Search NASA⌕ Search

SEARCH · Search NASA

Results for “Solid state detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Exploring the Nucleon Structure via Deep Electroproduction Processes

Understanding the internal structure of the nucleon is a fundamental goal of modern physics, which aims at a comprehensive framework describing the internal dynamics of quarks and gluons. Among other structure functions, Generalized Parton Distributions (GPDs) offer a powerful framework for describing the nucleon dynamics by correlating the longitudinal momentum and the transverse position of its internal partons. Such a correlation provides a three-dimensional picture of the nucleon and enables access to fundamental properties, including the internal pressure distributions and the parton’s angular momentum contribution to the nucleon's total spin, thereby playing a central role in resolving the nucleon spin puzzle. At the Thomas Jefferson National Facility (JLab), polarized electron beam experiments allow for probing GPDs through the measurement of hard exclusive processes. Among the cleanest experimental channels, we find the electro-production of a real photon through the Deeply Virtual Compton Scattering (DVCS) mechanism. The first data-taking period of the CLAS12 program, taking place in 2018, allowed for unique DVCS Beam Spin Asymmetry (BSA) measurements in the phase space covered by a 10.6 GeV polarized electron beam impinging on an unpolarized liquid hydrogen target. Although detecting all final-state particles ensures exclusivity of the process, conservation laws indicate that it is not mandatory. I adopt an approach omitting the direct detection of the recoil proton, providing a simplified yet effective event selection strategy that boosts statistics and gives access to a larger phase space sensitive to the underlying GPD dynamics through BSA and cross section measurements. The Double DVCS (DDVCS) process promises a dedicated mapping of GPDs. Contributing to the electro-production of a lepton pair cross-section, the DDVCS reaction extends DVCS by allowing the final-state photon to be virtual, enriching the kinematic phase space and providing unique access to the internal correlations encoded by GPDs. A feasibility study is conducted to assess the potential of future DDVCS measurements at Jefferson Lab and the future Electron-Ion Collider (EIC). While Jefferson Lab will provide DDVCS measurements in the valence region through the SoLID$\mu$ and $\mu$CLAS12 experimental projects, in the long term, the EIC will provide complementary measurements in the sea region, both accessing unprecedented information about GPDs in a phase space region otherwise inaccessible. Taken together, these investigations demonstrate both the current capabilities and future opportunities for probing GPDs through exclusive processes. The experimental analysis of DVCS at CLAS12 provides precise measurements within an established framework, while the phenomenological study of DDVCS opens the door to richer and more comprehensive explorations with future detectors and facilities.

Alvarado, Juan [Université Paris-Saclay: Gif-sur-Y↗

New NDA Methods for Thorium Fuel Cycle Safeguards (Final Report)

This project developed portable Neutron Resonance Transmission Analysis (pNRTA) as a new non-destructive assay (NDA) method for thorium fuel cycles safeguards and other applications where multiple isotopes must be measured when present together. pNRTA leverages epithermal neutron resonances to assay multiple safeguards-relevant isotopes (e.g., 233 U and 235 U) when they are present together in a sample. Existing techniques are challenged by this task, driving the need for new active interrogation methods. With selected detectors, pNRTA works in high gamma-ray backgrounds from fission and activation products and 232 U progeny expected in thorium fuel cycle samples. This project leveraged a pNRTA system developed at Pacific Northwest National Laboratory (PNNL) and collaboration with the Massachusetts Institute of Technology (MIT). The system uses a commercially available deuterium-tritium (DT) neutron generator at short standoff (2 m). Key achievements in this project included: first-of-a-kind pNRTA quantitative measurements of 233 U oxide samples, an assessment of neutron detector technologies suitable for pNRTA in high gamma-ray background environments, experimentally demonstrating quantitative assay of samples containing 233 U and 235 U, and modeling studies showing the applicability of pNRTA to a wide range of material forms. Further, a custom algorithm was developed at MIT, which provided mean bias of 9% and relative standard deviation of 36% in assaying 233 U, 235 U, 238 U, and 232 Th content in eight measured samples. These outcomes form a solid technical basis for pNRTA as a new promising capability for international safeguards verification that is portable, non-destructive, quantitative, and isotopic specific.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Scatter and Blur Corrections for High-Energy X-Ray Radiography

High-energy X-ray radiography is useful as a highly penetrating method for imaging through dense materials. However, the primary modes of interaction of X-rays at these energies involve scattering or the production of secondary high-energy photons, which can interfere with the image. In addition, detector blurring, often resulting from scatter within the detector, can reduce image sharpness. Both of these processes can be mitigated with the use of convolution kernels, with the main challenge being that the proper kernel to use is not known, particularly for the scatter contribution. By radiographing solid slabs of uniform attenuation, we show that point spread functions and material-specific point scatter functions can be determined to significantly reduce the effect of detector blurring and object scatter. Constraining the fits to the slabs and uniform transmission within the slabs is sufficient to recover these functions. A functional form that reproduces the angular distribution of high-energy bremsstrahlung X-rays is presented for recovering point scatter functions. In conclusion, the method is applied to radiographs of objects from bremsstrahlung X-ray sources operating at 4- and 7.5-MV endpoint energies and a significant increase in sharpness is observed.

Blind deconvolution↗

Kryptonate Hydrogen Detection System (Final Report)

A prototype model of a multipurpose instrument which demonstrates the applicability of the Kryptonate® technique for detecting hydrogen gas was developed. This report describes the construction of the instrument and presents a laboratory evaluation of its performance. Performance was excellent. The instrument was designed to detect hydrogen in air at concentrations of 0-3% by volume, and to detect hydrogen in nitrogen or other inert gas at concentrations of 0-10% by volume. Other detection levels (both higher and lower) could be set if required. Ultimate response times can be made of the order of 0.5 seconds. The instrument is an all solid state device operating from 120V 60 Hz power source. The instrument has been designed to enable modifications to be made with a minimum amount of difficulty.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optically induced quantum transitions in direct probed mesoscopic NbSe 2 for prototypical bolometers

Superconducting transition-edge sensors (TES) have emerged as fascinating devices to detect broadband electromagnetic radiation with low thermal noise. The advent of metallic transition metal dichalcogenides, such as NbSe 2 , has also created an impetus to understand their low-temperature properties, including superconductivity. Interestingly, NbSe 2 -based sensor within the TES framework remains unexplored. In this work, direct-probed superconducting NbSe 2 absorbers led to a proof-of-concept demonstration for the transduction of incoming light to heat, where a thermodynamic superconducting phase transition in NbSe 2 was evident to switch it to the normal-state, when biased below its superconducting transition temperature. A wavelength-dependent response of its optical absorption properties was observed, based on the incident optical excitation source used. Furthermore, extensive optical characterization studies were conducted using Raman spectroscopy, where the in-plane and out-of-plane thermal conductivity was empirically determined. Our results open new possibilities for the use of NbSe 2 in superconducting radiation detectors, including in a TES framework

47 OTHER INSTRUMENTATION↗

Search for very-short-baseline oscillations of reactor antineutrinos with the SoLid detector

In this paper we report the first scientific result based on antineutrinos emitted from the BR2 reactor at SCK CEN. The SoLid experiment uses a novel type of highly granular detector whose basic detection unit combines two scintillators, polyvinyl toluene (PVT) and Li 6 F : ZnS ( Ag ) , to measure antineutrinos via their inverse- β -decay products. An advantage of PVT is its highly linear response as a function of deposited particle energy. The full-scale detector comprises 12 800 voxels and operates over a very short 6.3–8.9 m baseline from the reactor core. The detector segmentation and its three-dimensional imaging capabilities facilitate the extraction of the positron energy from the rest of the visible energy, allowing the latter to be utilized for signal-background discrimination. We present a result obtained from 280 reactor-on days (55 MW mean power) and 172 reactor-off days, respectively, of live data taking. A total of 29 479 ± 603 (stat) antineutrino candidates have been selected, corresponding to an average rate of 105 events per day and a signal-to-background ratio of 0.27. A search for disappearance of antineutrinos to a sterile state has been conducted using complementary model-dependent frequentist and Bayesian fits, providing constraints on the allowed region of the reactor antineutrino anomaly.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design and performance of a magnetic bottle electron spectrometer for high-energy photoelectron spectroscopy

We describe the design and performance of a magnetic bottle electron spectrometer (MBES) for high-energy electron spectroscopy. Our design features a 2 m long electron drift tube and electrostatic retardation lens, achieving sub-electronvolt (eV) electron kinetic energy resolution for high energy (several hundred eV) electrons with a close to 4π collection solid angle. A segmented anode electron detector enables the simultaneous collection of photoelectron spectra in high resolution and high collection efficiency modes. This versatile instrument is installed at the time-resolved molecular and optical sciences instrument at the Linac Coherent Light Source x-ray free-electron laser (XFEL). In this paper, we demonstrate its high resolution, collection efficiency, and spatial selectivity in measurements where it is coupled to an XFEL source. These combined characteristics are designed to enable high-resolution time-resolved measurements using x-ray photoelectron, absorption, and Auger–Meitner spectroscopy. We also describe the pervasive artifact in MBES time-of-flight spectra that arises from a periodic modulation in electron collection efficiency and present a robust analysis procedure for its removal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Operation and performance of a dual-phase crystalline/vapor xenon time projection chamber

We have built and operated a crystalline/vapor xenon TPC, with the goal of improving searches for dark matter. The motivation for this instrument is the fact that beta decays from the radon decay chain to the ground state presently limit the state-of-the-art liquid/vapor xenon experiments. In contrast, a crystalline xenon target has the potential to exclude, or tag and reject radon-chain backgrounds. As a preamble to demonstrating such capabilities, the present article makes a first demonstration of the operation of a crystalline/vapor xenon TPC with electroluminescence (gas gain) for the electron signal readout. It also shows that the scintillation yield in crystalline xenon appears to be identical to that in liquid xenon, in contrast to previous results.

47 OTHER INSTRUMENTATION↗

Cyclic superconducting refrigerators using guided fluxon propagation

We propose cyclic refrigeration in solid state, employing a gas of magnetic field vortices in a type-II superconductor—also known as fluxons—as the cooling agent. Refrigeration cycles are realized by envisioning a racetrack geometry consisting of both adiabatic and isothermal arms, etched into a type-II superconductor. The guided propagation of fluxons in the racetrack is achieved by applying an external electrical current, in a Corbino geometry, through the sample. A gradient of magnetic field is set across the racetrack allowing one to adiabatically cool down and heat up the fluxons, which subsequently exchange heat with the cold and hot reservoirs, respectively. We characterize the steady state of refrigeration cycles thermodynamically for both s -wave and d -wave pairing symmetries, and present their figures of merit such as the cooling power delivered, and the coefficient of performance. Our cooling principle can offer significant cooling for on-chip microrefrigeration purposes, by locally cooling below the base temperatures achievable in a conventional dilution refrigerator. We estimate n W / m m 2 of cooling power per unit area assuming a tunnel coupling with ∼ M Ω µ m 2 specific resistance. Integrating the fluxon fridge to quantum circuits can enhance their coherence time by locally suppressing thermal fluctuations, and improve the efficiency of single photon detectors and charge sensors. Published by the American Physical Society 2024

Karmakar, Tathagata (ORCID:0000000187812017)↗

Horizontal 1 K refrigerator with novel loading mechanism for polarized solid targets

We describe a helium evaporation refrigerator used to cool dynamically polarized proton and deuteron targets for electron-scattering experiments using the CEBAF Large Acceptance Spectrometer CLAS12 at Jefferson Lab. The geometry of the CLAS12 detector systems places severe design and construction constraints on the refrigerator and its ancillary equipment, resulting in a horizontal cryostat with a length of 4 m. The 16 cm 3 target samples, consisting of frozen ammonia (NH 3 or ND 3 ), are loaded at the upstream end of the cryostat and moved to the beam-interaction region using a novel transport mechanism. At this location they are cooled with superfluid helium and polarized via dynamic nuclear polarization at 1 K and 5 T. In this manner samples can be replaced and cooled to 1 K in about 30 minutes without disturbing any elements of the electron beam line or particle detection system. In conclusion, we estimate that this method saved 18 days of valuable beam time over the course of a recent, 88-day long experiment.

Evaporation refrigerator↗

Fluorescence time profile measurement of LAB based liquid scintillator in response to medium relativistic ion particles

Liquid scintillator is widely used in particle physics experiments due to its high light yield, good timing resolution, scalability and low cost. Certain liquid scintillators exhibit pulse shape discrimination capabilities because of difference in fluorescence timing properties induced by different particles. Its fluoresence timing properties have been measured mostly for radioactive decay sources at MeV energies. Here, we present a novel measurement of fluorescence time properties of Linear Alkyl Benzene (LAB) based liquid scintillator in response to high-energy ions of hydrogen (Z = 1), helium (Z = 2) and krypton at around 200–300 MeV/u for the first time. We compared the results to those from radioactive sources and observed a distinct dE / dX dependence, regardless of the particle type. These findings are essential for physics searches such as the diffuse supernova neutrino background in large liquid scintillator detectors like JUNO, and are also critical towards understanding the underlying scintillation timing mechanism.

Ion identification systems↗

Multi-phase characterization of pitch-carbon coated nano-silicon anodes for lithium-ion batteries

Silicon (Si) is a leading next-generation Li-ion battery anode candidate that meets rigorous performance demands for portable power including enhanced power and energy density with robust cycling performance. However, a series of complex and interrelated reactions lead to reduced calendar life in Si-containing systems and therefore challenge practical adoption. In the present work, we probe the mechanisms underlying observed performance improvements by adding a pitch-carbon coating onto nano-Si material. We pair solid-phase (X-ray photoemission spectroscopy, Fourier-transform infrared), semi-volatile phase (solid-phase microextraction-gas chromatography-mass spectrometry), and gas-phase (gas chromatography-flame-ionization detector) characterization signals to comprehensively evaluate the impact of pitch-carbon coating on the evolution of the Si solid-electrolyte interphase (SEI) and the associated impacts on electrode/electrolyte reactivity. The pitch-carbon is found to serve as a physicochemical barrier, reducing the electro-active surface area for Si/electrolyte reactivity and preventing Si oxidation. Further, the pitch-carbon coating promotes the evolution of a more-favorable SEI by subsuming substantial functionality typically associated with the fluoroethylene carbonate (FEC) electrolyte additive - such as alkoxide scavenging and suppression of transesterification pathways - and by shifting the competitive electrolyte degradation pathways' favorability. The multi-phase characterization approach enables holistic end-products evaluation from complex (electro)chemical interfacial reactions, which informs a robust interpretation of the carbon coating's role in electrochemical performance improvements. The present mechanistic evaluation aids the rational design for improved nano-Si materials.

25 ENERGY STORAGE↗

Portable Distortion Free Large Solid Angle Coverage Detector

Neutron single crystal diffractometers require large solid angle coverage for optimum performance. This can be achieved by tiling flat detectors in a cylindrical or spherical geometry, but results in large gaps in detector coverage and parallax distortion. The detector edges exhibit degraded resolution, distortion, and gamma rejection. Since the detector edge regions are a significant fraction of the detector active area, they must be removed from the experimental data set, requiring extra beam time to collect enough analysis data. A spherical detector with a continuous surface would effectively address this issue while eliminating most boundary ‘dead’ areas. Here we report on the development of a novel hemispherical shaped neutron detector using seamlessly tiled readout modules to form the desired shape. The heart of the detector is a specially developed curved neutron scintillator coupled to high resolution silicon photomultiplier (SiPM) Anger cameras via custom made fiber optic tapers (FOTs). The detector has been assembled and initial tests have been conducted at the High Flux Isotope Reactor (HFIR) beamlines at Oak Ridge National Laboratory (ORNL). Here, in this work, we describe details of the scintillator design, fabrication and characterization, evaluation of individual detector modules, the details of the detector design implementation, and evaluation of the assembled detector at ORNL beamlines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-resolution inelastic x-ray scattering at the high energy density scientific instrument at the European X-Ray Free-Electron Laser

We introduce a setup to measure high-resolution inelastic x-ray scattering at the High Energy Density scientific instrument at the European X-Ray Free-Electron Laser (XFEL). The setup uses the Si (533) reflection in a channel-cut monochromator and three spherical diced analyzer crystals in near-backscattering geometry to reach a high spectral resolution. An energy resolution of 44 meV is demonstrated for the experimental setup, close to the theoretically achievable minimum resolution. The analyzer crystals and detector are mounted on a curved-rail system, allowing quick and reliable changes in scattering angle without breaking vacuum. The entire setup is designed for operation at 10 Hz, the same repetition rate as the high-power lasers available at the instrument and the fundamental repetition rate of the European XFEL. Among other measurements, it is envisioned that this setup will allow studies of the dynamics of highly transient laser generated states of matter.

47 OTHER INSTRUMENTATION↗

Time-Domain Extreme-Ultraviolet Diffuse Scattering Spectroscopy of Nanoscale Surface Phonons

Here, we report the observation of dynamic fringe patterns in the diffuse scattering of extreme ultraviolet light from surfaces, following femtosecond optical excitation. At each point on the detector, the diffuse scattering intensity exhibits oscillations at well-defined frequencies that correspond to surface phonons with wave vectors determined by the scattering geometry, indicating that the optical excitation generates coherent surface phonons propagating in all directions and spanning a wavelength range from 60 to 300 nm. This phenomenon is observed on a variety of samples, including single-layer and multilayer metal films, as well as bulk semiconductors. The measured surface phonon dispersions show good agreement with theoretical calculations. By comparing signal amplitudes from samples with different surface morphologies, we find that the excitation mechanism is linked to the natural surface roughness of the samples. However, the signal is still detectable on extremely smooth surfaces with subnanometer roughness. Our findings demonstrate a simple and effective method for optically exciting coherent surface phonons with nanoscale wavelengths on a wide range of solid samples and establish a foundation for surface phonon spectroscopy in a wave vector range well beyond the limit of conventional surface Brillouin scattering.

Capotondi, F. [Elettra-Sincrotrone Trieste (Italy)↗

Chemical Interaction of Palladium in Uranium Oxycarbide Nuclear Fuel Kernel

Chemical Interaction of Palladium in Uranium Oxycarbide Nuclear Fuel Kernel Jana Howard1,3, Guang Yang3, Haiyan Zhao1*, Patrick Warren4, Tiankai Yao3, Steven Cavazos4 Elizabeth Sooby Wood4*, Ching-heng Shiau2 1 University of Idaho, Environmental Science, Idaho Falls, Idaho, USA 2 Boise State University, Microscopy and Characterization Suite, Idaho Falls, Idaho, USA 3 Idaho National Laboratory, Idaho Falls, Idaho, USA 4 University of Texas San Antonio, Department of Physics and Astronomy, San Antonio, Texas, USA *Corresponding author: haiyanz@uidaho.edu; elizabeth.soobywood@utsa.edu Tri-structural Isotropic (TRISO) particle fuel is the preferred choice for the newest and next-generation high-temperature nuclear reactors due to its robust construction [1]. The fuel design effectively contains fission products inside the particle at extremely high temperatures [2]. However, the effect of transition metal fission products on fuel performance and structural integrity remains largely unknown, creating uncertainties in predicting fuel performance and potential failure mechanisms [2]. For example, palladium (Pd) has a strong tendency to form intermetallic phases with uranium (U). These new phases tend to be hard and brittle which could lead to fracture of fuel kernel during irradiation [3,4]. Pd is not normally produced in high concentrations in normal fission reactions however, driving the production of Pd into the locality of a Uranium Oxycarbide (UCO) nuclear fuel provides an opportunity to closely observe the diffusion and chemical interactions. This study focuses on detailed transmission electron microscopy characterization of the intermetallic phases formed by the interaction between a UCO kernel and a Pd bar after annealing at 1100 °C for 100 hours. Figure 1 provides an overview of the UCO kernel in contact with the Pd bar. The UCO-Pd sample surface was examined using a Focused Ion Beam (FIB) Quanta 3D FEG FEI in VCD detector mode at 10kV, 83pA to reveal surface features. Several key surface features in the interaction region were observed including: (1) a small area with dendritic microstructure, (2) color contrast near the UCO kernel and Pd boundary, and (3) darker and lighter regions throughout the sample surface. To analyze diffusion behavior, FIB was used to prepare lamellae from five different areas of the UCO-Pd sample, as well as one for the as-received sample. These lamellae were examined using a Scanning Transmission Electron Microscope ThermoFisher Spectra 300 (STEM-Spectra). Energy Dispersive Spectroscopy results confirmed the diffusion between the UCO fuel and Pd bar. Figure 2 shows the identified phases of UC, UO2, and Pd dispersed throughout the interaction region. It was also found that the Pd concentration decreases as the radial distance from the UCO-Pd interface increases. The Pd concentration was 36.93% atomic fraction 11µm from the interaction region then decreased to 7.51% atomic fraction at 257 µm away from the interaction region. Figure 3 shows how concentrations of U and Pd vary across the interaction zone, highlighting the extent of diffusion. This study confirms that Pd interacts with surrounding material to form U-Pd phase and diffusion zones. These diffusion zones vary in composition depending on its radial distance from the point of contact with the Pd bar. These findings contribute to a deeper understanding of the fission product behavior in high temperature nuclear fuels, aiding in the prediction and mitigation of potential fuel degradation mechanisms. A B C Fig. 1. SEM micrographs of UCO fuel kernel in contact with solid Pd bar and the lift out locations. Figure 1A shows UCO fuel kernel in contact with solid Pd bar. Figure 1B shows a higher magnification image of the UCO fuel-Pd interaction zone. Figure 1C shows lift out sites for the lamellae. A B C Fig 2. EDS maps reveal the distribution of U, O, and Pd in location 3. Figure 2A shows the distribution of uranium. Figure 2B shows the distribution of oxygen. Figure 2C shows the distribution of palladium. A B C Fig 3. Palladium and uranium concentration across interaction zone in location 2. Figure 3A shows EDS map of lift out number 2. Figure 3B shows a zoomed in EDS map taken from the interaction zone. Figure 3C shows a line graph of uranium and palladium concentrations across the interaction zone. References: 1. B.E. Wells, N.R. Phillips, K.J. Geelhood. Pacific West Laboratory. (2021). TRISO Fuel: Properties and Failure Modes. https://www.nrc.gov/docs/ML2117/ML21175A152.pdf (Accessed January 16, 2025). 2. American Nuclear Society. TRISO Fuel Development Progresses in INL, ORNL. https://www.gen-4.org/gif/upload/docs/application/pdf/2014-03/nov13nn_fuel_reprint.pdf (Accessed January 16, 2025) 3. Clark R.A., M.A. Con

36 - MATERIALS SCIENCE↗

Chemical Interaction of Palladium in Uranium Oxycarbide Nuclear Fuel Kernel

Chemical Interaction of Palladium in Uranium Oxycarbide Nuclear Fuel Kernel Jana Howard1,3, Guang Yang3, Haiyan Zhao1*, Patrick Warren4, Tiankai Yao3, Steven Cavazos4 Elizabeth Sooby Wood4*, Ching-heng Shiau2 1 University of Idaho, Environmental Science, Idaho Falls, Idaho, USA 2 Boise State University, Microscopy and Characterization Suite, Idaho Falls, Idaho, USA 3 Idaho National Laboratory, Idaho Falls, Idaho, USA 4 University of Texas San Antonio, Department of Physics and Astronomy, San Antonio, Texas, USA *Corresponding author: haiyanz@uidaho.edu; elizabeth.soobywood@utsa.edu Tri-structural Isotropic (TRISO) particle fuel is the preferred choice for the newest and next-generation high-temperature nuclear reactors due to its robust construction [1]. The fuel design effectively contains fission products inside the particle at extremely high temperatures [2]. However, the effect of transition metal fission products on fuel performance and structural integrity remains largely unknown, creating uncertainties in predicting fuel performance and potential failure mechanisms [2]. For example, palladium (Pd) has a strong tendency to form intermetallic phases with uranium (U). These new phases tend to be hard and brittle which could lead to fracture of fuel kernel during irradiation [3,4]. Pd is not normally produced in high concentrations in normal fission reactions however, driving the production of Pd into the locality of a Uranium Oxycarbide (UCO) nuclear fuel provides an opportunity to closely observe the diffusion and chemical interactions. This study focuses on detailed transmission electron microscopy characterization of the intermetallic phases formed by the interaction between a UCO kernel and a Pd bar after annealing at 1100 °C for 100 hours. Figure 1 provides an overview of the UCO kernel in contact with the Pd bar. The UCO-Pd sample surface was examined using a Focused Ion Beam (FIB) Quanta 3D FEG FEI in VCD detector mode at 10kV, 83pA to reveal surface features. Several key surface features in the interaction region were observed including: (1) a small area with dendritic microstructure, (2) color contrast near the UCO kernel and Pd boundary, and (3) darker and lighter regions throughout the sample surface. To analyze diffusion behavior, FIB was used to prepare lamellae from five different areas of the UCO-Pd sample, as well as one for the as-received sample. These lamellae were examined using a Scanning Transmission Electron Microscope ThermoFisher Spectra 300 (STEM-Spectra). Energy Dispersive Spectroscopy results confirmed the diffusion between the UCO fuel and Pd bar. Figure 2 shows the identified phases of UC, UO2, and Pd dispersed throughout the interaction region. It was also found that the Pd concentration decreases as the radial distance from the UCO-Pd interface increases. The Pd concentration was 36.93% atomic fraction 11µm from the interaction region then decreased to 7.51% atomic fraction at 257 µm away from the interaction region. Figure 3 shows how concentrations of U and Pd vary across the interaction zone, highlighting the extent of diffusion. This study confirms that Pd interacts with surrounding material to form U-Pd phase and diffusion zones. These diffusion zones vary in composition depending on its radial distance from the point of contact with the Pd bar. These findings contribute to a deeper understanding of the fission product behavior in high temperature nuclear fuels, aiding in the prediction and mitigation of potential fuel degradation mechanisms. A B C Fig. 1. SEM micrographs of UCO fuel kernel in contact with solid Pd bar and the lift out locations. Figure 1A shows UCO fuel kernel in contact with solid Pd bar. Figure 1B shows a higher magnification image of the UCO fuel-Pd interaction zone. Figure 1C shows lift out sites for the lamellae. A B C Fig 2. EDS maps reveal the distribution of U, O, and Pd in location 3. Figure 2A shows the distribution of uranium. Figure 2B shows the distribution of oxygen. Figure 2C shows the distribution of palladium. A B C Fig 3. Palladium and uranium concentration across interaction zone in location 2. Figure 3A shows EDS map of lift out number 2. Figure 3B shows a zoomed in EDS map taken from the interaction zone. Figure 3C shows a line graph of uranium and palladium concentrations across the interaction zone. References: 1. B.E. Wells, N.R. Phillips, K.J. Geelhood. Pacific West Laboratory. (2021). TRISO Fuel: Properties and Failure Modes. https://www.nrc.gov/docs/ML2117/ML21175A152.pdf (Accessed January 16, 2025). 2. American Nuclear Society. TRISO Fuel Development Progresses in INL, ORNL. https://www.gen-4.org/gif/upload/docs/application/pdf/2014-03/nov13nn_fuel_reprint.pdf (Accessed January 16, 2025) 3. Clark R.A., M.A. Con

36 - MATERIALS SCIENCE↗

Operation of a Modular 3D-Pixelated Liquid Argon Time-Projection Chamber in a Neutrino Beam

The 2x2 Demonstrator, a prototype for the Deep Underground Neutrino Experiment (DUNE) liquid argon (LAr) Near Detector, was exposed to the Neutrinos from the Main Injector (NuMI) neutrino beam at Fermi National Accelerator Laboratory (Fermilab). This detector is a prototype of a new modular design for a liquid argon time-projection chamber (LArTPC), comprising a two-by-two array of four modules, each further segmented into two optically isolated LArTPCs. The 2x2 Demonstrator features a number of pioneering technologies, including a low-profile resistive field shell to establish drift fields, native 3D ionization pixelated imaging, and a high-coverage dielectric light readout system. The 2.4-tonne active mass detector is flanked upstream and downstream by supplemental solid-scintillator tracking planes, repurposed from the MINERvA experiment, which track ionizing particles exiting the argon volume. The antineutrino beam data collected by the detector over a 4.5 day period in 2024 include over 30,000 neutrino interactions in the LAr active volume—the first neutrino interactions reported by a DUNE detector prototype. During its physics-quality run, the 2x2 Demonstrator operated at a nominal drift field of 500 V/cm and maintained good LAr purity, with a stable electron lifetime of approximately 1.25 ms. This paper describes the detector and supporting systems, summarizes the installation and commissioning, and presents the initial validation of collected NuMI beam and off-beam self-triggers. In addition, it highlights observed interactions in the detector volume, including candidate muon antineutrino events.

47 OTHER INSTRUMENTATION↗