Search NASA⌕ Search

SEARCH · Search NASA

Results for “Solid angle”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

High energy cosmic-ray interactions with particles from the Sun

Cosmic-ray protons with energies above 10{sup 16} eV passing near the Sun may interact with photons emitted by the Sun and be excited to a {Delta}{sup +} resonance. When the {Delta}{sup +} decays, it produces pions which further decay to muons and photons which may be detected with terrestrial detectors. A flux of muons, photon pairs (from {pi}{sup 0} decay), or individual high energy photons coming from near the Sun would be a rather striking signature, and the flux of these particles is a fairly direct measure of the flux of cosmic-ray nucleons, independent of the cosmic-ray composition. In a solid angle within 15 deg. around the Sun, the flux of photon pairs is about 1.3x10{sup -3} particles/(km{sup 2{center_dot}}yr), while the flux of muons is about 0.33x10{sup -3} particles/(km{sup 2{center_dot}}yr). This is beyond the reach of current detectors like the Telescope Array, Auger, KASCADE-Grande, or IceCube. However, the muon flux might be detectable by next-generation air-shower arrays or neutrino detectors such as ARIANNA or ARA. We discuss the experimental prospects in some detail. Other cosmic-ray interactions occurring close to the Sun are also briefly discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-contrast laser acceleration of relativistic electrons in solid cone-wire targets

Optimization of electron coupling into small solid angles is of extreme importance to applications, such as Fast Ignition, that require maximum electron energy deposition within a small volume. To optimize this coupling, we use the ultra-high-contrast Trident laser, which remains below intensity of 10 11 W/cm 2 until < 0.1 ns before the main pulse, while still attaining high-energy, 75 J, and peak intensity of 5 x 10 19 W/cm 2 . Using a cone-wire target, we find that the coupling into the 40 μm diameter wire is increased by a factor of 2.7x over the low-contrast Titan laser at similar peak intensity. Full-scale simulations are used to model the laser interaction and quantitatively reproduce the experimental results. These show that increase in coupling is due to both a closer interaction, as well as the reduction of laser filamentation and self-focusing.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Compton Scattering in Ignited Thermonuclear Plasmas

Inertially confined, ignited thermonuclear D-T plasmas will produce intense blackbody radiation at temperatures T > or approx. 20 keV; it is shown that the injection of GeV electrons into the burning core can efficiently generate high-energy Compton scattering photons. Moreover, the spectrum scattered in a small solid angle can be remarkably monochromatic, due to kinematic pileup; a peak brightness in excess of 10{sup 30} photons/(mm{sup 2} mrad{sup 2} s 0.1% bandwidth) is predicted. These results are discussed within the context of the Schwinger field and the Sunyaev-Zel'dovich effect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Incoherent Neutral Pion Photoproduction on {sup 12}C

We present the first detailed measurement of incoherent photoproduction of neutral pions to a discrete state of a residual nucleus. The {sup 12}C({gamma},{pi}{sup 0}){sup 12}C{sub 4.4} {sub MeV}* reaction has been studied with the Glasgow photon tagger at MAMI employing a new technique which uses the large solid angle Crystal Ball detector both as a {pi}{sup 0} spectrometer and to detect decay photons from the excited residual nucleus. The technique has potential applications to a broad range of future nuclear measurements with the Crystal Ball and similar detector systems elsewhere. Such data are sensitive to the propagation of the {delta} in the nuclear medium and will give the first information on matter transition form factors from measurements with an electromagnetic probe. The incoherent cross sections are compared to two theoretical predictions including a {delta}-hole model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Symmetry-Forbidden Electronic State Interference Observed in Angularly Resolved NO{sup +}(A {sup 1{Pi}}) Deexcitation Spectra of the N*O(2{sigma}{sup -1}2{pi}{sup 2}) Resonance

Quantum mechanical interference between different pathways in inner-shell resonance excitation-deexcitation spectra is a realization of a double-slit experiment on the atomic scale. If the intermediate inner-shell resonances are of different symmetries, this interference is symmetry forbidden in the solid-angle-averaged or magic-angle-recorded deexcitation spectra. It has, however, been suggested that interference may by observable in off-magic-angle-recorded spectra. Here, we prove this interference in angularly resolved deexcitation spectra of the 2{sigma}{sup -1}2{pi}{sup 2}({sup 2{Delta}},{sup 2{Sigma}{+-}}) resonances of N*O by a quantitative comparison between ab initio calculations and experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurements of the Electric Form Factor of the Neutron up to Q2 = 3.4 GeV2 using the Reaction He-3(e,e&#x27;n)pp

The electric form factor of the neutron was determined from studies of the reaction \rea{} in quasi-elastic kinematics in Hall A at Jefferson Lab. Longitudinally polarized electrons were scattered off a polarized target in which the nuclear polarization was oriented perpendicular to the momentum transfer. The scattered electrons were detected in a magnetic spectrometer in coincidence with neutrons that were registered in a large-solid-angle detector. More than doubling the $Q^2$-range over which it is known, we find \GEn{}$ = 0.0225 \pm 0.0017 (stat) \pm 0.0024 (syst)$, $0.0200 \pm 0.0023 \pm 0.0018$, and $0.0142 \pm 0.0019 \pm 0.0013$ for $Q^2$ = 1.72, 2.48, and 3.41~\gevsq, respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Observation of Seeded Mn K β Stimulated X-Ray Emission Using Two-Color X-Ray Free-Electron Laser Pulses

Kβ x-ray emission spectroscopy is a powerful probe for electronic structure analysis of 3d transition metal systems and their ultrafast dynamics. Selectively enhancing specific spectral regions would increase this sensitivity and provide fundamentally new insights. Recently we reported the observation and analysis of Kα amplified spontaneous x-ray emission from Mn solutions using an x-ray free-electron laser to create the 1s core-hole population inversion [Kroll et al., Phys. Rev. Lett. 120, 133203 (2018)]. To apply this new approach to the chemically more sensitive but much weaker Kβ x-ray emission lines requires a mechanism to outcompete the dominant amplification of the Kα emission. Here we report the observation of seeded amplified Kβ x-ray emission from a NaMnO 4 solution using two colors of x-ray free-electron laser pulses, one to create the 1s core-hole population inversion and the other to seed the amplified Kβ emission. Comparing the observed seeded amplified Kβ emission signal with that from conventional Kβ emission into the same solid angle, we obtain a signal enhancement of more than 10 5 . Finally, our findings are the first important step of enhancing and controlling the emission of selected final states of the Kβ spectrum with applications in chemical and materials science.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Observation of the p η ' Cusp in the New Precise Beam Asymmetry Σ Data for γ p → p η

Data on the beam asymmetry Σ in the photoproduction of η mesons off protons are reported for tagged photon energies from 1130 to 1790 MeV (mass range from W = 1748 MeV to W = 2045 MeV). The data cover the full solid angle that allows for a precise moment analysis. For the first time, a strong cusp effect in a polarization observable has been observed that is an effect of a branch-point singularity at the pη' threshold [E γ = 1447 MeV (W = 1896 MeV)]. Here, the latest BnGa partial wave analysis includes the new beam asymmetry data and yields a strong indication for the N(1895)1/2 – nucleon resonance, demonstrating the importance of including all singularities for a correct determination of partial waves and resonance parameters.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quest for Cooper Pair Transfer in Heavy-Ion Reactions: The 206 Pb + 118 Sn Case

In this Letter we report on effects of nucleon-nucleon correlations probed in nucleon transfer reactions with heavy ions. We measured with high efficiency and resolution a complete set of observables for neutron transfer channels in the ²⁰⁶Pb + ¹¹⁸Sn system employing a large solid angle magnetic spectrometer, which allowed us to study a wide range of internuclear distances via a detailed excitation function. The coupled channel theory, based on an independent particle transfer mechanism, follows the experimental transfer probabilities for one- and two-neutron pick-up and stripping channels. The experimental two-neutron transfer cross sections indicate that in reactions between pair-vibrational (closed shell) and pair-rotational (open shell) nuclei, correlations manifest via pair-addition and pair-removal modes, which constitute one of the elementary modes of excitations in nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Observations of the Askaryan Effect in Ice

We report on observations of coherent, impulsive radio Cherenkov radiation from electromagnetic showers in solid ice. This is the first observation of the Askaryan effect in ice. As part of the complete validation process for the ANITA experiment, we performed an experiment at the Stanford Linear Accelerator Center in June 2006 using a 7.5 metric ton ice target. We measure for the first time the large-scale angular dependence of the radiation pattern, a major factor in determining the solid-angle acceptance of ultrahigh-energy neutrino detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Laser-driven ion and electron acceleration from near-critical density gas targets: Towards high-repetition rate operation in the 1 PW, sub-100 fs laser interaction regime

Ion acceleration from gaseous targets driven by relativistic-intensity lasers was demonstrated as early as the late 1990s, yet most of the experiments conducted to date have involved picosecond-duration, Nd:glass lasers operating at low repetition rate. Here, we present measurements on the interaction of ultraintense ( ≈ 10 20 W cm − 2 , 1 PW ) , ultrashort ( ≈ 70 fs ) Ti:Sa laser pulses with near-critical ( ≈ 10 20 cm − 3 ) helium gas jets, a debris-free targetry with the potential for future compatibility with high ( ≈ 1 Hz ) repetition rate operation. We provide evidence of α particles being forward accelerated up to ≈ 2.7 − MeV energy with a total flux of ≈ 10 11 sr − 1 as integrated over > 0.1 − MeV energies and detected within a 0.5 − mrad solid angle. We also report on on-axis emission of relativistic electrons with an exponentially decaying spectrum characterized by a ≈ 10 − MeV slope, i.e., five times larger than the standard ponderomotive scaling. The total charge of these electrons with energy above 2 MeV is estimated to be of ≈ 1 nC , corresponding to ≈ 0.1 % of the laser drive energy. In addition, we observe the formation of a plasma channel, extending longitudinally across the gas density maximum and expanding radially with time. These results are well captured by large-scale particle-in-cell simulations, which reveal that the detected fast ions most likely originate from reflection off the rapidly expanding channel walls. The latter process is predicted to yield ion energies in the MeV range, which compare well with the measurements. Finally, direct laser acceleration is shown to be the dominant mechanism behind the observed electron energization. Published by the American Physical Society 2024

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The point-spread function of fiber-coupled area detectors

The point-spread function (PSF) of a fiber-optic taper-coupled CCD area detector was measured over five decades of intensity using a 20 mm X-ray beam and 2000-fold averaging. The ‘tails’ of the PSF clearly revealed that it is neither Gaussian nor Lorentzian, but instead resembles the solid angle subtended by a pixel at a point source of light held a small distance (27 mm) above the pixel plane. This converges to an inverse cube law far from the beam impact point. Further analysis revealed that the tails are dominated by the fiber-optic taper, with negligible contribution from the phosphor, suggesting that the PSF of all fiber-coupled CCD-type detectors is best described as a Moffat function.

47 OTHER INSTRUMENTATION↗

Collimating Montel mirror as part of a multi-crystal analyzer system for resonant inelastic X-ray scattering

Advances in resonant inelastic X-ray scattering (RIXS) have come in lockstep with improvements in energy resolution. Currently, the best energy resolution at the Ir L 3 -edge stands at ~25 meV, which is achieved using a diced Si(844) spherical crystal analyzer. However, spherical analyzers are limited by their intrinsic reflection width. A novel analyzer system using multiple flat crystals provides a promising way to overcome this limitation. For the present design, an energy resolution at or below 10 meV was selected. Recognizing that the angular acceptance of flat crystals is severely limited, a collimating element is essential to achieve the necessary solid-angle acceptance. For this purpose, a laterally graded, parabolic, multilayer Montel mirror was designed for use at the Ir L 3 -absorption edge. It provides an acceptance larger than 10 mrad, collimating the reflected X-ray beam to smaller than 100 µrad, in both vertical and horizontal directions. The performance of this mirror was studied at beamline 27-ID at the Advanced Photon Source. X-rays from a diamond (111) monochromator illuminated a scattering source of diameter 5 µm, generating an incident beam on the mirror with a well determined divergence of 40 mrad. A flat Si(111) crystal after the mirror served as the divergence analyzer. From X-ray measurements, ray-tracing simulations and optical metrology results, it was established that the Montel mirror satisfied the specifications of angular acceptance and collimation quality necessary for a high-resolution RIXS multi-crystal analyzer system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel fabrication technique for high-resolution spherical crystal analyzers using a microporous aluminium base

Modern inelastic X-ray spectrometers employ curved, bent and diced analyzers to capture sufficiently large solid angles of radially emitted scattered radiation emanating from the sample. Fabricating these intricate analyzers, especially when a high energy resolution of a few millielectronvolts is required, is very time-consuming, expensive and often a hit-or-miss affair. A novel fabrication technique is introduced, utilizing a concave-spherical, microporous aluminium base to hold an assembly of a thin glass substrate with a diced crystal wafer bonded to it. Under uniform vacuum forces, the glass substrate is drawn into the aluminium base, achieving the desired bending radius, while dicing of the diffracting crystal layer prevents bending strain from being imposed on the individual crystal pixels. This technique eliminates the need for permanently bonding the crystal assembly to the concave lens, offering the opportunity for correcting figure errors, avoiding long-term degradation of the permanent bond, and making both lens and crystal reusable. Process and material costs are thus substantially decreased. Two analyzers, Si(844) and Ge(337) with intrinsic resolutions of 14.6 meV and 36.5 meV, respectively, were produced in this fashion and characterized in resonant inelastic X-ray scattering (RIXS) measurements. The achieved overall energy resolutions for both analyzers were 29.4 meV for Si(844) and 56.6 meV for Ge(337). Although the RIXS technique is veru sensitive to analyzer imperfections, the analyzers were found to be equal, if not superior, in quality to their traditional, permanently bonded counterparts.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Understanding the formation of multiply twinned structure in decahedral intermetallic nanoparticles

The structure of monometallic decahedral multiply twinned nanoparticles (MTPs) has been extensively studied, whereas less is known about intermetallic MTPs, especially the mechanism of formation of multiply twinned structures, which remains to be understood. Here, by using aberration-corrected scanning transmission electron microscopy, a detailed structural study of AuCu decahedral intermetallic MTPs is presented. Surface segregation has been revealed on the atomic level and the multiply twinned structure was studied systematically. Significantly different from Au and Cu, the intermetallic AuCu MTP adopts a solid-angle deficiency of −13.35°, which represents an overlap instead of a gap (+7.35° gap for Au and Cu). By analysing and summarizing the differences and similarities among AuCu and other existing monometallic/intermetallic MTPs, the formation mechanism has been investigated from both energetic and geometric perspectives. Finally, a general framework for decahedral MTPs has been proposed and unknown MTPs could be predicted on this basis.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A Measurement of the Scintillation Light Yield in CD4 Using a Photosensitive GEM Detector

The absolute photon yield of scintillation light produced by highly ionizing particles in pure CF{sub 4} has been measured using a photosensitive Gas Electron Multiplier (GEM) detector. The detector consists of two standard GEMs and a CsI coated GEM which acts as a photocathode that is sensitive to the 160 nm scintillation light produced in CF{sub 4}. The light yield was determined in terms of the number of scintillation photons emitted into a 4{pi} solid angle produced per MeV of energy deposited in the gas by a 5.5 MeV alpha particle and found to be 314 {+-} 15 photons per MeV. The quantum yield was determined using a fitting method to determine the number of photoelectrons from the measured pulse height distribution, and by an independent method using the measured gain of the GEM detector. The effect of scintillation light in CF{sub 4} on the performance of Cherenkov detectors, such as the PHENIX Hadron Blind Detector (HBD) at RHIC, is also discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Correlations Between Panoramic Imagery and Gamma-Ray Background in an Urban Area

When searching for radiological sources in an urban area, a vehicle-borne detector system will often measure complex, varying backgrounds primarily from natural gamma-ray sources. Much work has been focused on developing spectral algorithms that retain sensitivity and minimize the false-positive rate even in the presence of such spectral and temporal variability. However, information about the environment surrounding the detector system might also provide useful clues about the expected background, which if incorporated into an algorithm, could improve performance. Recent work has focused on extensive measuring and modeling of urban areas with the goal of understanding how these complex backgrounds arise. This work presents an analysis of panoramic video images and gamma-ray background data collected in Oakland, California, by the radiological multisensor analysis platform (RadMAP) vehicle. Features were extracted from the panoramic images by semantically labeling the images and then convolving the labeled regions with the detector response. A linear model was used to relate the image-derived features to gamma-ray spectral features obtained using nonnegative matrix factorization (NMF) under different regularizations. Here we find some gamma-ray background features correlate strongly with image-derived features that measure the response-adjusted solid angle subtended by sky and buildings, and we discuss the implications for the development of future, contextually aware detection algorithms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-time dose computation: GPU-accelerated source modeling and superposition/convolution

Purpose: To accelerate dose calculation to interactive rates using highly parallel graphics processing units (GPUs). Methods: The authors have extended their prior work in GPU-accelerated superposition/convolution with a modern dual-source model and have enhanced performance. The primary source algorithm supports both focused leaf ends and asymmetric rounded leaf ends. The extra-focal algorithm uses a discretized, isotropic area source and models multileaf collimator leaf height effects. The spectral and attenuation effects of static beam modifiers were integrated into each source's spectral function. The authors introduce the concepts of arc superposition and delta superposition. Arc superposition utilizes separate angular sampling for the total energy released per unit mass (TERMA) and superposition computations to increase accuracy and performance. Delta superposition allows single beamlet changes to be computed efficiently. The authors extended their concept of multi-resolution superposition to include kernel tilting. Multi-resolution superposition approximates solid angle ray-tracing, improving performance and scalability with a minor loss in accuracy. Superposition/convolution was implemented using the inverse cumulative-cumulative kernel and exact radiological path ray-tracing. The accuracy analyses were performed using multiple kernel ray samplings, both with and without kernel tilting and multi-resolution superposition. Results: Source model performance was <9 ms (data dependent) for a high resolution (400{sup 2}) field using an NVIDIA (Santa Clara, CA) GeForce GTX 280. Computation of the physically correct multispectral TERMA attenuation was improved by a material centric approach, which increased performance by over 80%. Superposition performance was improved by {approx}24% to 0.058 and 0.94 s for 64{sup 3} and 128{sup 3} water phantoms; a speed-up of 101-144x over the highly optimized Pinnacle{sup 3} (Philips, Madison, WI) implementation. Pinnacle{sup 3} times were 8.3 and 94 s, respectively, on an AMD (Sunnyvale, CA) Opteron 254 (two cores, 2.8 GHz). Conclusions: The authors have completed a comprehensive, GPU-accelerated dose engine in order to provide a substantial performance gain over CPU based implementations. Real-time dose computation is feasible with the accuracy levels of the superposition/convolution algorithm.

60 APPLIED LIFE SCIENCES↗