Search NASA⌕ Search

SEARCH · Search NASA

Results for “Surface Operations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

AmeriFlux FLUXNET-1F US-Ne1 Mead - irrigated continuous maize site

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-Ne1 Mead - irrigated continuous maize site. This is the FLUXNET version of the carbon flux data for the site US-Ne1 Mead - irrigated continuous maize site produced by applying the standard ONEFlux (1F) software. Site Description - The study site is one of three fields (all located within 1.6 km of each other) at the University of Nebraska Eastern Nebraska Research, Education and Extension Center near Mead, Nebraska. This site is irrigated with a center pivot system. Prior to the initiation of the study, the irrigated site had a 10-yr history of maize-soybean rotation under no-till. A tillage operation (disking) was done just prior to the 2001 planting to homogenize the top 0.1 m of soil, incorporate P and K fertilizers, as well as previously accumulated surface residues. This field was planted with maize every growing season. Since the 2001 tillage operation, the site has been under no-till management until the harvest of 2005. Following harvest, a conservation-plow tillage operation was initiated where a small amount of N fertilizer is sprayed on the residue immediately prior to the plow operation. Approximately 1/3 of the crop residue is left on the surface. The post-harvest conservation-plow operation continued until 2022. Since 2022, the site management has changed such that the field is now a strictly no-till, maize-soybean rotation (maize odd years and soybean even years).

Suyker, Andy↗

Formation of field-induced breakdown precursors on metallic electrode surfaces

Understanding the underlying factors responsible for higher-than-anticipated local field enhancements required to trigger vacuum breakdown on pristine metal surfaces is crucial for the development of devices capable of withstanding intense operational fields. In this study, we investigate the behavior of nominally flat copper electrode surfaces exposed to electric fields of hundreds of MV/m. Our novel approach considers curvature-driven diffusion processes to elucidate the formation of sharp breakdown precursors. To do so, we develop a mesoscale finite element model that accounts for driving forces arising from both electrostatic and surface-tension-induced contributions to the free energy. Our findings reveal a dual influence: surface tension tends to mitigate local curvature, while the electric field drives mass transport toward regions of high local field density. This phenomenon can trigger the growth of sharper protrusions, ultimately leading to a rapid enhancement of local fields and, consequently, to a runaway growth instability. We delineate supercritical and subcritical regimes across a range of initial surface roughness. Our numerical results are in qualitative agreement with experimentally reported data, indicating the potential practical relevance of field-driven diffusion in the formation of breakdown precursors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterizing the plasma-induced thermal loads on a 200 kW light-ion helicon plasma source via infra-red thermography

The light-ion helicon plasma source of the Proto-MPEX linear plasma device has been recently upgraded to enable pulsed (0.5–1 s) operation up to 200 kW. The main objective of this work is to report on the plasma-induced surface heat fluxes incident on the helicon window during high power operation (60–150 kW net power) for the purpose of the design of the upcoming material plasma exposure eXperiment (MPEX). The IR imaging system and associated physics models for the extraction of surface heat fluxes are presented. Furthermore, experimental results demonstrate that the control of the plasma strike point via magnetic flux mapping and the use of dedicated limiters is effective at reducing the heat loads on the dielectric window. Moreover, it is found that the flux mapping must create a gap between the plasma and the dielectric window of at least the plasma radial decay length. Extrapolated to 200 kW net RF power, this mode of operation can reduce the power lost to the dielectric window by 33%. The results presented have direct application to the design of high-powered helicon plasma sources that operate in a steady state. Examples include linear divertor simulators such as MPEX, electric thrusters, negative ion sources for NBI and linear plasma–material interaction test stands.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi-axis oscillating flight simulator

An apparatus for simulating an oscillating flight path is provided. The apparatus comprises a slide extending along a first axis; a support structure slidably coupled to the slide; and a table connected to the support structure. The support structure is operable to move along the slide. The table is coupled to the support structure and operable to rotate about a second axis orthogonal to the first axis. The table comprises a surface that is parallel to the second axis and that is operable to rotate about a third axis orthogonal to the second axis.

Dark, Philip Ryan↗

Update to the Performance Assessment for the Savannah River Site Saltstone Disposal Facility - 20124

In 2019, Savannah River Remediation developed a revision to the performance assessment (PA) on behalf of the U.S. Department of Energy (DOE) Savannah River Operations Office (SR) for the near-surface disposal of low-level waste at the Savannah River Site (SRS) Saltstone Disposal Facility (SDF). Soluble waste from SRS Tank Farms undergoes salt processing to remove cesium and other high activity constituents. The low-activity decontaminated salt solution (DSS) is then immobilized by mixing it into a cementitious waste form known as saltstone. After mixing, the saltstone is poured into leak-tight concrete vaults, known as saltstone disposal units (SDUs), where the waste form cures. By the time of facility closure, the SDF is expected to consist of 15 SDUs with a combined capacity of 1.06 E+09 L (280 Mgal) of cured saltstone. The facility operates under a Disposal Authorization Statement (DAS) from DOE and a permit from the South Carolina Department of Health and Environmental Control (SCDHEC). Since the start of operations in 1990, the SDF has received almost 6.7 E+07 L (18 Mgal) of DSS, resulting in the safe disposal of 2.7 E+16 Bq (7.3 E+05 Ci) of activity. Due to the radioactive decay of short-lived contaminants, the total remaining activity in the disposed waste is estimated to be approximately 1.4 E+16 Bq (3.9 E+05 Ci), as of September 2018. The Disposal Authorization Statement requires a demonstration that the system of engineered and natural features of the disposal facility will limit releases from the facility and be protective of human health and the environment for at least the next 1,000 years. The long-term performance of the facility was evaluated under the requirements of the DoE's Radioactive Waste Management Manual (US DOE Manual 435.1-1). Simulations were performed to demonstrate that the disposal facility would meet performance objectives specified in the manual. The evaluation was based on numerical models that simulate the releases of contaminants from the saltstone waste form. Contaminants were transported through groundwater and air pathways to points of assessment to evaluate compliance. In addition, the potential consequences of an inadvertent human intrusion (IHI) were also evaluated. In accordance with the guidance and recommendations in US DoE's technical standard for DAS, deterministic and probabilistic analyses were performed to demonstrate the SDF system, which includes the engineered cover system, the SDUs, the waste form, and the natural features of the site, provides a reasonable expectation that saltstone disposal will meet performance objectives. Post-closure doses to future members of the public (MOP) were evaluated; dose estimates from the air pathway were well below the 1.0 E-04 Sv/yr (10 mrem/yr) performance objective within 1,000 years, and the calculated doses to the MOP from all exposure pathways, including the groundwater and air pathways, were well below the 2.5 E-04 Sv/yr (25 mrem/yr) performance objective within 1,000 years. Doses following an assumed intrusion event within the facility boundaries were well below the IHI performance objectives, where the acute IHI dose was below the acute IHI dose performance objective of 5.0 E-03 Sv (500 mrem) and the chronic IHI dose was below the chronic IHI dose performance objective of 1.0 E-03 Sv/yr (100 mrem/yr) within 1,000 years. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Issue Resolution During the Development of the Performance Assessment for the Savannah River Site Saltstone Disposal Facility - 20125

In 2019, Savannah River Remediation developed a revision to the performance assessment (PA) on behalf of the U.S. Department of Energy (DOE) Savannah River Operations Office (SR) for the near-surface disposal of low-level waste at the Savannah River Site (SRS) Saltstone Disposal Facility (SDF). Soluble waste from SRS Tank Farms undergoes salt processing to remove cesium and other high-activity constituents. The low-activity decontaminated salt solution (DSS) is then immobilized by mixing it into a cementitious waste form known as saltstone. After mixing, the saltstone is poured into leak-tight concrete vaults, known as saltstone disposal units (SDUs), where the waste form cures. By the time of facility closure, the SDF is expected to consist of 15 SDUs with a combined capacity of 1.06 E+09 L (280 Mgal) of cured saltstone. The facility operates under a Disposal Authorization Statement from DOE and a permit from the South Carolina Department of Health and Environmental Control (SCDHEC). Since the start of operations in 1990, the SDF has received almost 6.7 E+07 L (18 Mgal) of DSS, resulting in the safe disposal of 2.7 E+16 Bq (7.3 E+05 Ci) of activity. Due to the radioactive decay of short-lived contaminants, the total remaining activity in the disposed waste is estimated to be approximately 1.4 E+16 Bq (3.9 E+05 Ci), as of September 2018. The Disposal Authorization Statement requires a demonstration that the system of engineered and natural features of the disposal facility will limit releases from the facility and be protective of human health and the environment for at least the next 1,000 years. The long-term performance of the facility was evaluated under the requirements of the DoE's Radioactive Waste Management Manual (US DOE Manual 435.1-1). Simulations were performed to demonstrate that the disposal facility would meet performance objectives specified in the manual. The evaluation was based on numerical models that simulate the releases of contaminants from the saltstone waste form. Contaminants were transported through groundwater and air pathways to points of assessment to evaluate compliance (i.e., 100 m from the SDUs). In addition, the potential consequences of an inadvertent human intrusion (IHI) were also evaluated. A number of issues were overcome during the development of these simulations. These issues were identified as part of internal technical reviews. Simulations are developed by people and people make mistakes, so the internal technical review process is a vital step in PA development. Specific examples of resolved issues include a unit-conversion error, an inappropriate definition for a model boundary condition, a model time-stepping issue, and an error in the calculation for the buildup of contaminants in soil. Actions taken to address these issues resulted in an improved product with a better supported technical basis and more defensible results. The identification and correction of these issues are discussed. By understanding these issues, model developers and technical reviewers working on PAs in the future may avoid repeating these types of mistakes. Transparency with respect to these mistakes builds trust between waste management sites, regulators, and stakeholders. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mineral Scale Formation during Crossflow Reverse Osmosis at Constant Flux and Constant Transmembrane Pressure Conditions

Mineral scale formation on membrane surfaces is a significant challenge in reverse osmosis water purification. Laboratory fouling experiments are typically run such that the transmembrane pressure (TMP) is fixed, and the permeate flux decreases over time as scales accumulate on the membrane surface. However, this change in flux means that the hydrodynamic conditions at the membrane surface are continuously changing, which could affect crystallization and foulant deposition processes. Operating under constant permeate flux conditions, in contrast, is advantageous because it keeps the hydrodynamic conditions relatively consistent, making it possible to compare how membrane properties (e.g., surface chemistry) affect fouling propensity. Industrial reverse osmosis operations are not run strictly in either constant TMP or constant flux mode; while they may start at a constant TMP, feed pressure may be periodically adjusted to maintain permeate water production within a specified range. Here, the scarcity of constant permeate flux reverse osmosis scaling experiments reported in the literature frustrates efforts to compare membrane fouling processes under constant TMP and constant flux conditions. For the first time, the evolution of the fouling layer resistance was compared as a function of cumulative permeate volume per membrane area during constant TMP and constant flux reverse osmosis filtrations. Scaling experiments were conducted by challenging commercial reverse osmosis membranes with a model feed solution nearly saturated with calcium sulfate dihydrate (gypsum). At low fluxes, the increase in fouling layer resistance was quantitatively similar for the two operational modes. In contrast, at high fluxes, the fouling layer resistance increased more rapidly in constant flux filtration than in constant TMP filtration. The mechanism of scale formation in constant TMP and constant flux operation was self-limiting and self-reinforcing, respectively.

36 MATERIALS SCIENCE↗

Technoeconomic Benefits of Film-Forming Amine Products Applied to Steam Surface Condensers

In a conventional Rankine cycle, the majority of power plants employ surface condensers that use pumped cooling water to reject heat from the cycle. In such cases, heat rejection occurs in a shell and tube heat exchanger by film-wise condensation of low-pressure steam on stainless steel, titanium, brass, or copper-nickel tubing. To improve the thermal performance of steam surface condensers, a replenishable film-forming substance (FFS) can be ap-plied to the condenser tubing to promote efficient dropwise condensation. Conventionally, film-forming amine prod-uct (FFAP) coatings protect boiler surfaces from oxidative corrosion, which substantially reduces the operation and maintenance costs. To quantify the technical and economic benefits of FFAP coatings applied to condenser tubing due to the promotion of dropwise condensation, a thermal resistance network model was established. Using a rep-resentative steam surface condenser, the improvements in thermal performance (overall heat transfer coefficient) and process parameters (net plant efficiency, cooling water flowrate, and turbine backpressure) were determined due to the enhancement in the condensation heat transfer coefficient. Experimentally measured condensation heat transfer coefficients for common condenser materials were compared with the modeling results and were found to be within attainable bounds. Lastly, the trend in total heat exchanger cost reduction is generalized to understand the trade-off between reduced surface area for heat rejection and increase in coating application costs for a re-plenishable coating system.

20 FOSSIL-FUELED POWER PLANTS↗

Three-dimensional fracture continuum characterization aided by surface time-domain electromagnetics and hydrogeophysical joint inversion—proof-of-concept

Efficient and safe production of hydraulically fractured reservoirs benefits from the prediction of their geometrical attributes. Geophysical methods have the potential to provide data that are sensitive to fracture geometries, alleviating the typically sparse nature of in situ reservoir observations. Moreover, surface-based methods can be logistically and economically attractive since they avoid operational interference with the injection well infrastructure. Here, we investigate the potential of the surface-based time-domain electromagnetic (EM) method. EM methods can play an important role owing to their sensitivity to injection-induced fluid property changes. Two other advantageous factors are the EM signal-enhancing effect of vertical steel-cased wells and the fact that injected proppants can be enhanced to produce a stronger electrical conductivity contrast with the reservoir’s connate fluid. Nevertheless, an optimal fracture characterization will no doubt require the integration of EM and reservoir injection and production data. We hence carry out our investigations within a hydrogeophysical parameter estimation framework where EM data and injection flow rates are combined in a fully coupled way. Given the interdisciplinary nature of coupled hydrogeophysical inverse modeling, we dedicate one section to laying out key aspects in a didactic manner.

58 GEOSCIENCES↗

Fused silica optics damage from downstream intensification on laser-induced damage precursors

Management and control of damage initiation and growth on high-value National Ignition Facility (NIF) optics are critical to its operation. Cone-shaped features are currently being used on the input surfaces to arrest growth of exit surface damage by creating “shadows.” Light refracted from the walls of the cones interferes with the incident beam at the exit surface to create an intensified annulus. Significant exit surface damage was observed at the locations of these annuli. Analysis showed that this damage is consistent with a recently reported new mechanism that degrades damage resistance by dispersing damage precursors over the surface upon exposure to UV laser radiation. This has significant implications for the design and operation of high-energy and power laser systems such as the NIF.

47 OTHER INSTRUMENTATION↗

A low power flexible dielectric barrier discharge disinfects surfaces and improves the action of hydrogen peroxide

There is an urgent need for disinfection and sterilization devices accessible to the public that can be fulfilled by innovative strategies for using cold atmospheric pressure plasmas. Here, we demonstrate a successful novel combination of a flexible printed circuit design of a dielectric barrier discharge (flex-DBD) with an environmentally safe chemical reagent for surface decontamination from bacterial contaminants. Flex-DBD operates in ambient air, atmospheric pressure, and room temperature without any additional gas flow at a power density not exceeding 0.5 W/cm 2 . The flex-DBD activation of a 3% hydrogen peroxide solution results in the reduction in the bacterial load of a surface contaminant of > 6log 10 in 90 s, about 3log 10 and 2log 10 better than hydrogen peroxide alone or the flex-DBD alone, respectively, for the same treatment time. We propose that the synergy between plasma and hydrogen peroxide is based on the combined action of plasma-generated OH · radicals in the hydrogen peroxide solution and the reactive nitrogen species supplied by the plasma effluent. A scavenger method verified a significant increase in OH · concentration due to plasma treatment. Novel in-situ FTIR absorption spectra show the presence of O 3 , NO 2 , N 2 O, and other nitrogen species. Ozone dissolving in the H 2 O 2 solution can effectively generate OH · through a peroxone process. The addition of the reactive nitrogen species increases the disinfection efficiency of the hydroxyl radicals and other oxygen species. Hence, plasma activation of a low concentration hydrogen peroxide solution, using a hand-held flexible DBD device results in a dramatic improvement in disinfection.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spatiotemporal Analyses of Groundwater and Shoreline Cr(VI) Concentrations in the 100 Areas at Hanford

Cleanup efforts have been ongoing since the late 1990s to remediate contaminated waste sites and groundwater in the 100 Areas at the U.S. Department of Energy (DOE) Hanford Site. One of the primary contaminants of concern is hexavalent chromium (Cr(VI)), which was used as a corrosion inhibitor in cooling water for nuclear reactors that formerly operated along the shoreline of the Columbia River. Cleanup efforts have included 1) removal, treatment (as needed), and disposal of contaminated sediments; 2) in situ redox manipulation as a permeable reactive barrier; 3) pump-and-treat; 4) soil flushing; and 5) monitored natural attenuation. DOE’s annual groundwater monitoring reports document the significant reductions in Cr(VI) plume areas that have occurred over the past 10 years or more as a result of these cleanup efforts. The Record of Decision for the 100-HR-3 operable unit specified a cleanup level (CUL) for Cr(VI) in groundwater of 48 µg/L to protect human receptors, and a surface water CUL of 10 µg/L to protect aquatic organisms in the Columbia River. The Record of Decision did not specify point-of-compliance locations for the surface water CUL. Data for 2019 from the six groundwater operable units (OUs) in the 100 Areas indicate that the 48 μg/L groundwater CUL has been achieved in 100% of the wells in the 100-BC and 100-NR OUs, and in 89- 97% of the wells in the other OUs (100-KR, 100-HR-D, 100-HR-H, 100-FR). Data for 2019 indicate that 100% of the aquifer tubes monitored for Cr(VI) in the 100 Areas have concentrations below the 48 μg/L groundwater CUL. However, the 10 μg/L standard has not yet been consistently achieved for both inland groundwater monitoring wells and shoreline aquifer tubes. This report describes a series of data analyses performed to identify consistent relationships, if any, between inland well and shoreline Cr(VI) concentrations within the 100 Areas. To this end, select monitoring data for Cr(VI) measured in groundwater and aquifer tubes at the 100 Areas were analyzed for a 10-year period—2010 to 2019. Relationships between inland groundwater plumes and surface-water points of discharge in and along the Columbia River were examined through several analyses that included inland well and aquifer tube concentrations as a function of distance from the shoreline, evaluation of cumulative probability plots, trend analysis, correlation analysis, cluster analysis, and identification of plume trajectories for each of the 100 Areas. The analyses did not identify consistent relationships between inland groundwater Cr(VI) concentrations and shoreline concentrations within the 100 Areas due to several confounding factors influencing groundwater flow directions and Cr(VI) concentrations. The proximity of groundwater Cr(VI) plumes to the river, and the highly dynamic nature of the river, influence the transport behavior of the plumes and create challenges for quantifying attenuation of Cr(VI) between the inland monitoring wells and shoreline concentrations. Other factors contributing to temporal and spatial Cr(VI) concentrations, as supported by some of the data analyses, include the presence of vadose zone sources, variable sorption behavior, and complexities associated with Cr(VI) mass transfer between the upper and lower aquifers and their interactions with the river. Hence, monitoring to assess compliance with target CULs will need to be determined for each area individually since several factors influence Cr(VI) concentrations in the 100 Areas.

54 ENVIRONMENTAL SCIENCES↗

Numerical Optimization of Spray-Guided Spark Assistance for Cold Idle Operation in a Heavy-Duty Gasoline Compression Ignition Engine

This article describes the results of a response surface model (RSM)-based numerical optimization campaign for spray-guided spark assistance at cold operations in a heavy-duty gasoline compression ignition (GCI) engine. On the basis of an earlier work on spark-assisted GCI cold combustion, a space-filling design of experiments (DoE) method was first undertaken to investigate a multitude of hardware design variables and engine operating parameters. The main design variables included the number of injector nozzles, fuel split quantities and injection timings, and spark timing. The objective variables were engine combustion efficiency (ŋ c ), maximum pressure rise rate (MPRR), and engine-out nitrogen oxide (NO x ) emissions. A total of 150 design candidates were automatically generated using the Sobol sequence method provided by the commercial software package, CAESES. Then, closed-cycle computational fluid dynamic (CFD) spark-assisted GCI simulations under cold idling operations were performed. The outcomes from the CFD-DoE design campaign were utilized to construct high-fidelity RSMs that allowed for further design optimization of the spark plug- and fuel injector-related design variables, along with fuel injection strategy parameters. A merit function with respect to objective variables was formulated with an appropriate weight assignment on each objective variable. Finally, the best design candidate was identified from the RSM-based optimization process and further validated in the CFD analysis. The best design candidate showed the potential to significantly improve combustion efficiency (ŋ c > 90%) over the baseline at cold idle while satisfying MPRR and NOx emissions constraints (MPRR < 5 bar/CAD and NO x < 4.5 g/kWh).

33 ADVANCED PROPULSION SYSTEMS↗

Degrade-Repair Cycle of a Fuel-Forming Photoelectrode

Artificial leaves that produce fuels using sunlight hold promise for sustainably powering the planet, but they require advance- ments in energetic efficiency, cost effectiveness, and operational durability. Herein, we showcase the application of combined surface- sensitive spectroscopic techniques to durability studies that characterize structural changes accompanying functional degradation and go beyond just observing changes in function over time. Further, the photoelectrodes used in this work feature a polymeric surface coating functionalized with molecular complexes that catalyze the hydrogen evolution reaction. Using a polymeric layer to interface the light-harvesting component with catalytic sites enables reassembly of catalysts that detach during operation, establishing a degrade-repair cycle.

14 SOLAR ENERGY↗

Effect of cell compression on the performance and the structure of proton exchange membrane water electrolyzer (PEMWE) assembly

Here, in the field of water electrolysis, the proton exchange membrane water electrolyzer (PEMWE) is currently the most advanced technology for producing hydrogen without emitting CO 2 . Although PEMWE plants are already in operation, further research is needed to improve cell efficiency and reduce the use of rare materials, such as iridium oxide catalysts for the oxygen evolution reaction (OER). One of the main causes of performance loss in PEMWE is the relatively low electric conductivity of the porous transport layer (PTL) and of the anode catalyst layer, which results in ohmic losses and low catalyst utilization during high current density operation. The objective of this study is to investigate how optimization of the PTL and electrode interface can increase the cell performance. To this end, we tested different cell assemblies using fibrous and sintered PTLs, decreasing membrane thickness, reducing iridium loading, and inserting a microporous layer to increase contact surface area. Electrochemical characterization of each cell configuration was systematically performed at various compression levels as the pressure is a crucial parameter influencing the electrode/PTL contact area. In parallel, X-ray microcomputed tomography (micro-CT) was employed to investigate the effects of cell hydration and compression on the structure of PEMWE components. This study combining electrochemistry and micro-CT imaging presents how optimizing the electrode/PTL contact surface area, minimizes ohmic losses, and enables PEMWE operation with low iridium loading at high current densities.

Catalyst - PTL interface↗

Roles of irrigation and reservoir operations in modulating terrestrial water and energy budgets in the Indian subcontinental river basins

Water management activities affect the terrestrial water cycle by increasing water supply and hence changing the partitioning of surface water and energy budgets over irrigated agricultural land, as well as modifying streamflow seasonality through reservoir operations (for irrigation, hydropower generation, and other purposes). Indian sub-continental basins are strongly influenced by human activities. However, the dynamics of how anthropogenic activities interact with the terrestrial water cycle have not been sufficiently studied over Indian sub-continental Basins. In this study, we applied a well-evaluated water management model, coupled with a large-scale land surface hydrological model with irrigation and reservoir operation schemes to examine the impacts of irrigation and reservoir operations on terrestrial water budgets over the Indian sub-continental basins. We conducted two simulations: one NATURAL (i.e., no irrigation and no reservoirs) and water management scenario (i.e., with irrigation and with reservoir regulations, referred to as MANAGED) over 18 basins from 1951 to 2012. The water management impacts were evaluated by comparing a number of key water and energy budget terms such as evapotranspiration (ET), total runoff (TR), land surface temperature (LST), reservoir storage, and discharge. Our results show that water management activities have significant (p-value < 0.05) impacts on ET and LST in most of the river basins during the pre-monsoon season (February-May). Comparing to the NATURAL scenario, ET under the MANAGED scenario is significantly increased in most basins during pre- and post-monsoon seasons especially in semi-arid regions, and LST is reduced predominately in the pre-monsoon season when irrigation water demand is high.

Shah, Harsh L.↗

Multispin Clifford codes for angular momentum errors in spin systems

The physical symmetries of a system play a central role in quantum error correction. Here, in this work we encode a qubit in a collection of systems with angular momentum symmetry (spins), extending the tools developed by Gross for single large spins. By considering large spins present in atomic systems and focusing on their collective symmetric subspace, we develop codes with octahedral symmetry capable of correcting errors up to second order in angular momentum operators. These errors include the most physically relevant noise sources such as microwave control errors and optical pumping. We additionally explore qubit codes that exhibit distance scaling commensurate with the surface code while permitting transversal single-qubit Clifford operations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Role of generic scale invariance in a Mott transition from a U(1) spin-liquid insulator to a Landau Fermi-liquid metal

Highlights: • We look at the role played by generic scale invariance (GSI) in the phase transition between a U(1) spin liquid and a Fermi liquid. • We identify dangerously irrelevant operators in the renormalization group transformation, involved with the GSI. • We highlight novel mean-field dynamics of this Mott quantum criticality, resulting from the GSI. We investigate the role of generic scale invariance in a Mott transition from a U(1) spin-liquid insulator to a Landau Fermi-liquid metal, where there exist massless degrees of freedom in addition to quantum critical fluctuations. Here, the Mott quantum criticality is described by critical charge fluctuations, and additional gapless excitations are U(1) gauge-field fluctuations coupled to a spinon Fermi surface in the spin-liquid state, which turn out to play a central role in the Mott transition. An interesting feature of this problem is that the scaling dimension of effective leading local interactions between critical charge fluctuations differs from that of the coupling constant between U(1) gauge fields and matter-field fluctuations in the presence of a Fermi surface. As a result, there appear dangerously irrelevant operators, which can cause conceptual difficulty in the implementation of renormalization group (RG) transformations. Indeed, we find that the curvature term along the angular direction of the spinon Fermi surface is dangerously irrelevant at this spin-liquid Mott quantum criticality, responsible for divergence of the self-energy correction term in U(1) gauge-field fluctuations. Performing the RG analysis in the one-loop level based on the dimensional regularization method, we reveal that such extremely overdamped dynamics of U(1) gauge-field fluctuations, which originates from the emergent one-dimensional dynamics of spinons, does not cause any renormalization effects to the effective dynamics of both critical charge fluctuations and spinon excitations. However, it turns out that the coupling between U(1) gauge-field fluctuations and both matter-field excitations still persists at this Mott transition, which results in novel mean-field dynamics to explain the nature of the spin-liquid Mott quantum criticality. We discuss physical implications of effective one-dimensional spin dynamics and extremely overdamped gauge dynamics at the Mott quantum criticality.

36 MATERIALS SCIENCE↗