Search NASA⌕ Search

SEARCH · Search NASA

Results for “Synchronization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Optimizing Grid Regulation With Gravity Storage Systems: A Comparative Analysis With Different Motor Inertias

The integration of renewable energy sources into power grids necessitates solutions for grid support and stability during fluctuations in electricity generation and demand. Gravity energy storage systems (GESS) are emerging as a promising technology for managing the balance between energy supply and demand. However, their capacity to optimize energy flow and offer voltage and frequency regulation amid imbalances in generation and demand is less reported. This paper investigates the control of GESS for optimizing energy flow during voltage and frequency regulation. The study evaluates the regulation capabilities of GESS with different motor inertias during a Texas grid event: one with a high-speed, low-inertia motor and another with a low-speed, high-inertia motor. Results indicate that both GESS scenarios provide fast frequency response by converting potential energy into kinetic energy and vice versa, with a response time of 1.5 s from the frequency variation. This aligns with grid requirements for primary frequency response from traditional synchronous generators and motors with large inertia. Furthermore, a GESS based on a high-inertia motor may be able to operate over a broader range of frequency variations, whereas a low-inertia system may be limited by thermal constraints of the motor.

frequency regulation↗

Large-Scale Inverter Integration in Bulk Power Grids Using Heterogeneous Grid-Forming Control Strategies

The conventional generation within the grid is gradually being replaced by inverter based resources. However, the integration of inverters into realistic transmission grid models has not been thoroughly explored. To address this gap, this work develops an automation framework aimed at facilitating the integration of a large number of inverter-based resources into a large-scale grid. Two types of grid-forming controlled inverters—namely droop-controlled inverters and virtual synchronous machine-controlled inverters—are developed for use in positive-sequence simulation packages. Various penetration levels ranging from 23% to 100% of grid-forming inverters are tested in a grid setup in the US Western Interconnection. The dynamic performance of inverters under different control schemes is compared in response to various disturbances.

Lyu, Xue [BATTELLE (PACIFIC NW LAB)]↗

Polyphase Rotary Transformer for Field Excitation of Electric Machines

This paper presents the magnetic design of a high-frequency three-phase rotary transformer for Wound Rotor Synchronous Motors (WRSM). The traditional DC field excitation of the WRSM is highly challenging as it relies on the brushed connection. The brush/slipring-based connections need cooling, sealing and prone to wear and tear requiring regular maintenance. The proposed three-phase rotary transformer replaces the traditional brushed excitation by a high-power density polyphase wireless excitation. Furthermore, compared to a traditional single-phase rotary transformer, the proposed three-phase rotary transformer significantly enhances the power density, and reduces the eddy current losses and the output voltage ripples.

Aydin, Emrullah↗

A Cost-Effective Wave Energy Harvesting System with Maximum Power Point Tracking Capability

In this paper, we propose a low-cost bidirectional four-switch inverter that transfers three-phase energy between a permanent magnet synchronous generator (PMSG) driven by a wave energy collector and the power grid or a local ac load. To achieve high control performance, the machine-side inverter uses a high-gain observer for rotor position estimation and a Lyapunov-based approach for torque control. For the gridside inverter control, we estimate the filter capacitor voltage with a model reference adaptive system and control the dc-link voltage with a Lyapunov-based energy function. We also track the maximum power point from the sea waves with an integral control law that actively matches the generator impedance with that of the wave collection device. The proposed system supports both grid-following/forming modes. We validate our control design with simulation results on a 3-kW hardware setup.

wave energy, power systems integration, control de↗

Advanced Hierarchical Control Strategies in Multi-Building Microgrids

This paper proposes a hierarchical control system for a multi-building AC microgrid with improved inertia and immunity to communication delay. The primary level control is based on a Virtual Synchronous Generator (VSG) control and the secondary level control is enhanced with a SmithPredictor to improve the stability of the system in the presence of communication delay. Moreover, tertiary level control is proposed to effectively control active and reactive power sharing between the grid and the microgrid. Islanded and grid-connected modes of the microgrid system under study are illustrated with the help of simulation results in MATLAB Simulink environment.

Weldehawaryat, Lidya Mussie [graduate research ass↗

Distributed-Memory Sparse Deep Neural Network Inference Using Global Arrays

Partitioned Global Address Space (PGAS) models exhibit tremendous promise in developing efficient and productive distributed-memory parallel applications. They have been used extensively in scientific computations due to conveniently offering a ``shared-memory''-like model and convenient interfaces that separate communication with synchronization. Traditionally, PGAS communication models have been applied to dense/contiguously distributed data, but most modern applications depict varied levels of sparsity. Existing PGAS models require certain adaptations to support distributed sparse computations, since associated computations often require matrix arithmetic, in addition to data movement. The Global Arrays toolkit from Pacific Northwest National Laboratory (PNNL) is one of the earliest PGAS models to combine one-sided data communication and distributed matrix operations and is still used in the popular NWChem quantum chemistry suite. Recently, we have expanded the Global Arrays toolkit to support common sparse operations, like sparse matrix-dense matrix multiplies (SpMM), sparse matrix-sparse matrix multiplication (SpGEMM) and Sampled Dense-Dense Matrix Multiplication (SDDMM). As it turns out, these operations are the bedrock of sparse Deep Learning (DL); sparse deep neural networks and Graph Neural Networks (GNNs) have gained increasing attention recently in achieving speedups on training and inference with reduced memory footprints. Unlike scientific applications in High Performance Computing (HPC), modern (distributed-memory capable) DL toolkits often rely on non-standardized and closed-source vendor software optimizations, creating challenges in software-hardware co-design at scale. Our goal is to support a variety of distributed-memory sparse matrix operations and helper functions in the newly created Sparse Global Arrays (SGA), such that it is possible to build portable and productive Machine Learning scenarios for algorithm/software and hardware codesign purposes. Contemporary data-parallel schemes for training/inference are undergoing a major overhaul since model replication limits scalability and causes resource inefficiencies. As such, we have adopted tensor parallelism in decomposing the model and inputs, to mitigate memory issues. Current implementation is built on top of MPI and uses CPUs to maximize the portability across the platforms.

Distributed computing, machine learning↗

Fault Contribution of Grid-Following and Grid-Forming Inverters Considering Generic Inverter Controls and Ride-through Requirements

Gradual transformation of the synchronous generator (SG)-dominated power systems to inverter-based resource (IBR)-dominated power systems is bringing new challenges regarding power system protection. Increasing IBR’s penetration will reduce the reliability of protection coordination, originally developed for SG-dominated power systems, potentially leading to less accurate calculation or even mis-operation. Thus, new protection schemes compatible with IBR-dominated power systems should be established. Prior to establishing the protection schemes, research on the fault contribution of generic IBR models should be conducted considering interconnection requirements. This paper conducts fault current contribution analysis of generic grid-following (GFL) and grid-forming (GFM) inverters considering interconnection requirements using an electromagnetic transient (EMT) simulation tool. To do this, EMT-based generic GFL models have been developed with the ride-through requirements from IEEE-1547 standards. In addition, the major functions of the generic models are explained. Then, the fault current analysis was conducted using GFL and GFM inverters in a single-inverter-infinite-bus system and a modified IEEE 34-node system considering different grid, fault, inverter control parameters.

Kim, Jinho [BATTELLE (PACIFIC NW LAB)]↗

Impedance Emulation Control of Wave Energy Converters

Modeling and control of wave energy conversion (WEC) systems for maximum power extraction is challenging due to complex multiphysics that include fluids, mechanics, and machine drives. To uncover an intuitive model that clearly depicts WEC system operation, we utilize a force-current equivalent circuit framework which then enables us to design an impedance emulation control strategy. To provide context for our framework, we focus on a standard reference model-3 (RM3) point absorber device coupled to a permanent magnet synchronous generator. After the proposed extremum seeking controller is computed, we experimentally validate its performance on a platform that consists of two back-to-back connected inverters that emulate the WEC system.

wave energy conversion, impedance emulation, machi↗

Energy–Performance Trade-offs in Privacy-Preserving Federated Learning on SmartNIC-Enabled HPC Systems

Federated learning (FL) is increasingly deployed on accelerator-rich high-performance computing (HPC) systems, yet the system-level energy cost of privacy-aware FL remains poorly understood, particularly across heterogeneous networking and server-placement options. We present a measurement-driven study of energy–performance trade-offs for FL on GH200-class nodes across three deployment configurations: CPU-Ethernet, CPU-InfiniBand (RDMA-capable), and a DPU-hosted FL server over InfiniBand using a BlueField-3 SmartNIC/DPU. Using NVIDIA FLARE (NVFLARE), we align node-level power telemetry with per-round timing extracted from NVFLARE logs to quantify time-to-solution (TTS), energy-to-solution (ETS), energy-delay product (EDP), and synchronization behavior for three transformer models (ALBERT, DistilBERT, BERT), trained with and without differential privacy (DP). We find that interconnect choice is the dominant driver of runtime and energy: host-managed InfiniBand consistently reduces communication overhead versus Ethernet, yielding lower TTS/ETS/EDP. In contrast, in our NVFLARE deployment, placing the FL server on the DPU does not consistently match CPU-InfiniBand performance and can be slower—especially for larger models—highlighting that server placement alone is not sufficient to guarantee end-to-end gains. Finally, under our fixed-round protocol, DP increases per-round cost and runtime variance; ETS increases largely in proportion to TTS because average node power remains relatively stable across configurations.

Kotevska, Olivera [ORNL] (ORCID:0000000316772243)↗

A Physics-Aligned Multi-Domain Machine Learning Framework for Time-Localised Diagnosis of Power Electronics Faults

This paper presents a physics-aligned framework for fault diagnosis in multi-phase power-electronic systems using cycle-synchronous windowing and multi-domain features derived from Fourier, wavelet, and Hilbert–Huang representations. While both logistic regression and multilayer perceptron (MLP) models achieve perfect performance under standard evaluation, blind unseen testing reveals a critical failure in a baseline MLP. This is shown to arise from model selection based on validation accuracy. Using validation-loss-based selection restores correct unseen performance and improves confidence. Feature ablation shows that Fourier and wavelet features dominate, while computational analysis indicates that feature extraction, particularly HHT, governs runtime.

Kumar, Praveen [ORNL] (ORCID:0000000291877857)↗

Inverter Intensive Hybrid Power Plant Modeling with Small-Signal Stability Augmentation through Flexible Operation Mode Transition

Hybrid power plants (HPPs) prompt the penetration of inverter-based renewable energy sources (RES) in transmission systems; however, given their low-inertia nature, HPPs are dominated by power electronic inverters, so there are inevitable challenges in system stability when increasing numbers of HPPs are integrated into the modern power grids. To boost the penetration level of HPPs without jeopardizing system stability, it is desirable to equip them with operational characteristics (i.e., grid-forming capabilities) that are comparable to those of conventional power plants dominated by synchronous generators (SGs). In this paper, a holistic model of inverter intensive HPP is derived and a bi-level hierarchical control is developed to allow HPPs to flexibly switch among the designed operation modes (i.e., P-Q, P-V, and isochronous modes). Compared to SGs, which have limited controllability, the operation mode of each HPP could vary as requested. Such flexible mode transitions could be integrated into the secondary plant-level control and be leveraged as an additional control degree to further augment system stability. Further, the system small-signal stability margin is quantified with varying HPP operation modes. More importantly, modal analysis is thereby conducted to quantify the impacts of mode transition on the system oscillatory modes. The effectiveness of the proposed HPP bi-level hierarchical control is verified using extensive case studies based on the simplified real-world island power grid, and the results validate that the system small-signal stability margin can be enhanced with the additional degree of control flexibility enabled by HPP operation mode transition. The real-time hardware-in-the-loop (HIL) results are also provided to verify the proposed method.

grid-forming control↗

Distributed Inertia Management Under Communication Constraints

This paper presents a framework for distributed inertia management based on consensus algorithm. We propose a methodology to achieve optimal operation of inertia sources such as distributed energy resources (DERs) and synchronous generators in real time. Additionally, we analyze the algorithm under communication constraints and evaluate its robustness under scenarios involving communication time delays and packet losses. The proposed approach is validated via simulations on a 4-node system test feeder, demonstrating its effectiveness and resilience.

Yadav, Ajay [ORNL] (ORCID:000000016111881X)↗

Coherency-Aware Learning Control of Inverter-Dominated Grids: A Distributed Risk-Constrained Approach

Here, this letter investigates the importance of integrating the coherency knowledge for designing controllers to dampen sustained oscillations in wide-area power networks with significant penetration of inverter-interfaced resources. Coherency is a fundamental property of power systems, where time-scale separation in frequency dynamics leads to clustered behavior among generators of different groups. Large-scale penetration of inverter-driven low inertia resources replacing conventional synchronous generators (SGs) can lead to perturbation in the coherent partitioning; hence, integrating such information is of utmost importance for oscillation control designs. We present the coherency-aware design of a distributed output feedback-based reinforcement learning method that additionally incorporates risk constraints to capture the uncertainties related to net-load fluctuations. The use of domain-aware coherency information has produced improved training and oscillation performance than the coherency-agnostic control design, hence proving to be effective in controller design. Finally, we validated the proposed method with numerical experiments on the benchmark IEEE 68-bus test system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Feedback and Oscillations: Constructing Feedback Systems for Root Cause Analysis of Oscillations in Power Grids

Dynamic phenomena linked to inverter-based resources (IBRs) have gained global attention. Several IBR-induced dynamics have caused bulk power system-connected wind or solar power plants to trip, and some have even led to widespread outages. In addition, many oscillations have been observed involving IBR power plants. In 2023, the IEEE Power & Energy Society (PES) IBR Subsynchronous Oscillations (SSO) task force published a journal article, “Real-World Subsynchronous Oscillation Events in Power Grids With High Penetrations of Inverter-Based Resources,” in which 19 IBR oscillation events were examined for their causation. Earlier in 2020, another PES task force article, “Definition and Classification of Power System Stability-Revisited & Extended,” authored by prominent academics, introduced converter-driven stability as a new category of stability. The international power grid industry community also took action by publishing the CIGRE Green Book, Power System Dynamic Modelling and Analysis in Evolving Networks (led by Babak Badrzadeh and Zia Emin) in 2024. In August 2024, the Energy Systems Integration Group (ESIG) released a practical guide led by Nick Miller, “Diagnosis and Mitigation of Observed Oscillations in IBR-Dominant Power System: A Practical Guide.” The goal of the guide is to assist practicing engineers in making initial judgments and conducting detailed analyses about oscillations. Finally, when addressing the classification of stability and oscillations, the guide emphasizes a causality-based taxonomy for grouping, such as voltage control-induced oscillations, synchronization-induced oscillations, and frequency or active power control-induced oscillations.

Fan, Lingling [Univ. of South Florida, Tampa, FL (↗

Ensuring Solution Uniqueness in Three-Phase Power System State Estimation

This paper is concerned with the issue of potential non-unique solutions in three-phase state estimation. Theory of observability analysis for positive sequence power system state estimation is based on certain assumptions that avoid possibility of multiple solutions. Also, it is shown that observability of a positive sequence network remains independent of the network parameters or the operating state. When extending single-phase observability analysis directly to the three-phase case, this paper considers the possibility of converging to multiple solutions, i.e. solution non-uniqueness, even for cases where state estimator successfully converges. The study illustrates via numerical examples the likelihood of converging to entirely different solutions for certain network parameters. It also examines how the operating state, particularly under unbalanced loading, leads to solution non-uniqueness. The paper then describes an alternative approach to ensure a unique solution in three-phase state estimation. This method aims to accurately and uniquely estimate the state of any unbalanced three-phase system, irrespective of load imbalance, network configuration, existence of synchronous generators or transformers.

Power System State Estimation, Three-Phase, Distri↗

Voltage Probability Density Function Shaping Control Strategy Considering Grid Operational Uncertainties

It is well-known that power systems operation always affected by various uncertainties which make the bus voltage a random process that can be characterized by its probability density function (PDF) at any time instant. In this context, this paper presents a novel PDF-based voltage control framework for power systems. By modeling voltage as a stochastic process, we formulate a stochastic differential equationthat captures grid uncertainties. The associated Fokker-Planck-Kolmogorov equation is derived to describe the evolution of the voltage PDF, which enables the formulation of a PDF-shaping control strategy. To simplify the PDF control formulation, a B-spline neural network is introduced for real-time estimation and regulation of the voltage distribution. The proposed PDF control law updates voltage references for energy storage systems and synchronous generators using real-time PDF measurements and feedback signals. The proposed method is validated on a modified Kundur’s two-area system. Simulation results demonstrate that the controller can significantly improve the voltage stability under stochastic conditions, highlighting its effectiveness in modern inverter-rich grids.

Gui, Yonghao [ORNL] (ORCID:0000000250435534)↗

Impact of Geomagnetic Induced Current Neutral Blocking Devices on Distance Relays in Sub-transmission Networks with IBR

Geomagnetically induced currents (GICs) can flow through transmission lines during geomagnetic disturbances, such as solar flares or coronal mass ejections. These currents can cause problems like transformer saturation and equipment damage. The most common method of mitigating GICs involves installing GIC neutral blocking devices (NBDs) in transformer neutrals. However, the wide application of capacitive GIC blocking devices may have unintended adverse effects on other devices, such as distance protection relays. As the number of inverter-based resources being connected to the transmission and sub-transmission systems increases, the likelihood of a sub-transmission line protected by a distance relay connected to a transformer with NBDs is increasing. Therefore, distance relays fed by IBRs and transmission lines with GIC-NBDs must be studied. This paper studies the effect of GIC-NBDs on a 69kV sub-transmission line of various lengths fed by a 25 MVA IBR and synchronous source. This work focused on the behavior of the GIC-NBDs using the measured apparent phase-to-ground and phase-to-phase impedance calculated by the relay and the source impedance ratio (SIR) during various electrical faults.

Patel, Trupal R [Sandia National Laboratories (SNL↗

A Performance Model of In-Situ Techniques

The computational capacity of High-Performance Computing (HPC) systems increases continuously with the rapid development of central processing units (CPUs) and graphic processing units (GPUs), while the in-/output (IO) subsystem develops relatively slowly and storage capacity is also limited. Data-intensive applications, which are designed to leverage the high computational capacity of HPC resources, typically generate a considerable amount of data for post-processing visualizations and data analytics. The limited IO speed and storage space could lead to constraints in the actual performance of these applications and, therefore, scientific discovery. In-situ techniques, where data is visualized/analysed while still in memory rather than through disk, can contribute to alleviating these problems as they can reduce or even fully avoid data writing/reading through the IO subsystem to/from storage. However, the overall efficiency of insitu techniques crucially depends on the characteristics of both the in-situ tasks and the applications, and the resource distribution among them. Therefore, choosing the right in-situ approach (synchronous, asynchronous, or hybrid) and resource allocation is essential to minimize overhead and maximize the benefits of concurrent execution. In this paper, we present a performance model of in-situ techniques to find the most beneficial in-situ approach and the preferred resource configuration. We verify the high accuracy of our approach with over 6800 measurements and provide use cases with different applications.

Ju, Yi [Max Planck Computing and Data Facility, Ga↗