Search NASA⌕ Search

SEARCH · Search NASA

Results for “Surface sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Fast imaging of laser ablation of cerium: Dependence of plasma plume dynamics and structure on native oxide growth

We have imaged the evolution of plasma following nanosecond pulsed laser ablation of cerium in air with sub-10 ns resolution. We find the ablated plasma plume expansion and shape to be strongly dependent on the time after mechanical polishing of the sample surface. After an initial shock front common to both new and aged samples (velocities up to 16 km s ₋1 ), we observe a second front that is relatively localized to the surface vicinity of newly polished samples, but in the case of older samples it moves outward at velocities of up to 4 km s ₋1 . We attribute this behavior to the formation and growth of a native oxide layer on the order of hours after polishing. These results demonstrate that plasma imaging can be used to diagnose the presence of, and evaluate the extent of, thin surface oxides or other compounds that form soon after exposure to some atmosphere. These findings also highlight the need to explicitly consider the presence of such overlayers when modeling laser/metal interaction, when making measurements of vapor phase chemistry, and when analyzing the composition, phase, and morphology of solid particulates formed after the ablation of reactive metals.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bacterial Diversity in Two Neonatal Intensive Care Units (NICUs)

Infants in Neonatal Intensive Care Units (NICUs) are particularly susceptible to opportunistic infection. Infected infants have high mortality rates, and survivors often suffer life-long neurological disorders. The causes of many NICU infections go undiagnosed, and there is debate as to the importance of inanimate hospital environments (IHEs) in the spread of infections. Here, we used culture-independent next-generation sequencing to survey bacterial diversity in two San Diego NICUs and to track the sources of microbes in these environments. Thirty IHE samples were collected from two Level-Three NICU facilities. We extracted DNA from these samples and amplified the bacterial small subunit (16S) ribosomal RNA gene sequence using ‘universal’ barcoded primers. The purified PCR products were pooled into a single reaction for pyrosequencing, and the data were analyzed using QIIME. On average, we detected 93+/-39 (mean +/- standard deviation) bacterial genera per sample in NICU IHEs. Many of the bacterial genera included known opportunistic pathogens, and many were skin-associated (e.g., Propionibacterium). In one NICU, we also detected fecal coliform bacteria (Enterobacteriales) in a high proportion of the surface samples. Comparison of these NICU-derived sequences to previously published high-throughput 16S rRNA amplicon studies of other indoor environments (offices, restrooms and healthcare facilities), as well as human- and soil-associated environments, found the majority of the NICU samples to be similar to typical building surface and air samples, with the notable exception of the IHEs which were dominated by Enterobacteriaceae. Our findings provide evidence that NICU IHEs harbor a high diversity of human-associated bacteria and demonstrate the potential utility of molecular methods for identifying and tracking bacterial diversity in NICUs.

59 BASIC BIOLOGICAL SCIENCES↗

Dereplicating and spatial mapping of secondary metabolites from fungal cultures in situ

Ambient ionization techniques coupled to mass spectrometry have recently become prevalent in natural product research due to their ability to examine secondary metabolites in situ. Identifying, mapping, and monitoring secondary metabolites directly on an organism provides invaluable spatial and temporal details that are lost through traditional extraction processes. Most ambient ionization techniques do not collect mutually supportive data, such as chromatographic retention times and/or UV/VIS spectra, and this can limit the ability to identify certain metabolites, such as differentiating isomers. To overcome this, the droplet liquid microjunction surface sampling probe (droplet LMJ SSP) was coupled with UPLC PDA HRMS MS/MS, thus providing separation, retention times, and UV/VIS data used in traditional dereplication protocols. By capturing these mutually supportive data, the identity of secondary metabolites could be confidently and rapidly assigned in situ. Using the droplet LMJ SSP, a protocol was constructed to analyze the secondary metabolite profile of fungal cultures directly without any sample preparation. The results demonstrate that fungal cultures can be dereplicated from the Petri dish, thus identifying secondary metabolites, including isomers, and confirming them against reference standards. As a result, heat maps, similar to mass spectrometry imaging, can be used to ascertain the location and relative concentration of secondary metabolites directly on the surface and/or surroundings of a fungal culture.

59 BASIC BIOLOGICAL SCIENCES↗

Investigation of Donor and Acceptor Ion Implantation in AlN

AlGaN alloys with high Al composition and AlN based electronic devices are attractive for high voltage, high temperature applications, including microwave power sources, power switches and communication systems. AlN is of particular interest because of its wide bandgap of ~6.1eV which is ideal for power electronic device applications in extreme environments which requires high dose ion implantation. One of the major challenges that need to be addressed to achieve full utilization of AlN for opto and microelectronic applications is the development of a doping strategy for both donors and acceptors. Ion implantation is a particularly attractive approach since it allows for selected-area doping of semiconductors due to its high spatial and dose control and its high throughput capability. Active layers in the semiconductor are created by implanting a dopant species followed by very high temperature annealing to reduce defects and thereby activate the dopants. Recovery of implant damage in AlN requires excessively high temperature. In this SBIR program we began the investigation by simulation of ion beam implantation profiles for Mg, Ge and Si in AlN over wide dose and energy ranges. Si and Ge are implanted to achieve the n-type doping, Mg is investigated as a p-type doping. The simulation of implantation profiles were performed in collaboration between NRL and Agnitron using a commercial software known as Stopping and Range of Ions in Matter (SRIM). The simulation results were then used as the basis for ion implantation of AlN samples. The implanted samples were annealed by an innovative technique under different conditions and evaluated along the way. Raman spectroscopy and XRD were used to determine the crystal quality of the implanted samples, demonstrating the effectiveness of annealing in removing implant induced damage. Additionally, SIMS was used to verify that a nearly uniform doping profile was achieved near the sample surface. The electrical characteristics of the implanted samples were evaluated by TLM and Hall techniques. Generally, the implanted samples before and after annealing were found to be very resistive. Further work is required before the superior properties of AlN can be fully utilized.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhanced surface sampler and process for collection and release of analytes

An enhanced swipe sampler and method of making are described. The swipe sampler is made of a fabric containing selected glass, metal oxide, and/or oxide-coated glass or metal fibers. Fibers are modified with silane ligands that are directly attached to the surface of the fibers to functionalize the sampling surface of the fabric. The swipe sampler collects various target analytes including explosives and other threat agents on the surface of the sampler.

36 MATERIALS SCIENCE↗

Plasmonic Hybrid Biocomposite as an Effective Substrate for Detection of Biomolecules by Surface-Enhanced Raman Spectroscopy

The enhancement of the Raman light scattering signal from the surface of the porous hybrid biocomposites based on polyhydroxybutyrate (PHB), calcium carbonate (CaCO{sub 3}), and nanoplasmonic Ag particles is investigated. Based on PHB, fibrous scaffolds are obtained by the electrospinning technique. The fibrous scaffolds have been covered by CaCO{sub 3} and Ag nanoparticles by means of mineralization in salt solutions and Ag reduction reaction. Successful formation of the CaCO{sub 3} and Ag nanoparticles on the scaffold surface has been confirmed by the data of scanning electron microscopy, x-ray diffraction analysis, and infrared spectroscopy. Surface-enhanced Raman spectroscopy (SERS) of the obtained sample surface has demonstrated a significant enhancement of the Rhodamine 6G signal (E{sub f} > 10{sup 5}) in comparison with the reference sample where the analyte concentration and the laser power were 100 times higher. Thus, the present research has confirmed prospects for the application of biocomposites based on polyhydroxybutyrate for detection and investigation of biomolecules by the SERS method.

36 MATERIALS SCIENCE↗

Analysis of Chloroquine and Metabolites Directly from Whole-body Animal Tissue Sections by Liquid Extraction Surface Analysis (LESA) and Tandem Mass Spectrometry

The rapid and direct analysis of the amount and spatial distribution of exogenous chloroquine and chloroquine metabolites from tissue sections by liquid extraction surface sampling analysis coupled with tandem mass spectrometry (LESA-MS) was demonstrated. LESA-MS results compared well with previously published chloroquine quantification data collected by organ excision, extraction and fluorescent detection. The ability to directly sample and analyze spatially-resolved exogenous molecules from tissue sections with minimal sample preparation and analytical method development has the potential to facilitate the assessment of target tissue penetration of pharmaceutical compounds, to establish pharmacokinetic/pharmacodynamic (PK/PD) relationships, and to complement established pharmacokinetic methods used in the drug discovery process during tissue distribution assessment.

chloroquine↗

Structural studies of ZnS:Cu (5 at %) nanocomposites in porous Al{sub 2}O{sub 3} of different thicknesses

We present EXAFS, XANES, and X-ray diffraction data on nanoscale ZnS:Cu (5 at %) structures fabricated by the thermal deposition of a ZnS and Cu powder mixture in porous anodic alumina matrices with a pore diameter of 80 nm and thicknesses of 1, 3, and 5 μm. The results obtained are compared with data on ZnS:Cu films deposited onto a polycor surface. According to X-ray diffraction data, the samples contain copper and zinc compounds with sulfur (Cu{sub 2}S and ZnS, respectively); the ZnS compound is in the cubic (sphalerite) and hexagonal (wurtzite) modifications. EXAFS and XANES studies at the K absorption edges of zinc and copper showed that, in samples deposited onto polycor and alumina with thicknesses of 3 and 5 μm, most copper atoms form the Cu{sub 2}S compound, while, in the sample deposited onto a 1-μm-thick alumina layer, copper atoms form metallic particles on the sample surface. Copper crystals affect the Zn–S interatomic distance in the sample with a 1-μm-thick porous Al{sub 2}O{sub 3} layer; this distance is smaller than in the other samples.

36 MATERIALS SCIENCE↗

In-line measurements of below-the-surface food deformation during drying with an interference-based optical fiber strain sensor

Real-time measurements of food deformation are important for quality control in drying, yet they pose significant challenges. In this study, we developed an interference-based optical fiber strain sensor to enable in-line, continuous, below-the-surface strain measurements in drying of soft food samples. Compared to a strain resolution of 8 × 10 -4 at zero strain and 7.2 × 10 -3 at 0.20 strain reported in our previously published work, the present study achieves markedly improved resolutions of 1.3 × 10 -4 at zero strain and 7.8 × 10 -4 at 0.25 strain, which strains are the lower and higher boundaries of the dynamic range, respectively. This nearly order-of-magnitude improvement is attributed to the unique interference-based sensing mechanism, no need for calibration to convert optical signals to strain, and the system-design-enabled immunity to fiber-disk misalignments and light source intensity fluctuations. To demonstrate the in-line process monitoring, deformation measurements of fresh banana slices and sugar cookie doughs were carried out in a benchtop oven and an industrial-scale hot-air pilot dryer, respectively. In both dryers, strain measurements were continuously measured during the whole drying process at various depths and radii below the sample surfaces, with the strains up to 25%. Computer vision was used only in the benchtop drying to confirm the faithfulness of the fiber sensor measurements and cannot provide below-the-surface measurements. The measured spatiotemporal deformation allowed us to confirm the shell-hardening effect and to determine the speed and location of large deformation changes in the whole drying process, the latter of which is related to the sample cracking. To the best of the authors’ knowledge, this study is the first to report on an interferometry-based fiber sensor to measure food deformation. This sensor and the sensing mechanism have high potential for real-time process monitoring and control to prevent over-drying or cracking during drying processes.

47 OTHER INSTRUMENTATION↗

Evaluation of a high-throughput method for processing sponge-stick samples to detect viable, non-spore-forming biothreat agents

After a bioterrorism incident, surface sampling is often used to determine the extent of contamination and exposure, guiding decontamination efforts and decisions for re-occupancy of affected sites. The sponge-stick (SS) is a preferred and commonly used device for sample collection to detect both spore-forming and non-spore-forming biothreat agents from non-porous surfaces. Here, in this study, a recently developed high-throughput method (HTM) for processing SS samples to detect viable Bacillus anthracis spores was adapted for detection of non-spore-forming biothreat agents, Yersinia pestis and Francisella tularensis. The scalable HTM was used to process up to 20 SS samples simultaneously, compared to the current stomacher-based method which processes one SS at a time. Comparisons of the HTM and the stomacher-based method were statistically indistinguishable for most experiments (P > 0.05) with HTM recoveries of 37–60 % for Y. pestis inoculated at 102–103 cells/SS and held 48 h at 4 °C to mimic sample transport/storage. The HTM was integrated with Rapid Viability-Polymerase Chain Reaction (RV-PCR) analysis to detect viable Y. pestis in the presence of particulate contamination (Arizona Test Dust, ATD). This approach detected Y. pestis inoculated at 20 cells/SS and ATD did not impact detection (P > 0.05). F. tularensis showed significantly lower recoveries between no-hold time and 48-h hold time (4 °C, P < 0.05) using the HTM, which further testing showed could be due to toxicity of the neutralizing buffer used for SS pre-wetting. With modifications, this method could enhance throughput capacity while maintaining similar recovery efficiencies to current methods for other non-spore-forming bacterial pathogens.

Biological and medical sciences↗

Study of Material Compatibility for a Thermal Energy Storage System with Phase Change Material

The suitability of stainless steel 316L and Inconel 625 for use in a latent heat thermal energy storage (TES) system was investigated. A NaCl–NaF eutectic mixture with a melting temperature of 680 °C was used as the phase change material (PCM). Containers were filled with the PCM prior to heating to 750 °C, then examined after 100 and 2500 h of high-temperature exposure by analyzing the material surface and cross-section areas. A small amount of corrosion was present in both samples after 100 h. Neither sample suffered significant damage after 2500 h. The undesirable inter-granular grain boundary attack found in SS316L samples was in the order of 1–2 µm in depth. On Inconel 625 sample surface, an oxide complex formed, resisting material dissolution into the PCM. The surface morphology of tested samples remained largely unchanged after 2500 h, but the corrosion pattern changed from an initially localized corrosion penetration to a more uniform type. After 2500 h, the corrosion depth of Inconel 625 remained at roughly 1–2 µm, indicating that the corrosion rate decelerated. Both materials demonstrated good compatibility with the chosen NaF–NaCl eutectic salt, but the low corrosion activity in Inconel 625 samples shows a performance advantage for long term operation.

25 ENERGY STORAGE↗

The right conditions for high-precision dynamic temperature and heat capacity measurement via pyrometry and conductivity

The pursuit of accurate bulk temperature T under extreme conditions has been a long-standing goal of the high pressure science community, complicated by a lack of data to inform models. To reach these extremely high-pressure, high-temperature (high P − T) conditions, a combination of dynamic and heated static experiments (e.g., diamond or gem anvil cel experiments) are used. For example, in a diamond anvil cell (DAC) experiment, a sample placed in the DAC is first pressurized. Following pressurization, the sample T is increased either by heating the entire DAC (usually using resistive heating, and limited to ∼1000K) or by applying intense laser power to the sample surfaces. In a dynamic experiment, the process of pressurizing the sample also heats it. In the case of shock physics experiments, such heating is substantial, easily reaching thousands of Kelvin; in our work we have seen T ∼17000K. Most methods of measuring temperature at ambient are not compatible with experiments under these high-pressure, high-temperature conditions: thermocouples break, melt, or have conductivity properties that differ from ambient where they are calibrated; thermometers would melt; both are too slow. As a result most methods are based on non-contact techniques such as x-ray diffraction broadening, neutron scattering, or optical methods. Of these, optical methods using the visible and near-infrared region of the spectrum are the most commonly used as the sources and detectors are readily available. In the case of optical methods the optical depth, and therefore the measurement location, is limited to the surface. When a window or anvil material is used, heat flows from the sample into the window/anvil. Likewise, if the sample undergoes a change in thermodynamic state, such as expansion upon release, different T may be expected. As a result, the surface or apparent temperature T app measurement will differ from the bulk or interior temperature that is desired. This surface measurement must be related to the bulk measurement using thermal transport models and material models. While it is tempting to conclude that one should just use x-ray methods that directly probe the interior, even these methods have been shown to depend on thermal transport and material models. Regardless of the method used to create the high P − T condition, therefore, we must understand the role of thermal transport and material models upon our interpretation of the T measurement, as well as the errors and uncertainties associated with the choice of models used in the analysis. This is a substantial area of research and this paper is by no means a complete survey of the relevant sources of uncertainty. For example, we have yet to begin to address alternate transport models in a detailed manner (e.g., Tan-Ahrens), or the many models that use additional layers to approximate melting, turbulence, or epitaxial phenomena). Likewise, we have not explored the impact upon uncertainty of thermal models that use temperature-dependent thermal transport coefficients, or the wide range of material models that can be applied. Instead, this paper focuses on using one simple model, the Urtiew-Grover model, to understand the sources of error in T measurement so that we may identify how best to focus future research efforts to return the best improvements and avoid working on over-optimizing a single type of measurement. To this end, we work through some of the best and worst case scenarios for T measurement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In Situ Apparatus to Study Gas–Metal Reactions and Wettability at High Temperatures for Hot-Dip Galvanizing Applications

The understanding of gas–metal reactions and related surface wettability at high temperatures is often limited due to the lack of in situ surface characterization. Ex situ transfers at low temperature between annealing furnace, wettability device, and analytical tools induce noticeable changes of surface composition distinct from the reality of the phenomena.Therefore, a high temperature wettability device was designed in order to allow in situ sample surface characterization by x-rays photoelectron spectroscopy after gas/metal and liquid metal/solid metal surface reactions. Such airless characterization rules out any contamination and oxidation of surfaces and reveals their real composition after heat treatment and chemical reaction. The device consists of two connected reactors, respectively, dedicated to annealing treatments and wettability measurements. Heat treatments are performed in an infrared lamp furnace in a well-controlled atmosphere conditions designed to reproduce gas–metal reactions occurring during the industrial recrystallization annealing of steels. Wetting experiments are carried out in dispensed drop configuration with the precise control of the deposited droplets kinetic energies. The spreading of drops is followed by a high-speed CCD video camera at 500-2000 frames/s in order to reach information at very low contact time. First trials have started to simulate phenomena occurring during recrystallization annealing and hot-dip galvanizing on polished pure Fe and FeAl8 wt.% samples. The results demonstrate real surface chemistry of steel samples after annealing when they are put in contact with liquid zinc alloy bath during hot-dip galvanizing. The wetting results are compared to literature data and coupled with the characterization of interfacial layers by FEG-Auger. It is fair to conclude that the results show the real interest of such in situ experimental setup for interfacial chemistry studies.

36 MATERIALS SCIENCE↗

Preliminary Test Design and Plan for a Canister Deposition Field Demonstration

This report provides a high-level test plan for deploying three commercial 32PTH2 spent nuclear fuel (SNF) canisters inside NUHOMS Advanced Horizontal Storage Modules (AHSM) from Orano (formerly Transnuclear Inc.). The details contained in this report represent the best designs and approaches explored for testing as of this publication. Given the rapidly developing nature of this test program, some of these plans may change to accommodate new objectives or adapt in response to conflicting requirements. The goal of the testing is to collect highly defensible and detailed surface deposition measurements from the surface of dry storage systems in a marine coastal environment to guide chloride-induced stress corrosion crack (CISCC) research. To facilitate surface sampling, the otherwise highly prototypic dry storage systems will not contain SNF but rather will be electrically heated to mimic the thermal-hydraulic environment. Instrumentation throughout the canister, storage module, and environment will provide an extensive amount of information for the use of model validation. Manual sampling over a comprehensive portion of the canister surface at regular time intervals will offer a high-fidelity quantification of the conditions experienced in a harsh yet realistic environment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Status Update for the Canister Deposition Field Demonstration

This report updates the high-level test plan for evaluating surface deposition on three commercial 32PTH2 spent nuclear fuel (SNF) canisters inside NUTECH Horizontal Modular Storage (NUHOMS) Advanced Horizontal Storage Modules (AHSM) from Orano (formerly Transnuclear Inc.) and provides a description of the surface characterization activities that have been conducted to date. The details contained in this report represent the best designs and approaches explored for testing as of this publication. Given the rapidly developing nature of this test program, some of these plans may change to accommodate new objectives or requirements. The goal of the testing is to collect highly defensible and detailed surface deposition measurements from the surface of dry storage canisters in a marine coastal environment to guide chloride-induced stress corrosion crack (CISCC) research. To facilitate surface sampling, the otherwise highly prototypic dry storage systems will not contain SNF but rather will be electrically heated to mimic the thermal-hydraulic-environment. Instrumentation throughout the canister, storage module, and environment will provide an extensive amount of information for the use of model validation. Manual sampling over a comprehensive portion of the canister surface at regular time intervals will offer a high-fidelity quantification of the conditions experienced in a harsh yet realistic environment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Status Update for the Canister Deposition Field Demonstration

This report updates the high-level test plan for evaluating surface deposition on three commercial 32PTH2 spent nuclear fuel (SNF) canisters inside NUTECH Horizontal Modular Storage (NUHOMS) Advanced Horizontal Storage Modules (AHSMs) from Orano (formerly Transnuclear Inc.) and provides a description of the surface characterization activities that have been conducted to date. The details contained in this report represent the best designs and approaches explored for testing as of this publication. Given the rapidly developing nature of this test program, some of these plans may change to accommodate new objectives or requirements. The goal of the testing is to collect highly defensible and detailed dust deposition measurements from the surface of dry storage canisters in a marine coastal environment to guide chloride-induced stress corrosion crack (CISCC) research. To facilitate surface sampling, the otherwise highly prototypic dry storage systems will not contain SNF but rather will be electrically heated to mimic the decay heat and thermal hydraulic environment. Test and heater design is supported by detailed computational fluid dynamics modeling. Instrumentation throughout the canister, storage module, and environment will provide extensive information about thermal-hydraulic behavior. Manual sampling over a comprehensive portion of the canister surface at regular time intervals will offer a high-fidelity quantification of the conditions experienced in a harsh yet realistic environment. Functional testing of the finalized heater assemblies and test apparatus is set to begin in December 2022. The proposed delivery of the canisters to the host test site is June/July 2023, which is well ahead of when the AHSM installations would be completed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Multislice forward modeling of coherent surface scattering imaging on surface and interfacial structures

To study nanostructures on substrates, surface-sensitive reflection-geometry scattering techniques such as grazing incident small angle X-ray scattering are commonly used to yield an averaged statistical structural information of the surface sample. Grazing incidence geometry can probe the absolute three-dimensional structural morphology of the sample if a highly coherent beam is used. Coherent surface scattering imaging (CSSI) is a powerful yet non-invasive technique similar to coherent X-ray diffractive imaging (CDI) but performed at small angles and grazing-incidence reflection geometry. A challenge with CSSI is that conventional CDI reconstruction techniques cannot be directly applied to CSSI because the Fourier-transform-based forward models cannot reproduce the dynamical scattering phenomenon near the critical angle of total external reflection of the substrate-supported samples. To overcome this challenge, we have developed a multislice forward model which can successfully simulate the dynamical or multi-beam scattering generated from surface structures and the underlying substrate. The forward model is also demonstrated to be able to reconstruct an elongated 3D pattern from a single shot scattering image in the CSSI geometry through fast-performing CUDA-assisted PyTorch optimization with automatic differentiation.

77 NANOSCIENCE AND NANOTECHNOLOGY↗