examinations. Relative SUV{sub mean} and SUV{sub max} differences between PET{sub bone} and PET{sub nobone} of 8 pelvic and 41 spinal lesions, and of other regions such as lung, liver, and bladder, were calculated. By varying the assigned bone attenuation coefficient from 0.11 to 0.13 cm{sup −1}, the authors investigated its influence on the reconstructed SUVs of the lesions. Results: The comparison of [{sup 18}F]NaF-based and CT-based bone segmentation in the six PET/CT patients showed a Dice similarity of 0.7 with a true positive rate of 0.72 and a false discovery rate of 0.33. The [{sup 18}F]NaF-based bone segmentation worked well in the pelvis and spine. However, it showed artifacts in the skull and in the extremities. The analysis of the 20 [{sup 18}F]NaF PET/MRI examinations revealed relative SUV{sub max} differences between PET{sub nobone} and PET{sub bone} of (−8.8% ± 2.7%, p = 0.01) and (−8.1% ± 1.9%, p = 2.4 × 10{sup −8}) in pelvic and spinal lesions, respectively. A maximum SUV{sub max} underestimation of −13.7% was found in lesion in the third cervical spine. The averaged SUV{sub mean} differences in volumes of interests in lung, liver, and bladder were below 3%. The average SUV{sub max} differences in pelvic and spinal lesions increased from −9% to −18% and −8% to −17%, respectively, when increasing the assigned bone attenuation coefficient from 0.11 to 0.13 cm{sup −1}. Conclusions: The developed automatic [{sup 18}F]NaF PET-based bone segmentation allows to include higher bone attenuation in whole-body MRAC and thus improves quantification accuracy for pelvic and spinal lesions in [{sup 18}F]NaF PET/MRI examinations. In nonbone structures (e.g., lung, liver, and bladder), MRAC{sub nobone} yields clinically acceptable accuracy.

60 APPLIED LIFE SCIENCES↗

Possible ambiguities in the equation of state for neutron stars

We addressed possible ambiguities on the properties of neutron stars (NSs) estimated in theoretical sides. First, roles of hyperons inside the NS are discussed through various relativistic mean field (RMF) theories. In particular, the extension of SU(6) spin-flavor symmetry to SU(3) flavor symmetry is shown to give rise to the increase of hyperon threshold density, similarly to the Fock term effects in RMF theories. As a result, about 2.0 solar mass is obtained with the hyperons. Second, the effect by the modified f(R) gravity, which leaves a room for the dark energy in the Einstein equation to be taken into account, is discussed for the NS in a strong magnetic field (MF). Our results show that the modified gravity with the Kaluza-Klein electro-magnetism theory expanded in terms of a length scale parameter may reasonably describe the NS in strong MF, so called magnetar. Even the super-soft equation of state is shown to be revived by the modified f(R) gravity.

79 ASTRONOMY AND ASTROPHYSICS↗

The soft gamma-ray spectrum of A0535+26: Detection of an absorption feature at 110 keV by OSSE

We present soft gamma-ray observations by the Oriented Scintillation Spectrometer Experiment (OSSE) on the Compton Gamma Ray Observatory (GRO) of the transient X-ray binary pulsar A0535+26. The observations were made 1994 February 8-17, immediately prior to the peak of a giant outburst. The phase averaged spectrum is complex and cannot be described by a single-component model. We find that structure in the spectrum above 100 keV can best be modeled by an absorption feature near 110 keV, which we interepret as the signature of cyclotron resonant scattering. Because of OSSE's 45 keV threshold, we are unable to make a definitive statement on the presence of a 55 keV absorption line; however, we can conclude that if this line does exist, it must have a smaller optical depth than the line at 110 keV. A first harmonic (=fundamental) cyclotron resonance at 110 keV corresponds to a magnetic field strength at the surface of the neutron star of approximately 1 x 10(exp 13) G (approximately 5 x 10(exp 12) G if the first harmonic is at 55 keV).

Grove, J. E.↗

X-ray-selected M dwarfs and the diffuse X-ray background

A systematic optical identification program was carried out for serendipitous X-ray sources discovered by the Einstein Observatory. A total of 104 were detected above the threshold flux of 3 x 10 to the -13th ergs/sq cm per sec in the 114 sq deg survey region; 11 of these 104 sources are dM stars. Including X-ray-selected M dwarfs from the LMC survey, the Medium Sensitivity Survey, and the Einstein Deep Survey, a dwarf M star composite X-ray spectrum was constructed; the best-fit thermal model yields kT = 1.3 + or - 0.3 keV, consistent with typical active star spectra. An M dwarf X-ray luminosity function was also constructed and it is concluded that the integrated contribution to the diffuse soft (0.28-1.0 keV) X-ray background from such stars is less than 10 percent, a factor of more than about 2 lower than previous estimates. This result is consistent with a limit on the dwarf M star contribution derived from a spectral decomposition of the observed X-ray background spectrum.

Caillault, J.-P.↗

TU-F-CAMPUS-T-02: Risk Assessment of Scattered Neutrons for a Fetus From Proton Therapy of a Brain Tumor During Pregnancy

Purpose: To determine the scattered neutron dose and the resulting risk for a fetus from proton therapy for brain tumors during pregnancy. Methods: Using the Monte Carlo platform TOPAS, the ICRP reference parameters based anthropomorphic pregnancy phantoms for three stages (3-, 6-, 9-month) were applied to evaluate the scattered neutron dose and dose equivalent. To calculate the dose equivalent, organ specific linear energy transfer (LET) based quality factor was used. Treatment plans from both passive scattering (PS) and pencil beam scanning (PBS) methods were considered in this study. Results: For pencil beam scanning, the neutron dose equivalent in the soft tissue of the fetus increases from 1.53x10−{sup 3} to 2.84x10−{sup 3} mSv per treatment Gy with increasing stage of gestation. This is due to scattered neutrons from the patient as the main contaminant source in PBS and a decrease in distance between the soft tissue of the fetus and GTV with increasing stage of gestation. For passive scattering, neutron dose equivalent to the soft tissue of the fetus shows a decrease from 0.17 to 0.13 mSv per treatment Gy in different stages, while the dose to the brain shows little difference around 0.18 mSv per treatment Gy because scattered neutrons from the treatment head contribute predominantly in passive scattering. Conclusion: The results show that the neutron dose to the fetus assuming a prescribed dose of 52.2 Gy is negligible for PBS, and is comparable to the scattered dose (0–10 mSv) from a head and neck CT scan for PS. It can be concluded that the dose to fetus is far lower than the thresholds of malformation, SMR and lethal death. The excess relative risk of childhood cancer induction would be increased by 0.48 and 0.103 using the Oxford Survey of Childhood Cancers and Japanese atomic model, respectively. Changran Geng is supported by the Chinese Scholarship Council (CSC) and the National Natural Science Foundation of China (Grant No. 11475087)

60 APPLIED LIFE SCIENCES↗

Cost-Effectiveness Analysis of Preoperative Versus Postoperative Radiation Therapy in Extremity Soft Tissue Sarcoma

Purpose: Surgery combined with radiation therapy (RT) is the cornerstone of multidisciplinary management of extremity soft tissue sarcoma (STS). Although RT can be given in either the preoperative or the postoperative setting with similar local recurrence and survival outcomes, the side effect profiles, costs, and long-term functional outcomes are different. The aim of this study was to use decision analysis to determine optimal sequencing of RT with surgery in patients with extremity STS. Methods and Materials: A cost-effectiveness analysis was conducted using a state transition Markov model, with quality-adjusted life years (QALYs) as the primary outcome. A time horizon of 5 years, a cycle length of 3 months, and a willingness-to-pay threshold of $50,000/QALY was used. One-way deterministic sensitivity analyses were performed to determine the thresholds at which each strategy would be preferred. The robustness of the model was assessed by probabilistic sensitivity analysis. Results: Preoperative RT is a more cost-effective strategy ($26,633/3.00 QALYs) than postoperative RT ($28,028/2.86 QALYs) in our base case scenario. Preoperative RT is the superior strategy with either 3-dimensional conformal RT or intensity-modulated RT. One-way sensitivity analyses identified the relative risk of chronic adverse events as having the greatest influence on the preferred timing of RT. The likelihood of preoperative RT being the preferred strategy was 82% on probabilistic sensitivity analysis. Conclusions: Preoperative RT is more cost effective than postoperative RT in the management of resectable extremity STS, primarily because of the higher incidence of chronic adverse events with RT in the postoperative setting.

61 RADIATION PROTECTION AND DOSIMETRY↗