Search NASA⌕ Search

SEARCH · Search NASA

Results for “Surface sampling probe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Development of an accelerator-based diagnostic for plasma-facing surfaces in magnetic confinement devices

The focus of this work was the development of the Accelerator-based In-situ Material Surveillance (AIMS) diagnostic. The understanding of plasma-material interaction processes in fusion devices has been greatly hampered by the lack of ability to measure the surface ~micron layers of solid surfaces that are in contact with and greatly modified by the boundary fusion plasma. AIMS was the first diagnostic developed and deployed that allowed non-destructive surface measurements with adequate spatial and time resolution. The deployment was primarily carried out on the Alcator C-Mod tokamak. AIMS diagnostic goal is to remotely generate isotopic concentration maps on a plasma shot-to-shot timescale that cover a large fraction of the plasma-facing surface inside of a magnetic fusion device without the need for vacuum breaks or physical access to the material surfaces. The diagnostic used a compact (~ 1 m), high-current (~ 1 milliamp) radio-frequency quadrupole accelerator to inject 0.9 MeV deuterons into the Alcator C-Mod tokamak. The tokamak magnetic fields were controlled – in between plasma shots – to steer the deuterons to material surfaces where the deuterons cause high-Q nuclear reactions with low-Z isotopes up to 5 microns into the material. The induced neutrons and gamma rays are measured with scintillation detectors; energy spectra analysis provides quantitative reconstruction of surface compositions. Experimental validation showed that low-Z isotopes such as deuterium and boron can be quantified on the material surfaces, and that magnetic steering provides access to different measurement locations. AIMS measurements of D retention on inner wall PFCs were acquired during diverted and limited plasma operations and during wall conditioning experiments om Alcator C-Mod. Intershot measurements demonstrate the local erosion and co-deposition of boron films on PFC surfaces with a constant D-B ratio. This is consistent with previous results suggesting that D co-=deposition with boron is insufficient to account for the net retention observed in Alcator C-Mod. Changes in deuterium concentration during boronization, electron cyclotron and glow cleanings were also measured. These initial results were limited to studying low-Z surface properties, because the Coulomb barrier precludes nuclear reactions between high-Z elements and the ~1 MeV AIMS deuteron beam. In order to measure the high-Z erosion of interest in Alcator C-Mod and future fusion devices, a new technique using deuteron-induced gamma emission and a low-Z depth marker was developed using implanted depth markers as a method of measuring bulk erosion and redeposition. This method is dubbed DEA: Depth marker Erosion with AIMS. DEA simulations and experiments were used to validate this technique, both in the laboratory and via experiments in the EAST tokamak. Based on these results, the DEA technique, using ion beam implanted depth markers as a reference to the surface in order to monitor surfaces for erosion and redeposition, is a viable option as a diagnostic, both in and ex situ. These markers show stability to temperature, the tokamak environment, and multiple probing beams. The ex-situ (eDEA) method, which uses resonances in the cross sections of gamma producing reactions to track the surface, was used to successfully measure erosion in samples that were exposed in the EAST tokamak. The in-situ (iDEA) method, which uses the gamma yield ratio to monitor changes to the surface, was used to differentiate between markers implanted to different depths. Both techniques were successfully simulated, and both presented unique challenges experimentally and in data analysis. In particular, the eDEA probing beam was found to have energy variations leading to initial experimental uncertainty, and the iDEA gamma spectra had conflicting gamma peaks which make data analysis difficult. However, the end result is a promising framework for a diagnostic technique that supplements the abilities of AIMS and expands the possibilities of surface diagnostics in fusion devices. While the results of this work are overwhelmingly encouraging for further development of AIMS in general, and the DEA technique specifically, several areas require significant development before this diagnostic is as robust and widely applicable as a surface diagnostic ought to be. Recommended future work includes the development of a cross section/yield measurement database, erosion tests with secondary verification of results using a fiducial mark from a focused ion beam, and acquiring a new accelerator with a more reliable high energy proton and deuterium beam The project resulted in 14 publications, including the PhD theses of three MIT graduate students, cited in the included bibliography.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation of Corrosion Behavior of Carbide Phase Strengthened Nickel‐Based Alloy in Molten Fluoride Salt

The corrosion behavior of a high creep strength carbide-phase strengthened Ni-based alloy in molten FLiNaK (LiF-NaF-KF: 46.5-11.5-42 mol%) salt in the temperature range of 700°C–750°C has been investigated as a part of the development of structural alloys for fluoride salt-based molten salt reactors (MSRs). The alloy composition was designed based on Hastelloy-N, but with the goal of improving creep strength. Cr depletion depth, a measure of corrosion, was observed to be single micrometers after several hundred hours of corrosion testing. Sequential corrosion testing involving testing of pre-tested samples in fresh salt coupled with SEM-EDS, scanning transmission electron microscopy (STEM) examinations and thermodynamic and kinetic modeling, suggest that the corrosion rate at the alloy-salt interface is governed by diffusion of elements from the alloy bulk to the surface. The carbide phases in the corrosion-tested sample microstructure were identified to be largely M 6 C-type Mo-rich carbides and MC-type mixed carbides. Atom probe tomography (APT) showed some partitioning of Cr and Ti to the carbide phase and showed the carbide phases to be stable at the salt-facing surface.

Gordon, Ryan [Univ. of Wisconsin, Madison, WI (Uni↗

Direct isotopic analysis of solid uranium particulates on cotton swipes by microextraction-ICP-MS

Direct isotope ratio analysis of solid uranium particulates on cotton swipes was achieved using a solution-based microextraction technique, coupled to a quadrupole inductively coupled plasma - mass spectrometer (ICP-MS). This microextraction-ICP-MS methodology provides rapid isotopic analysis which could be applicable to nuclear safeguards measurements. Particulates of uranyl nitrate hexahydrate (UO 2 (NO 3 ) 2 ·6H 2 O) and uranyl fluoride (UO 2 F 2 ) ranging from 6 μm to 40 μm in length were transferred to cotton swipes with a particle manipulator. The microextraction probe then delivers a 5% nitric acid (HNO3) solvent onto the swipe surface to extract the uranium species. The extracted sample is then delivered to the ICP-MS for isotopic determination. The majority of uranium signal (~99% and ~94% for UO2(NO3)2·6H2O and UO 2 F 2 , respectively) was detected in the first 15 s extraction, while subsequent extractions on the same location had low or no U signal, suggesting near complete removal of the solid uranium compounds from the swipe surface. Ten samples (for each of the uranium compounds), were analyzed for their isotopic composition. For UO 2 (NO 3 ) 2 ·6H 2 O, the determined isotope ratios resulted in a % relative difference (% RD) from the referenced isotope ratios of 0.97, 1.0, and 7.3% for 234 U/ 238 U, 235 U/ 238 U, and 236 U/ 238 U, respectively. The % RD of the UO 2 F 2 isotope ratios were 1.9 and 0.60% for 234 U/ 238 U and 235 U/ 238 U, respectively. The preliminary limits of detection were determined to be 0.002, 0.4, and 60 pg for 234 U, 235 U and 238 U, respectively This work demonstrates that microextraction ICP-MS is a rapid and sensitive method that could directly determine uranium isotope ratios of UO 2 (NO 3 ) 2 ·6H 2 O and UO 2 F 2 particulates on cotton swipes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mapping O 2 concentration in ex-vivo tissue samples on a fast PLIM macro-imager

O 2 PLIM microscopy was employed in various studies, however current platforms have limitations in sensitivity, image acquisition speed, accuracy and general usability. We describe a new PLIM imager based on the Timepix3 camera (Tpx3cam) and its application for imaging of O 2 concentration in various tissue samples stained with a nanoparticle based probe, NanO 2 -IR. Upon passive staining of mouse brain, lung or intestinal tissue surface with minute quantities of NanO 2 -IR or by microinjecting the probe into the lumen of small or large intestine fragments, robust phosphorescence intensity and lifetime signals were produced, which allow mapping of O 2 in the tissue within 20 s. Inhibition of tissue respiration or limitation of O 2 diffusion to tissue produced the anticipated increases or decreases in O 2 levels, respectively. The difference in O 2 concentration between the colonic lumen and air-exposed serosal surface was around 140 µM. Furthermore, subcutaneous injection of 5 µg of the probe in intact organs (a paw or tail of sacrificed mice) enabled efficient O 2 imaging at tissue depths of up to 0.5 mm. Overall, the PLIM imager holds promise for metabolic imaging studies with various ex vivo models of animal tissue, and also for use in live animals.

59 BASIC BIOLOGICAL SCIENCES↗

CARMA SURVEY TOWARD INFRARED-BRIGHT NEARBY GALAXIES (STING): MOLECULAR GAS STAR FORMATION LAW IN NGC 4254

This study explores the effects of different assumptions and systematics on the determination of the local, spatially resolved star formation law. Using four star formation rate (SFR) tracers (H{alpha} with azimuthally averaged extinction correction, mid-infrared 24 {mu}m, combined H{alpha} and mid-infrared 24 {mu}m, and combined far-ultraviolet and mid-infrared 24 {mu}m), several fitting procedures, and different sampling strategies, we probe the relation between SFR and molecular gas at various spatial resolutions (500 pc and larger) and surface densities ({Sigma}{sub H{sub 2}})approx. 10-245 M{sub sun} pc{sup -2}) within the central {approx}6.5 kpc in the disk of NGC 4254. We explore the effect of diffuse emission using an unsharp masking technique with varying kernel size. The fraction of diffuse emission, f{sub DE}, thus determined is a strong inverse function of the size of the filtering kernel. We find that in the high surface brightness regions of NGC 4254 the form of the molecular gas star formation law is robustly determined and approximately linear ({approx}0.8-1.1) and independent of the assumed fraction of diffuse emission and the SFR tracer employed. When the low surface brightness regions are included, the slope of the star formation law depends primarily on the assumed fraction of diffuse emission. In such a case, results range from linear when the fraction of diffuse emission in the SFR tracer is f{sub DE} {approx}< 30% (or when diffuse emission is removed in both the star formation and the molecular gas tracer) to super-linear ({approx}1.4) when f{sub DE} {approx}> 50%. We find that the tightness of the correlation between gas and star formation varies with the choice of star formation tracer. The 24 {mu}m SFR tracer by itself shows the tightest correlation with the molecular gas surface density, whereas the H{alpha} corrected for extinction using an azimuthally averaged correction shows the highest dispersion. We find that for R < 0.5R{sub 25} the local star formation efficiency is constant and similar to that observed in other large spirals, with a molecular gas depletion time {tau}{sub dep} {approx} 2 Gyr.

79 ASTRONOMY AND ASTROPHYSICS↗

Ultrafast formation of domain walls of a charge density wave in SmTe 3

We study ultrafast x-ray diffraction on the charge density wave (CDW) of SmTe 3 using an x-ray free-electron laser. The high momentum and time resolution afforded by the x-ray laser enabled capturing fine wave-vector and time-dependent features of the CDW that originate from fast (in time) and sharp (in real space) variations of the CDW lattice distortion, which we attribute to an inversion of the order parameter. These domain inversions occur near the surface and are caused by the short penetration depth of the near-infrared pump with the wavelength centered at 800 nm, resulting in CDW domain walls perpendicular to the sample surface. These domain walls break the CDW long-range order on the scale of the x-ray probe depth, controlled experimentally by the x-ray incidence angle and suppress the diffraction intensity of the CDW for times much longer than the ~1–ps recovery of the electronic gap observed in time and angle-resolved photoemission spectroscopy. We model the spatial and temporal dependences of the order parameter using a simple Ginzburg-Landau model with all the parameters obtained from the published literature. We find reasonable agreement between the calculated and the measured diffraction across the momentum, time, fluence, and incidence angle dependence without adjusting any parameters. In conclusion, we reconstruct the spatial and temporal dependences of the lattice order parameter and find that at long times, depending on the pump fluence, multiple domain walls remain at distances of a few nanometers from the surface.

36 MATERIALS SCIENCE↗

Thin-layer chromatography and mass spectrometry coupled using proximal probe thermal desorption with electrospray or atmospheric pressure chemica lionization

An atmospheric pressure proximal probe thermal desorption sampling method coupled with secondary ionization by electrospray or atmospheric pressure chemical ionization was demonstrated for the mass spectrometric analysis of a diverse set of compounds (dyestuffs, pharmaceuticals, explosives and pesticides) separated on various high-performance thin-layer chromatography plates. Line scans along or through development lanes on the plates were carried out by moving the plate relative to a stationary heated probe positioned close to or just touching the stationary phase surface. Vapors of the compounds thermally desorbed from the surface were drawn into the ionization region of a combined electrospray ionization/atmospheric pressure chemical ionization source where they merged with reagent ions and/or charged droplets from a corona discharge or an electrospray emitter and were ionized. The ionized components were then drawn through the atmospheric pressure sampling orifice into the vacuum region of a triple quadrupole mass spectrometer and detected using full scan, single ion monitoring, or selected reaction monitoring mode. Studies of variable parameters and performance metrics including the proximal probe temperature, gas flow rate into the ionization region, surface scan speed, read-out resolution, detection limits, and surface type are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Model electrode structures for studies of electrocatalyst degradation.

Proton exchange membrane fuel cells are being extensively studied as power sources because of their technological advantages such as high energy efficiency and environmental friendliness. The most effective catalyst in these systems consists of nanoparticles of Pt or Pt-based alloys on carbon supports. Understanding the role of the nanoparticle size and structure on the catalytic activity and degradation is needed to optimize the fuel cell performance and reduce the noble metal loading. One of the more significant causes of fuel cell performance degradation is the cathode catalyst deactivation. There are four mechanisms considered relevant to the loss of electrochemically active surface area of Pt in the fuel cell electrodes that contribute to cathode catalyst degradation including: catalyst particle sintering such as Ostwald ripening, migration and coalescence, carbon corrosion and catalyst dissolution. Most approaches to study this catalyst degradation utilize membrane electrode assemblies (MEAs), which results in a complex system where it is difficult to deconvolute the effects of the metal nanoparticles. Our research addresses catalyst degradation by taking a fundamental approach to study electrocatalyst using model supports. Nanostructured particle arrays are engineered directly onto planar glassy carbon electrodes. These model electrocatalyst structures are applied to electrochemical activity measurements using a rotating disk electrode and surface characterization by scanning electron microscopy. Sample transfer between these measurement techniques enables examination of the same catalyst area before and after electrochemical cycling. This is useful to probe relationships between electrochemical activity and catalyst structure such as particle size and spacing. These model systems are applied to accelerated aging studies of activity degradation. We will present our work demonstrating the mechanistic aspects of catalyst degradation using this simplified geometric system. The active surface area loss observed in repeated cyclic voltammetry is explained through characterization and imaging of the same RDE electrode structures throughout the aging process.

30 DIRECT ENERGY CONVERSION↗

Manipulating Ferroelectrics through Changes in Surface and Interface Properties

Ferroelectric materials are used in many applications of modern technologies including information storage, transducers, sensors, tunable capacitors, and other novel device concepts. In many of these applications, the ferroelectric properties, such as switching voltages, piezoelectric constants, or stability of nanodomains, are crucial. For any application, even for material characterization, the material itself needs to be interfaced with electrodes. On the basis of the structural, chemical, and electronic properties of the interfaces, the measured material properties can be determined by the interface. This is also true for surfaces. However, the importance of interfaces and surfaces and their effect on experiments are often neglected, which results in many dramatically different experimental results for nominally identical samples. Therefore, it is crucial to understand the role of the interface and surface properties on internal bias fields and the domain switching process. Here, the nanoscale ferroelectric switching process and the stability of nanodomains for Pb(Zr,Ti)O 3 thin films are investigated by using scanning probe microscopy. Interface and surface properties are modulated through the selection/redesign of electrode materials as well as tuning the surface-near oxygen vacancies, which both can result in changes of the electric fields acting across the sample, and consequently this controls the measured ferroelectric and domain retention properties. By understanding the role of surfaces and interfaces, ferroelectric properties can be tuned to eliminate the problem of asymmetric domain stability by combining the effects of different electrode materials. Lastly, this study forms an important step toward integrating ferroelectric materials in electronic devices.

30 DIRECT ENERGY CONVERSION↗

Bacterial Immobilization for Imaging by Atomic Force Microscopy

AFM is a high-resolution (nm scale) imaging tool that mechanically probes a surface. It has the ability to image cells and biomolecules, in a liquid environment, without the need to chemically treat the sample. In order to accomplish this goal, the sample must sufficiently adhere to the mounting surface to prevent removal by forces exerted by the scanning AFM cantilever tip. In many instances, successful imaging depends on immobilization of the sample to the mounting surface. Optimally, immobilization should be minimally invasive to the sample such that metabolic processes and functional attributes are not compromised. By coating freshly cleaved mica surfaces with porcine (pig) gelatin, negatively charged bacteria can be immobilized on the surface and imaged in liquid by AFM. Immobilization of bacterial cells on gelatin-coated mica is most likely due to electrostatic interaction between the negatively charged bacteria and the positively charged gelatin. Several factors can interfere with bacterial immobilization, including chemical constituents of the liquid in which the bacteria are suspended, the incubation time of the bacteria on the gelatin coated mica, surface characteristics of the bacterial strain and the medium in which the bacteria are imaged. Overall, the use of gelatin-coated mica is found to be generally applicable for imaging microbial cells.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Probing thermal conductivity of subsurface, amorphous layers in irradiated diamond

In this study, we report on the thermal conductivity of amorphous carbon generated in diamond via nitrogen ion implantation (N 3+ at 16.5 MeV). Here, transmission electron microscopy techniques demonstrate amorphous band formation about the longitudinal projected range, localized approximately 7 μm beneath the sample surface. While high-frequency time-domain thermoreflectance measurements provide insight into the thermal properties of the near-surface preceding the longitudinal projected range depth, a complimentary technique, steady-state thermoreflectance, is used to probe the thermal conductivity at depths which could not otherwise be resolved. Through measurements with a series of focusing objective lenses for the laser spot size, we find the thermal conductivity of the amorphous region to be approximately 1.4 W m –1 K –1 , which is comparable to that measured for amorphous carbon films fabricated through other techniques.

36 MATERIALS SCIENCE↗

Torsional force microscopy of van der Waals moirés and atomic lattices

In a stack of atomically thin van der Waals layers, introducing interlayer twist creates a moiré superlattice whose period is a function of twist angle. Changes in that twist angle of even hundredths of a degree can dramatically transform the system’s electronic properties. Setting a precise and uniform twist angle for a stack remains difficult; hence, determining that twist angle and mapping its spatial variation is very important. Techniques have emerged to do this by imaging the moiré, but most of these require sophisticated infrastructure, time-consuming sample preparation beyond stack synthesis, or both. In this work, we show that torsional force microscopy (TFM), a scanning probe technique sensitive to dynamic friction, can reveal surface and shallow subsurface structure of van der Waals stacks on multiple length scales: the moirés formed between bi-layers of graphene and between graphene and hexagonal boron nitride (hBN) and also the atomic crystal lattices of graphene and hBN. In TFM, torsional motion of an Atomic Force Microscope (AFM) cantilever is monitored as it is actively driven at a torsional resonance while a feedback loop maintains contact at a set force with the sample surface. TFM works at room temperature in air, with no need for an electrical bias between the tip and the sample, making it applicable to a wide array of samples. It should enable determination of precise structural information including twist angles and strain in moiré superlattices and crystallographic orientation of van der Waals flakes to support predictable moiré heterostructure fabrication.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microstructure Experiments-Enabled MARMOT Simulations of SiC/SiC-based Accident Tolerant Nuclear Fuel System

We have undertaken an experimental-computational project that addresses a few key technology gaps associated with the use of SiC/SiC composites for light water reactor fuel cladding. Two principal endeavors in this project are to assess the irradiation-induced microstructural changes and swelling in SiC/SiC composites, and to characterize and model the porous oxide surface layer (when exposed to steam) along SiC recession that is detrimental to the clad integrity under accident conditions. The project tasks are: (i) ion irradiation and characterization (University of Tennessee, Knoxville), (ii) mechanical tests and analysis (University of South Carolina), (iii) steam exposure tests (Oak Ridge National Laboratory), (iv) electron microscopy and spectroscopic characterization (NC State University), (v) x-ray microscopy and reconstruction (University of South Carolina and NC State University), (vi) phase field modeling and simulations (NC State University and Idaho National Laboratory). The effects of 10 MeV Au ion irradiation at 350°C on the microstructure evolution in SiC/SiC composites are investigated at doses up to 400 displacements per atom (dpa) at the University of Tennessee, Knoxville. Atomic force microscopy and optical profilometry reveal irradiation induced axial and radial shrinkage of the fibers for doses greater than 10 dpa. Based on detailed electron microscopy characterization, the primary cause of the fiber shrinkage is attributed to irradiation-induced loss of carbon packets. Additionally, the multilayer PyC interface is observed to portray high resistance to irradiation damage. The mechanical response and failure mechanisms of un-irradiated samples is also assessed through loading tests and X-ray imaging at the University of South Carolina. Steam exposure tests are performed at the Oak Ridge National Laboratory in a facility that represents a reactor pressure vessel under a loss-of-coolant-accident scenario. The samples that are analyzed methodically in this report are tested for 32/31 hours at 1200°C with a velocity of 0.25 cm/s for the pressures: 0.1 MPa, 0.45 MPa, 0.92 MPa and 1.38 MPa. Scanning/transmission electron microscopy analysis conducted at the NC State University (NCSU) shows that the oxide layer thickness increases with the steam pressure. While the oxide layer is crystalline (α- cristobalite) for the pressures 0.45 MPa, 0.92 MPa and 1.38 MPa, the layer is amorphous at 0.1 MPa. Results from Raman spectroscopy have also confirmed the formation of α-cristobalite phase of SiO₂. The abrupt increase in the integrated Raman intensity ratio between steam pressures 0.1 and 0.45 MPa suggests the onset of accelerated crystallization. Non-destructive three dimensional X-ray microscopy/tomography (XCT) and computational image processing techniques are employed by the University of South Carolina to probe the porous oxidation features on SiC samples at varying pressures. Interestingly, most pores are observed to be located away from the surface as well as the oxide-SiC interface. The average oxide layer thickness assessed from the XCT analysis is seen to be in excellent agreement with the values determined through scanning electron microscopy analysis for the highest pressures where the oxide layer is relatively more uniform. A phase-field model developed by the NC State University and Idaho National Laboratory for simulating oxidation of SiC by steam captures the paralinear kinetics of SiC oxidation with a high degree of fidelity. Results from quasi-one-dimensional and two dimensional simulations show that the pores with oxidizing species lead to a higher volatilization rate. These simulations indicate that the enhanced apparent volatilization rates at higher pressures observed in experiments can be rationalized by the increased volatilization from the pores. The project team has also successfully developed the capability to import images from experiments for realistic evolution of the oxidizing microstructure.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

On evolution of particle size distribution functions of incipient soot in premixed ethylene-oxygen-argon flames

The evolution of the soot particle size distribution function (PSDF) and particle morphology are studied for premixed ethylene-oxygen-argon flat flames at equivalence ratio {phi}=2.07 over the maximum flame temperature range of 1600-1900 K. Experiments were carried out using an in-situ probe sampling method in tandem with a scanning mobility particle sizer (SMPS), yielding the PSDF for various distances from the burner surface. The morphology of the particles was examined by transmission electron microscopy (TEM) and atomic force microscopy (AFM). Within the particle size range that can be detected, the PSDF transitions from an apparent unimodal PSDF for high temperature flames (T{sub f}>{proportional_to}1800 K) to a bimodal PSDF at lower temperatures (T{sub f}<{proportional_to}1800 K). The bimodal PSDF has a noticeable trough that separates the nucleation tail and log-normal mode. This mode-transition trough had been previously thought to occur at a fixed particle size, but these results show a continuous shift of the trough location towards smaller sizes with increasing flame temperature. TEM images show that the particles are spherical, even when the PSDF is bimodal, suggesting that the bimodality occurs as the primary particles undergoes mass and size growth, and is not a result of particle aggregation. Atomic force microscopy of substrate deposited particles shows that particles spread and form hill like structures upon impact with the substrate surface, indicating that the particles are liquid-like at the time of impact. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Surface Reconstruction in Hydrated Amphiphilic Block Copolymer Thin Films Probed by Fluid Cell Atomic Force Microscopy

In many thin film materials, nuanced interplays of interfacial energies control the surface morphology and rearrangement. This work evaluates polymer−solvent interactions and solvent-driven surface reconstructions via ex situ and in situ fluid cell Atomic Force Microscopy (fc-AFM) analysis of amphiphilic block copolymer (BCP) thin films upon exposure to deionized (DI) water. We examine the differences in surface morphology, whole-film swelling, and force response in thin films of polystyrene-block-poly(ethylene oxide) (PS-b-PEO) and polystyrene- block-poly[(allyl glycidyl ether)-co-(ethylene oxide)] (PS-b- P[AGE-co-EO]) processed into standing-up cylinder morphologies perpendicular to a silicon substrate (⊥C). Using Amplitude Modulation AFM (AM-AFM) and Amplitude-Phase Distance (APD) force spectroscopy, this work probes the mechanoresponsive nature of the dynamic surface layers of these films, unveiling surface layer stratification and surface chain rearrangement via minimal tip−sample stimulation. To help rationalize the observed reconfigurations, the energetic driving forces were estimated using the harmonic mean approximations of interfacial energies. Given the nonionizable nature of the minority P(AGE-co-EO) block and the energetic driving forces for chain mobility, this work shows how the elimination of unfavorable PS−water interfaces drives chain rearrangement and coverage of the PS surface by chains of the hydrophilic block. This work highlights considerations for increasing the heterogeneity and complexity of BCP thin films via random blocks and how those changes to local interfacial energies may drive larger scale film morphology reconstructions, with broader implications for tuning interface hydrophilicity.

Copolymers↗

Elevated temperature, nano-mechanical testing in situ in the scanning electron microscope

A general nano-mechanical test platform capable of performing variable temperature and variable strain rate testing in situ in the scanning electron microscope is described. A variety of test geometries are possible in combination with focused ion beam machining or other fabrication techniques: indentation, micro-compression, cantilever bending, and scratch testing. The system is intrinsically displacement-controlled, which allows it to function directly as a micro-scale thermomechanical test frame. Stable, elevated temperature indentation/micro-compression requires the indenter tip and the sample to be in thermal equilibrium to prevent thermal displacement drift due to thermal expansion. This is achieved through independent heating and temperature monitoring of both the indenter tip and sample. Furthermore, the apex temperature of the indenter tip is calibrated, which allows it to act as a referenced surface temperature probe during contact. A full description of the system is provided, and the effects of indenter geometry and of radiation on imaging conditions are discussed. The stabilization time and temperature distribution throughout the system as a function of temperature is characterized. The advantages of temperature monitoring and thermal calibration of the indenter tip are illustrated, which include the possibility of local thermal conductivity measurement. Finally, validation results using nanoindentation on fused silica and micro-compression of <100> silicon micro-pillars as a function of temperature up to 500 Degree-Sign C are presented, and procedures and considerations taken for these measurements are discussed. A brittle to ductile transition from fracture to splitting then plastic deformation is directly observed in the SEM for silicon as a function of temperature.

36 MATERIALS SCIENCE↗

A data-driven approach to construct a quantitative relationship between microstructural features of fatigue cracks and contact acoustic nonlinearity

This study demonstrates the feasibility of a data-driven approach to construct a quantitative relationship between nonlinear acoustic parameters and microstructural features of contact interfaces. The near-surface nonlinearity is measured using dynamic acousto-elastic testing (DAET) with a surface wave probe, while the microstructural features are extracted from scanning electron microscopy (SEM) images of fatigue cracks. Four aluminum alloy samples, each having a fatigue crack are prepared. Six local nonlinearity parameters are measured at different locations along the crack propagation direction. A total of 40 local measurements are acquired. A principal component analysis (PCA) reveals that all six nonlinearity parameters are correlated and hence can be replaced by one principal component (PC). Fifteen crack micro-geometrical features at each measurement point were extracted from the SEM images. Regression analysis is used to relate the PC of the nonlinearity parameters to the microstructural features at the crack interface. We compare three regression models that take variable selection into account: stepwise multiple linear regression (MLR), stepwise principal component regression (PCR), and least absolute shrinkage and selection operator (LASSO). Despite having different principles, the three predictive models identify two features as the most significant in predicting the interface nonlinearity: the crack aperture (opening) distribution and the distance to the crack tip. The differences between the three models and the physical interpretation of the data-driven predictions are discussed.

36 MATERIALS SCIENCE↗

An ultra-sensitive microfluidic immunoassay using living radical polymerization and porous polymer monoliths.

We present a platform that combines patterned photopolymerized polymer monoliths with living radical polymerization (LRP) to develop a low cost microfluidic based immunoassay capable of sensitive (low to sub pM) and rapid (<30 minute) detection of protein in 100 {micro}L sample. The introduction of LRP functionality to the porous monolith allows one step grafting of functionalized affinity probes from the monolith surface while the composition of the hydrophilic graft chain reduces non-specific interactions and helps to significantly improve the limit of detection.

59 BASIC BIOLOGICAL SCIENCES↗